1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
Commit Graph

7202 Commits

Author SHA1 Message Date
David Teigland
7c3eca833f lvresize: fix multiple mounts
which was mistaken as a mounted LV that had been renamed.
2023-06-16 12:11:51 -05:00
David Teigland
228a8e8c1f device_id: ignore leading and trailing spaces for sys_wwid and sys_serial
Leading and trailing underscores are also ignored to handle device ids
written by previous versions which replaced all spaces with underscores.
2023-06-15 15:17:14 -05:00
Zdenek Kabelac
fcf2057b38 cmd_enum: correct inclusion
Ensure we use generated header file for this build from -Iinclude.

Reported-by: Anton Lundin <glance@ac2.se>
2023-06-09 18:01:16 +02:00
David Teigland
74feebdab7 device_id: fix handling of non-PV with duplicate serial number
Fix in the code that matches devices to system.devices entries when
the devices have the same serial number.  A non-PV device in
system.devices has no pvid value, and the code was segfaulting
when checking the null pvid value.
2023-06-08 12:24:05 -05:00
David Teigland
0591131a53 lvreduce: simplify _lvseg_get_stripes integrity check
Simplify unnecessary loop to avoid coverity complaint.
2023-05-25 12:09:41 -05:00
David Teigland
4cdb178968 device_id: ignore trailing underscores in t10 wwid from devices file
In previous lvm versions, trailing spaces at the end of a t10 wwid would
be replaced with underscores, so the IDNAME string in system.devices
would look something like "t10.123_".  Current versions of lvm ignore
trailing spaces in a t10 wwid, so the IDNAME string used would be
"t10.123".  The different values would cause lvm to not recognize a
device in system.devices with the trailing _.  Fix this by ignoring
trailing underscores in the IDNAME string from system.devices.
2023-05-19 14:05:10 -05:00
David Teigland
24e4b6df11 tests: integrity-caching: ensure raid redundancy
The recent fix 05c2b10c5d ensures that raid LV images are not
using the same devices.  This was happening in the lvextend commands
used by this test, so fix the test to use more devices to ensue
redundancy.
2023-05-17 14:15:25 -05:00
David Teigland
fd6e113bba raidintegrity: allow snapshots 2023-05-11 11:02:52 -05:00
heinzm
05c2b10c5d Fix "multisegment RAID1, allocator uses one disk for both legs"
In case of e.g. 3 PVs, creating or extending a RaidLV causes SubLV
collocation thus putting segments of diffent rimage (and potentially
larger rmeta) SubLVs onto the same PV.  For redundant RaidLVs this'll
compromise redundancy.  Fix by detecting such bogus allocation on
lvcreate/lvextend and reject the request.
2023-05-10 18:35:21 +02:00
Zdenek Kabelac
cc7c41abbd cov: remove unneeded header file inclusion 2023-05-10 15:27:48 +02:00
Zdenek Kabelac
7b52a663a6 cov: validate dev_get_primary_dev result
Make sure primary_dev is defined when using it.
2023-05-10 15:27:48 +02:00
Zdenek Kabelac
534269d0fb vdo: document feature option 2023-05-06 20:38:57 +02:00
Zdenek Kabelac
f038fc3b17 cov: remove unused but set variables 2023-05-06 20:38:57 +02:00
Zdenek Kabelac
c451d7925d cleanup: correcting some log_print
Correcting to log_print_unless_silent(),
so -qq can do some work.
2023-05-06 20:38:49 +02:00
Zdenek Kabelac
39b2bd06b8 cov: some initializers 2023-05-06 19:22:05 +02:00
Zdenek Kabelac
4fd2f433ad cov: hide problem with 64bit time_t 2023-05-06 19:22:05 +02:00
Zdenek Kabelac
242bf56413 cov: validata top_lv
Add explicit pointer check is never NULL.
2023-05-06 19:22:05 +02:00
Zdenek Kabelac
662020c221 cov: simplier code
Avoid coverity to contruct some abstract scenarions of 'cft'
modification and simplify the code at the same time.
2023-05-06 19:22:05 +02:00
heinzm
d7e922480e Fix "lvconvert -m 0 will always take rimage_0 even if it is out-of-sync"
Bail out in case first rimage is out-of-sync.
Refresh first, i.e. "lvchange --resync $RaidLV",
then retry downgrade to linear after resynchronization.
2023-05-05 20:51:58 +02:00
David Teigland
368381fd40 lvreduce: make _lvseg_get_stripes handle integrity layer
lvreduce uses _lvseg_get_stripes() which was unable to get raid stripe
info with an integrity layer present.  This caused lvreduce on a
raid+integrity LV to fail prematurely when checking stripe parameters.
An unhelpful error message about stripe size would be printed.
2023-05-03 11:34:59 -05:00
David Teigland
6d262eaf64 lvmcache: fix valgrind error when dropping md duplicate
When lvmcache info is dropped because it's an md component,
then the lvmcache vginfo can also be dropped, but the list
iterator was still using the list head in vginfo, so break
from the loop earlier to avoid it.
2023-04-25 14:46:36 -05:00
Zdenek Kabelac
8947964f10 wipe_lv: use zeroing ioctl only for large sizes
There is no easy way to detect, whether device supports zeroing,
and kernel also zeroes device when it's not directly supported,
but with extra message:

operation not supported error, dev X, sector Y op 0x9:(WRITE_ZEROES)...

So to avoid generating such message with every 'lvcreate', use for
zeroing of upto 8K just standard write of zeroed page.
(maybe we can go with even larger sizes).
2023-04-25 00:12:31 +02:00
David Teigland
31cfcf7ce9 fix dev_name use in add_areas_line
This function was relying on dev_name() returning NULL
to indicate no device, but dev_name never returns NULL.
2023-04-24 15:49:00 -05:00
David Teigland
317071ec53 cache: fix snapshot of cache with cachevol
Creating a snapshot of a cache LV with a cachevol would fail
because cache_check was not being skipped.
2023-04-10 12:44:22 -05:00
David Teigland
8458ff9ad1 remove extra change from support 16KB page size 2023-04-07 15:57:28 -05:00
David Teigland
b443eac6ef support 16KB page size 2023-04-07 14:26:09 -05:00
Zdenek Kabelac
e8e6347ba3 vdo: use fixed size vdopool wrapper
Instead of using size of 'empty header' in vdopool use fixed size 4K
for a 'wrappeing' vdo-pool device.

This fixes the issue when user tried to activate vdo-pool after
a conversion from vdo managed device with 'vgchange -ay' - where
this command activated all LVs with 'vdo-pool' wrapping device as well,
but this converted pool uses  0-length header.

This 4k size should usually prevent other tools like 'blkid' recognize
such device as anything - so it shouldn't cause any problems with
duplicate indentification of devices.
2023-04-06 11:06:04 +02:00
Zdenek Kabelac
334117ee00 cleanup: rename function
Rename _thin_lv_has_device_id and use common function naming
with _lv_has_thin_device_id().
2023-04-06 11:06:04 +02:00
Zdenek Kabelac
1fb3e08033 cleanup: simplify 2023-04-06 11:06:04 +02:00
Zdenek Kabelac
51117b5793 integrity: hide creation of internal LVs
Creation of 'hidden' local LVs should be visible only in
verbose mode (-v) when creating a raid LV with integrity.
2023-04-06 11:06:04 +02:00
David Teigland
390ff5be2f raidintegrity: allow writecache and cache
Allow writecache|cache over raid+integrity LV.
2023-04-05 14:24:07 -05:00
David Teigland
69ea2e3f94 vg_read: keep MISSING_PV when device with no mda reappears
Remove old code that became incorrect at some point.
It's probably a fragment of an old condition that was left
behind because it wasn't understood.  We don't want to drop
the MISSING_PV flag just because the PV has no mda in use.
The device that was missing may have stale data, so the user
needs to decide if the device should be removed or restored.
2023-03-08 16:31:28 -06:00
David Teigland
1857eb9fe0 lvresize: fix check for mounted and renamed LV to handle spaces
Replace spaces with \040 in directory paths from getmntent (mtab).

