1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-21 13:34:40 +03:00
lvm2/daemons/lvmdbusd/manager.py
Marian Csontos 5cf51fb2f7 dbus: log_debug needs qualifier
Adding qualifier makes the only unqualified log_debug occurence
consistent with other uses in the same file.

Other possible ways to fix this:

- using `from .utils import log_debug`
- moving the line below `from . import utils` line
2017-04-27 18:16:17 +02:00

268 lines
7.6 KiB
Python

# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
#
# This copyrighted material is made available to anyone wishing to use,
# modify, copy, or redistribute it subject to the terms and conditions
# of the GNU General Public License v.2.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
from .automatedproperties import AutomatedProperties
from . import utils
from .cfg import MANAGER_INTERFACE
import dbus
from . import cfg
from . import cmdhandler
from .request import RequestEntry
from . import udevwatch
# noinspection PyPep8Naming
class Manager(AutomatedProperties):
_Version_meta = ("s", MANAGER_INTERFACE)
def __init__(self, object_path):
super(Manager, self).__init__(object_path)
self.set_interface(MANAGER_INTERFACE)
@property
def Version(self):
return dbus.String('1.0.0')
@staticmethod
def handle_execute(rc, out, err):
if rc == 0:
cfg.load()
else:
# Need to work on error handling, need consistent
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE,
'Exit code %s, stderr = %s' % (str(rc), err))
@staticmethod
def _pv_create(device, create_options):
# Check to see if we are already trying to create a PV for an existing
# PV
pv = cfg.om.get_object_path_by_uuid_lvm_id(device, device)
if pv:
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE, "PV %s Already exists!" % device)
rc, out, err = cmdhandler.pv_create(create_options, [device])
Manager.handle_execute(rc, out, err)
return cfg.om.get_object_path_by_lvm_id(device)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='sia{sv}',
out_signature='(oo)',
async_callbacks=('cb', 'cbe'))
def PvCreate(self, device, tmo, create_options, cb, cbe):
utils.validate_device_path(MANAGER_INTERFACE, device)
r = RequestEntry(
tmo, Manager._pv_create,
(device, create_options), cb, cbe)
cfg.worker_q.put(r)
@staticmethod
def _create_vg(name, pv_object_paths, create_options):
pv_devices = []
for p in pv_object_paths:
pv = cfg.om.get_object_by_path(p)
if pv:
pv_devices.append(pv.Name)
else:
raise dbus.exceptions.DBusException(
MANAGER_INTERFACE, 'object path = %s not found' % p)
rc, out, err = cmdhandler.vg_create(create_options, pv_devices, name)
Manager.handle_execute(rc, out, err)
return cfg.om.get_object_path_by_lvm_id(name)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='saoia{sv}',
out_signature='(oo)',
async_callbacks=('cb', 'cbe'))
def VgCreate(self, name, pv_object_paths, tmo, create_options, cb, cbe):
utils.validate_vg_name(MANAGER_INTERFACE, name)
r = RequestEntry(
tmo, Manager._create_vg,
(name, pv_object_paths, create_options,),
cb, cbe)
cfg.worker_q.put(r)
@staticmethod
def _refresh():
utils.log_debug('Manager.Refresh - entry')
# This is a diagnostic and should not be run in normal operation, so
# lets remove the log entries for refresh as it's implied.
# Run an internal diagnostic on the object manager look up tables
lc = cfg.om.validate_lookups()
rc = cfg.load(log=False)
if rc != 0:
utils.log_debug('Manager.Refresh - exit %d' % (rc),
'bg_black', 'fg_light_red')
else:
utils.log_debug('Manager.Refresh - exit %d' % (rc))
return rc + lc
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
out_signature='t',
async_callbacks=('cb', 'cbe'))
def Refresh(self, cb, cbe):
"""
Take all the objects we know about and go out and grab the latest
more of a test method at the moment to make sure we are handling object
paths correctly.
