mirror of
git://sourceware.org/git/lvm2.git
synced 2024-12-22 17:35:59 +03:00
1320 lines
37 KiB
Groff
1320 lines
37 KiB
Groff
.TH "LVMRAID" "7" "LVM TOOLS #VERSION#" "Red Hat, Inc" "\""
|
|
|
|
.SH NAME
|
|
lvmraid \(em LVM RAID
|
|
|
|
.SH DESCRIPTION
|
|
|
|
LVM RAID is a way to create logical volumes (LVs) that use multiple physical
|
|
devices to improve performance or tolerate device failure. How blocks of
|
|
data in an LV are placed onto physical devices is determined by the RAID
|
|
level. RAID levels are commonly referred to by number, e.g. raid1, raid5.
|
|
Selecting a RAID level involves tradeoffs among physical device
|
|
requirements, fault tolerance, and performance. A description of the RAID
|
|
levels can be found at
|
|
.br
|
|
www.snia.org/sites/default/files/SNIA_DDF_Technical_Position_v2.0.pdf
|
|
|
|
LVM RAID uses both Device Mapper (DM) and Multiple Device (MD) drivers
|
|
from the Linux kernel. DM is used to create and manage visible LVM
|
|
devices, and MD is used to place data on physical devices.
|
|
|
|
.SH Create a RAID LV
|
|
|
|
To create a RAID LV, use lvcreate and specify an LV type.
|
|
The LV type corresponds to a RAID level.
|
|
The basic RAID levels that can be used are:
|
|
.B raid0, raid1, raid4, raid5, raid6, raid10.
|
|
|
|
.B lvcreate \-\-type
|
|
.I RaidLevel
|
|
[\fIOPTIONS\fP]
|
|
.B \-\-name
|
|
.I Name
|
|
.B \-\-size
|
|
.I Size
|
|
.I VG
|
|
[\fIPVs\fP]
|
|
|
|
To display the LV type of an existing LV, run:
|
|
|
|
.B lvs -o name,segtype
|
|
\fIVG\fP/\fILV\fP
|
|
|
|
(The LV type is also referred to as "segment type" or "segtype".)
|
|
|
|
LVs can be created with the following types:
|
|
|
|
.SS raid0
|
|
|
|
\&
|
|
|
|
Also called striping, raid0 spreads LV data across multiple devices in
|
|
units of stripe size. This is used to increase performance. LV data will
|
|
be lost if any of the devices fail.
|
|
|
|
.B lvcreate \-\-type raid0
|
|
[\fB\-\-stripes\fP \fINumber\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
|
|
.HP
|
|
.B \-\-stripes
|
|
specifies the number of devices to spread the LV across.
|
|
|
|
.HP
|
|
.B \-\-stripesize
|
|
specifies the size of each stripe in kilobytes. This is the amount of
|
|
data that is written to one device before moving to the next.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
\fINumber\fP devices, one for each stripe.
|
|
|
|
.SS raid1
|
|
|
|
\&
|
|
|
|
Also called mirroring, raid1 uses multiple devices to duplicate LV data.
|
|
The LV data remains available if all but one of the devices fail.
|
|
The minimum number of devices required is 2.
|
|
|
|
.B lvcreate \-\-type raid1
|
|
[\fB\-\-mirrors\fP \fINumber\fP]
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
|
|
.HP
|
|
.B \-\-mirrors
|
|
specifies the number of mirror images in addition to the original LV
|
|
image, e.g. \-\-mirrors 1 means there are two images of the data, the
|
|
original and one mirror image.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
\fINumber\fP devices, one for each image.
|
|
|
|
.SS raid4
|
|
|
|
\&
|
|
|
|
raid4 is a form of striping that uses an extra device dedicated to storing
|
|
parity blocks. The LV data remains available if one device fails. The
|
|
parity is used to recalculate data that is lost from a single device. The
|
|
minimum number of devices required is 3.
|
|
|
|
.B lvcreate \-\-type raid4
|
|
[\fB\-\-stripes\fP \fINumber\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
|
|
.HP
|
|
.B \-\-stripes
|
|
specifies the number of devices to use for LV data. This does not include
|
|
the extra device lvm adds for storing parity blocks. \fINumber\fP stripes
|
|
requires \fINumber\fP+1 devices. \fINumber\fP must be 2 or more.
|
|
|
|
.HP
|
|
.B \-\-stripesize
|
|
specifies the size of each stripe in kilobytes. This is the amount of
|
|
data that is written to one device before moving to the next.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
\fINumber\fP+1 separate devices.
|
|
|
|
raid4 is called non-rotating parity because the parity blocks are always
|
|
stored on the same device.
|
|
|
|
.SS raid5
|
|
|
|
\&
|
|
|
|
raid5 is a form of striping that uses an extra device for storing parity
|
|
blocks. LV data and parity blocks are stored on each device. The LV data
|
|
remains available if one device fails. The parity is used to recalculate
|
|
data that is lost from a single device. The minimum number of devices
|
|
required is 3.
|
|
|
|
.B lvcreate \-\-type raid5
|
|
[\fB\-\-stripes\fP \fINumber\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
|
|
.HP
|
|
.B \-\-stripes
|
|
specifies the number of devices to use for LV data. This does not include
|
|
the extra device lvm adds for storing parity blocks. \fINumber\fP stripes
|
|
requires \fINumber\fP+1 devices. \fINumber\fP must be 2 or more.
|
|
|
|
.HP
|
|
.B \-\-stripesize
|
|
specifies the size of each stripe in kilobytes. This is the amount of
|
|
data that is written to one device before moving to the next.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
\fINumber\fP+1 separate devices.
|
|
|
|
raid5 is called rotating parity because the parity blocks are placed on
|
|
different devices in a round-robin sequence. There are variations of
|
|
raid5 with different algorithms for placing the parity blocks. The
|
|
default variant is raid5_ls (raid5 left symmetric, which is a rotating
|
|
parity 0 with data restart.) See \fBRAID5 variants\fP below.
|
|
|
|
.SS raid6
|
|
|
|
\&
|
|
|
|
raid6 is a form of striping like raid5, but uses two extra devices for
|
|
parity blocks. LV data and parity blocks are stored on each device. The
|
|
LV data remains available if up to two devices fail. The parity is used
|
|
to recalculate data that is lost from one or two devices. The minimum
|
|
number of devices required is 5.
