mirror of
https://github.com/systemd/systemd.git
synced 2024-10-30 14:55:37 +03:00
b23b11719d
I noticed a typo in the man page. Fix it.
Fixes: 65c2ad985a
("udev: net_id: Use devicetree aliases when available")
556 lines
29 KiB
XML
556 lines
29 KiB
XML
<?xml version='1.0'?>
|
||
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
|
||
"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
|
||
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
|
||
|
||
<refentry id="systemd.net-naming-scheme">
|
||
<refentryinfo>
|
||
<title>systemd.net-naming-scheme</title>
|
||
<productname>systemd</productname>
|
||
</refentryinfo>
|
||
|
||
<refmeta>
|
||
<refentrytitle>systemd.net-naming-scheme</refentrytitle>
|
||
<manvolnum>7</manvolnum>
|
||
</refmeta>
|
||
|
||
<refnamediv>
|
||
<refname>systemd.net-naming-scheme</refname>
|
||
<refpurpose>Network device naming schemes</refpurpose>
|
||
</refnamediv>
|
||
|
||
<refsect1>
|
||
<title>Description</title>
|
||
|
||
<para>Network interfaces names and MAC addresses may be generated based on certain stable interface
|
||
attributes. This is possible when there is enough information about the device to generate those
|
||
attributes and the use of this information is configured. This page describes interface naming, i.e. what
|
||
possible names may be generated. Those names are generated by the
|
||
<citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
||
builtin <command>net_id</command> and exported as udev properties
|
||
(<varname>ID_NET_NAME_ONBOARD=</varname>, <varname>ID_NET_LABEL_ONBOARD=</varname>,
|
||
<varname>ID_NET_NAME_PATH=</varname>, <varname>ID_NET_NAME_SLOT=</varname>).</para>
|
||
|
||
<para>Names and MAC addresses are derived from various stable device metadata attributes. Newer versions
|
||
of udev take more of these attributes into account, improving (and thus possibly changing) the names and
|
||
addresses used for the same devices. Different versions of those generation rules are called "naming
|
||
schemes". The default naming scheme is chosen at compilation time. Usually this will be the latest
|
||
implemented version, but it is also possible to set one of the older versions to preserve
|
||
compatibility. This may be useful for example for distributions, which may introduce new versions of
|
||
systemd in stable releases without changing the naming scheme. The naming scheme may also be overridden
|
||
using the <varname>net.naming-scheme=</varname> kernel command line switch, see
|
||
<citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>.
|
||
Available naming schemes are described below.</para>
|
||
|
||
<para>After the udev properties have been generated, appropriate udev rules may be used to actually rename
|
||
devices based on those properties. See the description of <varname>NamePolicy=</varname> and
|
||
<varname>MACAddressPolicy=</varname> in
|
||
<citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>.</para>
|
||
|
||
<para>Note that while the concept of network interface naming schemes is primarily relevant in the
|
||
context of <filename>systemd-udevd.service</filename>, the
|
||
<citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
|
||
container manager also takes it into account when naming network interfaces, see below.</para>
|
||
</refsect1>
|
||
|
||
<refsect1>
|
||
<title>Naming</title>
|
||
|
||
<para>All names start with a two-character prefix that signifies the interface type.</para>
|
||
|
||
<table>
|
||
<title>Two character prefixes based on the type of interface</title>
|
||
|
||
<tgroup cols='2'>
|
||
<thead>
|
||
<row>
|
||
<entry>Prefix</entry>
|
||
<entry>Description</entry>
|
||
</row>
|
||
</thead>
|
||
<tbody>
|
||
<row>
|
||
<entry><constant>en</constant></entry>
|
||
<entry>Ethernet</entry>
|
||
</row>
|
||
<row>
|
||
<entry><constant>ib</constant></entry>
|
||
<entry>InfiniBand</entry>
|
||
</row>
|
||
<row>
|
||
<entry><constant>sl</constant></entry>
|
||
<entry>Serial line IP (slip)</entry>
|
||
</row>
|
||
<row>
|
||
<entry><constant>wl</constant></entry>
|
||
<entry>Wireless local area network (WLAN)</entry>
|
||
</row>
|
||
<row>
|
||
<entry><constant>ww</constant></entry>
|
||
<entry>Wireless wide area network (WWAN)</entry>
|
||
</row>
|
||
</tbody>
|
||
</tgroup>
|
||
</table>
|
||
|
||
<para>The udev <command>net_id</command> builtin exports the following udev device properties:</para>
|
||