:param cb Callback for result
:param cbe Callback for errors
Returns the number of changes, object add/remove/properties changed
"""
r = RequestEntry(-1, Manager._refresh, (), cb, cbe, False)
cfg.worker_q.put(r)
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE)
def FlightRecorderDump(self):
"""
Dump the flight recorder to syslog
"""
cfg.blackbox.dump()
@staticmethod
def _lookup_by_lvm_id(key):
p = cfg.om.get_object_path_by_uuid_lvm_id(key, key)
if not p:
p = '/'
utils.log_debug('LookUpByLvmId: key = %s, result = %s' % (key, p))
return p
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='s',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def LookUpByLvmId(self, key, cb, cbe):
"""
Given a lvm id in one of the forms:
/dev/sda
some_vg
some_vg/some_lv
Oe1rPX-Pf0W-15E5-n41N-ZmtF-jXS0-Osg8fn
return the object path in O(1) time.
:param key: The lookup value
:return: Return the object path. If object not found you will get '/'
"""
r = RequestEntry(-1, Manager._lookup_by_lvm_id, (key,), cb, cbe, False)
cfg.worker_q.put(r)
@staticmethod
def _use_lvm_shell(yes_no):
return dbus.Boolean(cmdhandler.set_execution(yes_no))
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='b', out_signature='b',
async_callbacks=('cb', 'cbe'))
def UseLvmShell(self, yes_no, cb, cbe):
"""
Allow the client to enable/disable lvm shell, used for testing
:param yes_no:
:param cb: dbus python call back parameter, not client visible
:param cbe: dbus python error call back parameter, not client visible
:return: Boolean
"""
r = RequestEntry(-1, Manager._use_lvm_shell, (yes_no,), cb, cbe, False)
cfg.worker_q.put(r)
@staticmethod
def _external_event(command):
utils.log_debug("Processing _external_event= %s" % command,
'bg_black', 'fg_orange')
cfg.load()
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='s', out_signature='i')
def ExternalEvent(self, command):
utils.log_debug("ExternalEvent %s" % command)
# If a user didn't explicitly specify udev, we will turn it off now.
if not cfg.args.use_udev:
if udevwatch.remove():
utils.log_debug("ExternalEvent received, disabling "
"udev monitoring")
# We are dependent on external events now to stay current!
cfg.got_external_event = True
r = RequestEntry(
-1, Manager._external_event, (command,), None, None, False)
cfg.worker_q.put(r)
return dbus.Int32(0)
@staticmethod
def _pv_scan(activate, cache, device_path, major_minor, scan_options):
rc, out, err = cmdhandler.pv_scan(
activate, cache, device_path,
major_minor, scan_options)
Manager.handle_execute(rc, out, err)
return '/'
@dbus.service.method(
dbus_interface=MANAGER_INTERFACE,
in_signature='bbasa(ii)ia{sv}',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def PvScan(self, activate, cache, device_paths, major_minors,
tmo, scan_options, cb, cbe):
"""
Scan all supported LVM block devices in the system for physical volumes
NOTE: major_minors & device_paths only usable when cache == True
:param activate: If True, activate any newly found LVs
:param cache: If True, update lvmetad
:param device_paths: Array of device paths or empty
:param major_minors: Array of structures (major,minor)
:param tmo: Timeout for operation
:param scan_options: Additional options to pvscan
:param cb: Not visible in API (used for async. callback)
:param cbe: Not visible in API (used for async. error callback)
:return: '/' if operation done, else job path
"""
for d in device_paths:
utils.validate_device_path(MANAGER_INTERFACE, d)
r = RequestEntry(
tmo, Manager._pv_scan,
(activate, cache, device_paths, major_minors,
scan_options), cb, cbe, False)
cfg.worker_q.put(r)
@property
def lvm_id(self):
"""
Intended to be overridden by classes that inherit
"""
return str(id(self))
@property
def Uuid(self):
"""
Intended to be overridden by classes that inherit
"""
import uuid
return uuid.uuid1()