The atmel driver sets a default resolution of 20 for each touchpads it
creates. On this model, 10 is more appropriate.
The resolution is not set for the touchscreen by the kernel, so match
the name to both touchpad and touchscreen.
The Lenovo X230 advertize a vertical resolution of 136, which gives a true
size of 31 mm. The actual physical size of the touchpad is 40 mm, so
override the resolution to 100.
The pointingstick of the Dell Latitude E6400 is somewhat slow by default,
whereas the pointingstick of the Dell Latitude D620 is much too fast by
default, set POINTINGSTICK_CONST_ACCEL for both of them to adjust for this.
Lenovo has changed the sensitivity of the trackpoint on the x240 / T440s / T540
generation of Thinkpads, making them somewhat insensitive by default, add a
hwdb entry to tweak the sensitivity setting.
The ThinkPad X200s is way way too slow by default and unless you push the
trackpoint quite hard only sends delta events in the 1-2 range, tweak the
sensitivity to make it send a wider range of deltas and apply a const accel
factor to make it have a more reasonable speed by default.
IBM / Lenovo trackpoints allow specifying a sensitivity setting through a
ps/2 command, which changes the range of the deltas sent when using the
trackpoint.
On some models with normal usage only deltas of 1 or 2 are send, resulting in
there only being 2 mouse cursor movement speeds, rather than the expected fluid
scale. Changing the sensitivity to a higher level than the bootup default fixes
this.
This commit adds support for setting a POINTINGSTICK_SENSITIVITY value
in hwdb to allow changing the sensitivity on boot through udev / hwdb.
There is quite a wide spread in the delta events generated by pointingsticks,
some generate deltas of 1-2 under normal use, while others generate deltas
from 1-20.
This commit adds a hwdb file which allows specifying a per model
POINTINGSTICK_CONST_ACCEL value which can be used by the userspace input stack
to normalize the deltas so that all pointingsticks get the same feeling ootb.
The hwdb matching re-uses the existing 60-evdev.rules.
Verified for the 5,1 Macbook, the others are guesses based on the list of
supported devices of the moshi trackpad protector.
http://www.moshi.com/trackpad-protector-trackguard-macbook-pro#silver
Resolution calculated based on the min/max settings set in the kernel driver,
divided by the physical size. This is probably slightly off, but still better
than no resolution at all.
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
Parse properties in the form
EVDEV_ABS_00="<min>:<max>:<res>:<fuzz>:<flat>"
and apply them to the kernel device. Future processes that open that device
will see the updated EV_ABS range.
This is particularly useful for touchpads that don't provide a resolution in
the kernel driver but can be fixed up through hwdb entries (e.g. bcm5974).
All values in the property are optional, e.g. a string of "::45" is valid to
set the resolution to 45.
The order intentionally orders resolution before fuzz and flat despite it
being the last element in the absinfo struct. The use-case for setting
fuzz/flat is almost non-existent, resolution is probably the most common case
we'll need.
To avoid multiple hwdb invocations for the same device, replace the
hwdb "keyboard:" prefix with "evdev:" and drop the separate 60-keyboard.rules
file. The new 60-evdev.rules is called for all event nodes
anyway, we don't need a separate rules file and second callout to the hwdb
builtin.
This reverts commit ba76ee29bc. As it turns
out, we need to match on driver=atkbd to not load the fixups on any
plugged USB devices.
That is, whenever you use "name:<name>:dmi:<dmi>" style matches, you
better provide a name or you're screwing things up.
Currently, we always run
hwdb 'keyboard:name:$attr{name}:$attr{[dmi/id]modalias}'
as last step to match keyboards. Therefore, if nothing else matched so
far, we still try the device-name+dmi combination.
However, we have a special atkbd rule which is only run for atkbd as:
hwdb 'keyboard:$attr{[dmi/id]modalias}'
This is redundant, as we already pass the same information to hwdb in the
last fallback step.
