mirror of
https://github.com/samba-team/samba.git
synced 2024-12-25 23:21:54 +03:00
d7cfb12bf3
One dependency of includes.h less Signed-off-by: Volker Lendecke <vl@samba.org> Reviewed-by: Jeremy Allison <jra@samba.org> Autobuild-User(master): Jeremy Allison <jra@samba.org> Autobuild-Date(master): Tue Apr 24 22:26:22 CEST 2018 on sn-devel-144
500 lines
13 KiB
C
500 lines
13 KiB
C
/*
|
|
Unix SMB/Netbios implementation.
|
|
Version 3.0
|
|
printing backend routines
|
|
Copyright (C) Andrew Tridgell 1992-2000
|
|
Copyright (C) Jeremy Allison 2002
|
|
Copyright (C) Simo Sorce 2011
|
|
|
|
This program is free software; you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation; either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include "includes.h"
|
|
#include "smbd/globals.h"
|
|
#include "include/messages.h"
|
|
#include "lib/util/util_process.h"
|
|
#include "printing.h"
|
|
#include "printing/pcap.h"
|
|
#include "printing/queue_process.h"
|
|
#include "locking/proto.h"
|
|
#include "smbd/smbd.h"
|
|
#include "rpc_server/rpc_config.h"
|
|
#include "printing/load.h"
|
|
#include "rpc_server/spoolss/srv_spoolss_nt.h"
|
|
#include "auth.h"
|
|
#include "nt_printing.h"
|
|
#include "util_event.h"
|
|
|
|
extern pid_t start_spoolssd(struct tevent_context *ev_ctx,
|
|
struct messaging_context *msg_ctx);
|
|
|
|
/**
|
|
* @brief Purge stale printers and reload from pre-populated pcap cache.
|
|
*
|
|
* This function should normally only be called as a callback on a successful
|
|
* pcap_cache_reload().
|
|
*
|
|
* This function can cause DELETION of printers and drivers from our registry,
|
|
* so calling it on a failed pcap reload may REMOVE permanently all printers
|
|
* and drivers.
|
|
*
|
|
* @param[in] ev The event context.
|
|
*
|
|
* @param[in] msg_ctx The messaging context.
|
|
*/
|
|
static void delete_and_reload_printers_full(struct tevent_context *ev,
|
|
struct messaging_context *msg_ctx)
|
|
{
|
|
struct auth_session_info *session_info = NULL;
|
|
struct spoolss_PrinterInfo2 *pinfo2 = NULL;
|
|
int n_services;
|
|
int pnum;
|
|
int snum;
|
|
const char *pname;
|
|
const char *sname;
|
|
NTSTATUS status;
|
|
|
|
n_services = lp_numservices();
|
|
pnum = lp_servicenumber(PRINTERS_NAME);
|
|
|
|
status = make_session_info_system(talloc_tos(), &session_info);
|
|
if (!NT_STATUS_IS_OK(status)) {
|
|
DEBUG(3, ("reload_printers: "
|
|
"Could not create system session_info\n"));
|
|
/* can't remove stale printers before we
|
|
* are fully initilized */
|
|
return;
|
|
}
|
|
|
|
/*
|
|
* Add default config for printers added to smb.conf file and remove
|
|
* stale printers
|
|
*/
|
|
for (snum = 0; snum < n_services; snum++) {
|
|
/* avoid removing PRINTERS_NAME */
|
|
if (snum == pnum) {
|
|
continue;
|
|
}
|
|
|
|
/* skip no-printer services */
|
|
if (!snum_is_shared_printer(snum)) {
|
|
continue;
|
|
}
|
|
|
|
sname = lp_const_servicename(snum);
|
|
pname = lp_printername(session_info, snum);
|
|
|
|
/* check printer, but avoid removing non-autoloaded printers */
|
|
if (lp_autoloaded(snum) && !pcap_printername_ok(pname)) {
|
|
DEBUG(3, ("removing stale printer %s\n", pname));
|
|
|
|
if (is_printer_published(session_info, session_info,
|
|
msg_ctx,
|
|
NULL,
|
|
lp_servicename(session_info,
|
|
snum),
|
|
&pinfo2)) {
|
|
nt_printer_publish(session_info,
|
|
session_info,
|
|
msg_ctx,
|
|
pinfo2,
|
|
DSPRINT_UNPUBLISH);
|
|
TALLOC_FREE(pinfo2);
|
|
}
|
|
nt_printer_remove(session_info, session_info, msg_ctx,
|
|
pname);
|
|
} else {
|
|
DEBUG(8, ("Adding default registry entry for printer "
|
|
"[%s], if it doesn't exist.\n", sname));
|
|
nt_printer_add(session_info, session_info, msg_ctx,
|
|
sname);
|
|
}
|
|
}
|
|
|
|
/* finally, purge old snums */
|
|
delete_and_reload_printers(ev, msg_ctx);
|
|
|
|
TALLOC_FREE(session_info);
|
|
}
|
|
|
|
|
|
/****************************************************************************
|
|
Notify smbds of new printcap data
|
|
**************************************************************************/
|
|
static void reload_pcap_change_notify(struct tevent_context *ev,
|
|
struct messaging_context *msg_ctx)
|
|
{
|
|
/*
|
|
* Reload the printers first in the background process so that
|
|
* newly added printers get default values created in the registry.
