busctlsystemdbusctl1busctlIntrospect the busbusctlOPTIONSCOMMANDNAMEDescriptionbusctl may be used to
introspect and monitor the D-Bus bus.CommandsThe following commands are understood:listShow all peers on the bus, by their service
names. By default, shows both unique and well-known names, but
this may be changed with the and
switches. This is the default
operation if no command is specified.statusSERVICEShow process information and credentials of a
bus service (if one is specified by its unique or well-known
name), a process (if one is specified by its numeric PID), or
the owner of the bus (if no parameter is
specified).monitorSERVICEDump messages being exchanged. If
SERVICE is specified, show messages
to or from this peer, identified by its well-known or unique
name. Otherwise, show all messages on the bus. Use
CtrlC
to terminate the dump.captureSERVICESimilar to monitor but
writes the output in pcapng format (for details, see
PCAP Next Generation (pcapng) Capture File Format).
Make sure to redirect standard output to a file or pipe. Tools like
wireshark1
may be used to dissect and view the resulting
files.treeSERVICEShows an object tree of one or more
services. If SERVICE is specified,
show object tree of the specified services only. Otherwise,
show all object trees of all services on the bus that acquired
at least one well-known name.introspectSERVICEOBJECTINTERFACEShow interfaces, methods, properties and
signals of the specified object (identified by its path) on
the specified service. If the interface argument is passed, the
output is limited to members of the specified
interface.callSERVICEOBJECTINTERFACEMETHODSIGNATUREARGUMENTInvoke a method and show the response. Takes a
service name, object path, interface name and method name. If
parameters shall be passed to the method call, a signature
string is required, followed by the arguments, individually
formatted as strings. For details on the formatting used, see
below. To suppress output of the returned data, use the
option.emitOBJECTINTERFACESIGNALSIGNATUREARGUMENTEmit a signal. Takes an object path, interface name and method name. If parameters
shall be passed, a signature string is required, followed by the arguments, individually formatted as
strings. For details on the formatting used, see below. To specify the destination of the signal,
use the option.get-propertySERVICEOBJECTINTERFACEPROPERTYRetrieve the current value of one or more
object properties. Takes a service name, object path,
interface name and property name. Multiple properties may be
specified at once, in which case their values will be shown one
after the other, separated by newlines. The output is, by
default, in terse format. Use for a
more elaborate output format.set-propertySERVICEOBJECTINTERFACEPROPERTYSIGNATUREARGUMENTSet the current value of an object
property. Takes a service name, object path, interface name,
property name, property signature, followed by a list of
parameters formatted as strings.helpShow command syntax help.OptionsThe following options are understood:Connect to the bus specified by
ADDRESS instead of using suitable
defaults for either the system or user bus (see
and
options).When showing the list of peers, show a
column containing the names of containers they belong to.
See
systemd-machined.service8.
When showing the list of peers, show only
"unique" names (of the form
:number.number).
The opposite of —
only "well-known" names will be shown.When showing the list of peers, show only
peers which have actually not been activated yet, but may be
started automatically if accessed.When showing messages being exchanged, show only the
subset matching MATCH.
See
sd_bus_add_match3.
