mirror of
git://sourceware.org/git/lvm2.git
synced 2024-12-22 17:35:59 +03:00
b717e8fe1d
Renaming to get_object_path_by_uuid_lvm_id, to clarify that both the uuid and the lvm id are required.
283 lines
8.2 KiB
Python
283 lines
8.2 KiB
Python
# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
|
|
#
|
|
# This copyrighted material is made available to anyone wishing to use,
|
|
# modify, copy, or redistribute it subject to the terms and conditions
|
|
# of the GNU General Public License v.2.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
from .automatedproperties import AutomatedProperties
|
|
from . import utils
|
|
from . import cfg
|
|
import dbus
|
|
from .cfg import PV_INTERFACE
|
|
from . import cmdhandler
|
|
from .utils import vg_obj_path_generate, n, pv_obj_path_generate, \
|
|
lv_object_path_method
|
|
from .loader import common
|
|
from .request import RequestEntry
|
|
from .state import State
|
|
from .utils import round_size
|
|
|
|
|
|
# noinspection PyUnusedLocal
|
|
def pvs_state_retrieve(selection, cache_refresh=True):
|
|
rc = []
|
|
|
|
if cache_refresh:
|
|
cfg.db.refresh()
|
|
|
|
for p in cfg.db.fetch_pvs(selection):
|
|
rc.append(
|
|
PvState(
|
|
p["pv_name"], p["pv_uuid"], p["pv_name"],
|
|
p["pv_fmt"], n(p["pv_size"]), n(p["pv_free"]),
|
|
n(p["pv_used"]), n(p["dev_size"]), n(p["pv_mda_size"]),
|
|
n(p["pv_mda_free"]), int(p["pv_ba_start"]),
|
|
n(p["pv_ba_size"]), n(p["pe_start"]),
|
|
int(p["pv_pe_count"]), int(p["pv_pe_alloc_count"]),
|
|
p["pv_attr"], p["pv_tags"], p["vg_name"], p["vg_uuid"]))
|
|
return rc
|
|
|
|
|
|
def load_pvs(device=None, object_path=None, refresh=False, emit_signal=False,
|
|
cache_refresh=True):
|
|
return common(
|
|
pvs_state_retrieve, (Pv,), device, object_path, refresh,
|
|
emit_signal, cache_refresh)
|
|
|
|
|
|
# noinspection PyUnresolvedReferences
|
|
class PvState(State):
|
|
@property
|
|
def lvm_id(self):
|
|
return self.lvm_path
|
|
|
|
def _lv_object_list(self, vg_name):
|
|
|
|
# Note we are returning "a(oa(tts))"
|
|
|
|
rc = []
|
|
if vg_name:
|
|
for lv in sorted(cfg.db.pv_contained_lv(self.lvm_id)):
|
|
lv_uuid, lv_name, meta, segs = lv
|
|
full_name = "%s/%s" % (vg_name, lv_name)
|
|
|
|
path_create = lv_object_path_method(lv_name, meta)
|
|
lv_path = cfg.om.get_object_path_by_uuid_lvm_id(
|
|
lv_uuid, full_name, path_create)
|
|
|
|
rc.append((lv_path, segs))
|
|
return dbus.Array(rc, signature="(oa(tts))")
|
|
|
|
# noinspection PyUnusedLocal,PyPep8Naming
|
|
def __init__(self, lvm_path, Uuid, Name,
|
|
Fmt, SizeBytes, FreeBytes, UsedBytes, DevSizeBytes,
|
|
MdaSizeBytes, MdaFreeBytes, BaStart, BaSizeBytes,
|
|
PeStart, PeCount, PeAllocCount, attr, Tags, vg_name,
|
|
vg_uuid):
|
|
utils.init_class_from_arguments(self)
|
|
self.pe_segments = cfg.db.pv_pe_segments(Uuid)
|
|
|
|
self.lv = self._lv_object_list(vg_name)
|
|
|
|
if vg_name:
|
|
self.vg_path = cfg.om.get_object_path_by_uuid_lvm_id(
|
|
vg_uuid, vg_name, vg_obj_path_generate)
|
|
else:
|
|
self.vg_path = '/'
|
|
|
|
def identifiers(self):
|
|
return (self.Uuid, self.lvm_path)
|
|
|
|
def create_dbus_object(self, path):
|
|
if not path:
|
|
path = cfg.om.get_object_path_by_uuid_lvm_id(self.Uuid, self.Name,
|
|
pv_obj_path_generate)
|
|
return Pv(path, self)
|
|
|
|
# noinspection PyMethodMayBeStatic
|
|
def creation_signature(self):
|
|
return (Pv, pv_obj_path_generate)
|
|
|
|
|
|
# noinspection PyPep8Naming
|
|
@utils.dbus_property(PV_INTERFACE, 'Uuid', 's') # PV UUID/pv_uuid
|
|
@utils.dbus_property(PV_INTERFACE, 'Name', 's') # PV/pv_name
|
|
@utils.dbus_property(PV_INTERFACE, 'Fmt', 's') # Fmt/pv_fmt
|
|
@utils.dbus_property(PV_INTERFACE, 'SizeBytes', 't') # PSize/pv_size
|
|
@utils.dbus_property(PV_INTERFACE, 'FreeBytes', 't') # PFree/pv_free
|
|
@utils.dbus_property(PV_INTERFACE, 'UsedBytes', 't') # Used/pv_used
|
|
@utils.dbus_property(PV_INTERFACE, 'DevSizeBytes', 't') # DevSize/dev_size
|
|
@utils.dbus_property(PV_INTERFACE, 'MdaSizeBytes', 't') # PMdaSize/pv_mda_size
|
|
@utils.dbus_property(PV_INTERFACE, 'MdaFreeBytes', 't') # PMdaFree/pv_mda_free
|
|
@utils.dbus_property(PV_INTERFACE, 'BaStart', 't') # BA start/pv_ba_start
|
|
@utils.dbus_property(PV_INTERFACE, 'BaSizeBytes', 't') # BA size/pv_ba_size
|
|
@utils.dbus_property(PV_INTERFACE, 'PeStart', 't') # 1st PE/pe_start
|
|
@utils.dbus_property(PV_INTERFACE, 'PeCount', 't') # PE/pv_pe_count
|
|
@utils.dbus_property(PV_INTERFACE, 'PeAllocCount', 't') # PE Allocation count
|
|
class Pv(AutomatedProperties):
