1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-21 13:34:40 +03:00
lvm2/tools/pvresize.c
David Teigland 2d5dc6512e dbus: add notification from commands
When a command modifies a PV or VG, or changes the
activation state of an LV, it will send a dbus
notification when the command is finished.  This
can be enabled/disabled with a config setting.
2016-03-07 10:06:09 -06:00

101 lines
2.5 KiB
C

/*
* Copyright (C) 2001-2004 Sistina Software, Inc. All rights reserved.
* Copyright (C) 2004-2005 Red Hat, Inc. All rights reserved.
* Copyright (C) 2005 Zak Kipling. All rights reserved.
*
* This file is part of LVM2.
*
* This copyrighted material is made available to anyone wishing to use,
* modify, copy, or redistribute it subject to the terms and conditions
* of the GNU Lesser General Public License v.2.1.
*
* You should have received a copy of the GNU Lesser General Public License
* along with this program; if not, write to the Free Software Foundation,
* Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA
*/
#include "tools.h"
struct pvresize_params {
uint64_t new_size;
unsigned done;
unsigned total;
};
static int _pvresize_single(struct cmd_context *cmd,
struct volume_group *vg,
struct physical_volume *pv,
struct processing_handle *handle)
{
struct pvresize_params *params = (struct pvresize_params *) handle->custom_handle;
if (!params) {
log_error(INTERNAL_ERROR "Invalid resize params.");
return ECMD_FAILED;
}
params->total++;
/*
* Needed to change a property on an orphan PV.
* i.e. the global lock is only needed for orphans.
* Convert sh to ex.
*/
if (is_orphan(pv)) {
if (!lockd_gl(cmd, "ex", 0))
return_ECMD_FAILED;
cmd->lockd_gl_disable = 1;
}
if (!pv_resize_single(cmd, vg, pv, params->new_size))
return_ECMD_FAILED;
params->done++;
return ECMD_PROCESSED;
}
int pvresize(struct cmd_context *cmd, int argc, char **argv)
{
struct pvresize_params params;
struct processing_handle *handle = NULL;
int ret;
if (!argc) {
log_error("Please supply physical volume(s)");
ret = EINVALID_CMD_LINE;
goto out;
}
if (arg_sign_value(cmd, physicalvolumesize_ARG, SIGN_NONE) == SIGN_MINUS) {
log_error("Physical volume size may not be negative");
ret = EINVALID_CMD_LINE;
goto out;
}
params.new_size = arg_uint64_value(cmd, physicalvolumesize_ARG,
UINT64_C(0));
params.done = 0;
params.total = 0;
set_pv_notify(cmd);
if (!(handle = init_processing_handle(cmd))) {
log_error("Failed to initialize processing handle.");
ret = ECMD_FAILED;
goto out;
}
handle->custom_handle = &params;
ret = process_each_pv(cmd, argc, argv, NULL, 0, READ_FOR_UPDATE, handle,
_pvresize_single);
log_print_unless_silent("%d physical volume(s) resized / %d physical volume(s) "
"not resized", params.done, params.total - params.done);
out:
destroy_processing_handle(cmd, handle);
return ret;
}