|
|
*
|
|
* This will block the process for some time (~1 sec per printer), but
|
|
* it doesn't block smbd's servering clients.
|
|
*/
|
|
delete_and_reload_printers_full(ev, msg_ctx);
|
|
|
|
messaging_send_all(msg_ctx, MSG_PRINTER_PCAP, NULL, 0);
|
|
}
|
|
|
|
struct bq_state {
|
|
struct tevent_context *ev;
|
|
struct messaging_context *msg;
|
|
struct idle_event *housekeep;
|
|
};
|
|
|
|
static bool print_queue_housekeeping(const struct timeval *now, void *pvt)
|
|
{
|
|
struct bq_state *state;
|
|
|
|
state = talloc_get_type_abort(pvt, struct bq_state);
|
|
|
|
DEBUG(5, ("print queue housekeeping\n"));
|
|
pcap_cache_reload(state->ev, state->msg, &reload_pcap_change_notify);
|
|
|
|
return true;
|
|
}
|
|
|
|
static bool printing_subsystem_queue_tasks(struct bq_state *state)
|
|
{
|
|
uint32_t housekeeping_period = lp_printcap_cache_time();
|
|
|
|
/* cancel any existing housekeeping event */
|
|
TALLOC_FREE(state->housekeep);
|
|
|
|
if (housekeeping_period == 0) {
|
|
DEBUG(4, ("background print queue housekeeping disabled\n"));
|
|
return true;
|
|
}
|
|
|
|
state->housekeep = event_add_idle(state->ev, NULL,
|
|
timeval_set(housekeeping_period, 0),
|
|
"print_queue_housekeeping",
|
|
print_queue_housekeeping, state);
|
|
if (state->housekeep == NULL) {
|
|
DEBUG(0,("Could not add print_queue_housekeeping event\n"));
|
|
return false;
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
static void bq_reopen_logs(char *logfile)
|
|
{
|
|
if (logfile) {
|
|
lp_set_logfile(logfile);
|
|
}
|
|
reopen_logs();
|
|
}
|
|
|
|
static void bq_sig_term_handler(struct tevent_context *ev,
|
|
struct tevent_signal *se,
|
|
int signum,
|
|
int count,
|
|
void *siginfo,
|
|
void *private_data)
|
|
{
|
|
exit_server_cleanly("termination signal");
|
|
}
|
|
|
|
static void bq_setup_sig_term_handler(void)
|
|
{
|
|
struct tevent_signal *se;
|
|
|
|
se = tevent_add_signal(server_event_context(),
|
|
server_event_context(),
|
|
SIGTERM, 0,
|
|
bq_sig_term_handler,
|
|
NULL);
|
|
if (!se) {
|
|
exit_server("failed to setup SIGTERM handler");
|
|
}
|
|
}
|
|
|
|
static void bq_sig_hup_handler(struct tevent_context *ev,
|
|
struct tevent_signal *se,
|
|
int signum,
|
|
int count,
|
|
void *siginfo,
|
|
void *pvt)
|
|
{
|
|
struct bq_state *state;
|
|
|
|
state = talloc_get_type_abort(pvt, struct bq_state);
|
|
change_to_root_user();
|
|
|
|
DEBUG(1, ("Reloading pcap cache after SIGHUP\n"));
|
|
pcap_cache_reload(state->ev, state->msg,
|
|
&reload_pcap_change_notify);
|
|
printing_subsystem_queue_tasks(state);
|
|
bq_reopen_logs(NULL);
|
|
}
|
|
|
|
static void bq_setup_sig_hup_handler(struct bq_state *state)
|
|
{
|
|
struct tevent_signal *se;
|
|
|
|
se = tevent_add_signal(state->ev, state->ev, SIGHUP, 0,
|
|
bq_sig_hup_handler, state);
|
|
if (!se) {
|
|
exit_server("failed to setup SIGHUP handler");
|
|
}
|
|
}
|
|
|
|
static void bq_sig_chld_handler(struct tevent_context *ev_ctx,
|
|
struct tevent_signal *se,
|
|
int signum, int count,
|
|
void *siginfo, void *pvt)
|
|
{
|
|
int status;
|
|
pid_t pid;
|
|
|
|
pid = waitpid(-1, &status, WNOHANG);
|
|
if (WIFEXITED(status)) {
|
|
DEBUG(6, ("Bq child process %d terminated with %d\n",
