IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
a directory, the errno returned could end up as ENOENT rather than ENOTDIR.
- Fixes some compiler warnings which showed up on IRIX, as reported by
James Peach.
(This used to be commit 615a62b21f)
DNS names (realms) from NetBIOS domain names.
Until now, we would experience delays as we broadcast lookups for DNS names
onto the local network segments.
Now if DNS comes back negative, we fall straight back to looking up the
short name.
Andrew Bartlett
(This used to be commit 32397c8b01)
- Make winbindd try to use kerberos for connections to DCs, so that it can
access RA=2 servers, particularly for netlogon.
- Make rpcclient follow the new flags for the NETLOGON pipe
- Make all the code that uses schannel use the centralised functions for doing so.
Andrew Bartlett
(This used to be commit 96b4187963)
It was caused by the winbind_ping() call in is_trusted_domain()
o if we are a DC then we check our own direct trust relationships
we have to rely on winbindd to update the truatdom_cache
o if we are a domain member, then we can update the trustdom_cache
ourselves if winbindd is not there
(This used to be commit 22dfcafb37)
* is_trusted_domain() is broken without winbind. Still working on this.
* get_global_sam_name() should return the workgroup name unless we
are a standalone server (verified by volker)
* Get_Pwnam() should always fall back to the username (minus domain name)
even if it is not our workgroup so that TRUSTEDOMAIN\user can logon
if 'user' exists in the local list of accounts (on domain members w/o
winbind)
Tested using Samba PDC with trusts (running winbindd) and a Samba 3.0
domain member not running winbindd.
notes: make_user_info_map() is slightly broken now due to the
fact that is_trusted_domain() only works with winbindd. disabled
checks temporarily until I can sort this out.
(This used to be commit e1d6094d06)
workstation, we have to use the workstation type, if we have a BDC account,
we must use the BDC type - even if we are pretending to be a workstation
at the moment.
Also actually store and retreive the last change time, so we can do
periodic password changes again (for RPC at least).
And finally, a couple of minor fixes to 'net'.
Andrew Bartlett
(This used to be commit 6e6b7b79ed)