Unix SMB/Netbios implementation.
Version 3.0
printing backend routines
Copyright (C) Andrew Tridgell 1992-2000
Copyright (C) Jeremy Allison 2002
Copyright (C) Simo Sorce 2011
This program is free software; you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation; either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include "includes.h"
#include "smbd/globals.h"
#include "include/messages.h"
#include "printing.h"
#include "printing/pcap.h"
#include "printing/queue_process.h"
#include "serverid.h"
#include "locking/proto.h"
#include "smbd/proto.h"
#include "rpc_server/rpc_service_setup.h"
#include "printing/load.h"
extern pid_t start_spoolssd(struct event_context *ev_ctx,
struct messaging_context *msg_ctx);
/****************************************************************************
Notify smbds of new printcap data
**************************************************************************/
static void reload_pcap_change_notify(struct tevent_context *ev,
struct messaging_context *msg_ctx)
{
message_send_all(msg_ctx, MSG_PRINTER_PCAP, NULL, 0, NULL);
}
static bool print_queue_housekeeping(const struct timeval *now, void *pvt)
{
struct messaging_context *msg_ctx =
talloc_get_type_abort(pvt, struct messaging_context);
time_t printcap_cache_time = (time_t)lp_printcap_cache_time();
time_t t = time_mono(NULL);
DEBUG(5, ("print queue housekeeping\n"));
/* if periodic printcap rescan is enabled,
* see if it's time to reload */
if ((printcap_cache_time != 0) &&
(t >= (last_printer_reload_time + printcap_cache_time))) {
DEBUG( 3,( "Printcap cache time expired.\n"));
pcap_cache_reload(messaging_event_context(msg_ctx),
msg_ctx,
&reload_pcap_change_notify);
last_printer_reload_time = t;
}
return true;
}
static bool printing_subsystem_queue_tasks(struct tevent_context *ev_ctx,
struct messaging_context *msg_ctx)
{
if (!(event_add_idle(ev_ctx, NULL,
timeval_set(SMBD_HOUSEKEEPING_INTERVAL, 0),
"print_queue_housekeeping",
print_queue_housekeeping,
msg_ctx))) {
DEBUG(0, ("Could not add print_queue_housekeeping event\n"));
return false;
}
return true;
}
static void bq_reopen_logs(char *logfile)
{
if (logfile) {
lp_set_logfile(logfile);
}
reopen_logs();
}
static void bq_sig_term_handler(struct tevent_context *ev,
struct tevent_signal *se,
int signum,
int count,
void *siginfo,
void *private_data)
{
exit_server_cleanly("termination signal");
}
static void bq_setup_sig_term_handler(void)
{
struct tevent_signal *se;
se = tevent_add_signal(server_event_context(),
server_event_context(),
SIGTERM, 0,
bq_sig_term_handler,
NULL);
if (!se) {
exit_server("failed to setup SIGTERM handler");
}
}
static void bq_sig_hup_handler(struct tevent_context *ev,
struct tevent_signal *se,
int signum,
int count,
void *siginfo,
void *pvt)
{
struct messaging_context *msg_ctx;
msg_ctx = talloc_get_type_abort(pvt, struct messaging_context);
change_to_root_user();
DEBUG(1, ("Reloading pcap cache after SIGHUP\n"));
pcap_cache_reload(ev, msg_ctx, &reload_pcap_change_notify);
bq_reopen_logs(NULL);
}
static void bq_setup_sig_hup_handler(struct tevent_context *ev,
struct messaging_context *msg_ctx)
{
struct tevent_signal *se;
se = tevent_add_signal(ev, ev, SIGHUP, 0, bq_sig_hup_handler,
msg_ctx);
if (!se) {
exit_server("failed to setup SIGHUP handler");
}
}
static void bq_sig_chld_handler(struct tevent_context *ev_ctx,
struct tevent_signal *se,
int signum, int count,
void *siginfo, void *pvt)
{
int status;
pid_t pid;
pid = sys_waitpid(-1, &status, WNOHANG);
if (WIFEXITED(status)) {
DEBUG(6, ("Bq child process %d terminated with %d\n",
(int)pid, WEXITSTATUS(status)));
} else {
DEBUG(3, ("Bq child process %d terminated abnormally\n",
(int)pid));
}
}
static void bq_setup_sig_chld_handler(struct tevent_context *ev_ctx)
{
struct tevent_signal *se;
se = tevent_add_signal(ev_ctx, ev_ctx, SIGCHLD, 0,
bq_sig_chld_handler, NULL);
if (!se) {
exit_server("failed to setup SIGCHLD handler");
}
}
static void bq_smb_conf_updated(struct messaging_context *msg_ctx,
void *private_data,
uint32_t msg_type,
struct server_id server_id,
DATA_BLOB *data)
{
struct tevent_context *ev_ctx =
talloc_get_type_abort(private_data, struct tevent_context);
DEBUG(10,("smb_conf_updated: Got message saying smb.conf was "
"updated. Reloading.\n"));
change_to_root_user();
pcap_cache_reload(ev_ctx, msg_ctx, &reload_pcap_change_notify);
}
static void printing_pause_fd_handler(struct tevent_context *ev,
struct tevent_fd *fde,
uint16_t flags,
void *private_data)
{
/*
* If pause_pipe[1] is closed it means the parent smbd
* and children exited or aborted.
