mirror of
git://sourceware.org/git/lvm2.git
synced 2024-12-22 17:35:59 +03:00
8a1c73ddbe
Previously we utilized udev until we got a dbus notification from lvm command line tools. This however misses the case where something outside of lvm clears the signatures on a block device and we fail to refresh the state of the daemon. Change the behavior so we always monitor udev events, but ignore those udev events that pertain to lvm members. Note: --udev command line option no longer does anything and simply outputs a message that it's no longer used. Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1967171
264 lines
7.5 KiB
Python
264 lines
7.5 KiB
Python
# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
|
|
#
|
|
# This copyrighted material is made available to anyone wishing to use,
|
|
# modify, copy, or redistribute it subject to the terms and conditions
|
|
# of the GNU General Public License v.2.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
from .automatedproperties import AutomatedProperties
|
|
|
|
from . import utils
|
|
from .cfg import MANAGER_INTERFACE
|
|
import dbus
|
|
from . import cfg
|
|
from . import cmdhandler
|
|
from .request import RequestEntry
|
|
from . import udevwatch
|
|
|
|
|
|
# noinspection PyPep8Naming
|
|
class Manager(AutomatedProperties):
|
|
_Version_meta = ("s", MANAGER_INTERFACE)
|
|
|
|
def __init__(self, object_path):
|
|
super(Manager, self).__init__(object_path)
|
|
self.set_interface(MANAGER_INTERFACE)
|
|
|
|
@property
|
|
def Version(self):
|
|
return dbus.String('1.1.0')
|
|
|
|
@staticmethod
|
|
def handle_execute(rc, out, err):
|
|
if rc == 0:
|
|
cfg.load()
|
|
else:
|
|
# Need to work on error handling, need consistent
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE,
|
|
'Exit code %s, stderr = %s' % (str(rc), err))
|
|
|
|
@staticmethod
|
|
def _pv_create(device, create_options):
|
|
|
|
# Check to see if we are already trying to create a PV for an existing
|
|
# PV
|
|
pv = cfg.om.get_object_path_by_uuid_lvm_id(device, device)
|
|
if pv:
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE, "PV %s Already exists!" % device)
|
|
|
|
rc, out, err = cmdhandler.pv_create(create_options, [device])
|
|
Manager.handle_execute(rc, out, err)
|
|
return cfg.om.get_object_path_by_lvm_id(device)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='sia{sv}',
|
|
out_signature='(oo)',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def PvCreate(self, device, tmo, create_options, cb, cbe):
|
|
utils.validate_device_path(MANAGER_INTERFACE, device)
|
|
r = RequestEntry(
|
|
tmo, Manager._pv_create,
|
|
(device, create_options), cb, cbe)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _create_vg(name, pv_object_paths, create_options):
|
|
pv_devices = []
|
|
|
|
for p in pv_object_paths:
|
|
pv = cfg.om.get_object_by_path(p)
|
|
if pv:
|
|
pv_devices.append(pv.Name)
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE, 'object path = %s not found' % p)
|
|
|
|
rc, out, err = cmdhandler.vg_create(create_options, pv_devices, name)
|
|
Manager.handle_execute(rc, out, err)
|
|
return cfg.om.get_object_path_by_lvm_id(name)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='saoia{sv}',
|
|
out_signature='(oo)',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def VgCreate(self, name, pv_object_paths, tmo, create_options, cb, cbe):
|
|
utils.validate_vg_name(MANAGER_INTERFACE, name)
|
|
r = RequestEntry(
|
|
tmo, Manager._create_vg,
|
|
(name, pv_object_paths, create_options,),
|
|
cb, cbe)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _refresh():
|
|
utils.log_debug('Manager.Refresh - entry')
|
|
|
|
# This is a diagnostic and should not be run in normal operation, so
|
|
# lets remove the log entries for refresh as it's implied.
|
|
|
|
# Run an internal diagnostic on the object manager look up tables
|
|
lc = cfg.om.validate_lookups()
|
|
|
|
rc = cfg.load(log=False)
|
|
|
|
if rc != 0:
|
|
utils.log_debug('Manager.Refresh - exit %d %d' % (rc, lc),
|
|
'bg_black', 'fg_light_red')
|
|
else:
|
|
utils.log_debug('Manager.Refresh - exit %d %d' % (rc, lc))
|
|
return rc + lc
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
out_signature='t',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def Refresh(self, cb, cbe):
|
|
"""
|
|
Take all the objects we know about and go out and grab the latest
|
|
more of a test method at the moment to make sure we are handling object
|
|
paths correctly.
