# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
|
|
#
|
|
# This copyrighted material is made available to anyone wishing to use,
|
|
# modify, copy, or redistribute it subject to the terms and conditions
|
|
# of the GNU General Public License v.2.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
from .automatedproperties import AutomatedProperties
|
|
|
|
from . import utils
|
|
from .cfg import MANAGER_INTERFACE
|
|
import dbus
|
|
from . import cfg
|
|
from . import cmdhandler
|
|
from .request import RequestEntry
|
|
from . import udevwatch
|
|
|
|
|
|
# noinspection PyPep8Naming
|
|
class Manager(AutomatedProperties):
|
|
_Version_meta = ("s", MANAGER_INTERFACE)
|
|
|
|
def __init__(self, object_path):
|
|
super(Manager, self).__init__(object_path)
|
|
self.set_interface(MANAGER_INTERFACE)
|
|
|
|
@property
|
|
def Version(self):
|
|
return dbus.String('1.0.0')
|
|
|
|
@staticmethod
|
|
def handle_execute(rc, out, err):
|
|
if rc == 0:
|
|
cfg.load()
|
|
else:
|
|
# Need to work on error handling, need consistent
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE,
|
|
'Exit code %s, stderr = %s' % (str(rc), err))
|
|
|
|
@staticmethod
|
|
def _pv_create(device, create_options):
|
|
|
|
# Check to see if we are already trying to create a PV for an existing
|
|
# PV
|
|
pv = cfg.om.get_object_path_by_uuid_lvm_id(device, device)
|
|
if pv:
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE, "PV %s Already exists!" % device)
|
|
|
|
rc, out, err = cmdhandler.pv_create(create_options, [device])
|
|
Manager.handle_execute(rc, out, err)
|
|
return cfg.om.get_object_path_by_lvm_id(device)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='sia{sv}',
|
|
out_signature='(oo)',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def PvCreate(self, device, tmo, create_options, cb, cbe):
|
|
utils.validate_device_path(MANAGER_INTERFACE, device)
|
|
r = RequestEntry(
|
|
tmo, Manager._pv_create,
|
|
(device, create_options), cb, cbe)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _create_vg(name, pv_object_paths, create_options):
|
|
pv_devices = []
|
|
|
|
for p in pv_object_paths:
|
|
pv = cfg.om.get_object_by_path(p)
|
|
if pv:
|
|
pv_devices.append(pv.Name)
|
|
else:
|
|
raise dbus.exceptions.DBusException(
|
|
MANAGER_INTERFACE, 'object path = %s not found' % p)
|
|
|
|
rc, out, err = cmdhandler.vg_create(create_options, pv_devices, name)
|
|
Manager.handle_execute(rc, out, err)
|
|
return cfg.om.get_object_path_by_lvm_id(name)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='saoia{sv}',
|
|
out_signature='(oo)',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def VgCreate(self, name, pv_object_paths, tmo, create_options, cb, cbe):
|
|
utils.validate_vg_name(MANAGER_INTERFACE, name)
|
|
r = RequestEntry(
|
|
tmo, Manager._create_vg,
|
|
(name, pv_object_paths, create_options,),
|
|
cb, cbe)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _refresh():
|
|
utils.log_debug('Manager.Refresh - entry')
|
|
|
|
# This is a diagnostic and should not be run in normal operation, so
|
|
# lets remove the log entries for refresh as it's implied.
|
|
|
|
# Run an internal diagnostic on the object manager look up tables
|
|
lc = cfg.om.validate_lookups()
|
|
|
|
rc = cfg.load(log=False)
|
|
|
|
if rc != 0:
|
|
utils.log_debug('Manager.Refresh - exit %d' % (rc),
|
|
'bg_black', 'fg_light_red')
|
|
else:
|
|
utils.log_debug('Manager.Refresh - exit %d' % (rc))
|
|
return rc + lc
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
out_signature='t',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def Refresh(self, cb, cbe):
|
|
"""
|
|
Take all the objects we know about and go out and grab the latest
|
|
more of a test method at the moment to make sure we are handling object
|
|
paths correctly.
