hwmon: (tmp421) report /PVLD condition as fault
[ Upstream commit540effa7f2
] For both local and remote sensors all the supported ICs can report an "undervoltage lockout" condition which means the conversion wasn't properly performed due to insufficient power supply voltage and so the measurement results can't be trusted. Fixes:9410700b88
("hwmon: Add driver for Texas Instruments TMP421/422/423 sensor chips") Signed-off-by: Paul Fertser <fercerpav@gmail.com> Link: https://lore.kernel.org/r/20210924093011.26083-2-fercerpav@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
ec018021cf
commit
8a07d5aba3
@ -160,10 +160,10 @@ static int tmp421_read(struct device *dev, enum hwmon_sensor_types type,
|
||||
return 0;
|
||||
case hwmon_temp_fault:
|
||||
/*
|
||||
* The OPEN bit signals a fault. This is bit 0 of the temperature
|
||||
* register (low byte).
|
||||
* Any of OPEN or /PVLD bits indicate a hardware mulfunction
|
||||
* and the conversion result may be incorrect
|
||||
*/
|
||||
*val = tmp421->temp[channel] & 0x01;
|
||||
*val = !!(tmp421->temp[channel] & 0x03);
|
||||
return 0;
|
||||
default:
|
||||
return -EOPNOTSUPP;
|
||||
@ -176,9 +176,6 @@ static umode_t tmp421_is_visible(const void *data, enum hwmon_sensor_types type,
|
||||
{
|
||||
switch (attr) {
|
||||
case hwmon_temp_fault:
|
||||
if (channel == 0)
|
||||
return 0;
|
||||
return 0444;
|
||||
case hwmon_temp_input:
|
||||
return 0444;
|
||||
default:
|
||||
|