IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
In a certain disconnected state, a block device is present on
the system, can be opened, reports a valid size, reports the
correct device id (wwid), and matches a devices file entry.
But, reading the device can still fail. In this case,
device_ids_validate() was misinterpreting the read error as
the device having no data/label on it (and no PVID).
The validate function would then clear the PVID from the
devices file entry for the device, thinking that it was
fixing the devices file (making it consistent with the on disk
state.) Fix this by not attempting to check and correct a
devices file entry that cannot be read. Also make this case
explicit in the hints validation code (which was doing the
right thing but indirectly.)
event based autoactivation is now the only method that lvm
provides for autoactivation.
Setting lvm.conf event_activation=0 can still be used to disable
event based autoactivation commands, but doing so will no longer
enable static autoactivation.
Removes some incorrect and unnecessary checks for other entries
when adding a new devices. The removed checks and corrections were
mostly redundant with what is already done by device id matching.
Other checking is reworked so the warnings are a bit different.
When a device has a wwid (from sysfs), but lvm ignores the wwid,
e.g. because it contains an unreliable "QEMU" value, then lvm
falls back to using IDTYPE=devname (the device name) as the
device id. If the device name changes after reboot, then lvm
automatically searches for the PV on other devices to find the
new device name and correct system.devices. When searching for
the PV, lvm skips looking at devices that would use other id types,
e.g. if a device would use a wwid and not a devname, then it
skips checking it. However, it failed to account for the fact
that a device may have wwid that was ignored, in which case it
should be checked.
. error exit means that lvmdevices --update would make a change.
. remove check of PART field from --check because it isn't used.
. unlink searched_devnames file to ensure check|update will search
If the transient service remains after it's done, then
it prevents the same transient service from being run
again later if the PVs are detached and reattached
(although the behavior of a second autoactivation is not
well defined and may only work in limited cases.)
Description stolen from linux d/b/rbd.c L3:
rbd.c -- Export ceph rados objects as a Linux block device
16 partitions seem to make sense according to L90:
#define RBD_SINGLE_MAJOR_PART_SHIFT 4
Running *scan -vvvvvvdddddd yields
#filters/filter-type.c:28 /dev/rbd1p5: Skipping: Unrecognised LVM device type 252
#filters/filter-persistent.c:131 filter caching bad /dev/rbd1p5
right now, and adding
types = ["rbd", 252]
to /e/l/lvm.conf (with the matching "252 rbd" in /p/devices) works as a
per-machine fix:
rbd1 252:16 0 1T 1 disk
|-rbd1p1 252:17 0 243M 1 part
|-rbd1p2 252:18 0 1K 1 part
`-rbd1p5 252:21 0 1023.8G 1 part
`-dev01--vg-root 253:0 0 1023.8G 0 lvm
but rbd is supported by upstream so it'd be nice to have it work OOB
Fixes commit "pvscan: match device arg to filter symlink"
which failed to account for the fact that filter entries
are not just path names but include "a" or "r", etc.
The device_hint name in the metadata was meant to prevent
autoactivation from md components, but the name checks were
more general and would catch unnecessary cases.
This fixes an issue related to the optimization in
"pvscan: only add device args to dev cache"
If the devices file is not used, and the lvm.conf filter
accepts devices via symlink names, then those devices won't
be accepted by pvscan for autoactivation. To resolve this,
recognize when the filter contains symlinks and disable the
optimization. When the optimization is disabled, a full
dev_cache_scan is performed, and symlinks are associated
with the device names passed to pvscan. filter-regex
will accept a device if symlinks to that device are accepted.
Improve handling of md components that get through the
filter, like the previous improvement for multipath.
If md components get through the filter and trigger
duplicate PV code, then eliminate any devs entirely
that are not an md device.
If multipath component devices get through the filter and
cause lvm to see duplicate PVs, then check the wwid of the
devs and drop the component devices as if they had been
filtered. If a dm mpath device was found among the duplicates
then use that as the PV, otherwise do not use any of the
components as the PV.
"duplicate PVs" associated with multipath configs will no
longer stop commands from working.
Remove the searched_devnames file in a couple more places:
. When hints need refreshing it's possible that a missing
devices file entry could be found by searching devices
again.
. When a devices file entry devname is first found to be
incorrect, a new search for missing entries may be
useful.
When devnames are used as device ids and devnames change,
then new devices need to be located for the PVs. If the old
devname is now used by a filtered device, this was preventing
the code from searching for the new device, so the PV was
reported as missing.
If the optimized label scan fails (using online files),
then clear the device state prior to falling back to the
standard label_scan. This avoids printing output about
unexpected state.
Consistently create the pvs_lookup file for VGs with
more than one PV. Previously the file create would be
skipped if all the PVs happened to already be online.
That led to unpredicatable results in an uncommon case
(when the last PV to come online is the only PV with
metadata.)
Copy another optimization from pvscan -aay to vgchange -aay.
When using the optimized label scan for only one VG, acquire the
VG lock prior to the scan. This allows vg_read to then skip the
repeated label scan that normally happens after locking the vg.
Include the device name in the /run/lvm/pvs_online/pvid files.
Commands using the pvid file can use the devname to more quickly
find the correct device, vs finding the device using the
major:minor number. If the devname in the pvid file is missing
or incorrect, fall back to using the devno.
For completeness and consistency, adjust the behavior
for some variations of:
vgchange -aay --autoactivation event [vgname]
The current standard use is with a VG name arg, and the
command is only called when all pvs_online files exist.
This is the optimal case, in which only pvs_online devs
are read. This remains the same.
Clean up behaviors for some other unexpected uses of the
command:
. With no VG name arg, the command activates any VGs
that are complete according to pvs_online. If no
pvs_online files exist, it does nothing.
. If a VG name is used but no PVs online files exist for
the VG, or the PVs online files are incomplete, then
consider there could be a problem with the pvs_online
files, and fall back to a full label scan prior to
attempting the activation.
Part of the optimization to avoid a full dev_cache_scan requires
translating major:minor numbers to a device name. If this devno
translation fails, then fall back to doing a full dev_cache_scan
which is slower but certain to provide the info. This preserves
the most important part of the label scanning optimization in the
vgchange aay (avoiding dev_cache_scan is a relatively small part
of the optimized activation compared to label scanning.)
Port another optimization from pvscan -aay to vgchange -aay:
"pvscan: only add device args to dev cache"
This optimization avoids doing a full dev_cache_scan, and
instead populates dev-cache with only the devices in the
VG being activated.
This involves shifting the use of pvs_online files from
the hints interface up to the higher level label_scan
interface. This specialized label_scan is structured
around creating a list of devices from the pvs_online
files. Previously, a list of all devices was created
first, and then reduced based on the pvs_online files.
The initial step of listing all devices was slow when
thousands of devices are present on the system.
This optimization extends the previous optimization that
used pvs_online files to limit the devices that were
actually scanned (i.e. reading to identify the device):
"vgchange -aay: optimize device scan using pvs_online files"
Port the old pvscan -aay scanning optimization to vgchange -aay.
The optimization uses pvs_online files created by pvscan --cache
to derive a list of devices to use when activating a VG. This
allows autoactivation of a VG to avoid scanning all devices, and
only scan the devices used by the VG itself. The optimization is
applied internally using the device hints interface.
The new option "--autoactivation event" is given to pvscan and
vgchange commands that are called by event activation. This
informs the command that it is being used for event activation,
so that it can apply checks and optimizations that are specific
to event activation. Those include:
- skipping the command if lvm.conf event_activation=0
- checking that a VG is complete before activating it
- using pvs_online files to limit device scanning