|
||
<variablelist>
|
||
<varlistentry>
|
||
<term><varname>ID_NET_NAME_ONBOARD=<replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_ONBOARD=<replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></varname></term>
|
||
|
||
<listitem><para>This name is set based on the numeric ordering information given by the firmware
|
||
for on-board devices. Different schemes are used depending on the firmware type, as described in the table below.</para>
|
||
|
||
<table>
|
||
<title>Onboard naming schemes</title>
|
||
|
||
<tgroup cols='2'>
|
||
<thead>
|
||
<row>
|
||
<entry>Format</entry>
|
||
<entry>Description</entry>
|
||
</row>
|
||
</thead>
|
||
|
||
<tbody>
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></entry>
|
||
<entry>PCI onboard index</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></entry>
|
||
<entry>Devicetree alias index</entry>
|
||
</row>
|
||
|
||
</tbody>
|
||
</tgroup>
|
||
</table>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><varname>ID_NET_LABEL_ONBOARD=<replaceable>prefix</replaceable> <replaceable>label</replaceable></varname></term>
|
||
|
||
<listitem><para>This property is set based on textual label given by the firmware for on-board
|
||
devices. The name consists of the prefix concatenated with the label. This is only available for
|
||
PCI devices.
|
||
</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><varname>ID_NET_NAME_MAC=<replaceable>prefix</replaceable><constant>x</constant><replaceable>AABBCCDDEEFF</replaceable></varname></term>
|
||
|
||
<listitem><para>This name consists of the prefix, letter <constant>x</constant>, and 12 hexadecimal
|
||
digits of the MAC address. It is available if the device has a fixed MAC address. Because this name
|
||
is based on an attribute of the card itself, it remains "stable" when the device is moved (even
|
||
between machines), but will change when the hardware is replaced.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable><constant>v</constant><replaceable>slot</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable><constant>x</constant><replaceable>slot</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term>
|
||
<term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>v</constant><replaceable>slot</replaceable></varname></term>
|
||
|
||
<listitem><para>This property describes the slot position. Different schemes are used depending on
|
||
the bus type, as described in the table below. In case of USB, BCMA, and SR-VIO devices, the full
|
||
name consists of the prefix, PCI slot identifier, and USB or BCMA or SR-VIO slot identifier. The
|
||
first two parts are denoted as "…" in the table below.</para>
|
||
|
||
<table>
|
||
<title>Slot naming schemes</title>
|
||
|
||
<tgroup cols='2'>
|
||
<thead>
|
||
<row>
|
||
<entry>Format</entry>
|
||
<entry>Description</entry>
|
||
</row>
|
||
</thead>
|
||
|
||
<tbody>
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
|
||
<entry>PCI slot number</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> <constant>v</constant><replaceable>slot</replaceable></entry>
|
||
<entry>VIO slot number (IBM PowerVM)</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> <constant>X</constant><replaceable>number</replaceable></entry>
|
||
<entry>VIF interface number (Xen)</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry>… <constant>b</constant><replaceable>number</replaceable></entry>
|
||
<entry>Broadcom bus (BCMA) core number</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
|
||
<entry>USB port number chain</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry>… <constant>v</constant><replaceable>slot</replaceable></entry>
|
||
<entry>SR-VIO slot number</entry>
|
||
</row>
|
||
</tbody>
|
||
</tgroup>
|
||
</table>
|
||
|
||
<para>The PCI domain is only prepended when it is not 0. All multi-function PCI devices will carry
|
||
the <constant>f<replaceable>function</replaceable></constant> number in the device name, including
|
||
the function 0 device. For non-multi-function devices, the number is suppressed if 0. The port name
|
||
<replaceable>port_name</replaceable> is used, or the port number
|
||
<constant>d</constant><replaceable>dev_port</replaceable> if the name is not known.</para>
|
||
|
||
<para>For BCMA devices, the core number is suppressed when 0.</para>
|
||
|
||
<para>For USB devices the full chain of port numbers of hubs is composed. If the name gets longer
