1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
lvm2/daemons/lvmdbusd/manager.py
Tony Asleson 8a1c73ddbe lvmdbusd: Always leverage udev
Previously we utilized udev until we got a dbus notification from lvm
command line tools.  This however misses the case where something outside
of lvm clears the signatures on a block device and we fail to refresh the
state of the daemon.  Change the behavior so we always monitor udev events,
but ignore those udev events that pertain to lvm members.

Note: --udev command line option no longer does anything and simply
outputs a message that it's no longer used.

Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1967171
2022-10-20 15:10:35 -05:00

264 lines
7.5 KiB
Python

# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
#
# This copyrighted material is made available to anyone wishing to use,
# modify, copy, or redistribute it subject to the terms and conditions
# of the GNU General Public License v.2.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
from .automatedproperties import AutomatedProperties
from . import utils
from .cfg import MANAGER_INTERFACE
import dbus
from . import cfg
from . import cmdhandler
from .request import RequestEntry
from . import udevwatch
# noinspection PyPep8Naming
class Manager(AutomatedProperties):
_Version_meta = ("s", MANAGER_INTERFACE)
def __init__(self, object_path):
super(Manager, self).__init__(object_path)
self.set_interface(MANAGER_INTERFACE)
@property
def Version(self):
return dbus.String('1.1.0')
@staticmethod
def handle_execute(rc, out, err):
if rc == 0:
cfg.load()
else:
# Need to work on error handling, need consistent
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE,
'Exit code %s, stderr = %s' % (str(rc), err))
@staticmethod
def _pv_create(device, create_options):
# Check to see if we are already trying to create a PV for an existing
# PV
pv = cfg.om.get_object_path_by_uuid_lvm_id(device, device)
if pv:
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE, "PV %s Already exists!" % device)
rc, out, err = cmdhandler.pv_create(create_options, [device])
Manager.handle_execute(rc, out, err)
return cfg.om.get_object_path_by_lvm_id(device)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='sia{sv}',
out_signature='(oo)',
async_callbacks=('cb', 'cbe'))
def PvCreate(self, device, tmo, create_options, cb, cbe):
utils.validate_device_path(MANAGER_INTERFACE, device)
r = RequestEntry(
tmo, Manager._pv_create,
(device, create_options), cb, cbe)
cfg.worker_q.put(r)
@staticmethod
def _create_vg(name, pv_object_paths, create_options):
pv_devices = []
for p in pv_object_paths:
pv = cfg.om.get_object_by_path(p)
if pv:
pv_devices.append(pv.Name)
else:
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE, 'object path = %s not found' % p)
rc, out, err = cmdhandler.vg_create(create_options, pv_devices, name)
Manager.handle_execute(rc, out, err)
return cfg.om.get_object_path_by_lvm_id(name)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='saoia{sv}',
out_signature='(oo)',
async_callbacks=('cb', 'cbe'))
def VgCreate(self, name, pv_object_paths, tmo, create_options, cb, cbe):
utils.validate_vg_name(MANAGER_INTERFACE, name)
r = RequestEntry(
tmo, Manager._create_vg,
(name, pv_object_paths, create_options,),
cb, cbe)
cfg.worker_q.put(r)
@staticmethod
def _refresh():
utils.log_debug('Manager.Refresh - entry')
# This is a diagnostic and should not be run in normal operation, so
# lets remove the log entries for refresh as it's implied.
# Run an internal diagnostic on the object manager look up tables
lc = cfg.om.validate_lookups()
rc = cfg.load(log=False)
if rc != 0:
utils.log_debug('Manager.Refresh - exit %d %d' % (rc, lc),
'bg_black', 'fg_light_red')
else:
utils.log_debug('Manager.Refresh - exit %d %d' % (rc, lc))
return rc + lc
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
out_signature='t',
async_callbacks=('cb', 'cbe'))
