mirror of
https://github.com/systemd/systemd-stable.git
synced 2024-12-22 13:33:56 +03:00
man: document the RestartKillSignal= setting
This commit is contained in:
parent
a232ebcc2c
commit
b557f1c147
@ -85,32 +85,36 @@
|
||||
unless it is empty.</para>
|
||||
|
||||
<para>Processes will first be terminated via <constant>SIGTERM</constant> (unless the signal to send
|
||||
is changed via <varname>KillSignal=</varname>). Optionally, this is immediately followed by a
|
||||
<constant>SIGHUP</constant> (if enabled with <varname>SendSIGHUP=</varname>). If processes still
|
||||
remain after the main process of a unit has exited or the delay configured via the
|
||||
<varname>TimeoutStopSec=</varname> has passed, the termination request is repeated with the
|
||||
<constant>SIGKILL</constant> signal or the signal specified via <varname>FinalKillSignal=</varname>
|
||||
(unless this is disabled via the <varname>SendSIGKILL=</varname> option). See
|
||||
<citerefentry><refentrytitle>kill</refentrytitle><manvolnum>2</manvolnum></citerefentry> for more
|
||||
information.</para>
|
||||
is changed via <varname>KillSignal=</varname> or <varname>RestartKillSignal=</varname>). Optionally,
|
||||
this is immediately followed by a <constant>SIGHUP</constant> (if enabled with
|
||||
<varname>SendSIGHUP=</varname>). If processes still remain after the main process of a unit has
|
||||
exited or the delay configured via the <varname>TimeoutStopSec=</varname> has passed, the termination
|
||||
request is repeated with the <constant>SIGKILL</constant> signal or the signal specified via
|
||||
<varname>FinalKillSignal=</varname> (unless this is disabled via the <varname>SendSIGKILL=</varname>
|
||||
option). See <citerefentry><refentrytitle>kill</refentrytitle><manvolnum>2</manvolnum></citerefentry>
|
||||
for more information.</para>
|
||||
|
||||
<para>Defaults to <option>control-group</option>.</para></listitem>
|
||||
</varlistentry>
|
||||
|
||||
<varlistentry>
|
||||
<term><varname>KillSignal=</varname></term>
|
||||
<listitem><para>Specifies which signal to use when killing a
|
||||
service. This controls the signal that is sent as first step
|
||||
of shutting down a unit (see above), and is usually followed
|
||||
by <constant>SIGKILL</constant> (see above and below). For a
|
||||
list of valid signals, see
|
||||
<listitem><para>Specifies which signal to use when stopping a service. This controls the signal that
|
||||
is sent as first step of shutting down a unit (see above), and is usually followed by
|
||||
<constant>SIGKILL</constant> (see above and below). For a list of valid signals, see
|
||||
<citerefentry project='man-pages'><refentrytitle>signal</refentrytitle><manvolnum>7</manvolnum></citerefentry>.
|
||||
Defaults to <constant>SIGTERM</constant>. </para>
|
||||
Defaults to <constant>SIGTERM</constant>.</para>
|
||||
|
||||
<para>Note that, right after sending the signal specified in
|
||||
this setting, systemd will always send
|
||||
<constant>SIGCONT</constant>, to ensure that even suspended
|
||||
tasks can be terminated cleanly.</para>
|
||||
<para>Note that, right after sending the signal specified in this setting, systemd will always send
|
||||
<constant>SIGCONT</constant>, to ensure that even suspended tasks can be terminated cleanly.</para>
|
||||
</listitem>
|
||||
</varlistentry>
|
||||
|
||||
<varlistentry>
|
||||
<term><varname>RestartKillSignal=</varname></term>
|
||||
<listitem><para>Specifies which signal to use when restarting a service. The same as
|
||||
<varname>KillSignal=</varname> described above, with the exception that this setting is used in a
|
||||
restart job. Not set by default, and the value of <varname>KillSignal=</varname> is used.</para>
|
||||
</listitem>
|
||||
</varlistentry>
|
||||
|
||||
|
@ -477,26 +477,24 @@
|
||||
|
||||
<varlistentry>
|
||||
<term><varname>ExecStop=</varname></term>
|
||||
<listitem><para>Commands to execute to stop the service
|
||||
started via <varname>ExecStart=</varname>. This argument takes
|
||||
multiple command lines, following the same scheme as described
|
||||
for <varname>ExecStart=</varname> above. Use of this setting
|
||||
is optional. After the commands configured in this option are
|
||||
run, it is implied that the service is stopped, and any processes
|
||||
remaining for it are terminated
|
||||
according to the <varname>KillMode=</varname> setting (see
|
||||
<listitem><para>Commands to execute to stop the service started via
|
||||
<varname>ExecStart=</varname>. This argument takes multiple command lines, following the same scheme
|
||||
as described for <varname>ExecStart=</varname> above. Use of this setting is optional. After the
|
||||
commands configured in this option are run, it is implied that the service is stopped, and any
|
||||
processes remaining for it are terminated according to the <varname>KillMode=</varname> setting (see
|
||||
<citerefentry><refentrytitle>systemd.kill</refentrytitle><manvolnum>5</manvolnum></citerefentry>).
|
||||
If this option is not specified, the process is terminated by
|
||||
sending the signal specified in <varname>KillSignal=</varname>
|
||||
when service stop is requested. Specifier and environment
|
||||
variable substitution is supported (including
|
||||
If this option is not specified, the process is terminated by sending the signal specified in
|
||||
<varname>KillSignal=</varname> or <varname>RestartKillSignal=</varname> when service stop is
|
||||
requested. Specifier and environment variable substitution is supported (including
|
||||
<varname>$MAINPID</varname>, see above).</para>
|
||||
|
||||
<para>Note that it is usually not sufficient to specify a command for this setting that only asks the service
|
||||
to terminate (for example, by queuing some form of termination signal for it), but does not wait for it to do
|
||||
so. Since the remaining processes of the services are killed according to <varname>KillMode=</varname> and
|
||||
<varname>KillSignal=</varname> as described above immediately after the command exited, this may not result in
|
||||
a clean stop. The specified command should hence be a synchronous operation, not an asynchronous one.</para>
|
||||
<para>Note that it is usually not sufficient to specify a command for this setting that only asks the
|
||||
service to terminate (for example, by sending some form of termination signal to it), but does not
|
||||
wait for it to do so. Since the remaining processes of the services are killed according to
|
||||
<varname>KillMode=</varname> and <varname>KillSignal=</varname> or
|
||||
<varname>RestartKillSignal=</varname> as described above immediately after the command exited, this
|
||||
may not result in a clean stop. The specified command should hence be a synchronous operation, not an
|
||||
asynchronous one.</para>
|
||||
|
||||
<para>Note that the commands specified in <varname>ExecStop=</varname> are only executed when the service
|
||||
started successfully first. They are not invoked if the service was never started at all, or in case its
|
||||
|
Loading…
Reference in New Issue
Block a user