1
1
mirror of https://github.com/systemd/systemd-stable.git synced 2024-11-01 09:21:11 +03:00
systemd-stable/extras/path_id
Greg Kroah-Hartman f3aef1a78e add parisc support to path_id
As reported at http://bugs.gentoo.org/show_bug.cgi?id=113379 path_id
doesn't work too well for parisc boxes.  This patch from Jeroen Roovers
<jer@gentoo.org> fixes that.

Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
2005-12-07 14:00:05 -08:00

397 lines
9.0 KiB
Bash
Executable File

#!/bin/sh
# provide the shortest possible unique hardware path to a block device
# for the udev persistent disk device naming scheme
#
# Copyright (C) 2005 SUSE Linux Products GmbH
# Author:
# Hannes Reinecke <hare@suse.de>
#
# This program is free software; you can redistribute it and/or modify it
# under the terms of the GNU General Public License as published by the
# Free Software Foundation version 2 of the License.
#
# to be called from a udev rule to return the name for a symlink
# DEVPATH=/block/sda/sda3 path_id
# path_id <devpath>
# example for all block devices on a system:
# for i in `find /sys/block -name dev` ;do DEVPATH="`echo $i | sed -e 's@^/sys\|/dev@@g'`" path_id ; done
# examples:
# SCSI cdrom
# /block/sr0 -> /devices/pci0002:30/0002:30:0c.0/host0/0:0:1:0
# result: pci-0002:30:0c.0-scsi-0:0:1:0
# SCSI disk
# /block/sda -> /devices/pci0002:30/0002:30:0c.0/host0/0:0:4:0
# result: pci-0002:30:0c.0-scsi-0:0:4:0
# SATA disk, 4 channels per controller
# /block/sda -> /devices/pci0001:00/0001:00:07.0/0001:05:0c.0/host0/0:0:0:0
# result: pci-0001:05:0c.0-scsi-0:0:0:0
# IDE disk
# /block/hda -> /devices/pci0002:02/0002:02:0d.0/ide0/0.0
# result: pci-0002:02:0d.0-ide-0.0
# IDE cdrom on a Mac ASIC:
# /block/hdc -> /devices/pci0001:01/0001:01:17.0/0.80000000:mac-io/0.00020000:ata-3/ide1/1.0
# result: mac-io_ata-3_master
# IDE cdrom on a Mac ASIC, with ide-scsi:
# /block/sr0 -> /devices/pci0001:01/0001:01:17.0/0.80000000:mac-io/0.0001f000:ata-4/ide0/0.1/host2/2:0:0:0
# result: mac-io_ata-4_slave
# USB CDrom drive without 'serial' number:
# reusing 'product' and 'manufacturer' string, if available
# /block/sr0 -> /devices/pci0001:00/0001:00:04.0/0001:02:0b.0/usb4/4-2/4-2:1.0/host4/4:0:0:0
# result: usb-storage-odd-Freecom-USIDERev930:0:0:0
# devices may have several interfaces on one PCI device, like IDE:
# pci-0001:00:04.0_ide1-master
# pci-0001:00:04.0_ide2-master
# pci-0001:00:04.0_ide2-slave
# they are marked as ports, it is expected that the driver shows
# ide1 even if there is nothing connected to either master or slave
# interface
#
# match order is important.
# first IDE to find ide-scsi devices.
# then SCSI
# first usb-storage
# then firewire sbp2
# then the rest
SYSFS=/sys
RESULT=1
CDROM=
TYPE=
OPWD="`pwd`"
# Check for 'pwd -P'
if $(pwd -P > /dev/null 2>&1); then
pwd_cmd="pwd -P"
else
pwd_cmd="pwd"
fi
full_sysfs_class_path=
full_sysfs_device_path=
if [ -z "$DEVPATH" -a -z "$1" ] ; then
exit 1
fi
if [ -z "$DEVPATH" ] ; then
case "$1" in
$SYSFS/*)
DEVPATH="${1#$SYSFS}"
;;
*)
DEVPATH=$1
;;