|
|
|
|
.B lvcreate \-\-type raid6
|
|
[\fB\-\-stripes\fP \fINumber\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
|
|
.HP
|
|
.B \-\-stripes
|
|
specifies the number of devices to use for LV data. This does not include
|
|
the extra two devices lvm adds for storing parity blocks. \fINumber\fP
|
|
stripes requires \fINumber\fP+2 devices. \fINumber\fP must be 3 or more.
|
|
|
|
.HP
|
|
.B \-\-stripesize
|
|
specifies the size of each stripe in kilobytes. This is the amount of
|
|
data that is written to one device before moving to the next.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
\fINumber\fP+2 separate devices.
|
|
|
|
Like raid5, there are variations of raid6 with different algorithms for
|
|
placing the parity blocks. The default variant is raid6_zr (raid6 zero
|
|
restart, aka left symmetric, which is a rotating parity 0 with data
|
|
restart.) See \fBRAID6 variants\fP below.
|
|
|
|
.SS raid10
|
|
|
|
\&
|
|
|
|
raid10 is a combination of raid1 and raid0, striping data across mirrored
|
|
devices. LV data remains available if one or more devices remains in each
|
|
mirror set. The minimum number of devices required is 4.
|
|
|
|
.B lvcreate \-\-type raid10
|
|
.RS
|
|
[\fB\-\-mirrors\fP \fINumberMirrors\fP]
|
|
.br
|
|
[\fB\-\-stripes\fP \fINumberStripes\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
.br
|
|
\fIVG\fP
|
|
[\fIPVs\fP]
|
|
.RE
|
|
|
|
.HP
|
|
.B \-\-mirrors
|
|
specifies the number of mirror images within each stripe. e.g.
|
|
\-\-mirrors 1 means there are two images of the data, the original and one
|
|
mirror image.
|
|
|
|
.HP
|
|
.B \-\-stripes
|
|
specifies the total number of devices to use in all raid1 images (not the
|
|
number of raid1 devices to spread the LV across, even though that is the
|
|
effective result). The number of devices in each raid1 mirror will be
|
|
NumberStripes/(NumberMirrors+1), e.g. mirrors 1 and stripes 4 will stripe
|
|
data across two raid1 mirrors, where each mirror is devices.
|
|
|
|
.HP
|
|
.B \-\-stripesize
|
|
specifies the size of each stripe in kilobytes. This is the amount of
|
|
data that is written to one device before moving to the next.
|
|
.P
|
|
|
|
\fIPVs\fP specifies the devices to use. If not specified, lvm will choose
|
|
the necessary devices. Devices are used to create mirrors in the
|
|
order listed, e.g. for mirrors 1, stripes 2, listing PV1 PV2 PV3 PV4
|
|
results in mirrors PV1/PV2 and PV3/PV4.
|
|
|
|
RAID10 is not mirroring on top of stripes, which would be RAID01, which is
|
|
less tolerant of device failures.
|
|
|
|
|
|
.SH Synchronization
|
|
|
|
Synchronization makes all the devices in a RAID LV consistent with each
|
|
other.
|
|
|
|
In a RAID1 LV, all mirror images should have the same data. When a new
|
|
mirror image is added, or a mirror image is missing data, then images need
|
|
to be synchronized. Data blocks are copied from an existing image to a
|
|
new or outdated image to make them match.
|
|
|
|
In a RAID 4/5/6 LV, parity blocks and data blocks should match based on
|
|
the parity calculation. When the devices in a RAID LV change, the data
|
|
and parity blocks can become inconsistent and need to be synchronized.
|
|
Correct blocks are read, parity is calculated, and recalculated blocks are
|
|
written.
|
|
|
|
The RAID implementation keeps track of which parts of a RAID LV are
|
|
synchronized. This uses a bitmap saved in the RAID metadata. The bitmap
|
|
can exclude large parts of the LV from synchronization to reduce the
|
|
amount of work. Without this, the entire LV would need to be synchronized
|
|
every time it was activated. When a RAID LV is first created and
|
|
activated the first synchronization is called initialization.
|
|
|
|
Automatic synchronization happens when a RAID LV is activated, but it is
|
|
usually partial because the bitmaps reduce the areas that are checked.
|
|
A full sync may become necessary when devices in the RAID LV are changed.
|
|
|
|
The synchronization status of a RAID LV is reported by the
|
|
following command, where "image synced" means sync is complete:
|
|
|
|
.B lvs -a -o name,sync_percent
|
|
|
|
|
|
.SS Scrubbing
|
|
|
|
Scrubbing is a full scan/synchronization of the RAID LV requested by a user.
|
|
Scrubbing can find problems that are missed by partial synchronization.
|
|
|
|
Scrubbing assumes that RAID metadata and bitmaps may be inaccurate, so it
|
|
verifies all RAID metadata, LV data, and parity blocks. Scrubbing can
|
|
find inconsistencies caused by hardware errors or degradation. These
|
|
kinds of problems may be undetected by automatic synchronization which
|
|
excludes areas outside of the RAID write-intent bitmap.
|
|
|
|
The command to scrub a RAID LV can operate in two different modes:
|
|
|
|
.B lvchange \-\-syncaction
|
|
.BR check | repair
|
|
.IR VG / LV
|
|
|
|
.HP
|
|
.B check
|
|
Check mode is read\-only and only detects inconsistent areas in the RAID
|
|
LV, it does not correct them.
|
|
|
|
.HP
|
|
.B repair
|
|
Repair mode checks and writes corrected blocks to synchronize any
|
|
inconsistent areas.
|
|
|
|
.P
|
|
|
|
Scrubbing can consume a lot of bandwidth and slow down application I/O on
|
|
the RAID LV. To control the I/O rate used for scrubbing, use:
|
|
|
|
.HP
|
|
.B \-\-maxrecoveryrate
|
|
.BR \fIRate [ b | B | s | S | k | K | m | M | g | G ]
|
|
.br
|
|
Sets the maximum recovery rate for a RAID LV. \fIRate\fP is specified as
|
|
an amount per second for each device in the array. If no suffix is given,
|
|
then KiB/sec/device is assumed. Setting the recovery rate to \fB0\fP
|
|
means it will be unbounded.
