sd_bus_get_fd
systemd
sd_bus_get_fd
3
sd_bus_get_fd
sd_bus_set_fd
sd_bus_get_events
sd_bus_get_timeout
Get the file descriptor, I/O events and timeout to wait for from a message bus
object
#include <systemd/sd-bus.h>
int sd_bus_get_fd
sd_bus *bus
int sd_bus_set_fd
sd_bus *bus
int input_fd
int output_fd
int sd_bus_get_events
sd_bus *bus
int sd_bus_get_timeout
sd_bus *bus
uint64_t *timeout_usec
Description
sd_bus_get_fd() returns the file descriptor used to communicate from
a message bus object. This descriptor can be used with
poll3
or a similar function to wait for I/O events on the specified bus connection object. If the bus
object was configured with the sd_bus_set_fd() function, then the
input_fd file descriptor used in that call is returned.
sd_bus_set_fd() sets the file descriptors used to communicate from a
message bus object. Both input_fd and output_fd
must be valid file descriptors. The same file descriptor may be used as both the input and the
output file descriptor. This function must be called before the bus is started.
sd_bus_get_events() returns the I/O events to wait for, suitable for
passing to poll() or a similar call. Returns a combination of
POLLIN, POLLOUT, … events, or negative on error.
sd_bus_get_timeout() returns the timeout in µs to pass to
poll() or a similar call when waiting for events on the specified bus
connection. The returned timeout may be zero, in which case a subsequent I/O polling call
should be invoked in non-blocking mode. The returned timeout may be
UINT64_MAX in which case the I/O polling call may block indefinitely,
without any applied timeout. Note that the returned timeout should be considered only a
maximum sleeping time. It is permissible (and even expected) that shorter timeouts are used by
the calling program, in case other event sources are polled in the same event loop. Note that
the returned time-value is relative and specified in microseconds. When converting this value in
order to pass it as third argument to poll() (which expects milliseconds),
care should be taken to use a division that rounds up to ensure the I/O polling operation
doesn't sleep for shorter than necessary, which might result in unintended busy looping
(alternatively, use
ppoll2
instead of plain poll(), which understands timeouts with nano-second
granularity).
These three functions are useful to hook up a bus connection object with an external or
manual event loop involving poll() or a similar I/O polling call. Before
each invocation of the I/O polling call, all three functions should be invoked: the file
descriptor returned by sd_bus_get_fd() should be polled for the events
indicated by sd_bus_get_events(), and the I/O call should block for that up
to the timeout returned by sd_bus_get_timeout(). After each I/O polling
call the bus connection needs to process incoming or outgoing data, by invoking
sd_bus_process3.
Note that these functions are only one of three supported ways to implement I/O event
handling for bus connections. Alternatively use
sd_bus_attach_event3
to attach a bus connection to an
sd-event3
event loop. Or use
sd_bus_wait3
as a simple synchronous, blocking I/O waiting call.
Return Value
On success, sd_bus_get_fd() returns the file descriptor used for
communication. On failure, it returns a negative errno-style error code.
On success, sd_bus_set_fd() returns a non-negative integer. On
failure, it returns a negative errno-style error code.
On success, sd_bus_get_events() returns the I/O event mask to use for
I/O event watching. On failure, it returns a negative errno-style error code.
On success, sd_bus_get_timeout() returns a non-negative integer. On
failure, it returns a negative errno-style error code.
Errors
Returned errors may indicate the following problems:
-EINVAL
An invalid bus object was passed.
-ECHILD
The bus connection was allocated in a parent process and is being reused
in a child process after fork().
-ENOTCONN
The bus connection has been terminated.
-EPERM
Two distinct file descriptors were passed for input and output using
sd_bus_set_fd(), which sd_bus_get_fd() cannot
return.
-EBADF
An invalid file descriptor was passed to
sd_bus_set_fd().
-ENOPKG
The bus cannot be resolved.
See Also
systemd1,
sd-bus3,
sd_bus_process3,
sd_bus_attach_event3,
sd_bus_wait3,
poll3