|
|
(int)pid, WEXITSTATUS(status)));
|
|
} else {
|
|
DEBUG(3, ("Bq child process %d terminated abnormally\n",
|
|
(int)pid));
|
|
}
|
|
}
|
|
|
|
static void bq_setup_sig_chld_handler(struct tevent_context *ev_ctx)
|
|
{
|
|
struct tevent_signal *se;
|
|
|
|
se = tevent_add_signal(ev_ctx, ev_ctx, SIGCHLD, 0,
|
|
bq_sig_chld_handler, NULL);
|
|
if (!se) {
|
|
exit_server("failed to setup SIGCHLD handler");
|
|
}
|
|
}
|
|
|
|
static void bq_smb_conf_updated(struct messaging_context *msg_ctx,
|
|
void *private_data,
|
|
uint32_t msg_type,
|
|
struct server_id server_id,
|
|
DATA_BLOB *data)
|
|
{
|
|
struct bq_state *state;
|
|
|
|
state = talloc_get_type_abort(private_data, struct bq_state);
|
|
|
|
DEBUG(10,("smb_conf_updated: Got message saying smb.conf was "
|
|
"updated. Reloading.\n"));
|
|
change_to_root_user();
|
|
pcap_cache_reload(state->ev, msg_ctx, &reload_pcap_change_notify);
|
|
printing_subsystem_queue_tasks(state);
|
|
}
|
|
|
|
static void printing_pause_fd_handler(struct tevent_context *ev,
|
|
struct tevent_fd *fde,
|
|
uint16_t flags,
|
|
void *private_data)
|
|
{
|
|
/*
|
|
* If pause_pipe[1] is closed it means the parent smbd
|
|
* and children exited or aborted.
|
|
*/
|
|
exit_server_cleanly(NULL);
|
|
}
|
|
|
|
/****************************************************************************
|
|
main thread of the background lpq updater
|
|
****************************************************************************/
|
|
pid_t start_background_queue(struct tevent_context *ev,
|
|
struct messaging_context *msg_ctx,
|
|
char *logfile)
|
|
{
|
|
pid_t pid;
|
|
struct bq_state *state;
|
|
|
|
/* Use local variables for this as we don't
|
|
* need to save the parent side of this, just
|
|
* ensure it closes when the process exits.
|
|
*/
|
|
int pause_pipe[2];
|
|
|
|
DEBUG(3,("start_background_queue: Starting background LPQ thread\n"));
|
|
|
|
if (pipe(pause_pipe) == -1) {
|
|
DEBUG(5,("start_background_queue: cannot create pipe. %s\n", strerror(errno) ));
|
|
exit(1);
|
|
}
|
|
|
|
/*
|
|
* Block signals before forking child as it will have to
|
|
* set its own handlers. Child will re-enable SIGHUP as
|
|
* soon as the handlers are set up.
|
|
*/
|
|
BlockSignals(true, SIGTERM);
|
|
BlockSignals(true, SIGHUP);
|
|
|
|
pid = fork();
|
|
|
|
/* parent or error */
|
|
if (pid != 0) {
|
|
/* Re-enable SIGHUP before returnig */
|
|
BlockSignals(false, SIGTERM);
|
|
BlockSignals(false, SIGHUP);
|
|
return pid;
|
|
}
|
|
|
|
if (pid == -1) {
|
|
DEBUG(5,("start_background_queue: background LPQ thread failed to start. %s\n", strerror(errno) ));
|
|
exit(1);
|
|
}
|
|
|
|
if (pid == 0) {
|
|
struct tevent_fd *fde;
|
|
int ret;
|
|
NTSTATUS status;
|
|
|
|
/* Child. */
|
|
DEBUG(5,("start_background_queue: background LPQ thread started\n"));
|
|
|
|
close(pause_pipe[0]);
|
|
pause_pipe[0] = -1;
|
|
|
|
status = smbd_reinit_after_fork(msg_ctx, ev, true, "lpqd");
|
|
|
|
if (!NT_STATUS_IS_OK(status)) {
|
|
DEBUG(0,("reinit_after_fork() failed\n"));
|
|
smb_panic("reinit_after_fork() failed");
|
|
}
|
|
|
|
state = talloc_zero(NULL, struct bq_state);
|
|
if (state == NULL) {