|
|
|
|
.HP
|
|
.BR \-\-minrecoveryrate
|
|
.BR \fIRate [ b | B | s | S | k | K | m | M | g | G ]
|
|
.br
|
|
Sets the minimum recovery rate for a RAID LV. \fIRate\fP is specified as
|
|
an amount per second for each device in the array. If no suffix is given,
|
|
then KiB/sec/device is assumed. Setting the recovery rate to \fB0\fP
|
|
means it will be unbounded.
|
|
|
|
.P
|
|
|
|
To display the current scrubbing in progress on an LV, including
|
|
the syncaction mode and percent complete, run:
|
|
|
|
.B lvs -a -o name,raid_sync_action,sync_percent
|
|
|
|
After scrubbing is complete, to display the number of inconsistent blocks
|
|
found, run:
|
|
|
|
.B lvs -o name,raid_mismatch_count
|
|
|
|
Also, if mismatches were found, the lvs attr field will display the letter
|
|
"m" (mismatch) in the 9th position, e.g.
|
|
|
|
.nf
|
|
# lvs -o name,vgname,segtype,attr vg/lvol0
|
|
LV VG Type Attr
|
|
lvol0 vg raid1 Rwi-a-r-m-
|
|
.fi
|
|
|
|
|
|
.SS Scrubbing Limitations
|
|
|
|
The \fBcheck\fP mode can only report the number of inconsistent blocks, it
|
|
cannot report which blocks are inconsistent. This makes it impossible to
|
|
know which device has errors, or if the errors affect file system data,
|
|
metadata or nothing at all.
|
|
|
|
The \fBrepair\fP mode can make the RAID LV data consistent, but it does
|
|
not know which data is correct. The result may be consistent but
|
|
incorrect data. When two different blocks of data must be made
|
|
consistent, it chooses the block from the device that would be used during
|
|
RAID intialization. However, if the PV holding corrupt data is known,
|
|
lvchange \-\-rebuild can be used to reconstruct the data on the bad
|
|
device.
|
|
|
|
Future developments might include:
|
|
|
|
Allowing a user to choose the correct version of data during repair.
|
|
|
|
Using a majority of devices to determine the correct version of data to
|
|
use in a three-way RAID1 or RAID6 LV.
|
|
|
|
Using a checksumming device to pin-point when and where an error occurs,
|
|
allowing it to be rewritten.
|
|
|
|
|
|
.SH SubLVs
|
|
|
|
An LV is often a combination of other hidden LVs called SubLVs. The
|
|
SubLVs either use physical devices, or are built from other SubLVs
|
|
themselves. SubLVs hold LV data blocks, RAID parity blocks, and RAID
|
|
metadata. SubLVs are generally hidden, so the lvs \-a option is required
|
|
display them:
|
|
|
|
.B lvs -a -o name,segtype,devices
|
|
|
|
SubLV names begin with the visible LV name, and have an automatic suffix
|
|
indicating its role:
|
|
|
|
.IP \(bu 3
|
|
SubLVs holding LV data or parity blocks have the suffix _rimage_#.
|
|
These SubLVs are sometimes referred to as DataLVs.
|
|
|
|
.IP \(bu 3
|
|
SubLVs holding RAID metadata have the suffix _rmeta_#. RAID metadata
|
|
includes superblock information, RAID type, bitmap, and device health
|
|
information. These SubLVs are sometimes referred to as MetaLVs.
|
|
|
|
.P
|
|
|
|
SubLVs are an internal implementation detail of LVM. The way they are
|
|
used, constructed and named may change.
|
|
|
|
The following examples show the SubLV arrangement for each of the basic
|
|
RAID LV types, using the fewest number of devices allowed for each.
|
|
|
|
.SS Examples
|
|
|
|
.B raid0
|
|
.br
|
|
Each rimage SubLV holds a portion of LV data. No parity is used.
|
|
No RAID metadata is used.
|
|
|
|
.nf
|
|
lvcreate --type raid0 --stripes 2 --name lvr0 ...
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr0 raid0 lvr0_rimage_0(0),lvr0_rimage_1(0)
|
|
[lvr0_rimage_0] linear /dev/sda(...)
|
|
[lvr0_rimage_1] linear /dev/sdb(...)
|
|
.fi
|
|
|
|
.B raid1
|
|
.br
|
|
Each rimage SubLV holds a complete copy of LV data. No parity is used.
|
|
Each rmeta SubLV holds RAID metadata.
|
|
|
|
.nf
|
|
lvcreate --type raid1 --mirrors 1 --name lvr1 ...
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr1 raid1 lvr1_rimage_0(0),lvr1_rimage_1(0)
|
|
[lvr1_rimage_0] linear /dev/sda(...)
|
|
[lvr1_rimage_1] linear /dev/sdb(...)
|
|
[lvr1_rmeta_0] linear /dev/sda(...)
|
|
[lvr1_rmeta_1] linear /dev/sdb(...)
|
|
.fi
|
|
|
|
.B raid4
|
|
.br
|
|
Two rimage SubLVs each hold a portion of LV data and one rimage SubLV
|
|
holds parity. Each rmeta SubLV holds RAID metadata.
|
|
|
|
.nf
|
|
lvcreate --type raid4 --stripes 2 --name lvr4 ...
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr4 raid4 lvr4_rimage_0(0),\\
|
|
lvr4_rimage_1(0),\\
|
|
lvr4_rimage_2(0)
|
|
[lvr4_rimage_0] linear /dev/sda(...)
|
|
[lvr4_rimage_1] linear /dev/sdb(...)
|
|
[lvr4_rimage_2] linear /dev/sdc(...)
|
|
[lvr4_rmeta_0] linear /dev/sda(...)
|
|
[lvr4_rmeta_1] linear /dev/sdb(...)
|
|
[lvr4_rmeta_2] linear /dev/sdc(...)
|
|
.fi
|
|
|
|
.B raid5
|
|
.br
|
|
Three rimage SubLVs each hold a portion of LV data and parity.
|
|
Each rmeta SubLV holds RAID metadata.
|
|
|
|
.nf
|
|
lvcreate --type raid5 --stripes 2 --name lvr5 ...