*/
exit_server_cleanly(NULL);
}
/****************************************************************************
main thread of the background lpq updater
****************************************************************************/
pid_t start_background_queue(struct tevent_context *ev,
struct messaging_context *msg_ctx,
char *logfile)
{
pid_t pid;
/* Use local variables for this as we don't
* need to save the parent side of this, just
* ensure it closes when the process exits.
*/
int pause_pipe[2];
DEBUG(3,("start_background_queue: Starting background LPQ thread\n"));
if (pipe(pause_pipe) == -1) {
DEBUG(5,("start_background_queue: cannot create pipe. %s\n", strerror(errno) ));
exit(1);
}
/*
* Block signals before forking child as it will have to
* set its own handlers. Child will re-enable SIGHUP as
* soon as the handlers are set up.
*/
BlockSignals(true, SIGTERM);
BlockSignals(true, SIGHUP);
pid = sys_fork();
/* parent or error */
if (pid != 0) {
/* Re-enable SIGHUP before returnig */
BlockSignals(false, SIGTERM);
BlockSignals(false, SIGHUP);
return pid;
}
if (pid == -1) {
DEBUG(5,("start_background_queue: background LPQ thread failed to start. %s\n", strerror(errno) ));
exit(1);
}
if (pid == 0) {
struct tevent_fd *fde;
int ret;
NTSTATUS status;
/* Child. */
DEBUG(5,("start_background_queue: background LPQ thread started\n"));
close(pause_pipe[0]);
pause_pipe[0] = -1;
status = reinit_after_fork(msg_ctx, ev, procid_self(), true);
if (!NT_STATUS_IS_OK(status)) {
DEBUG(0,("reinit_after_fork() failed\n"));
smb_panic("reinit_after_fork() failed");
}
bq_reopen_logs(logfile);
bq_setup_sig_term_handler();
bq_setup_sig_hup_handler(ev, msg_ctx);
bq_setup_sig_chld_handler(ev);
BlockSignals(false, SIGTERM);
BlockSignals(false, SIGHUP);
if (!printing_subsystem_queue_tasks(ev, msg_ctx)) {
exit(1);
}
if (!serverid_register(procid_self(),
FLAG_MSG_GENERAL|FLAG_MSG_SMBD
|FLAG_MSG_PRINT_GENERAL)) {
exit(1);
}
if (!locking_init()) {
exit(1);
}
messaging_register(msg_ctx, ev, MSG_SMB_CONF_UPDATED,
bq_smb_conf_updated);
messaging_register(msg_ctx, NULL, MSG_PRINTER_UPDATE,
print_queue_receive);
fde = tevent_add_fd(ev, ev, pause_pipe[1], TEVENT_FD_READ,
printing_pause_fd_handler,
NULL);
if (!fde) {
DEBUG(0,("tevent_add_fd() failed for pause_pipe\n"));
smb_panic("tevent_add_fd() failed for pause_pipe");
}
pcap_cache_reload(ev, msg_ctx, &reload_pcap_change_notify);
DEBUG(5,("start_background_queue: background LPQ thread waiting for messages\n"));
ret = tevent_loop_wait(ev);
/* should not be reached */
DEBUG(0,("background_queue: tevent_loop_wait() exited with %d - %s\n",
ret, (ret == 0) ? "out of events" : strerror(errno)));
exit(1);
}
close(pause_pipe[1]);
return pid;
}
/* Run before the parent forks */
bool printing_subsystem_init(struct tevent_context *ev_ctx,
struct messaging_context *msg_ctx,
bool start_daemons,
bool background_queue)
{
enum rpc_service_mode_e spoolss_mode = rpc_spoolss_mode();
pid_t pid = -1;
if (!print_backend_init(msg_ctx)) {
return false;
}
/* start spoolss daemon */
/* start as a separate daemon only if enabled */
if (start_daemons && spoolss_mode == RPC_SERVICE_MODE_DAEMON) {
pid = start_spoolssd(ev_ctx, msg_ctx);
} else if (start_daemons && background_queue) {
pid = start_background_queue(ev_ctx, msg_ctx, NULL);
} else {
bool ret;
ret = printing_subsystem_queue_tasks(ev_ctx, msg_ctx);
/* Publish nt printers, this requires a working winreg pipe */
pcap_cache_reload(ev_ctx, msg_ctx, &reload_printers);
return ret;
}
if (pid == -1) {
return false;
}
background_lpq_updater_pid = pid;
return true;
}
void printing_subsystem_update(struct tevent_context *ev_ctx,
struct messaging_context *msg_ctx,
bool force)
{
if (background_lpq_updater_pid != -1) {
if (pcap_cache_loaded()) {
load_printers(ev_ctx, msg_ctx);
}
if (force) {
/* Send a sighup to the background process.
* this will force it to reload printers */
kill(background_lpq_updater_pid, SIGHUP);
}
return;
}
pcap_cache_reload(ev_ctx, msg_ctx, &reload_printers);
}