|
|
# For properties that we need custom handlers we need these, otherwise
|
|
# we won't get our introspection data
|
|
_Tags_meta = ("as", PV_INTERFACE)
|
|
_PeSegments_meta = ("a(tt)", PV_INTERFACE)
|
|
_Exportable_meta = ("b", PV_INTERFACE)
|
|
_Allocatable_meta = ("b", PV_INTERFACE)
|
|
_Missing_meta = ("b", PV_INTERFACE)
|
|
_Lv_meta = ("a(oa(tts))", PV_INTERFACE)
|
|
_Vg_meta = ("o", PV_INTERFACE)
|
|
|
|
# noinspection PyUnusedLocal,PyPep8Naming
|
|
def __init__(self, object_path, state_obj):
|
|
super(Pv, self).__init__(object_path, pvs_state_retrieve)
|
|
self.set_interface(PV_INTERFACE)
|
|
self.state = state_obj
|
|
|
|
@staticmethod
|
|
def _remove(pv_uuid, pv_name, remove_options):
|
|
# Remove the PV, if successful then remove from the model
|
|
# Make sure we have a dbus object representing it
|
|
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
|
|
|
|
if dbo:
|
|
rc, out, err = cmdhandler.pv_remove(pv_name, remove_options)
|
|
if rc == 0:
|
|
cfg.om.remove_object(dbo, True)
|
|
else:
|
|
# Need to work on error handling, need consistent
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE,
|
|
'Exit code %s, stderr = %s' % (str(rc), err))
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE,
|
|
'PV with uuid %s and name %s not present!' %
|
|
(pv_uuid, pv_name))
|
|
return '/'
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=PV_INTERFACE,
|
|
in_signature='ia{sv}',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def Remove(self, tmo, remove_options, cb, cbe):
|
|
r = RequestEntry(
|
|
tmo, Pv._remove,
|
|
(self.Uuid, self.lvm_id, remove_options),
|
|
cb, cbe, return_tuple=False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _resize(pv_uuid, pv_name, new_size_bytes, resize_options):
|
|
# Make sure we have a dbus object representing it
|
|
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
|
|
|
|
if dbo:
|
|
rc, out, err = cmdhandler.pv_resize(pv_name, new_size_bytes,
|
|
resize_options)
|
|
if rc == 0:
|
|
dbo.refresh()
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE,
|
|
'Exit code %s, stderr = %s' % (str(rc), err))
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE,
|
|
'PV with uuid %s and name %s not present!' %
|
|
(pv_uuid, pv_name))
|
|
return '/'
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=PV_INTERFACE,
|
|
in_signature='tia{sv}',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def ReSize(self, new_size_bytes, tmo, resize_options, cb, cbe):
|
|
r = RequestEntry(
|
|
tmo, Pv._resize,
|
|
(self.Uuid, self.lvm_id, round_size(new_size_bytes),
|
|
resize_options), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _allocation_enabled(pv_uuid, pv_name, yes_no, allocation_options):
|
|
# Make sure we have a dbus object representing it
|
|
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
|
|
|
|
if dbo:
|
|
rc, out, err = cmdhandler.pv_allocatable(
|
|
pv_name, yes_no, allocation_options)
|
|
if rc == 0:
|
|
cfg.load()
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE, 'Exit code %s, stderr = %s' % (str(rc), err))
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
PV_INTERFACE,
|
|
'PV with uuid %s and name %s not present!' %
|
|
(pv_uuid, pv_name))
|
|
return '/'
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=PV_INTERFACE,
|
|
in_signature='bia{sv}',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def AllocationEnabled(self, yes, tmo, allocation_options, cb, cbe):
|
|
r = RequestEntry(
|
|
tmo, Pv._allocation_enabled,
|
|
(self.Uuid, self.lvm_id,
|
|
yes, allocation_options),
|
|
cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@property
|
|
def Tags(self):
|
|
return utils.parse_tags(self.state.Tags)
|
|
|
|
@property
|
|
def PeSegments(self):
|
|
if len(self.state.pe_segments):
|
|
return self.state.pe_segments
|
|
return dbus.Array([], '(tt)')
|
|
|
|
@property
|
|
def Exportable(self):
|
|
if self.state.attr[1] == 'x':
|
|
return True
|
|
return False
|
|
|
|
@property
|
|
def Allocatable(self):
|
|
if self.state.attr[0] == 'a':
|
|
return True
|
|
return False
|
|
|
|
@property
|
|
def Missing(self):
|
|
if self.state.attr[2] == 'm':
|
|
return True
|
|
return False
|
|
|
|
def object_path(self):
|
|
return self._object_path
|
|
|
|
@property
|
|
def lvm_id(self):
|
|
return self.state.lvm_id
|
|
|
|
@property
|
|
def identifiers(self):
|
|
return self.state.identifiers()
|
|
|
|
@property
|
|
def Lv(self):
|
|
return self.state.lv
|
|
|
|
@property
|
|
def Vg(self):
|
|
return self.state.vg_path
|