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr5 raid5 lvr5_rimage_0(0),\\
|
|
lvr5_rimage_1(0),\\
|
|
lvr5_rimage_2(0)
|
|
[lvr5_rimage_0] linear /dev/sda(...)
|
|
[lvr5_rimage_1] linear /dev/sdb(...)
|
|
[lvr5_rimage_2] linear /dev/sdc(...)
|
|
[lvr5_rmeta_0] linear /dev/sda(...)
|
|
[lvr5_rmeta_1] linear /dev/sdb(...)
|
|
[lvr5_rmeta_2] linear /dev/sdc(...)
|
|
.fi
|
|
|
|
.B raid6
|
|
.br
|
|
Six rimage SubLVs each hold a portion of LV data and parity.
|
|
Each rmeta SubLV holds RAID metadata.
|
|
|
|
.nf
|
|
lvcreate --type raid6 --stripes 3 --name lvr6
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr6 raid6 lvr6_rimage_0(0),\\
|
|
lvr6_rimage_1(0),\\
|
|
lvr6_rimage_2(0),\\
|
|
lvr6_rimage_3(0),\\
|
|
lvr6_rimage_4(0),\\
|
|
lvr6_rimage_5(0)
|
|
[lvr6_rimage_0] linear /dev/sda(...)
|
|
[lvr6_rimage_1] linear /dev/sdb(...)
|
|
[lvr6_rimage_2] linear /dev/sdc(...)
|
|
[lvr6_rimage_3] linear /dev/sdd(...)
|
|
[lvr6_rimage_4] linear /dev/sde(...)
|
|
[lvr6_rimage_5] linear /dev/sdf(...)
|
|
[lvr6_rmeta_0] linear /dev/sda(...)
|
|
[lvr6_rmeta_1] linear /dev/sdb(...)
|
|
[lvr6_rmeta_2] linear /dev/sdc(...)
|
|
[lvr6_rmeta_3] linear /dev/sdd(...)
|
|
[lvr6_rmeta_4] linear /dev/sde(...)
|
|
[lvr6_rmeta_5] linear /dev/sdf(...)
|
|
|
|
.B raid10
|
|
.br
|
|
Four rimage SubLVs each hold a portion of LV data. No parity is used.
|
|
Each rmeta SubLV holds RAID metadata.
|
|
|
|
.nf
|
|
lvcreate --type raid10 --stripes 2 --mirrors 1 --name lvr10
|
|
|
|
lvs -a -o name,segtype,devices
|
|
lvr10 raid10 lvr10_rimage_0(0),\\
|
|
lvr10_rimage_1(0),\\
|
|
lvr10_rimage_2(0),\\
|
|
lvr10_rimage_3(0)
|
|
[lvr10_rimage_0] linear /dev/sda(...)
|
|
[lvr10_rimage_1] linear /dev/sdb(...)
|
|
[lvr10_rimage_2] linear /dev/sdc(...)
|
|
[lvr10_rimage_3] linear /dev/sdd(...)
|
|
[lvr10_rmeta_0] linear /dev/sda(...)
|
|
[lvr10_rmeta_1] linear /dev/sdb(...)
|
|
[lvr10_rmeta_2] linear /dev/sdc(...)
|
|
[lvr10_rmeta_3] linear /dev/sdd(...)
|
|
.fi
|
|
|
|
|
|
.SH Device Failure
|
|
|
|
Physical devices in a RAID LV can fail or be lost for multiple reasons.
|
|
A device could be disconnected, permanently failed, or temporarily
|
|
disconnected. The purpose of RAID LVs (levels 1 and higher) is to
|
|
continue operating in a degraded mode, without losing LV data, even after
|
|
a device fails. The number of devices that can fail without the loss of
|
|
LV data depends on the RAID level:
|
|
|
|
.IP \[bu] 3
|
|
RAID0 (striped) LVs cannot tolerate losing any devices. LV data will be
|
|
lost if any devices fail.
|
|
|
|
.IP \[bu] 3
|
|
RAID1 LVs can tolerate losing all but one device without LV data loss.
|
|
|
|
.IP \[bu] 3
|
|
RAID4 and RAID5 LVs can tolerate losing one device without LV data loss.
|
|
|
|
.IP \[bu] 3
|
|
RAID6 LVs can tolerate losing two devices without LV data loss.
|
|
|
|
.IP \[bu] 3
|
|
RAID10 is variable, and depends on which devices are lost. It can
|
|
tolerate losing all but one device in a single raid1 mirror without
|
|
LV data loss.
|
|
|
|
.P
|
|
|
|
If a RAID LV is missing devices, or has other device-related problems, lvs
|
|
reports this in the health_status (and attr) fields:
|
|
|
|
.B lvs -o name,lv_health_status
|
|
|
|
.B partial
|
|
.br
|
|
Devices are missing from the LV. This is also indicated by the letter "p"
|
|
(partial) in the 9th position of the lvs attr field.
|
|
|
|
.B refresh needed
|
|
.br
|
|
A device was temporarily missing but has returned. The LV needs to be
|
|
refreshed to use the device again (which will usually require
|
|
partial synchronization). This is also indicated by the letter "r" (refresh
|
|
needed) in the 9th position of the lvs attr field. See
|
|
\fBRefreshing an LV\fP. This could also indicate a problem with the
|
|
device, in which case it should be be replaced, see
|
|
\fBReplacing Devices\fP.
|
|
|
|
.B mismatches exist
|
|
.br
|
|
See
|
|
.BR Scrubbing .
|
|
|
|
Most commands will also print a warning if a device is missing, e.g.
|
|
.br
|
|
.nf
|
|
WARNING: Device for PV uItL3Z-wBME-DQy0-... not found or rejected ...
|
|
.fi
|
|
|
|
This warning will go away if the device returns or is removed from the
|
|
VG (see \fBvgreduce \-\-removemissing\fP).
|
|
|
|
|
|
.SS Activating an LV with missing devices
|
|
|
|
A RAID LV that is missing devices may be activated or not, depending on
|
|
the "activation mode" used in lvchange:
|
|
|
|
.B lvchange \-ay \-\-activationmode
|
|
.RB { complete | degraded | partial }
|
|
.IR VG / LV
|
|
|
|
.B complete
|
|
.br
|
|
The LV is only activated if all devices are present.
|
|
|
|
.B degraded
|
|
.br
|
|
The LV is activated with missing devices if the RAID level can
|
|
tolerate the number of missing devices without LV data loss.
|
|
|
|
.B partial
|
|
.br
|
|
The LV is always activated, even if portions of the LV data are missing
|
|
because of the missing device(s). This should only be used to perform
|
|
recovery or repair operations.