esac
fi
if [ ! -d $SYSFS$DEVPATH ] ; then
exit 1
fi
if [ ! -f $SYSFS$DEVPATH/dev ] ; then
exit 1
fi
case "$DEVPATH" in
/block/*)
TYPE=block
;;
/class/*)
TYPE="${DEVPATH#/class/}"
TYPE="${TYPE%%/*}"
;;
*)
exit 1
;;
esac
#
##
#
get_port () {
local type offset port
type=$1
offset=$2
for i in $type[0-9]* ; do
: i $i
port="${i#$type}"
if [ "$port" -lt "$offset" ] ; then offset=$port ; fi
done
if [ "$port" != "0" ] ; then
echo $(($2 - $offset))
fi
}
handle_block_ide () {
: handle_block_ide $*
local DEV=$1
local port idedev idecontroller
# IDE
: DEV $DEV
d=$DEV
case "$DEV" in
# remove ide-scsi part, leave only channel info
*/ide[0-9]*/host[0-9]*)
while [ ! -z "$d" ] ; do
case "$d" in
*/host[0-9]*)
d="${d%/*}"
continue
;;
*)
break
;;
esac
done
;;
esac
idedev=$d
while [ ! -z "$d" ] ; do
case "$d" in
*/ide[0-9]*)
port="${d##*/}"
d="${d%/*}"
continue
;;
*)
break
;;
esac
done
idecontroller=$d
# port info if the controller has more than one interface
port="${port#ide}"
: port $port d $d
: idedev $idedev kernel_port $port
case "${idedev##*.}" in
0)
channel=0
;;
1)
channel=1
;;
*)
echo "Error: $idedev is neither master or slave" >&2
esac
case "$d" in
*:mac-io/*)
: mac-io: $d
d="`echo $d | sed -e 's@^.*:mac-io[^:]\+:\([^/]\+\).*@mac-io_\1@'`"
;;
/sys/devices)
# PCMCIA devices
ifname=${full_sysfs_class_path##*/}
set -- `sed -n "/$ifname/p" /var/lib/pcmcia/stab`
d="pcmcia-$1"
;;
*)
d="pci-${d##*/}"
# d="`echo $d | sed -e 's@^.*/\([^/]\{1,\}\)/.@pci-\1@'`"
;;
esac
cd $idecontroller
port="`get_port ide $port`"
cd "$OPWD"
: hardware_port $port
if [ -z "$port" ] ; then
d="${d}-ide-0:$channel"
else
d="${d}-ide-${port}:$channel"
fi
RESULT=0
}
handle_block_scsi () {
: handle_block_scsi $*
local DEV=$1
local cil controller_port controller_dev
# SCSI device
cil="${DEV##*/}"
cil="${cil#*:}"
controller_dev=$DEV
while [ ! -z "$controller_dev" ] ; do
case "$controller_dev" in
*/host[0-9]*)
controller_port=$controller_dev
controller_dev="${controller_dev%/*}"
;;
*) break ;;
esac
done
: controller_dev $controller_dev
: controller_port $controller_port
# a host controller may have more than one interface/port
controller_port="${controller_port##*/}"
controller_port="${controller_port##host}"
#
case "$controller_dev" in
# grand central, old powermacs
*:gc/*)
adapter="`echo $controller_dev | sed -e 's@/[^/]\{1,\}$@@;s@^.*/@@;s@^.*:@@'`"
bus="gc"
;;
# PARISC devices
*parisc*)
adapter="${controler_dev##*/}"
bus=parisc;
;;
*)
adapter="${controller_dev##*/}"
bus="pci"
;;
esac
cd "$controller_dev"
controller_port="`get_port host $controller_port`"
cd "$OPWD"
d="$bus-$adapter"
if [ -z "$controller_port" ] ; then
controller_port=0
fi
d="${d}-scsi-${controller_port}:${cil}"
RESULT=0
}
handle_block_usb_storage () {
: handle_block_usb_storage $*
local DEV=$1
cil="${DEV##*/}"
cil="${cil#*:}"
controller_dev=$DEV
while [ ! -z "$controller_dev" ] ; do
case "$controller_dev" in
*/host[0-9]*)
controller_dev="${controller_dev%/*}"
;;
*) break ;;
esac
done
: controller_dev $controller_dev
#
# usb-storage devs have a serial number, hopefully unique
serial=