|
||
than the maximum number of 15 characters, the name is not exported. The usual USB configuration
|
||
number 1 and interface number 0 values are suppressed.</para>
|
||
|
||
<para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
|
||
<constant>v</constant> and the virtual device number, with any leading zeros removed. The bus
|
||
number is ignored.</para>
|
||
|
||
<para>In some configurations a parent PCI bridge of a given network controller may be associated
|
||
with a slot. In such case we don't generate this device property to avoid possible naming conflicts.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>c</constant><replaceable>bus_id</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>a</constant><replaceable>vendor</replaceable><replaceable>model</replaceable><constant>i</constant><replaceable>instance</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>i</constant><replaceable>address</replaceable><constant>n</constant><replaceable>port_name</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term>
|
||
<term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term>
|
||
|
||
<listitem><para>This property describes the device installation location. Different schemes are
|
||
used depending on the bus type, as described in the table below. For BCMA and USB devices, PCI path
|
||
information must known, and the full name consists of the prefix, PCI slot identifier, and USB or
|
||
BCMA location. The first two parts are denoted as "…" in the table below.</para>
|
||
|
||
<table>
|
||
<title>Path naming schemes</title>
|
||
|
||
<tgroup cols='2'>
|
||
<thead>
|
||
<row>
|
||
<entry>Format</entry>
|
||
<entry>Description</entry>
|
||
</row>
|
||
</thead>
|
||
|
||
<tbody>
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> <constant>c</constant><replaceable>bus_id</replaceable></entry>
|
||
<entry>CCW or grouped CCW device identifier</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> <constant>a</constant><replaceable>vendor</replaceable> <replaceable>model</replaceable> <constant>i</constant><replaceable>instance</replaceable></entry>
|
||
<entry>ACPI path names for ARM64 platform devices</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> <constant>i</constant><replaceable>address</replaceable> <constant>n</constant><replaceable>port_name</replaceable></entry>
|
||
<entry>Netdevsim (simulated networking device) device number and port name</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>p</constant><replaceable>bus</replaceable> <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>phys_port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
|
||
<entry>PCI geographical location</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry>… <constant>b</constant><replaceable>number</replaceable></entry>
|
||
<entry>Broadcom bus (BCMA) core number</entry>
|
||
</row>
|
||
|
||
<row>
|
||
<entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
|
||
<entry>USB port number chain</entry>
|
||
</row>
|
||
|
||
</tbody>
|
||
</tgroup>
|
||
</table>
|
||
|
||
<para>CCW and grouped CCW devices are found in IBM System Z mainframes. Any leading zeros and
|
||
dots are suppressed.</para>
|
||
|
||
<para>For PCI, BCMA, and USB devices, the same rules as described above for slot naming are
|
||
used.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
</variablelist>
|
||
</refsect1>
|
||
|
||
<refsect1>
|
||
<title>History</title>
|
||
|
||
<para>The following "naming schemes" have been defined (which may be chosen at system boot-up time via
|
||
the <varname>net.naming-scheme=</varname> kernel command line switch, see above):</para>
|
||
|
||
<variablelist>
|
||
<varlistentry>
|
||
<term><constant>v238</constant></term>
|
||
|
||
<listitem><para>This is the naming scheme that was implemented in systemd 238.</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v239</constant></term>
|
||
|
||
<listitem><para>Naming was changed for virtual network interfaces created with SR-IOV and NPAR and
|
||
for devices where the PCI network controller device does not have a slot number associated.</para>
|
||
|
||
<para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
|
||
<literal>v<replaceable>port</replaceable></literal>, where <replaceable>port</replaceable> is the
|
||
virtual device number. Previously those virtual devices were named as if completely independent.
