1
0
mirror of https://github.com/systemd/systemd.git synced 2024-12-25 01:34:28 +03:00
systemd/test/TEST-16-EXTEND-TIMEOUT/testsuite-success-all.service
Daniel Black a327431bd1 core: add EXTEND_TIMEOUT_USEC={usec} - prevent timeouts in startup/runtime/shutdown (#7214)
With Type=notify services, EXTEND_TIMEOUT_USEC= messages will delay any startup/
runtime/shutdown timeouts.

A service that hasn't timed out, i.e, start time < TimeStartSec,
runtime < RuntimeMaxSec and stop time < TimeoutStopSec, may by sending
EXTEND_TIMEOUT_USEC=, allow the service to continue beyond the limit for
the execution phase (i.e TimeStartSec, RunTimeMaxSec and TimeoutStopSec).

EXTEND_TIMEOUT_USEC= must continue to be sent (in the same way as
WATCHDOG=1) within the time interval specified to continue to reprevent
the timeout from occuring.

Watchdog timeouts are also extended if a EXTEND_TIMEOUT_USEC is greater
than the remaining time on the watchdog counter.

Fixes #5868.
2017-12-14 12:17:43 +01:00

15 lines
603 B
Desktop File

[Unit]
Description=Testsuite: EXTEND_TIMEOUT_USEC Success - extend timeout on all services
[Service]
# Normal success - startup / runtime / shutdown all take 8 seconds which is within the EXTEND_TIMEOUT_USEC=4 seconds interval
# runtime is 8+8+8 seconds. so we are relying on the EXTEND_TIMEOUT_USEC to exceed all stages, Start, Runtime and Stop.
# success occurs after 24 seconds
Type=notify
TimeoutStartSec=4
TimeoutStopSec=4
RuntimeMaxSec=4
ExecStart=/extend_timeout_test_service.sh SERVICE=success_all extend_timeout_interval=4 sleep_interval=2 start_intervals=3 run_intervals=3 stop_intervals=3