This patch converts the hwdb "keyboard:dmi:*" matches to
"keyboard:name:*:dmi:*" matches and drops the redundant rule.
There is no reason to match on usb-modaliases, if we can use the
input-modalias to achieve the same. This commit changes the
keyboard-lookups to not be restricted to USB, but pass all modaliases to
the hwdb. Furthermore, we convert all usb:* matches to input:* matches,
thus getting rid of any ambiguity if multiple usb devices are chained (or
a bluetooth device / etc. is on top).
Note that legacy keyboard:usb:* matches are still supported, but
deprecated. If possible, please use keyboard:input:* matches instead.
This is a required step to make other input devices work with
60-keyboard.hwdb. Other bus-types are often chained on usb and we want to
avoid any ambiguity here if we incorrectly match on a USB hub.
ThinkPad tablet firmware has DMI product name and version reversed:
Handle 0x0001, DMI type 1, 27 bytes
System Information
Manufacturer: LENOVO
Product Name: 7762AS1
Version: ThinkPad X61 Tablet
Serial Number: LKZCDH2
UUID: 6ADBC681-4FC9-11CB-844F-B47CB9210BE2
Wake-up Type: Power Switch
SKU Number: Not Specified
Family: ThinkPad X61 Tablet
On these several HP laptops, the microphone mute hotkey is "Fn+F8" and
the scancode for this hotkey is 0x81, but this scancode was mapped to
fn_esc in the HP generic keymap section. To fix this problem, we add
a machine specific keymap section to add the correct keymap rule.
BugLink: https://bugs.launchpad.net/bugs/1409721
BugLink: https://bugs.launchpad.net/bugs/1334968
Signed-off-by: Hui Wang <hui.wang@canonical.com>
Currently used to tag devices in the new Lenovo *50 series and the X1 Carbon
3rd. These laptops re-introduced the physical trackpoint buttons that were
missing from the *40 series but those buttons are now wired up to the
touchpad.
The touchpad now sends BTN_0, BTN_1 and BTN_2 for the trackpoint. The same
button codes were used in older touchpads that had dedicated scroll up/down
buttons. Input drivers need to work around this and thus know what they're
dealing with.
For the previous gen we introduced INPUT_PROP_TOPBUTTONPAD in the kernel, but
the resulting mess showed that these per-device quirks should really live in
userspace.
The list currently includes the X1 Carbon 3rd PNPID, others will be added as
get to know which PNPID they have.
Some time ago 95-keymap.rules was replaced by
60-keyboard.hwdb. Original comments for MSI laptops (that were in
95-keymap.rules) were removed, but I think they are important for
understanding what's going on.
https://bugs.freedesktop.org/show_bug.cgi?id=88412
Most mice have a wheel click angle of 15 degrees, i.e. 24 clicks per full
wheel rotation. Some mice, like the Logitech M325 have a larger angle. To
allow userspace to make use of that knowledge, add a property to the hwdb.
This allows for better predictive scrolling. e.g. a mouse that has a smaller
click angle will scroll faster, with this value you can accommodate this
where needed. Likewise, using "half turn of the wheel" or "full turn of the
wheel" as a UI element becomes possible.
This addition is mainly driven by libinput 0.8, having the angle enables
libinput to provide an API that distinguishes between a physical distance
(like touchpad scrolling does) and discrete steps (wheel clicks).
Callers can choose what they prefer based on the device.
Error, DATA expected but got 'mouse:usb:v046dpc24c:name:Logitech G400s Optical
Gaming Mouse:' in '/etc/udev/hwdb.d/70-mouse.hwdb':
Error, MATCH expected but got ' MOUSE_DPI=400@1000 *800@1000 2000@1000
4000@1000' in '/etc/udev/hwdb.d/70-mouse.hwdb':
Introduced in 6366e349
Reporter says he incorrectly measured the data but the device is not available
anymore to correct it. We'll have to wait for someone else to submit the data.
https://bugs.freedesktop.org/show_bug.cgi?id=87343