|
||
</para>
|
||
|
||
<para>The ninth and later NPAR virtual devices are named following the scheme used for the first
|
||
eight NPAR partitions. Previously those devices were not renamed and the kernel default
|
||
("eth<replaceable>N</replaceable>") was used.</para>
|
||
|
||
<para>Names are also generated for PCI devices where the PCI network controller device does not
|
||
have an associated slot number itself, but one of its parents does. Previously those devices were
|
||
not renamed and the kernel default was used.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v240</constant></term>
|
||
|
||
<listitem><para>The <literal>ib</literal> prefix and stable names for infiniband devices are
|
||
introduced. Previously those devices were not renamed.</para>
|
||
|
||
<para>The ACPI index field (used in <varname>ID_NET_NAME_ONBOARD=</varname>) is now also used when
|
||
0.</para>
|
||
|
||
<para>A new naming policy <varname>NamePolicy=keep</varname> was introduced. With this policy, if
|
||
the network device name was already set by userspace, the device will not be renamed
|
||
again. Previously, this naming policy applied implicitly, and now it must be explicitly
|
||
requested. Effectively, this means that network devices will be renamed according to the
|
||
configuration, even if they have been renamed already, if <constant>keep</constant> is not
|
||
specified as the naming policy in the <filename index="false">.link</filename> file. See
|
||
<citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
||
for a description of <varname>NamePolicy=</varname>.</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v241</constant></term>
|
||
|
||
<listitem><para><option>MACAddressPolicy=persistent</option> was extended to set MAC addresses
|
||
based on the device name. Previously addresses were only based on the
|
||
<varname index="false">ID_NET_NAME_*</varname> attributes, which meant that interface names would
|
||
never be generated for virtual devices. Now a persistent address will be generated for most
|
||
devices, including in particular bridges.</para>
|
||
|
||
<para>Note: when userspace does not set a MAC address for a bridge device, the kernel will
|
||
initially assign a random address, and then change it when the first device is enslaved to the
|
||
bridge. With this naming policy change, bridges get a persistent MAC address based on the bridge
|
||
name instead of the first enslaved device.</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v243</constant></term>
|
||
|
||
<listitem><para>Support for renaming netdevsim (simulated networking) devices was added. Previously
|
||
those devices were not renamed.</para>
|
||
|
||
<para>Previously two-letter interface type prefix was prepended to
|
||
<varname>ID_NET_LABEL_ONBOARD=</varname>. This is not done anymore.</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v245</constant></term>
|
||
|
||
<listitem><para>When
|
||
<citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
|
||
derives the name for the host side of the network interface created with
|
||
<option>--network-veth</option> from the container name it previously simply truncated the result
|
||
at 15 characters if longer (since that's the maximum length for network interface names). From now
|
||
on, for any interface name that would be longer than 15 characters the last 4 characters are set to
|
||
a 24bit hash value of the full interface name. This way network interface name collisions between
|
||
multiple similarly named containers (who only differ in container name suffix) should be less
|
||
likely (but still possible, since the 24bit hash value is very small).</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v247</constant></term>
|
||
|
||
<listitem><para>When a PCI slot is associated with a PCI bridge that has multiple child network
|
||
controllers, the same value of the <varname>ID_NET_NAME_SLOT</varname> property might be derived
|
||
for those controllers. This would cause a naming conflict if the property is selected as the device
|
||
name. Now, we detect this situation and don't produce the <varname>ID_NET_NAME_SLOT</varname>
|
||
property.</para></listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v249</constant></term>
|
||
|
||
<listitem><para>PCI hotplug slot names for the s390 PCI driver are a hexadecimal representation
|
||
of the <filename>function_id</filename> device attribute. This attribute is now used to build the
|
||
<varname>ID_NET_NAME_SLOT</varname>. Before that, all slot names were parsed as decimal
|
||
numbers, which could either result in an incorrect value of the <varname>ID_NET_NAME_SLOT</varname>
|
||
property or none at all.</para>
|
||
|
||
<para>Some firmware and hypervisor implementations report unreasonably high numbers for the onboard
|
||
index. To prevent the generation of bogus onbard interface names, index numbers greater than 16381
|
||
(2¹⁴-1) were ignored. For s390 PCI devices index values up to 65535 (2¹⁶-1) are valid. To account
|
||
for that, the limit was increased to 65535.</para>
|
||
|
||
<para>The udev rule <varname>NAME=</varname> replaces <literal>:</literal>,
|
||
<literal>/</literal>, and <literal>%</literal> with an underscore (<literal>_</literal>), and
|
||
refuses strings which contain only numerics.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v250</constant></term>
|
||
|
||
<listitem><para>Added naming scheme for Xen netfront "vif" interfaces based on the guest side
|
||
VIF number set from the Xen config (or the interface index in AWS EC2).</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v251</constant></term>
|
||
|
||
<listitem><para>Since version <constant>v247</constant> we no longer set
|
||
<varname>ID_NET_NAME_SLOT</varname> if we detect that a PCI device associated with a slot is a PCI
|
||
bridge as that would create naming conflict when there are more child devices on that bridge. Now,
|
||
this is relaxed and we will use slot information to generate the name based on it but only if
|
||
the PCI device has multiple functions. This is safe because distinct function number is a part of
|
||
the device name for multifunction devices.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
<varlistentry>
|
||
<term><constant>v252</constant></term>
|
||
|
||
<listitem><para>Added naming scheme for platform devices with devicetree aliases.</para>
|
||
</listitem>
|
||
</varlistentry>
|
||
|
||
</variablelist>
|
||
|
||
<para>Note that <constant>latest</constant> may be used to denote the latest scheme known (to this
|
||
particular version of systemd).</para>
|
||
</refsect1>
|
||
|
||
<refsect1>
|
||
<title>Examples</title>
|
||
|
||
<example>
|
||
<title>Using <command>udevadm test-builtin</command> to display device properties</title>
|
||
|
||
<programlisting>$ udevadm test-builtin net_id /sys/class/net/enp0s31f6
|
||
...