|
|
|
|
.BR lvm.conf (5)
|
|
.B activation/activation_mode
|
|
.br
|
|
controls the activation mode when not specified by the command.
|
|
|
|
The default value is printed by:
|
|
.nf
|
|
lvmconfig --type default activation/activation_mode
|
|
.fi
|
|
|
|
.SS Replacing Devices
|
|
|
|
Devices in a RAID LV can be replaced with other devices in the VG. When
|
|
replacing devices that are no longer visible on the system, use lvconvert
|
|
\-\-repair. When replacing devices that are still visible, use lvconvert
|
|
\-\-replace. The repair command will attempt to restore the same number
|
|
of data LVs that were previously in the LV. The replace option can be
|
|
repeated to replace multiple PVs. Replacement devices can be optionally
|
|
listed with either option.
|
|
|
|
.B lvconvert \-\-repair
|
|
.IR VG / LV
|
|
[\fINewPVs\fP]
|
|
|
|
.B lvconvert \-\-replace
|
|
\fIOldPV\fP
|
|
.IR VG / LV
|
|
[\fINewPV\fP]
|
|
|
|
.B lvconvert
|
|
.B \-\-replace
|
|
\fIOldPV1\fP
|
|
.B \-\-replace
|
|
\fIOldPV2\fP
|
|
...
|
|
.IR VG / LV
|
|
[\fINewPVs\fP]
|
|
|
|
New devices require synchronization with existing devices, see
|
|
.BR Synchronization .
|
|
|
|
.SS Refreshing an LV
|
|
|
|
Refreshing a RAID LV clears any transient device failures (device was
|
|
temporarily disconnected) and returns the LV to its fully redundant mode.
|
|
Restoring a device will usually require at least partial synchronization
|
|
(see \fBSynchronization\fP). Failure to clear a transient failure results
|
|
in the RAID LV operating in degraded mode until it is reactivated. Use
|
|
the lvchange command to refresh an LV:
|
|
|
|
.B lvchange \-\-refresh
|
|
.IR VG / LV
|
|
|
|
.nf
|
|
# lvs -o name,vgname,segtype,attr,size vg
|
|
LV VG Type Attr LSize
|
|
raid1 vg raid1 Rwi-a-r-r- 100.00g
|
|
|
|
# lvchange --refresh vg/raid1
|
|
|
|
# lvs -o name,vgname,segtype,attr,size vg
|
|
LV VG Type Attr LSize
|
|
raid1 vg raid1 Rwi-a-r--- 100.00g
|
|
.fi
|
|
|
|
.SS Automatic repair
|
|
|
|
If a device in a RAID LV fails, device-mapper in the kernel notifies the
|
|
.BR dmeventd (8)
|
|
monitoring process (see \fBMonitoring\fP).
|
|
dmeventd can be configured to automatically respond using:
|
|
|
|
.BR lvm.conf (5)
|
|
.B activation/raid_fault_policy
|
|
|
|
Possible settings are:
|
|
|
|
.B warn
|
|
.br
|
|
A warning is added to the system log indicating that a device has
|
|
failed in the RAID LV. It is left to the user to repair the LV, e.g.
|
|
replace failed devices.
|
|
|
|
.B allocate
|
|
.br
|
|
dmeventd automatically attempts to repair the LV using spare devices
|
|
in the VG. Note that even a transient failure is handled as a permanent
|
|
failure; a new device is allocated and full synchronization is started.
|
|
|
|
The specific command run by dmeventd to warn or repair is:
|
|
.br
|
|
.B lvconvert \-\-repair \-\-use\-policies
|
|
.IR VG / LV
|
|
|
|
|
|
.SS Corrupted Data
|
|
|
|
Data on a device can be corrupted due to hardware errors, without the
|
|
device ever being disconnected, and without any fault in the software.
|
|
This should be rare, and can be detected (see \fBScrubbing\fP).
|
|
|
|
|
|
.SS Rebuild specific PVs
|
|
|
|
If specific PVs in a RAID LV are known to have corrupt data, the data on
|
|
those PVs can be reconstructed with:
|
|
|
|
.B lvchange \-\-rebuild PV
|
|
.IR VG / LV
|
|
|
|
The rebuild option can be repeated with different PVs to replace the data
|
|
on multiple PVs.
|
|
|
|
|
|
.SH Monitoring
|
|
|
|
When a RAID LV is activated the \fBdmeventd\fP(8) process is started to
|
|
monitor the health of the LV. Various events detected in the kernel can
|
|
cause a notification to be sent from device-mapper to the monitoring
|
|
process, including device failures and synchronization completion (e.g.
|
|
for initialization or scrubbing).
|
|
|
|
The LVM configuration file contains options that affect how the monitoring
|
|
process will respond to failure events (e.g. raid_fault_policy). It is
|
|
possible to turn on and off monitoring with lvchange, but it is not
|
|
recommended to turn this off unless you have a thorough knowledge of the
|
|
consequences.
|
|
|
|
|
|
.SH Configuration Options
|
|
|
|
There are a number of options in the LVM configuration file that affect
|
|
the behavior of RAID LVs. The tunable options are listed
|
|
below. A detailed description of each can be found in the LVM
|
|
configuration file itself.
|
|
.br
|
|
mirror_segtype_default
|
|
.br
|
|
raid10_segtype_default
|
|
.br
|
|
raid_region_size
|
|
.br
|
|
raid_fault_policy
|
|
.br
|
|
activation_mode
|
|
|
|
|
|
.SH RAID1 Tuning
|
|
|
|
A RAID1 LV can be tuned so that certain devices are avoided for reading
|
|
while all devices are still written to.
|
|
|
|
.B lvchange
|
|
.BR \-\- [ raid ] writemostly
|
|
.BR \fIPhysicalVolume [ : { y | n | t }]
|
|
.IR VG / LV
|
|
|
|
The specified device will be marked as "write mostly", which means that
|
|
reading from this device will be avoided, and other devices will be
|
|
preferred for reading (unless no other devices are available.) This
|
|
minimizes the I/O to the specified device.
|
|
|
|
If the PV name has no suffix, the write mostly attribute is set. If the
|
|
PV name has the suffix \fB:n\fP, the write mostly attribute is cleared,
|
|
and the suffix \fB:t\fP toggles the current setting.