The recent commit 5374a44c57 compares mount point directory paths
from /etc/mtab and /proc/mounts, in order to detect when a mounted
LV has been renamed.  The directory path comparison does not work
correctly when the path contains spaces because getmntent uses
ascii space chars and proc replaces spaces with \040.
2023-02-23 16:55:36 -06:00
Zdenek Kabelac
7bc5c8ac3d cov: avoid using strcpy
Coverity is complaining about unchecked strcpy here, which is
irelevant as we preallocate buffer to fit in copied string,
however we could actually reuse these size and use just memcpy().
So lets make some simple conversions.
2023-02-17 00:00:04 +01:00
David Teigland
bd05318ba2 pvscan: filter does not need to be checked for symlink names
With the recent use of DEVLINKS, there is no longer any real
point in checking the filter for symlink names.  Removing
this check should not change behavior with or without symlinks
in the filter.
2023-02-15 10:19:57 -06:00
Zdenek Kabelac
cf0dc9a13c filesystem: use PATH_MAX for linux paths 2023-02-12 23:56:29 +01:00
Zdenek Kabelac
631762d6db metadata-exported.h: correcting definition
Fixing minor mismatch between definition and declaration of
update_thin_pool_params().
2023-02-10 17:50:27 +01:00
Zdenek Kabelac
e3534d0f68 lvm: fix typos
Patch aec5e573af was fixing some
of typos only in generated file, but they need to be fixed in
the source files.
2023-02-10 17:50:27 +01:00
David Teigland
dc99f0def1 device_id: ignore quotes in device id
A t10 wwid string was found containing a " character
which breaks vg metadata parsing.  Ignore any quotation
marks in device id strings.
2023-02-06 12:24:18 -06:00
David Teigland
57ad78d436 vg_read: remove unused code for md components
This code was no longer used after ommit
87ee401eea
2023-02-02 16:15:13 -06:00
Zdenek Kabelac
f89c369a01 archive: update message
Better suggesting message as suggested by RHBZ 2123151.
2023-02-01 11:47:30 +01:00
David Teigland
6d14144d31 pvscan: recognize "pci" as a common symlink component in filters
In case the filter strings don't include "/dev/disk", and only
include "pci".
2023-01-31 15:30:35 -06:00
David Teigland
c9fdc828ff vgchange autoactivation: skip regex filter containing symlinks
"vgchange -aay --autoactivation event" is called by our udev rule.
When the udev rule runs, symlinks for devices may not all be created
yet.  If the regex filter contains symlinks, it won't work correctly.
This command uses devices that already passed through pvscan.  Since
pvscan applies the regex filter correctly, this command inherits the
filtering from pvscan and can skip the regex filter itself.

See the previous commit
"pvscan: use alternate device names from DEVLINKS to check filter"
2023-01-31 15:30:35 -06:00
David Teigland
17a3585cbb pvscan: use alternate device names from DEVLINKS to check filter
pvscan --cache <dev> is called by our udev rule at a time when all
the symlinks for <dev> may not be created yet (by other udev rules.)
The regex filter in lvm.conf may refer to <dev> using a symlink name
that hasn't yet been created, which would cause <dev> to not match
the filter regex.  The DEVLINKS env var, set by udev, contains all
the symlink names for <dev> that have been or will be created.
So, we add all these symlink names to dev->aliases, as if we had
found them in /dev.  This allows <dev> to be recognized by a regex
filter containing a symlink for <dev>.
2023-01-31 15:30:35 -06:00
David Teigland
d9f8acb65a lvresize: fail early if crypt device is missing
If extending an LV with crypto_LUKS on it, and the crypt device
is missing, then fail the command before extending the LV.
2023-01-30 17:12:11 -06:00
David Teigland
5374a44c57 lvresize: fail early if mounted LV was renamed
If a mounted LV is renamed, then fs resizing utilities will fail,
so detect this condition and fail the command before any changes
are made.
2023-01-26 14:02:20 -06:00
David Teigland
8adfcddc35 Revert "lvresize: enable crypt resizing with --force"
It looks like force was not being used to enable crypt resize,
but rather to force an inconsistency between LV and crypt
sizes, so this is either not needed or force in this case
should have some other meaning.

This reverts commit ed808a9b54.
2023-01-25 10:10:57 -06:00
David Teigland
ed808a9b54 lvresize: enable crypt resizing with --force
Update previous commit
  "lvresize: only resize crypt when fs resize is enabled"
to enable crypt resizing when --force is set and --resizefs
is not set.  This is because it's been allowed in the past
and people have used it, but it's not a good idea.
2023-01-20 12:04:55 -06:00
David Teigland
3bb5576528 lvresize: only resize crypt when fs resize is enabled
There were a couple of cases where lvresize, without --fs resize,
was resizing the crypt layer above the LV.  Resizing the crypt
layer should only be done when fs resizing is enabled (even if the
fs is already small enough due to being independently reduced.)

Also, check the size of the crypt device to see if it's already
been reduced independently, and skip the cryptsetup resize if
it's not needed.
2023-01-19 11:52:14 -06:00
Zdenek Kabelac
c20f01a0cb vdo: resize requires active vdopool volume
ATM kernel VDO target does not handle resize of inactive VDO LVs
so prevent users corrupting such LVs and require active such LVs.
2023-01-16 12:37:40 +01:00