1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
lvm2/daemons/lvmdbusd/background.py
Tony Asleson 699ccc05ca lvmdbusd: Add background command to flight recorder
We were not adding background tasks to flight recorder.  Add the meta
data to the flight recorder when we start the command and update the meta
data when the command is finished.  Locking was added to meta data to
prevent concurrent update and returning string representation as these can
happen in two different threads.
2017-06-02 12:32:51 -05:00

163 lines
4.8 KiB
Python

# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
#
# This copyrighted material is made available to anyone wishing to use,
# modify, copy, or redistribute it subject to the terms and conditions
# of the GNU General Public License v.2.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
import subprocess
from . import cfg
from .cmdhandler import options_to_cli_args, LvmExecutionMeta
import dbus
from .utils import pv_range_append, pv_dest_ranges, log_error, log_debug,\
add_no_notify
import os
import threading
import time
def pv_move_lv_cmd(move_options, lv_full_name,
pv_source, pv_source_range, pv_dest_range_list):
cmd = ['pvmove', '-i', '1']
cmd.extend(options_to_cli_args(move_options))
if lv_full_name:
cmd.extend(['-n', lv_full_name])
pv_range_append(cmd, pv_source, *pv_source_range)
pv_dest_ranges(cmd, pv_dest_range_list)
return cmd
def lv_merge_cmd(merge_options, lv_full_name):
cmd = ['lvconvert', '--merge', '-i', '1']
cmd.extend(options_to_cli_args(merge_options))
cmd.append(lv_full_name)
return cmd
def _move_merge(interface_name, command, job_state):
# We need to execute these command stand alone by forking & exec'ing
# the command always as we will be getting periodic output from them on
# the status of the long running operation.
command.insert(0, cfg.LVM_CMD)
# Instruct lvm to not register an event with us
command = add_no_notify(command)
#(self, start, ended, cmd, ec, stdout_txt, stderr_txt)
meta = LvmExecutionMeta(time.time(), 0, command, -1000, None, None)
cfg.blackbox.add(meta)
process = subprocess.Popen(command, stdout=subprocess.PIPE,
env=os.environ,
stderr=subprocess.PIPE, close_fds=True)
log_debug("Background process for %s is %d" %
(str(command), process.pid))
lines_iterator = iter(process.stdout.readline, b"")
for line in lines_iterator:
line_str = line.decode("utf-8")
# Check to see if the line has the correct number of separators
try:
if line_str.count(':') == 2:
(device, ignore, percentage) = line_str.split(':')
job_state.Percent = round(
float(percentage.strip()[:-1]), 1)
# While the move is in progress we need to periodically update
# the state to reflect where everything is at.
cfg.load()
except ValueError:
log_error("Trying to parse percentage which failed for %s" %
line_str)
out = process.communicate()
with meta.lock:
meta.ended = time.time()
meta.ec = process.returncode
meta.stderr_txt = out[1]
if process.returncode == 0:
job_state.Percent = 100
else:
raise dbus.exceptions.DBusException(
interface_name,
'Exit code %s, stderr = %s' % (str(process.returncode), out[1]))
cfg.load()
return '/'
def move(interface_name, lv_name, pv_src_obj, pv_source_range,
pv_dests_and_ranges, move_options, job_state):
"""
Common code for the pvmove handling.
:param interface_name: What dbus interface we are providing for
:param lv_name: Optional (None or name of LV to move)
:param pv_src_obj: dbus object patch for source PV
:param pv_source_range: (0,0 to ignore, else start, end segments)
:param pv_dests_and_ranges: Array of PV object paths and start/end segs
:param move_options: Hash with optional arguments
:param job_state: Used to convey information about jobs between processes
:return: '/' When complete, the empty object path
"""
pv_dests = []
pv_src = cfg.om.get_object_by_path(pv_src_obj)
if pv_src:
# Check to see if we are handling a move to a specific
# destination(s)
if len(pv_dests_and_ranges):
for pr in pv_dests_and_ranges:
pv_dbus_obj = cfg.om.get_object_by_path(pr[0])
if not pv_dbus_obj:
raise dbus.exceptions.DBusException(
interface_name,
'PV Destination (%s) not found' % pr[0])
pv_dests.append((pv_dbus_obj.lvm_id, pr[1], pr[2]))
cmd = pv_move_lv_cmd(move_options,
lv_name,
pv_src.lvm_id,
pv_source_range,
pv_dests)
return _move_merge(interface_name, cmd, job_state)
else:
raise dbus.exceptions.DBusException(
interface_name, 'pv_src_obj (%s) not found' % pv_src_obj)
def merge(interface_name, lv_uuid, lv_name, merge_options, job_state):
# Make sure we have a dbus object representing it
dbo = cfg.om.get_object_by_uuid_lvm_id(lv_uuid, lv_name)
if dbo:
cmd = lv_merge_cmd(merge_options, dbo.lvm_id)
return _move_merge(interface_name, cmd, job_state)
else:
raise dbus.exceptions.DBusException(
interface_name,
'LV with uuid %s and name %s not present!' % (lv_uuid, lv_name))
def _run_cmd(req):
log_debug(
"_run_cmd: Running method: %s with args %s" %
(str(req.method), str(req.arguments)))
req.run_cmd()
log_debug("_run_cmd: complete!")
def cmd_runner(request):
t = threading.Thread(target=_run_cmd, args=(request,))
t.start()