man: be even more explicit that RestartPreventExitStatus= does not affect ExecStartPre=
The man page was already pretty clear about this, but apparently not clear enough, let's hence extend this further. Fixes: #11868
This commit is contained in:
parent
6c8a2c6793
commit
5763971014
@ -807,24 +807,26 @@
|
||||
|
||||
<varlistentry>
|
||||
<term><varname>RestartPreventExitStatus=</varname></term>
|
||||
<listitem><para>Takes a list of exit status definitions that,
|
||||
when returned by the main service process, will prevent
|
||||
automatic service restarts, regardless of the restart setting
|
||||
configured with <varname>Restart=</varname>. Exit status
|
||||
definitions can either be numeric exit codes or termination
|
||||
signal names, and are separated by spaces. Defaults to the
|
||||
empty list, so that, by default, no exit status is excluded
|
||||
from the configured restart logic. For example:
|
||||
|
||||
<listitem><para>Takes a list of exit status definitions that, when returned by the main service
|
||||
process, will prevent automatic service restarts, regardless of the restart setting configured with
|
||||
<varname>Restart=</varname>. Exit status definitions can either be numeric exit codes or termination
|
||||
signal names, and are separated by spaces. Defaults to the empty list, so that, by default, no exit
|
||||
status is excluded from the configured restart logic. For example:
|
||||
|
||||
<programlisting>RestartPreventExitStatus=1 6 SIGABRT</programlisting>
|
||||
|
||||
ensures that exit codes 1 and 6 and the termination signal
|
||||
<constant>SIGABRT</constant> will not result in automatic
|
||||
service restarting. This option may appear more than once, in
|
||||
which case the list of restart-preventing statuses is
|
||||
merged. If the empty string is assigned to this option, the
|
||||
list is reset and all prior assignments of this option will
|
||||
have no effect.</para></listitem>
|
||||
ensures that exit codes 1 and 6 and the termination signal <constant>SIGABRT</constant> will not
|
||||
result in automatic service restarting. This option may appear more than once, in which case the list
|
||||
of restart-preventing statuses is merged. If the empty string is assigned to this option, the list is
|
||||
reset and all prior assignments of this option will have no effect.</para>
|
||||
|
||||
<para>Note that this setting has no effect on processes configured via
|
||||
<varname>ExecStartPre=</varname>, <varname>ExecStartPost=</varname>, <varname>ExecStop=</varname>,
|
||||
<varname>ExecStopPost=</varname> or <varname>ExecReload=</varname>, but only on the main service
|
||||
process, i.e. either the one invoked by <varname>ExecStart=</varname> or (depending on
|
||||
<varname>Type=</varname>, <varname>PIDFile=</varname>, …) the otherwise configured main
|
||||
process.</para></listitem>
|
||||