|
||
Using default interface naming scheme 'v243'.
|
||
ID_NET_NAMING_SCHEME=v243
|
||
ID_NET_NAME_MAC=enx54ee75cb1dc0
|
||
ID_OUI_FROM_DATABASE=Wistron InfoComm(Kunshan)Co.,Ltd.
|
||
ID_NET_NAME_PATH=enp0s31f6
|
||
...</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>PCI Ethernet card with firmware index "1"</title>
|
||
|
||
<programlisting>ID_NET_NAME_ONBOARD=eno1
|
||
ID_NET_NAME_ONBOARD_LABEL=Ethernet Port 1
|
||
</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>PCI Ethernet card in hotplug slot with firmware index number</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:1c.3/0000:05:00.0/net/ens1
|
||
ID_NET_NAME_MAC=enx000000000466
|
||
ID_NET_NAME_PATH=enp5s0
|
||
ID_NET_NAME_SLOT=ens1</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>PCI Ethernet multi-function card with 2 ports</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.0/net/enp2s0f0
|
||
ID_NET_NAME_MAC=enx78e7d1ea46da
|
||
ID_NET_NAME_PATH=enp2s0f0
|
||
|
||
# /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.1/net/enp2s0f1
|
||
ID_NET_NAME_MAC=enx78e7d1ea46dc
|
||
ID_NET_NAME_PATH=enp2s0f1</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>PCI WLAN card</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:1c.1/0000:03:00.0/net/wlp3s0
|
||
ID_NET_NAME_MAC=wlx0024d7e31130
|
||
ID_NET_NAME_PATH=wlp3s0</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>PCI IB host adapter with 2 ports</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.0/net/ibp21s0f0
|
||
ID_NET_NAME_PATH=ibp21s0f0
|
||
|
||
# /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.1/net/ibp21s0f1
|
||
ID_NET_NAME_PATH=ibp21s0f1</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>USB built-in 3G modem</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.4/2-1.4:1.6/net/wwp0s29u1u4i6
|
||
ID_NET_NAME_MAC=wwx028037ec0200
|
||
ID_NET_NAME_PATH=wwp0s29u1u4i6</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>USB Android phone</title>
|
||
|
||
<programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.2/2-1.2:1.0/net/enp0s29u1u2
|
||
ID_NET_NAME_MAC=enxd626b3450fb5
|
||
ID_NET_NAME_PATH=enp0s29u1u2</programlisting>
|
||
</example>
|
||
|
||
<example>
|
||
<title>s390 grouped CCW interface</title>
|
||
|
||
<programlisting># /sys/devices/css0/0.0.0007/0.0.f5f0/group_device/net/encf5f0
|
||
ID_NET_NAME_MAC=enx026d3c00000a
|
||
ID_NET_NAME_PATH=encf5f0</programlisting>
|
||
</example>
|
||
</refsect1>
|
||
|
||
<refsect1>
|
||
<title>See Also</title>
|
||
<para>
|
||
<citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>,
|
||
<citerefentry><refentrytitle>udevadm</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
||
<ulink url="https://systemd.io/PREDICTABLE_INTERFACE_NAMES">Predictable Network Interface Names</ulink>,
|
||
<citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
|
||
</para>
|
||
</refsect1>
|
||
|
||
</refentry>
|