mirror of
git://sourceware.org/git/lvm2.git
synced 2024-12-21 13:34:40 +03:00
bb45e33518
Previously there have been necessary explicit call of backup (often either forgotten or over-used). With this patch the necessity to store backup is remember at vg_commit and once the VG is unlocked, the committed metadata are automatically store in backup file. This may possibly alter some printed messages from command when the backup is now taken later.
268 lines
6.4 KiB
C
268 lines
6.4 KiB
C
/*
|
|
* Copyright (C) 2001-2004 Sistina Software, Inc. All rights reserved.
|
|
* Copyright (C) 2004-2009 Red Hat, Inc. All rights reserved.
|
|
*
|
|
* This file is part of LVM2.
|
|
*
|
|
* This copyrighted material is made available to anyone wishing to use,
|
|
* modify, copy, or redistribute it subject to the terms and conditions
|
|
* of the GNU Lesser General Public License v.2.1.
|
|
*
|
|
* You should have received a copy of the GNU Lesser General Public License
|
|
* along with this program; if not, write to the Free Software Foundation,
|
|
* Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA
|
|
*/
|
|
|
|
#include "tools.h"
|
|
|
|
struct vgreduce_params {
|
|
int force;
|
|
int fixed;
|
|
int already_consistent;
|
|
};
|
|
|
|
static int _remove_pv(struct volume_group *vg, struct pv_list *pvl, int silent)
|
|
{
|
|
char uuid[64] __attribute__((aligned(8)));
|
|
|
|
if (vg->pv_count == 1) {
|
|
log_error("Volume Groups must always contain at least one PV.");
|
|
return 0;
|
|
}
|
|
|
|
if (!id_write_format(&pvl->pv->id, uuid, sizeof(uuid)))
|
|
return_0;
|
|
|
|
log_verbose("Removing PV with UUID %s from VG %s.", uuid, vg->name);
|
|
|
|
if (pvl->pv->pe_alloc_count) {
|
|
if (!silent)
|
|
log_error("LVs still present on PV with UUID %s: "
|
|
"Can't remove from VG %s.", uuid, vg->name);
|
|
return 0;
|
|
}
|
|
|
|
vg->free_count -= pvl->pv->pe_count;
|
|
vg->extent_count -= pvl->pv->pe_count;
|
|
del_pvl_from_vgs(vg, pvl);
|
|
free_pv_fid(pvl->pv);
|
|
|
|
return 1;
|
|
}
|
|
|
|
static int _consolidate_vg(struct cmd_context *cmd, struct volume_group *vg)
|
|
{
|
|
struct pv_list *pvl;
|
|
struct lv_list *lvl;
|
|
int r = 1;
|
|
|
|
dm_list_iterate_items(lvl, &vg->lvs)
|
|
if (lv_is_partial(lvl->lv)) {
|
|
log_warn("WARNING: Partial LV %s needs to be repaired "
|
|
"or removed. ", lvl->lv->name);
|
|
r = 0;
|
|
}
|
|
|
|
if (!r) {
|
|
cmd->handles_missing_pvs = 1;
|
|
log_error("There are still partial LVs in VG %s.", vg->name);
|
|
log_error("To remove them unconditionally use: vgreduce --removemissing --force.");
|
|
log_error("To remove them unconditionally from mirror LVs use: vgreduce"
|
|
" --removemissing --mirrorsonly --force.");
|
|
log_warn("WARNING: Proceeding to remove empty missing PVs.");
|
|
}
|
|
|
|
dm_list_iterate_items(pvl, &vg->pvs) {
|
|
if (pvl->pv->dev && !is_missing_pv(pvl->pv))
|
|
continue;
|
|
if (r && !_remove_pv(vg, pvl, 0))
|
|
return_0;
|
|
}
|
|
|
|
return r;
|
|
}
|
|
|
|
static int _make_vg_consistent(struct cmd_context *cmd, struct volume_group *vg)
|
|
{
|
|
struct lv_list *lvl;
|
|
struct logical_volume *lv;
|
|
|
|
cmd->partial_activation = 1;
|
|
|
|
restart:
|
|
vg_mark_partial_lvs(vg, 1);
|
|
|
|
dm_list_iterate_items(lvl, &vg->lvs) {
|
|
lv = lvl->lv;
|
|
|
|
/* Are any segments of this LV on missing PVs? */
|
|
if (lv_is_partial(lv)) {
|
|
if (seg_is_raid(first_seg(lv))) {
|
|
if (!lv_raid_remove_missing(lv))
|
|
return_0;
|
|
goto restart;
|
|
}
|
|
|
|
if (lv_is_mirror(lv)) {
|
|
if (!mirror_remove_missing(cmd, lv, 1))
|
|
return_0;
|
|
goto restart;
|
|
}
|
|
|
|
if (arg_is_set(cmd, mirrorsonly_ARG) && !lv_is_mirrored(lv)) {
|
|
log_error("Non-mirror-image LV %s found: can't remove.", lv->name);
|
|
continue;
|
|
}
|
|
|
|
if (!lv_is_visible(lv))
|
|
continue;
|
|
|
|
log_warn("WARNING: Removing partial LV %s.", display_lvname(lv));
|
|
|
|