|
|
|
|
The write mostly option can be repeated on the command line to change
|
|
multiple devices at once.
|
|
|
|
To report the current write mostly setting, the lvs attr field will show
|
|
the letter "w" in the 9th position when write mostly is set:
|
|
|
|
.B lvs -a -o name,attr
|
|
|
|
When a device is marked write mostly, the maximum number of outstanding
|
|
writes to that device can be configured. Once the maximum is reached,
|
|
further writes become synchronous. When synchronous, a write to the LV
|
|
will not complete until writes to all the mirror images are complete.
|
|
|
|
.B lvchange
|
|
.BR \-\- [ raid ] writebehind
|
|
.IR IOCount
|
|
.IR VG / LV
|
|
|
|
To report the current write behind setting, run:
|
|
|
|
.B lvs -o name,raid_write_behind
|
|
|
|
When write behind is not configured, or set to 0, all LV writes are
|
|
synchronous.
|
|
|
|
|
|
.SH RAID Takeover
|
|
|
|
RAID takeover is converting a RAID LV from one RAID level to another, e.g.
|
|
raid5 to raid6. Changing the RAID level is usually done to increase or
|
|
decrease resilience to device failures. This is done using lvconvert and
|
|
specifying the new RAID level as the LV type:
|
|
|
|
.B lvconvert --type
|
|
.I RaidLevel
|
|
\fIVG\fP/\fILV\fP
|
|
[\fIPVs\fP]
|
|
|
|
The most common and recommended RAID takeover conversions are:
|
|
|
|
.HP
|
|
\fBlinear\fP to \fBraid1\fP
|
|
.br
|
|
Linear is a single image of LV data, and
|
|
converting it to raid1 adds a mirror image which is a direct copy of the
|
|
original linear image.
|
|
|
|
.HP
|
|
\fBstriped\fP/\fBraid0\fP to \fBraid4/5/6\fP
|
|
.br
|
|
Adding parity devices to a
|
|
striped volume results in raid4/5/6.
|
|
|
|
.P
|
|
|
|
Unnatural conversions that are not recommended include converting between
|
|
striped and non-striped types. This is because file systems often
|
|
optimize I/O patterns based on device striping values. If those values
|
|
change, it can decrease performance.
|
|
|
|
Converting to a higher RAID level requires allocating new SubLVs to hold
|
|
RAID metadata, and new SubLVs to hold parity blocks for LV data.
|
|
Converting to a lower RAID level removes the SubLVs that are no longer
|
|
needed.
|
|
|
|
Conversion often requires full synchronization of the RAID LV (see
|
|
\fBSynchronization\fP). Converting to RAID1 requires copying all LV data
|
|
blocks to a new image on a new device. Converting to a parity RAID level
|
|
requires reading all LV data blocks, calculating parity, and writing the
|
|
new parity blocks. Synchronization can take a long time and degrade
|
|
performance (rate controls also apply to conversion, see
|
|
\fB\-\-maxrecoveryrate\fP.)
|
|
|
|
.P
|
|
|
|
The following takeover conversions are currently possible:
|
|
.br
|
|
.IP \(bu 3
|
|
between linear and raid1.
|
|
.IP \(bu 3
|
|
between striped and raid4.
|
|
|
|
.SS Examples
|
|
|
|
1. Converting an LV from \fBlinear\fP to \fBraid1\fP.
|
|
|
|
.nf
|
|
# lvs -a -o name,segtype,size vg
|
|
LV Type LSize
|
|
lv linear 300.00g
|
|
|
|
# lvconvert --type raid1 --mirrors 1 vg/lv
|
|
|
|
# lvs -a -o name,segtype,size vg
|
|
LV Type LSize
|
|
lv raid1 300.00g
|
|
[lv_rimage_0] linear 300.00g
|
|
[lv_rimage_1] linear 300.00g
|
|
[lv_rmeta_0] linear 3.00m
|
|
[lv_rmeta_1] linear 3.00m
|
|
.fi
|
|
|
|
2. Converting an LV from \fBmirror\fP to \fBraid1\fP.
|
|
|
|
.nf
|
|
# lvs -a -o name,segtype,size vg
|
|
LV Type LSize
|
|
lv mirror 100.00g
|
|
[lv_mimage_0] linear 100.00g
|
|
[lv_mimage_1] linear 100.00g
|
|
[lv_mlog] linear 3.00m
|
|
|
|
# lvconvert --type raid1 vg/lv
|
|
|
|
# lvs -a -o name,segtype,size vg
|
|
LV Type LSize
|
|
lv raid1 100.00g
|
|
[lv_rimage_0] linear 100.00g
|
|
[lv_rimage_1] linear 100.00g
|
|
[lv_rmeta_0] linear 3.00m
|
|
[lv_rmeta_1] linear 3.00m
|
|
.fi
|
|
|
|
3. Converting an LV from \fBlinear\fP to \fBraid1\fP (with 3 images).
|
|
|
|
.nf
|
|
Start with a linear LV:
|
|
|
|
# lvcreate -L1G -n my_lv vg
|
|
|
|
Convert the linear LV to raid1 with three images
|
|
(original linear image plus 2 mirror images):
|
|
|
|
# lvconvert --type raid1 --mirrors 2 vg/my_lv
|
|
.fi
|
|
|
|
.ig
|
|
4. Converting an LV from \fBstriped\fP (with 4 stripes) to \fBraid6_nc\fP.
|
|
|
|
.nf
|
|
Start with a striped LV:
|
|
|
|
# lvcreate --stripes 4 -L64M -n my_lv vg
|
|
|
|
Convert the striped LV to raid6_nc:
|
|
|
|
# lvconvert --type raid6_nc vg/my_lv
|
|
|
|
# lvs -a -o lv_name,segtype,sync_percent,data_copies
|
|
LV Type Cpy%Sync #Cpy
|
|
my_lv raid6_n_6 100.00 3
|
|
[my_lv_rimage_0] linear
|
|
[my_lv_rimage_1] linear
|
|
[my_lv_rimage_2] linear
|
|
[my_lv_rimage_3] linear
|
|
[my_lv_rimage_4] linear
|
|
[my_lv_rimage_5] linear
|
|
[my_lv_rmeta_0] linear
|
|
[my_lv_rmeta_1] linear
|
|
[my_lv_rmeta_2] linear
|
|
[my_lv_rmeta_3] linear
|
|
[my_lv_rmeta_4] linear
|
|
[my_lv_rmeta_5] linear
|
|
.fi
|
|
|
|
This convert begins by allocating MetaLVs (rmeta_#) for each of the
|
|
existing stripe devices. It then creates 2 additional MetaLV/DataLV pairs
|
|
(rmeta_#/rimage_#) for dedicated raid6 parity.