if [ -f $controller_dev/../serial ] ; then
serial="`sed -e 's@^[ -]\{1,\}\|[ -]\{1,\}$@@g;s@[^abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ-_0123456789]@@g' < $controller_dev/../serial`"
: serial XXX_${serial}_XXX
d="usb-$serial"
serial="`echo $serial | sed -e 's@[ 0]\{1,\}@@g'`"
fi
if [ -z "$serial" ] ; then
# no serial, broken device
# has eventually binary junk in vpd
identifier=
if [ -f $controller_dev/../product ] ; then
product="`sed -e 's@^[ -]\{1,\}\|[ -]\{1,\}$@@g;s@[^abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ-_0123456789]@@g' < $controller_dev/../product`"
fi
if [ -f $controller_dev/../manufacturer ] ; then
manufacturer="`sed -e 's@^[ -]\{1,\}\|[ -]\{1,\}$@@g;s@[^abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ-_0123456789]@@g' < $controller_dev/../manufacturer`"
fi
if [ -z "$product" -o -z "$manufacturer" ] ; then
read idvendor < $controller_dev/../idVendor
read idproduct < $controller_dev/../idProduct
identifier="0x${idvendor}-0x${idproduct}"
else
identifier="${manufacturer}-${product}"
fi
d="usb-${identifier}"
fi
d="$d:$cil"
RESULT=0
}
handle_block () {
full_sysfs_class_path="$SYSFS$DEVPATH"
if [ ! -f $full_sysfs_class_path/dev ] ; then return ; fi
# the main device has (hopefully) a symlink to the real device
# a partition is a subdir of the main (raw) device
if [ ! -L $full_sysfs_class_path/device ] ; then
if [ -f $full_sysfs_class_path/range ] ; then return ; fi
full_sysfs_class_path="${full_sysfs_class_path%/*}"
: full_sysfs_class_path "$full_sysfs_class_path"
if [ ! -L $full_sysfs_class_path/device -o ! -f $full_sysfs_class_path/dev ] ; then
return
fi
fi
cd $full_sysfs_class_path/device
full_sysfs_device_path="`$pwd_cmd`"
cd "$OPWD"
D=$full_sysfs_device_path
case "$D" in
*/ide[0-9]/[0-9].[0-9]*|*/ide[0-9][0-9]/[0-9][0-9].[0-9]*)
handle_block_ide "$D"
;;
*/usb[0-9]*/[0-9]*/host[0-9]*/[0-9]*:[0-9]*:[0-9]*:[0-9]*)
handle_block_usb_storage "$D"
;;
*/css0/*)
if [ -r $full_sysfs_device_path/wwpn ]; then
read wwpn < $full_sysfs_device_path/wwpn
fi
if [ -r $full_sysfs_device_path/fcp_lun ]; then
read lun < $full_sysfs_device_path/fcp_lun
fi
if [ -r $full_sysfs_device_path/hba_id ]; then
read bus_id < $full_sysfs_device_path/hba_id
fi
if [ "$bus_id" -a "$wwpn" -a "$lun" ]; then
# S/390 zfcp adapter
d="ccw-$bus_id-zfcp-$wwpn:$lun"
RESULT=0
else
# DASD devices
bus="ccw"
adapter=${D##*/}
d="$bus-$adapter"
RESULT=0
fi
;;
*/host[0-9]*/[0-9]*:[0-9]*:[0-9]*:[0-9]*)
# check for ieee1394 sbp2
if test -f $D/ieee1394_id ; then
read ieee1394_id < $D/ieee1394_id
d="`echo ieee1394-${ieee1394_id} | sed -e 's@:@-@g'`"
RESULT=0
else
handle_block_scsi "$D"
fi
;;
*)
: not handled
RESULT=1
return
;;
esac
# look for a partition
if [ "$full_sysfs_class_path" != "$SYSFS$DEVPATH" ] ; then
dp="`echo $SYSFS$DEVPATH | sed -e 's@^/.*/@@;s@^[^0-9]\{1,\}@@;s@.*_@@'`"
case "$d" in
*[0-9])
d="${d}p${dp}"
;;
*)
d="${d}${dp}"
;;
esac
fi
# done
echo "ID_PATH=$d"
}
case "$TYPE" in
block)
handle_block
;;
*)
RESULT=1
;;
esac
exit $RESULT