if (!lv_remove_with_dependencies(cmd, lv, DONT_PROMPT, 0))
|
|
return_0;
|
|
goto restart;
|
|
}
|
|
}
|
|
|
|
_consolidate_vg(cmd, vg);
|
|
|
|
return 1;
|
|
}
|
|
|
|
/* Or take pv_name instead? */
|
|
static int _vgreduce_single(struct cmd_context *cmd, struct volume_group *vg,
|
|
struct physical_volume *pv,
|
|
struct processing_handle *handle __attribute__((unused)))
|
|
{
|
|
int r;
|
|
|
|
if (!vg_check_status(vg, LVM_WRITE | RESIZEABLE_VG))
|
|
return ECMD_FAILED;
|
|
|
|
r = vgreduce_single(cmd, vg, pv, 1);
|
|
if (!r)
|
|
return ECMD_FAILED;
|
|
|
|
return ECMD_PROCESSED;
|
|
}
|
|
|
|
static int _vgreduce_repair_single(struct cmd_context *cmd, const char *vg_name,
|
|
struct volume_group *vg, struct processing_handle *handle)
|
|
{
|
|
struct vgreduce_params *vp = (struct vgreduce_params *) handle->custom_handle;
|
|
|
|
if (!vg_missing_pv_count(vg)) {
|
|
vp->already_consistent = 1;
|
|
return ECMD_PROCESSED;
|
|
}
|
|
|
|
if (vp->force) {
|
|
if (!_make_vg_consistent(cmd, vg))
|
|
return_ECMD_FAILED;
|
|
vp->fixed = 1;
|
|
} else
|
|
vp->fixed = _consolidate_vg(cmd, vg);
|
|
|
|
if (!vg_write(vg) || !vg_commit(vg)) {
|
|
log_error("Failed to write out a consistent VG for %s", vg_name);
|
|
return ECMD_FAILED;
|
|
}
|
|
|
|
return ECMD_PROCESSED;
|
|
}
|
|
|
|
int vgreduce(struct cmd_context *cmd, int argc, char **argv)
|
|
{
|
|
struct processing_handle *handle;
|
|
struct vgreduce_params vp = { 0 };
|
|
const char *vg_name;
|
|
int repairing = arg_is_set(cmd, removemissing_ARG);
|
|
int saved_ignore_suspended_devices = ignore_suspended_devices();
|
|
int ret;
|
|
|
|
if (!argc && !repairing) {
|
|
log_error("Please give volume group name and "
|
|
"physical volume paths.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
if (!argc) { /* repairing */
|
|
log_error("Please give volume group name.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
if (arg_is_set(cmd, mirrorsonly_ARG) && !repairing) {
|
|
log_error("--mirrorsonly requires --removemissing.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
if (argc == 1 && !arg_is_set(cmd, all_ARG) && !repairing) {
|
|
log_error("Please enter physical volume paths or option -a.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
if (argc > 1 && arg_is_set(cmd, all_ARG)) {
|
|
log_error("Option -a and physical volume paths mutually "
|
|
"exclusive.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
if (argc > 1 && repairing) {
|
|
log_error("Please only specify the volume group.");
|
|
return EINVALID_CMD_LINE;
|
|
}
|
|
|
|
vg_name = skip_dev_dir(cmd, argv[0], NULL);
|
|
argv++;
|
|
argc--;
|
|
|
|
if (!lock_global(cmd, "ex"))
|
|
return_ECMD_FAILED;
|
|
|
|
clear_hint_file(cmd);
|
|
|
|
if (!(handle = init_processing_handle(cmd, NULL))) {
|
|
log_error("Failed to initialize processing handle.");
|
|
return ECMD_FAILED;
|
|
}
|
|
handle->custom_handle = &vp;
|
|
|
|
if (!repairing) {
|
|
/* FIXME: Pass private struct through to all these functions */
|
|
/* and update in batch afterwards? */
|
|
|
|
ret = process_each_pv(cmd, argc, argv, vg_name, 0, READ_FOR_UPDATE,
|
|
handle, _vgreduce_single);
|
|
|
|
goto out;
|
|
}
|
|
|
|
/*
|
|
* VG repair (removemissing)
|
|
*/
|
|
|
|
vp.force = arg_count(cmd, force_ARG);
|
|
|
|
cmd->handles_missing_pvs = 1;
|
|
|
|
init_ignore_suspended_devices(1);
|
|
|
|
process_each_vg(cmd, 0, NULL, vg_name, NULL, READ_FOR_UPDATE,
|
|
0, handle, &_vgreduce_repair_single);
|
|
|
|
if (vp.already_consistent) {
|
|
log_print_unless_silent("Volume group \"%s\" is already consistent.", vg_name);
|
|
ret = ECMD_PROCESSED;
|
|
} else if (vp.fixed) {
|
|
log_print_unless_silent("Wrote out consistent volume group %s.", vg_name);
|
|
ret = ECMD_PROCESSED;
|
|
} else
|
|
ret = ECMD_FAILED;
|
|
out:
|
|
init_ignore_suspended_devices(saved_ignore_suspended_devices);
|
|
destroy_processing_handle(cmd, handle);
|
|
|
|
return ret;
|
|
}
|