tape: library status: don't fail if the library does not support DVCID

some libraries (e.g. Qualstar) don't support the DVCID bit in the READ
ELEMENT (B8) command (to return vendor/model of connected drives), so
make that part optional if it fails. We only ever use the serial number
in the `pmtx` tool, so there is not much downside to not having this.

This increases compatibility with such libraries

Reported in the forum:
https://forum.proxmox.com/threads/cant-query-tape-robot-status.131833/

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
This commit is contained in:
Dominik Csapak 2023-08-09 11:12:55 +02:00 committed by Dietmar Maurer
parent c884061623
commit dc887e93be

View File

@ -398,20 +398,22 @@ pub fn read_element_status<F: AsRawFd>(file: &mut F) -> Result<MtxStatus, Error>
// get the serial + vendor + model,
// some changer require this to be an extra scsi command
let page = get_element(
// some changers don't support this
if let Ok(page) = get_element(
&mut sg_raw,
ElementType::DataTransferWithDVCID,
allocation_len,
false,
)?;
// should be in same order and same count, but be on the safe side.
// there should not be too many drives normally
for drive in drives.iter_mut() {
for drive2 in &page.drives {
if drive2.element_address == drive.element_address {
drive.vendor = drive2.vendor.clone();
drive.model = drive2.model.clone();
drive.drive_serial_number = drive2.drive_serial_number.clone();
) {
// should be in same order and same count, but be on the safe side.
// there should not be too many drives normally
for drive in drives.iter_mut() {
for drive2 in &page.drives {
if drive2.element_address == drive.element_address {
drive.vendor = drive2.vendor.clone();
drive.model = drive2.model.clone();
drive.drive_serial_number = drive2.drive_serial_number.clone();
}
}
}
}