IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
The maximum allowed value of the sysfs device index entry was limited to
16383 (2^14-1) to avoid the generation of unreasonable onboard interface
names.
For s390 the index can assume a value of up to 65535 (2^16-1) which is
now allowed depending on the new naming flag NAMING_16BIT_INDEX.
Larger index values are considered unreasonable and remain to be
ignored.
The s390 PCI driver assigns the hotplug slot name from the
function_id attribute of the PCI device using a 8 char hexadecimal
format to match the underlying firmware/hypervisor notation.
Further, there's always a one-to-one mapping between a PCI
function and a hotplug slot, as individual functions can
hot plugged even for multi-function devices.
As the generic matching code will always try to parse the slot
name in /sys/bus/pci/slots as a positive decimal number, either
a wrong value might be produced for ID_NET_NAME_SLOT if
the slot name consists of decimal numbers only, or none at all
if a character in the range from 'a' to 'f' is encountered.
Additionally, the generic code assumes that two interfaces
share a hotplug slot, if they differ only in the function part
of the PCI address. E.g., for an interface with the PCI address
dddd:bb:aa.f, it will match the device to the first slot with
an address dddd:bb:aa. As more than one slot may have this address
for the s390 PCI driver, the wrong slot may be selected.
To resolve this we're adding a new naming schema version with the
flag NAMING_SLOT_FUNCTION_ID, which enables the correct matching
of hotplug slots if the device has an attribute named function_id.
The ID_NET_NAME_SLOT property will only be produced if there's
a file /sys/bus/pci/slots/<slotname> where <slotname> matches
the value of /sys/bus/pci/devices/.../function_id in 8 char
hex notation.
Fixes#19016
See also #19078
v246 is long released. Hence the new scheme should be named v247.
(Interesting, how we pretty systematically for the last releases changed
the scheme only every second release)
This is for 6d36464065. It turns out that this is causing more problems than
expected. Let's retroactively introduce naming scheme v241 to conditionalize
this change.
Follow-up for #12792 and 6d36464065. See also
https://bugzilla.suse.com/show_bug.cgi?id=1136600.
$ SYSTEMD_LOG_LEVEL=debug NET_NAMING_SCHEME=v240 build/udevadm test-builtin net_setup_link /sys/class/net/br11
$ SYSTEMD_LOG_LEVEL=debug NET_NAMING_SCHEME=v241 build/udevadm test-builtin net_setup_link /sys/class/net/br11
...
@@ -20,11 +20,13 @@
link_config: could not set ethtool features for br11
Could not set offload features of br11: Operation not permitted
br11: Device has name_assign_type=3
-Using interface naming scheme 'v240'.
+Using interface naming scheme 'v241'.
br11: Policy *keep*: keeping existing userspace name
br11: Device has addr_assign_type=1
-br11: No stable identifying information found
-br11: Could not generate persistent MAC: No data available
+br11: Using "br11" as stable identifying information
+br11: Using generated persistent MAC address
+Could not set Alias=, MACAddress= or MTU= on br11: Operation not permitted
+br11: Could not apply link config, ignoring: Operation not permitted
Unload module index
Unloaded link configuration context.
ID_NET_DRIVER=bridge
This is in preparation for later changes. Let's change the documentation of
net.naming-scheme= to also say that it applies to MAC addresses. This commit
doesn't actually implement that though.
The comment in udev-builtin-net_id.c (removed in grandparent commit) showed the
property without the prefix. I assume that was always the intent, because it
doesn't make much sense to concatenate anything to an arbitrary user-specified
field.
I decided to make this a separate man page because it is freakin' long.
This content could equally well go in systemd-udevd.service(8), systemd.link(5),
or a new man page for the net_id builtin.
v2:
- rename to systemd.net-naming-scheme
- add udevadm test-builtin net_id example