When used with the capture command,
specifies the maximum bus message size to capture
("snaplen"). Defaults to 4096 bytes.When used with the tree command, shows a
flat list of object paths instead of a tree.When used with the call command,
suppresses display of the response message payload. Note that even
if this option is specified, errors returned will still be
printed and the tool will indicate success or failure with
the process exit code.When used with the call or
get-property command, shows output in a
more verbose format.When used with the introspect call, dump the XML description received from
the D-Bus org.freedesktop.DBus.Introspectable.Introspect call instead of the
normal output.MODEWhen used with the call or get-property command, shows output
formatted as JSON. Expects one of short (for the shortest possible output without any
redundant whitespace or line breaks) or pretty (for a pretty version of the same, with
indentation and line breaks). Note that transformation from D-Bus marshalling to JSON is done in a loss-less
way, which means type information is embedded into the JSON object tree.Equivalent to when invoked interactively from a terminal. Otherwise
equivalent to , in particular when the output is piped to some other
program.BOOLWhen used with the call command,
specifies whether busctl shall wait for
completion of the method call, output the returned method
response data, and return success or failure via the process
exit code. If this is set to no, the
method call will be issued but no response is expected, the
tool terminates immediately, and thus no response can be
shown, and no success or failure is returned via the exit
code. To only suppress output of the reply message payload,
use above. Defaults to
yes.BOOLWhen used with the call or emit command, specifies
whether the method call should implicitly activate the
called service, should it not be running yet but is
configured to be auto-started. Defaults to
yes.BOOLWhen used with the call command,
specifies whether the services may enforce interactive
authorization while executing the operation, if the security
policy is configured for this. Defaults to
yes.SECSWhen used with the call command,
specifies the maximum time to wait for method call
completion. If no time unit is specified, assumes
seconds. The usual other units are understood, too (ms, us,
s, min, h, d, w, month, y). Note that this timeout does not
apply if is used, as the
tool does not wait for any reply message then. When not
specified or when set to 0, the default of
25s is assumed.BOOLControls whether credential data reported by
list or status shall
be augmented with data from
/proc/. When this is turned on, the data
shown is possibly inconsistent, as the data read from
/proc/ might be more recent than the rest of
the credential information. Defaults to yes.BOOLControls whether to wait for the specified AF_UNIX bus socket to appear in the
file system before connecting to it. Defaults to off. When enabled, the tool will watch the file system until
the socket is created and then connect to it.SERVICETakes a service name. When used with the emit command, a signal is
emitted to the specified service.Do not ellipsize the output in list command.Parameter FormattingThe call and
set-property commands take a signature string
followed by a list of parameters formatted as string (for details
on D-Bus signature strings, see the Type
system chapter of the D-Bus specification). For simple
types, each parameter following the signature should simply be the
parameter's value formatted as string. Positive boolean values may
be formatted as true, yes,
on, or 1; negative boolean
values may be specified as false,
no, off, or
0. For arrays, a numeric argument for the
number of entries followed by the entries shall be specified. For
variants, the signature of the contents shall be specified,
followed by the contents. For dictionaries and structs, the
contents of them shall be directly specified.For example,
s jawoll is the formatting
of a single string jawoll.as 3 hello world foobar
is the formatting of a string array with three entries,
hello, world and
foobar.a{sv} 3 One s Eins Two u 2 Yes b true
is the formatting of a dictionary
array that maps strings to variants, consisting of three
entries. The string One is assigned the
string Eins. The string
Two is assigned the 32-bit unsigned
integer 2. The string Yes is assigned a
positive boolean.Note that the call,
get-property, introspect
commands will also generate output in this format for the returned
data. Since this format is sometimes too terse to be easily
understood, the call and
get-property commands may generate a more
verbose, multi-line output when passed the
option.ExamplesWrite and Read a PropertyThe following two commands first write a property and then
read it back. The property is found on the
/org/freedesktop/systemd1 object of the
org.freedesktop.systemd1 service. The name of
the property is LogLevel on the
org.freedesktop.systemd1.Manager
interface. The property contains a single string:# busctl set-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager LogLevel s debug
# busctl get-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager LogLevel
s "debug"Terse and Verbose OutputThe following two commands read a property that contains
an array of strings, and first show it in terse format, followed
by verbose format:$ busctl get-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager Environment
as 2 "LANG=en_US.UTF-8" "PATH=/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin"
$ busctl get-property --verbose org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager Environment
ARRAY "s" {
STRING "LANG=en_US.UTF-8";
STRING "PATH=/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin";
};Invoking a MethodThe following command invokes the
StartUnit method on the
org.freedesktop.systemd1.Manager
interface of the
/org/freedesktop/systemd1 object
of the org.freedesktop.systemd1
service, and passes it two strings
cups.service and
replace. As a result of the method
call, a single object path parameter is received and
shown:# busctl call org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager StartUnit ss "cups.service" "replace"
o "/org/freedesktop/systemd1/job/42684"See Alsodbus-daemon1D-Bussd-bus3varlinkctl1systemd1machinectl1wireshark1