|
|
|
|
If rotating data/parity is required, such as with raid6_nr, it must be
|
|
done by reshaping (see below).
|
|
..
|
|
|
|
|
|
.SH RAID Reshaping
|
|
|
|
RAID reshaping is changing attributes of a RAID LV while keeping the same
|
|
RAID level, i.e. changes that do not involve changing the number of
|
|
devices. This includes changing RAID layout, stripe size, or number of
|
|
stripes.
|
|
|
|
When changing the RAID layout or stripe size, no new SubLVs (MetaLVs or
|
|
DataLVs) need to be allocated, but DataLVs are extended by a small amount
|
|
(typically 1 extent). The extra space allows blocks in a stripe to be
|
|
updated safely, and not corrupted in case of a crash. If a crash occurs,
|
|
reshaping can just be restarted.
|
|
|
|
(If blocks in a stripe were updated in place, a crash could leave them
|
|
partially updated and corrupted. Instead, an existing stripe is quiesced,
|
|
read, changed in layout, and the new stripe written to free space. Once
|
|
that is done, the new stripe is unquiesced and used.)
|
|
|
|
(The reshaping features are planned for a future release.)
|
|
|
|
.ig
|
|
.SS Examples
|
|
|
|
1. Converting raid6_n_6 to raid6_nr with rotating data/parity.
|
|
|
|
This conversion naturally follows a previous conversion from striped to
|
|
raid6_n_6 (shown above). It completes the transition to a more
|
|
traditional RAID6.
|
|
|
|
.nf
|
|
# lvs -o lv_name,segtype,sync_percent,data_copies
|
|
LV Type Cpy%Sync #Cpy
|
|
my_lv raid6_n_6 100.00 3
|
|
[my_lv_rimage_0] linear
|
|
[my_lv_rimage_1] linear
|
|
[my_lv_rimage_2] linear
|
|
[my_lv_rimage_3] linear
|
|
[my_lv_rimage_4] linear
|
|
[my_lv_rimage_5] linear
|
|
[my_lv_rmeta_0] linear
|
|
[my_lv_rmeta_1] linear
|
|
[my_lv_rmeta_2] linear
|
|
[my_lv_rmeta_3] linear
|
|
[my_lv_rmeta_4] linear
|
|
[my_lv_rmeta_5] linear
|
|
|
|
# lvconvert --type raid6_nr vg/my_lv
|
|
|
|
# lvs -a -o lv_name,segtype,sync_percent,data_copies
|
|
LV Type Cpy%Sync #Cpy
|
|
my_lv raid6_nr 100.00 3
|
|
[my_lv_rimage_0] linear
|
|
[my_lv_rimage_0] linear
|
|
[my_lv_rimage_1] linear
|
|
[my_lv_rimage_1] linear
|
|
[my_lv_rimage_2] linear
|
|
[my_lv_rimage_2] linear
|
|
[my_lv_rimage_3] linear
|
|
[my_lv_rimage_3] linear
|
|
[my_lv_rimage_4] linear
|
|
[my_lv_rimage_5] linear
|
|
[my_lv_rmeta_0] linear
|
|
[my_lv_rmeta_1] linear
|
|
[my_lv_rmeta_2] linear
|
|
[my_lv_rmeta_3] linear
|
|
[my_lv_rmeta_4] linear
|
|
[my_lv_rmeta_5] linear
|
|
.fi
|
|
|
|
The DataLVs are larger (additional segment in each) which provides space
|
|
for out-of-place reshaping. The result is:
|
|
|
|
FIXME: did the lv name change from my_lv to r?
|
|
.br
|
|
FIXME: should we change device names in the example to sda,sdb,sdc?
|
|
.br
|
|
FIXME: include -o devices or seg_pe_ranges above also?
|
|
|
|
.nf
|
|
# lvs -a -o lv_name,segtype,seg_pe_ranges,dataoffset
|
|
LV Type PE Ranges data
|
|
r raid6_nr r_rimage_0:0-32 \\
|
|
r_rimage_1:0-32 \\
|
|
r_rimage_2:0-32 \\
|
|
r_rimage_3:0-32
|
|
[r_rimage_0] linear /dev/sda:0-31 2048
|
|
[r_rimage_0] linear /dev/sda:33-33
|
|
[r_rimage_1] linear /dev/sdaa:0-31 2048
|
|
[r_rimage_1] linear /dev/sdaa:33-33
|
|
[r_rimage_2] linear /dev/sdab:1-33 2048
|
|
[r_rimage_3] linear /dev/sdac:1-33 2048
|
|
[r_rmeta_0] linear /dev/sda:32-32
|
|
[r_rmeta_1] linear /dev/sdaa:32-32
|
|
[r_rmeta_2] linear /dev/sdab:0-0
|
|
[r_rmeta_3] linear /dev/sdac:0-0
|
|
.fi
|
|
|
|
All segments with PE ranges '33-33' provide the out-of-place reshape space.
|
|
The dataoffset column shows that the data was moved from initial offset 0 to
|
|
2048 sectors on each component DataLV.
|
|
..
|
|
|
|
.SH RAID5 Variants
|
|
|
|
raid5_ls
|
|
.br
|
|
\[bu]
|
|
RAID5 left symmetric
|
|
.br
|
|
\[bu]
|
|
Rotating parity N with data restart
|
|
|
|
raid5_la
|
|
.br
|
|
\[bu]
|
|
RAID5 left symmetric
|
|
.br
|
|
\[bu]
|
|
Rotating parity N with data continuation
|
|
|
|
raid5_rs
|
|
.br
|
|
\[bu]
|
|
RAID5 right symmetric
|
|
.br
|
|
\[bu]
|
|
Rotating parity 0 with data restart
|
|
|
|
raid5_ra
|
|
.br
|
|
\[bu]
|
|
RAID5 right asymmetric
|
|
.br
|
|
\[bu]
|
|
Rotating parity 0 with data continuation
|
|
|
|
.ig
|
|
raid5_n
|
|
.br
|
|
\[bu]
|
|
RAID5 striping
|
|
.br
|
|
\[bu]
|
|
Same layout as raid4 with a dedicated parity N with striped data.
