2018-07-03 00:15:39 +03:00
<?xml version='1.0'?>
2019-03-14 16:40:58 +03:00
< !DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
2023-12-25 17:48:33 +03:00
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd">
2016-06-21 18:52:32 +03:00
<!--
2020-11-09 07:23:58 +03:00
SPDX-License-Identifier: LGPL-2.1-or-later
2017-11-18 19:22:32 +03:00
2018-06-12 20:00:24 +03:00
Copyright © 2016 Julian Orth
2016-06-21 18:52:32 +03:00
-->
2018-12-12 14:31:05 +03:00
<refentry id= "sd_bus_process" xmlns:xi= "http://www.w3.org/2001/XInclude" >
2016-06-21 18:52:32 +03:00
<refentryinfo >
<title > sd_bus_process</title>
<productname > systemd</productname>
</refentryinfo>
<refmeta >
<refentrytitle > sd_bus_process</refentrytitle>
<manvolnum > 3</manvolnum>
</refmeta>
<refnamediv >
<refname > sd_bus_process</refname>
<refpurpose > Drive the connection</refpurpose>
</refnamediv>
<refsynopsisdiv >
<funcsynopsis >
<funcsynopsisinfo > #include < systemd/sd-bus.h> </funcsynopsisinfo>
<funcprototype >
<funcdef > int <function > sd_bus_process</function> </funcdef>
<paramdef > sd_bus *<parameter > bus</parameter> </paramdef>
2018-12-12 14:31:05 +03:00
<paramdef > sd_bus_message **<parameter > ret</parameter> </paramdef>
2016-06-21 18:52:32 +03:00
</funcprototype>
</funcsynopsis>
</refsynopsisdiv>
<refsect1 >
<title > Description</title>
2023-11-16 13:12:00 +03:00
<para > <function > sd_bus_process()</function> drives the connection between the client and the message bus.
That is, it handles connecting, authentication, and processing of messages. When invoked, pending I/O
work is executed, and queued incoming messages are dispatched to registered callbacks. Each time it is
invoked a single operation is executed. It returns zero when no operations were pending and positive if a
message was processed. When zero is returned the caller should poll for I/O events before calling into
<function > sd_bus_process()</function> again. For that either use the simple, blocking
<citerefentry > <refentrytitle > sd_bus_wait</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> call, or
hook up the bus connection object to an external or manual event loop using
2018-12-12 14:31:05 +03:00
<citerefentry > <refentrytitle > sd_bus_get_fd</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> .
2016-06-21 18:52:32 +03:00
</para>
2024-09-12 15:13:22 +03:00
<para > <function > sd_bus_process()</function> processes at most one incoming message per call. If the
parameter <parameter > ret</parameter> is not <constant > NULL</constant> and the call processed a message,
<parameter > *ret</parameter> is set to this message. The caller owns a reference to this message and
should call
<citerefentry > <refentrytitle > sd_bus_message_unref</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry>
when the message is no longer needed. If <parameter > ret</parameter> is not <constant > NULL</constant> and
progress was made, but no message was processed, <parameter > *ret</parameter> is set to
<constant > NULL</constant> . Note that only messages not already handled by the various types of registered
message handlers (i.e. by filters registered via
<citerefentry > <refentrytitle > sd_bus_add_filter</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> ,
object handlers registered via
<citerefentry > <refentrytitle > sd_bus_add_object</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> ,
matches registered via
<citerefentry > <refentrytitle > sd_bus_add_match</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> ,
and related) will be returned through this parameter. Also note that if such a message handler returns a
zero return value (as opposed to some value > 0) an incoming message will not be considered handled,
and be passed to other suitable handlers (until one returns > > 0), or returned by
<function > sd_bus_process()</function> (in case none returns > 0).</para>
2018-12-12 14:31:05 +03:00
2020-11-13 10:19:49 +03:00
<para > If the bus object is connected to an
2018-12-12 14:31:05 +03:00
<citerefentry > <refentrytitle > sd-event</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> event loop (with
<citerefentry > <refentrytitle > sd_bus_attach_event</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> ), it is not
necessary to call <function > sd_bus_process()</function> directly as it is invoked automatically when
necessary.</para>
2016-06-21 18:52:32 +03:00
</refsect1>
<refsect1 >
<title > Return Value</title>
2019-03-21 16:53:00 +03:00
<para > If progress was made, a positive integer is returned. If no progress was made, 0 is returned. If an
error occurs, a negative <varname > errno</varname> -style error code is returned.</para>
2016-06-21 18:52:32 +03:00
2019-03-21 16:53:00 +03:00
<refsect2 >
<title > Errors</title>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<para > Returned errors may indicate the following problems:</para>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<variablelist >
<varlistentry >
<term > <constant > -EINVAL</constant> </term>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<listitem > <para > An invalid bus object was passed.</para> </listitem>
</varlistentry>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<varlistentry >
<term > <constant > -ECHILD</constant> </term>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<listitem > <para > The bus connection was allocated in a parent process and is being reused in a child
process after <function > fork()</function> .</para> </listitem>
</varlistentry>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<varlistentry >
<term > <constant > -ENOTCONN</constant> </term>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<listitem > <para > The bus connection has been terminated already.</para> </listitem>
</varlistentry>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<varlistentry >
<term > <constant > -ECONNRESET</constant> </term>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<listitem > <para > The bus connection has been terminated just now.</para> </listitem>
</varlistentry>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<varlistentry >
<term > <constant > -EBUSY</constant> </term>
2018-12-12 14:31:05 +03:00
2019-03-21 16:53:00 +03:00
<listitem > <para > This function is already being called, i.e. <function > sd_bus_process()</function>
has been called from a callback function that itself was called by
<function > sd_bus_process()</function> .</para> </listitem>
</varlistentry>
</variablelist>
</refsect2>
2018-12-12 14:31:05 +03:00
</refsect1>
<xi:include href= "libsystemd-pkgconfig.xml" />
2023-09-04 15:46:35 +03:00
<refsect1 >
<title > History</title>
2024-04-18 03:45:51 +03:00
<para > <function > sd_bus_process()</function> was added in version 221.</para>
2023-09-04 15:46:35 +03:00
</refsect1>
2016-06-21 18:52:32 +03:00
<refsect1 >
<title > See Also</title>
2023-12-22 21:09:32 +03:00
<para > <simplelist type= "inline" >
<member > <citerefentry > <refentrytitle > systemd</refentrytitle> <manvolnum > 1</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd-bus</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd_bus_wait</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd_bus_get_fd</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd_bus_message_unref</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd-event</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
<member > <citerefentry > <refentrytitle > sd_bus_attach_event</refentrytitle> <manvolnum > 3</manvolnum> </citerefentry> </member>
</simplelist> </para>
2016-06-21 18:52:32 +03:00
</refsect1>
</refentry>