|
|
|
|
:param cb Callback for result
|
|
:param cbe Callback for errors
|
|
|
|
Returns the number of changes, object add/remove/properties changed
|
|
"""
|
|
r = RequestEntry(-1, Manager._refresh, (), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE)
|
|
def FlightRecorderDump(self):
|
|
"""
|
|
Dump the flight recorder to syslog
|
|
"""
|
|
cfg.blackbox.dump()
|
|
|
|
@staticmethod
|
|
def _lookup_by_lvm_id(key):
|
|
p = cfg.om.get_object_path_by_uuid_lvm_id(key, key)
|
|
if not p:
|
|
p = '/'
|
|
utils.log_debug('LookUpByLvmId: key = %s, result = %s' % (key, p))
|
|
return p
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='s',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def LookUpByLvmId(self, key, cb, cbe):
|
|
"""
|
|
Given a lvm id in one of the forms:
|
|
|
|
/dev/sda
|
|
some_vg
|
|
some_vg/some_lv
|
|
Oe1rPX-Pf0W-15E5-n41N-ZmtF-jXS0-Osg8fn
|
|
|
|
return the object path in O(1) time.
|
|
|
|
:param key: The lookup value
|
|
:return: Return the object path. If object not found you will get '/'
|
|
"""
|
|
r = RequestEntry(-1, Manager._lookup_by_lvm_id, (key,), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _use_lvm_shell(yes_no):
|
|
return dbus.Boolean(cmdhandler.set_execution(yes_no))
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='b', out_signature='b',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def UseLvmShell(self, yes_no, cb, cbe):
|
|
"""
|
|
Allow the client to enable/disable lvm shell, used for testing
|
|
:param yes_no:
|
|
:param cb: dbus python call back parameter, not client visible
|
|
:param cbe: dbus python error call back parameter, not client visible
|
|
:return: Boolean
|
|
"""
|
|
r = RequestEntry(-1, Manager._use_lvm_shell, (yes_no,), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@staticmethod
|
|
def _external_event(command):
|
|
utils.log_debug("Processing _external_event= %s" % command,
|
|
'bg_black', 'fg_orange')
|
|
cfg.load()
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='s', out_signature='i')
|
|
def ExternalEvent(self, command):
|
|
utils.log_debug("ExternalEvent %s" % command)
|
|
# If a user didn't explicitly specify udev, we will turn it off now.
|
|
if not cfg.args.use_udev:
|
|
if udevwatch.remove():
|
|
utils.log_debug("ExternalEvent received, disabling "
|
|
"udev monitoring")
|
|
# We are dependent on external events now to stay current!
|
|
cfg.got_external_event = True
|
|
|
|
r = RequestEntry(
|
|
-1, Manager._external_event, (command,), None, None, False)
|
|
cfg.worker_q.put(r)
|
|
return dbus.Int32(0)
|
|
|
|
@staticmethod
|
|
def _pv_scan(activate, cache, device_path, major_minor, scan_options):
|
|
|
|
rc, out, err = cmdhandler.pv_scan(
|
|
activate, cache, device_path,
|
|
major_minor, scan_options)
|
|
|
|
Manager.handle_execute(rc, out, err)
|
|
return '/'
|
|
|
|
@dbus.service.method(
|
|
dbus_interface=MANAGER_INTERFACE,
|
|
in_signature='bbasa(ii)ia{sv}',
|
|
out_signature='o',
|
|
async_callbacks=('cb', 'cbe'))
|
|
def PvScan(self, activate, cache, device_paths, major_minors,
|
|
tmo, scan_options, cb, cbe):
|
|
"""
|
|
Scan all supported LVM block devices in the system for physical volumes
|
|
NOTE: major_minors & device_paths only usable when cache == True
|
|
:param activate: If True, activate any newly found LVs
|
|
:param cache: If True, update lvmetad
|
|
:param device_paths: Array of device paths or empty
|
|
:param major_minors: Array of structures (major,minor)
|
|
:param tmo: Timeout for operation
|
|
:param scan_options: Additional options to pvscan
|
|
:param cb: Not visible in API (used for async. callback)
|
|
:param cbe: Not visible in API (used for async. error callback)
|
|
:return: '/' if operation done, else job path
|
|
"""
|
|
for d in device_paths:
|
|
utils.validate_device_path(MANAGER_INTERFACE, d)
|
|
|
|
r = RequestEntry(
|
|
tmo, Manager._pv_scan,
|
|
(activate, cache, device_paths, major_minors,
|
|
scan_options), cb, cbe, False)
|
|
cfg.worker_q.put(r)
|
|
|
|
@property
|
|
def lvm_id(self):
|
|
"""
|
|
Intended to be overridden by classes that inherit
|
|
"""
|
|
return str(id(self))
|
|
|
|
@property
|
|
def Uuid(self):
|
|
"""
|
|
Intended to be overridden by classes that inherit
|
|
"""
|
|
import uuid
|
|
return uuid.uuid1()
|