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
..
|
|
|
|
.SH RAID6 Variants
|
|
|
|
raid6
|
|
.br
|
|
\[bu]
|
|
RAID6 zero restart (aka left symmetric)
|
|
.br
|
|
\[bu]
|
|
Rotating parity 0 with data restart
|
|
.br
|
|
\[bu]
|
|
Same as raid6_zr
|
|
|
|
raid6_zr
|
|
.br
|
|
\[bu]
|
|
RAID6 zero restart (aka left symmetric)
|
|
.br
|
|
\[bu]
|
|
Rotating parity 0 with data restart
|
|
|
|
raid6_nr
|
|
.br
|
|
\[bu]
|
|
RAID6 N restart (aka right symmetric)
|
|
.br
|
|
\[bu]
|
|
Rotating parity N with data restart
|
|
|
|
raid6_nc
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Rotating parity N with data continuation
|
|
|
|
.ig
|
|
raid6_n_6
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Fixed P-Syndrome N-1 and Q-Syndrome N with striped data
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
|
|
raid6_ls_6
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Same as raid5_ls for N-1 disks with fixed Q-Syndrome N
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
|
|
raid6_la_6
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Same as raid5_la for N-1 disks with fixed Q-Syndrome N
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
|
|
raid6_rs_6
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Same as raid5_rs for N-1 disks with fixed Q-Syndrome N
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
|
|
raid6_ra_6
|
|
.br
|
|
\[bu]
|
|
RAID6 N continue
|
|
.br
|
|
\[bu]
|
|
Same as raid5_ra for N-1 disks with fixed Q-Syndrome N
|
|
.br
|
|
\[bu]
|
|
Used for
|
|
.B RAID Takeover
|
|
..
|
|
|
|
|
|
.ig
|
|
.SH RAID Duplication
|
|
|
|
RAID LV conversion (takeover or reshaping) can be done out\-of\-place by
|
|
copying the LV data onto new devices while changing the RAID properties.
|
|
Copying avoids modifying the original LV but requires additional devices.
|
|
Once the LV data has been copied/converted onto the new devices, there are
|
|
multiple options:
|
|
|
|
1. The RAID LV can be switched over to run from just the new devices, and
|
|
the original copy of the data removed. The converted LV then has the new
|
|
RAID properties, and exists on new devices. The old devices holding the
|
|
original data can be removed or reused.
|
|
|
|
2. The new copy of the data can be dropped, leaving the original RAID LV
|
|
unchanged and using its original devices.
|
|
|
|
3. The new copy of the data can be separated and used as a new independent
|
|
LV, leaving the original RAID LV unchanged on its original devices.
|
|
|
|
The command to start duplication is:
|
|
|
|
.B lvconvert \-\-type
|
|
.I RaidLevel
|
|
[\fB\-\-stripes\fP \fINumber\fP \fB\-\-stripesize\fP \fISize\fP]
|
|
.RS
|
|
.B \-\-duplicate
|
|
.IR VG / LV
|
|
[\fIPVs\fP]
|
|
.RE
|
|
|
|
.HP
|
|
.B \-\-duplicate
|
|
.br
|
|
Specifies that the LV conversion should be done out\-of\-place, copying
|
|
LV data to new devices while converting.
|
|
|
|
.HP
|
|
.BR \-\-type , \-\-stripes , \-\-stripesize
|
|
.br
|
|
Specifies the RAID properties to use when creating the copy.
|
|
|
|
.P
|
|
\fIPVs\fP specifies the new devices to use.
|
|
|
|
The steps in the duplication process:
|
|
|
|
.IP \(bu 3
|
|
LVM creates a new LV on new devices using the specified RAID properties
|
|
(type, stripes, etc) and optionally specified devices.
|
|
|
|
.IP \(bu 3
|
|
LVM changes the visible RAID LV to type raid1, making the original LV the
|
|
first raid1 image (SubLV 0), and the new LV the second raid1 image
|
|
(SubLV 1).
|
|
|
|
.IP \(bu 3
|
|
The RAID1 synchronization process copies data from the original LV
|
|
image (SubLV 0) to the new LV image (SubLV 1).
|
|
|
|
.IP \(bu 3
|
|
When synchronization is complete, the original and new LVs are
|
|
mirror images of each other and can be separated.
|
|
|
|
.P
|
|
|
|
The duplication process retains both the original and new LVs (both
|
|
SubLVs) until an explicit unduplicate command is run to separate them. The
|
|
unduplicate command specifies if the original LV should use the old
|
|
devices (SubLV 0) or the new devices (SubLV 1).
|
|
|
|
To make the RAID LV use the data on the old devices, and drop the copy on
|
|
the new devices, specify the name of SubLV 0 (suffix _dup_0):
|
|
|
|
.B lvconvert \-\-unduplicate
|
|
.BI \-\-name
|
|
.IB LV _dup_0
|
|
.IR VG / LV
|
|
|
|
To make the RAID LV use the data copy on the new devices, and drop the old
|
|
devices, specify the name of SubLV 1 (suffix _dup_1):
|
|
|
|
.B lvconvert \-\-unduplicate
|
|
.BI \-\-name
|
|
.IB LV _dup_1
|
|
.IR VG / LV
|
|
|
|
FIXME: To make the LV use the data on the original devices, but keep the
|
|
data copy as a new LV, ...
|
|
|
|
FIXME: include how splitmirrors can be used.
|
|
|
|
|
|
.SH RAID1E
|
|
|
|
TODO
|
|
..
|
|
|
|
.SH History
|
|
|
|
The 2.6.38-rc1 version of the Linux kernel introduced a device-mapper
|
|
target to interface with the software RAID (MD) personalities. This
|
|
provided device-mapper with RAID 4/5/6 capabilities and a larger
|
|
development community. Later, support for RAID1, RAID10, and RAID1E (RAID
|
|
10 variants) were added. Support for these new kernel RAID targets was
|
|
added to LVM version 2.02.87. The capabilities of the LVM \fBraid1\fP
|
|
type have surpassed the old \fBmirror\fP type. raid1 is now recommended
|
|
instead of mirror. raid1 became the default for mirroring in LVM version
|
|
2.02.100.
|
|
|