def Refresh(self, cb, cbe):
"""
Take all the objects we know about and go out and grab the latest
more of a test method at the moment to make sure we are handling object
paths correctly.
:param cb Callback for result
:param cbe Callback for errors
Returns the number of changes, object add/remove/properties changed
"""
r = RequestEntry(-1, Manager._refresh, (), cb, cbe, False)
cfg.worker_q.put(r)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE)
def FlightRecorderDump(self):
"""
Dump the flight recorder to syslog
"""
cfg.debug.dump()
cfg.flightrecorder.dump()
@staticmethod
def _lookup_by_lvm_id(key):
p = cfg.om.get_object_path_by_uuid_lvm_id(key, key)
if not p:
p = '/'
utils.log_debug('LookUpByLvmId: key = %s, result = %s' % (key, p))
return p
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='s',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def LookUpByLvmId(self, key, cb, cbe):
"""
Given a lvm id in one of the forms:
/dev/sda
some_vg
some_vg/some_lv
Oe1rPX-Pf0W-15E5-n41N-ZmtF-jXS0-Osg8fn
return the object path in O(1) time.
:param key: The lookup value
:param cb: dbus python call back parameter, not client visible
:param cbe: dbus python error call back parameter, not client visible
:return: Return the object path. If object not found you will get '/'
"""
r = RequestEntry(-1, Manager._lookup_by_lvm_id, (key,), cb, cbe, False)
cfg.worker_q.put(r)
@staticmethod
def _use_lvm_shell(yes_no):
return dbus.Boolean(cmdhandler.set_execution(yes_no))
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='b', out_signature='b',
async_callbacks=('cb', 'cbe'))
def UseLvmShell(self, yes_no, cb, cbe):
"""
Allow the client to enable/disable lvm shell, used for testing
:param yes_no:
:param cb: dbus python call back parameter, not client visible
:param cbe: dbus python error call back parameter, not client visible
:return: Boolean
"""
r = RequestEntry(-1, Manager._use_lvm_shell, (yes_no,), cb, cbe, False)
cfg.worker_q.put(r)
@staticmethod
def _external_event(command):
utils.log_debug("Processing _external_event= %s" % command,
'bg_black', 'fg_orange')
cfg.got_external_event = True
cfg.load()
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='s', out_signature='i')
def ExternalEvent(self, command):
utils.log_debug("ExternalEvent %s" % command)
r = RequestEntry(
-1, Manager._external_event, (command,), None, None, False)
cfg.worker_q.put(r)
return dbus.Int32(0)
@staticmethod
def _pv_scan(activate, cache, device_path, major_minor, scan_options):
rc, out, err = cmdhandler.pv_scan(
activate, cache, device_path,
major_minor, scan_options)
Manager.handle_execute(rc, out, err)
return '/'
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='bbasa(ii)ia{sv}',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def PvScan(self, activate, cache, device_paths, major_minors,
tmo, scan_options, cb, cbe):
"""
Scan all supported LVM block devices in the system for physical volumes
NOTE: major_minors & device_paths only usable when cache == True
:param activate: If True, activate any newly found LVs
:param cache: If True, update lvmetad
:param device_paths: Array of device paths or empty
:param major_minors: Array of structures (major,minor)
:param tmo: Timeout for operation
:param scan_options: Additional options to pvscan
:param cb: Not visible in API (used for async. callback)
:param cbe: Not visible in API (used for async. error callback)
:return: '/' if operation done, else job path
"""
for d in device_paths:
utils.validate_device_path(MANAGER_INTERFACE, d)
r = RequestEntry(
tmo, Manager._pv_scan,
(activate, cache, device_paths, major_minors,
scan_options), cb, cbe, False)
cfg.worker_q.put(r)
@property
def lvm_id(self):
"""
Intended to be overridden by classes that inherit
"""
return str(id(self))
@property
def Uuid(self):
"""
Intended to be overridden by classes that inherit
"""
import uuid
return uuid.uuid1()