2024-09-10 22:42:50 +03:00
<?xml version="1.0"?>
<!-- * - nxml - * -->
< !DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd" [
<!ENTITY % entities SYSTEM "custom-entities.ent" >
%entities;
]>
<!-- SPDX - License - Identifier: LGPL - 2.1 - or - later -->
<refentry id= "org.freedesktop.timesync1" conditional= 'ENABLE_TIMESYNCD'
xmlns:xi="http://www.w3.org/2001/XInclude">
<refentryinfo >
<title > org.freedesktop.timesync1</title>
<productname > systemd</productname>
</refentryinfo>
<refmeta >
<refentrytitle > org.freedesktop.timesync1</refentrytitle>
<manvolnum > 5</manvolnum>
</refmeta>
<refnamediv >
<refname > org.freedesktop.timesync1</refname>
<refpurpose > The D-Bus interface of systemd-timesyncd</refpurpose>
</refnamediv>
<refsect1 >
<title > Introduction</title>
<para >
<citerefentry > <refentrytitle > systemd-timesyncd.service</refentrytitle> <manvolnum > 8</manvolnum> </citerefentry>
is a system service that may be used to synchronize the local system clock with a remote Network Time
Protocol (NTP) server. This page describes the D-Bus interface.</para>
</refsect1>
<refsect1 >
<title > The Manager Object</title>
<para > The service exposes the following interfaces on the Manager object on the bus:</para>
<programlisting executable= "systemd-timesyncd" node= "/org/freedesktop/timesync1" interface= "org.freedesktop.timesync1.Manager" >
node /org/freedesktop/timesync1 {
interface org.freedesktop.timesync1.Manager {
methods:
SetRuntimeNTPServers(in as runtime_servers);
properties:
readonly as LinkNTPServers = ['...', ...];
readonly as SystemNTPServers = ['...', ...];
readonly as RuntimeNTPServers = ['...', ...];
readonly as FallbackNTPServers = ['...', ...];
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
readonly s ServerName = '...';
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
readonly (iay) ServerAddress = ...;
@org.freedesktop.DBus.Property.EmitsChangedSignal("const")
readonly t RootDistanceMaxUSec = ...;
@org.freedesktop.DBus.Property.EmitsChangedSignal("const")
readonly t PollIntervalMinUSec = ...;
@org.freedesktop.DBus.Property.EmitsChangedSignal("const")
readonly t PollIntervalMaxUSec = ...;
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
readonly t PollIntervalUSec = ...;
readonly (uuuuittayttttbtt) NTPMessage = ...;
@org.freedesktop.DBus.Property.EmitsChangedSignal("false")
readonly x Frequency = ...;
};
interface org.freedesktop.DBus.Peer { ... };
interface org.freedesktop.DBus.Introspectable { ... };
interface org.freedesktop.DBus.Properties { ... };
};
2024-11-07 18:47:48 +03:00
</programlisting>
2024-09-10 22:42:50 +03:00
<!-- method SetRuntimeNTPServers is not documented! -->
<!-- property LinkNTPServers is not documented! -->
<!-- property SystemNTPServers is not documented! -->
<!-- property RuntimeNTPServers is not documented! -->
<!-- property FallbackNTPServers is not documented! -->
<!-- property ServerName is not documented! -->
<!-- property ServerAddress is not documented! -->
<!-- property RootDistanceMaxUSec is not documented! -->
<!-- property PollIntervalMinUSec is not documented! -->
<!-- property PollIntervalMaxUSec is not documented! -->
<!-- property PollIntervalUSec is not documented! -->
<!-- property NTPMessage is not documented! -->
<!-- property Frequency is not documented! -->
<!-- Autogenerated cross - references for systemd.directives, do not edit -->
<variablelist class= "dbus-interface" generated= "True" extra-ref= "org.freedesktop.timesync1.Manager" />
<variablelist class= "dbus-interface" generated= "True" extra-ref= "org.freedesktop.timesync1.Manager" />
<variablelist class= "dbus-method" generated= "True" extra-ref= "SetRuntimeNTPServers()" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "LinkNTPServers" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "SystemNTPServers" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "RuntimeNTPServers" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "FallbackNTPServers" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "ServerName" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "ServerAddress" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "RootDistanceMaxUSec" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "PollIntervalMinUSec" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "PollIntervalMaxUSec" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "PollIntervalUSec" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "NTPMessage" />
<variablelist class= "dbus-property" generated= "True" extra-ref= "Frequency" />
<!-- End of Autogenerated section -->
<para >
Provides information about the manager.
</para>
</refsect1>
<refsect1 >
<title > Examples</title>
<example >
<title > Introspect <interfacename > org.freedesktop.timesync1.Manager</interfacename> on the bus</title>
<programlisting >
$ gdbus introspect --system \
--dest org.freedesktop.timesync1 \
--object-path /org/freedesktop/timesync1
2024-11-07 18:47:48 +03:00
</programlisting>
2024-09-10 22:42:50 +03:00
</example>
</refsect1>
<xi:include href= "org.freedesktop.locale1.xml" xpointer= "versioning" />
2024-11-05 16:20:01 +03:00
<refsect1 >
<title > See Also</title>
<para > <simplelist type= "inline" >
<member > <citerefentry > <refentrytitle > systemd</refentrytitle> <manvolnum > 1</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > systemd-timesync.service</refentrytitle> <manvolnum > 8</manvolnum> </citerefentry> </member>
</simplelist> </para>
</refsect1>