|
|
|
|
:param cb Callback for result
|
|
:param cbe Callback for errors
|
|
|
|
Returns the number of changes, object add/remove/properties changed
|
|
"""
|
|
r = RequestEntry(-1, Manager._refresh, (), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE)
|
|
def FlightRecorderDump(self):
|
|
"""
|
|
Dump the flight recorder to syslog
|
|
"""
|
|
cfg.debug.dump()
|
|
cfg.flightrecorder.dump()
|
|
|
|
@staticmethod
|
|
def _lookup_by_lvm_id(key):
|
|
p = cfg.om.get_object_path_by_uuid_lvm_id(key, key)
|
|
if not p:
|
|
p = '/'
|
|
utils.log_debug('LookUpByLvmId: key = %s, result = %s' % (key, p))
|
|
return p
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='s',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def LookUpByLvmId(self, key, cb, cbe):
|
|
"""
|
|
Given a lvm id in one of the forms:
|
|
|
|
/dev/sda
|
|
some_vg
|
|
some_vg/some_lv
|
|
Oe1rPX-Pf0W-15E5-n41N-ZmtF-jXS0-Osg8fn
|
|
|
|
return the object path in O(1) time.
|
|
|
|
:param key: The lookup value
|
|
:param cb: dbus python call back parameter, not client visible
|
|
:param cbe: dbus python error call back parameter, not client visible
|
|
:return: Return the object path. If object not found you will get '/'
|
|
"""
|
|
r = RequestEntry(-1, Manager._lookup_by_lvm_id, (key,), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _use_lvm_shell(yes_no):
|
|
return dbus.Boolean(cmdhandler.set_execution(yes_no))
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='b', out_signature='b',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def UseLvmShell(self, yes_no, cb, cbe):
|
|
"""
|
|
Allow the client to enable/disable lvm shell, used for testing
|
|
:param yes_no:
|
|
:param cb: dbus python call back parameter, not client visible
|
|
:param cbe: dbus python error call back parameter, not client visible
|
|
:return: Boolean
|
|
"""
|
|
r = RequestEntry(-1, Manager._use_lvm_shell, (yes_no,), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _external_event(command):
|
|
utils.log_debug("Processing _external_event= %s" % command,
|
|
'bg_black', 'fg_orange')
|
|
cfg.got_external_event = True
|
|
cfg.load()
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='s', out_signature='i')
|
|
def ExternalEvent(self, command):
|
|
utils.log_debug("ExternalEvent %s" % command)
|
|
r = RequestEntry(
|
|
-1, Manager._external_event, (command,), None, None, False)
|
|
cfg.worker_q.put(r)
|
|
return dbus.Int32(0)
|
|
|
|
@staticmethod
|
|
def _pv_scan(activate, cache, device_path, major_minor, scan_options):
|
|
|
|
rc, out, err = cmdhandler.pv_scan(
|
|
activate, cache, device_path,
|
|
major_minor, scan_options)
|
|
|
|
Manager.handle_execute(rc, out, err)
|
|
return '/'
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='bbasa(ii)ia{sv}',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def PvScan(self, activate, cache, device_paths, major_minors,
|
|
tmo, scan_options, cb, cbe):
|
|
"""
|
|
Scan all supported LVM block devices in the system for physical volumes
|
|
NOTE: major_minors & device_paths only usable when cache == True
|
|
:param activate: If True, activate any newly found LVs
|
|
:param cache: If True, update lvmetad
|
|
:param device_paths: Array of device paths or empty
|
|
:param major_minors: Array of structures (major,minor)
|
|
:param tmo: Timeout for operation
|
|
:param scan_options: Additional options to pvscan
|
|
:param cb: Not visible in API (used for async. callback)
|
|
:param cbe: Not visible in API (used for async. error callback)
|
|
:return: '/' if operation done, else job path
|
|
"""
|
|
for d in device_paths:
|
|
utils.validate_device_path(MANAGER_INTERFACE, d)
|
|
|
|
r = RequestEntry(
|
|
tmo, Manager._pv_scan,
|
|
(activate, cache, device_paths, major_minors,
|
|
scan_options), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@property
|
|
def lvm_id(self):
|
|
"""
|
|
Intended to be overridden by classes that inherit
|
|
"""
|
|
return str(id(self))
|
|
|
|
@property
|
|
def Uuid(self):
|
|
"""
|
|
Intended to be overridden by classes that inherit
|
|
"""
|
|
import uuid
|
|
return uuid.uuid1()
|