IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
The reason for this is that some systems include
<rpc/rpc.h> from within system headers. HP-UX 11.00
does so somewhere deep inside of <shadow.h>.
For torture/winbind/struct_based.c <rpc/rpc.h> resolves
to torture/rpc/rpc.h and breaks the build.
metze
Upstream subunit makes a ":" after commands optional, so I've fixed any
places where we might trigger commands accidently. I've filed a bug
about this in subunit.
Find the "Enterprise Admins" group which does exist on s4 and Windows
directories and is always per default universal. Test this only when the target
is set to s4 (s3 deployments don't contain this group). If the number of
returned objects is "0" (count) then we are likely testing the builtin domain of
an AD deployment.Then we ignore the inexistent "Enterprise Admins" group.
I didn't enhance the test for "QueryDomainInfo" since this does itself a
comparison of all returned objects with the "EnumDomainGroups" call. Therefore
if the latter passes, and the "QueryDomainInfo" test passes also the
"QueryDomainInfo" call is okay regarding groups.
After looking at the s4 side of the (s)channel :) I found out that it makes
more sense to simply make it use the tdb based code than redo the same changes
done to s3 to simplify the interface.
Ldb is slow, to the point it needs haks to pre-open the db to speed it up, yet
that does not solve the lookup speed, with ldb it is always going to be slower.
Looking through the history it is evident that the schannel database doesn't
really need greate expanadability. And lookups are always done with a single
Key. This seem a perfet fit for tdb while ldb looks unnecessarily complicated.
The schannel database is not really a persistent one. It can be discared during
an upgrade without causing any real issue. all it contains is temproary session
data.
Used in several places.
(Note: The _level suffix in the function name is just because
test_QueryDomainInfo2() already exists as an overall test for all levels.)
Michael
Signed-off-by: Günther Deschner <gd@samba.org>
This tests account lockout features.
Windows 2003r2 and Windows 2008r2 survice this test.
Note: Windows does not set the ACB_AUTOLOCK account flag when it
locks out an account.
One thing that could/should be added to this test is a check of
the lockout time property.
Michael
This test checks the behavior (since w2k3 sp1) of the badPwdCount samr attribute
in relation to password history and successfull and unsucessful netlogon
samlogons.
Michael, please check. This should help verifiying Bug #4347.
Guenther