|
|
exit(1);
|
|
}
|
|
state->ev = ev;
|
|
state->msg = msg_ctx;
|
|
|
|
bq_reopen_logs(logfile);
|
|
bq_setup_sig_term_handler();
|
|
bq_setup_sig_hup_handler(state);
|
|
bq_setup_sig_chld_handler(ev);
|
|
|
|
BlockSignals(false, SIGTERM);
|
|
BlockSignals(false, SIGHUP);
|
|
|
|
if (!printing_subsystem_queue_tasks(state)) {
|
|
exit(1);
|
|
}
|
|
|
|
if (!locking_init()) {
|
|
exit(1);
|
|
}
|
|
messaging_register(msg_ctx, state, MSG_SMB_CONF_UPDATED,
|
|
bq_smb_conf_updated);
|
|
messaging_register(msg_ctx, NULL, MSG_PRINTER_UPDATE,
|
|
print_queue_receive);
|
|
/* Remove previous forwarder message set in parent. */
|
|
messaging_deregister(msg_ctx, MSG_PRINTER_DRVUPGRADE, NULL);
|
|
|
|
messaging_register(msg_ctx, NULL, MSG_PRINTER_DRVUPGRADE,
|
|
do_drv_upgrade_printer);
|
|
|
|
fde = tevent_add_fd(ev, ev, pause_pipe[1], TEVENT_FD_READ,
|
|
printing_pause_fd_handler,
|
|
NULL);
|
|
if (!fde) {
|
|
DEBUG(0,("tevent_add_fd() failed for pause_pipe\n"));
|
|
smb_panic("tevent_add_fd() failed for pause_pipe");
|
|
}
|
|
|
|
pcap_cache_reload(ev, msg_ctx, &reload_pcap_change_notify);
|
|
|
|
DEBUG(5,("start_background_queue: background LPQ thread waiting for messages\n"));
|
|
ret = tevent_loop_wait(ev);
|
|
/* should not be reached */
|
|
DEBUG(0,("background_queue: tevent_loop_wait() exited with %d - %s\n",
|
|
ret, (ret == 0) ? "out of events" : strerror(errno)));
|
|
exit(1);
|
|
}
|
|
|
|
close(pause_pipe[1]);
|
|
|
|
return pid;
|
|
}
|
|
|
|
/* Run before the parent forks */
|
|
bool printing_subsystem_init(struct tevent_context *ev_ctx,
|
|
struct messaging_context *msg_ctx,
|
|
bool start_daemons,
|
|
bool background_queue)
|
|
{
|
|
pid_t pid = -1;
|
|
|
|
if (!print_backend_init(msg_ctx)) {
|
|
return false;
|
|
}
|
|
|
|
/* start spoolss daemon */
|
|
/* start as a separate daemon only if enabled */
|
|
if (start_daemons && rpc_spoolss_daemon() == RPC_DAEMON_FORK) {
|
|
|
|
pid = start_spoolssd(ev_ctx, msg_ctx);
|
|
|
|
} else if (start_daemons && background_queue) {
|
|
|
|
pid = start_background_queue(ev_ctx, msg_ctx, NULL);
|
|
|
|
} else {
|
|
bool ret;
|
|
struct bq_state *state;
|
|
|
|
state = talloc_zero(NULL, struct bq_state);
|
|
if (state == NULL) {
|
|
exit(1);
|
|
}
|
|
state->ev = ev_ctx;
|
|
state->msg = msg_ctx;
|
|
|
|
ret = printing_subsystem_queue_tasks(state);
|
|
|
|
/* Publish nt printers, this requires a working winreg pipe */
|
|
pcap_cache_reload(ev_ctx, msg_ctx,
|
|
&delete_and_reload_printers_full);
|
|
|
|
return ret;
|
|
}
|
|
|
|
if (pid == -1) {
|
|
return false;
|
|
}
|
|
background_lpq_updater_pid = pid;
|
|
|
|
return true;
|
|
}
|
|
|
|
void printing_subsystem_update(struct tevent_context *ev_ctx,
|
|
struct messaging_context *msg_ctx,
|
|
bool force)
|
|
{
|
|
if (background_lpq_updater_pid != -1) {
|
|
if (pcap_cache_loaded(NULL)) {
|
|
load_printers(ev_ctx, msg_ctx);
|
|
}
|
|
if (force) {
|
|
/* Send a sighup to the background process.
|
|
* this will force it to reload printers */
|
|
kill(background_lpq_updater_pid, SIGHUP);
|
|
}
|
|
return;
|
|
}
|
|
|
|
pcap_cache_reload(ev_ctx, msg_ctx,
|
|
&delete_and_reload_printers_full);
|
|
}
|