IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Code adds better support for monitoring of thin pool devices.
update_pool_lv uses DMEVENTD_MONITOR_IGNORE to not manipulate with monitoring.
vgchange & lvchange are checking real thin pool device for existance
as we are using _tpool real device and visible LV pool device might not
be even active (_tpool is activated implicitely for any thin volume).
monitor_dev_for_events is another _lv_postorder like code it might be worth
to think about reusing it here - for now update the code to properly
monitory thin volume deps.
For unmonitoring add extra code to check the usage of thin pool - in case it's in use
unmonitoring of thin volume is skipped.
Make the teardown really usable - it will try down to remove all the left
devices even from previous test runs
(the only missing piece is probably proper mdadm teardown)
Add few more local vars
Try to setup PATH and LD_LIBRARY_PATH just once.
Try shorter sleeps.
Actually restart was failing for different reason - so pass in proper
location of dmeventd for restart from lvm command and avoid using
the one from /sbin location.
Update pv create test with "" around path.
There are kernel drivers (smblk) which set '-1' as their device major number.
This number is listed in /proc/devices then - but the kernel itself is using
just 12 bits - thus device is accessible via 4095 - there is posted patch
for 3.4 to fix this behavior (0 for auto allocation was mean to be used).
However to still allow using such devices with older kernels add some code
to use same behavior - so cut 12 bits from the major number from /proc/devices.
For now use log_warn() - maybe the severity of the message could be lowered
to just verbose level.
Indent
Shell improvements - use internal function for checks
Use PVs in "" (LV and VG cannot have spaces)
Several test very starting 'dmeventd' without annoucing
it via prepade_dmeventd.
Fix some of test actually.
Indent
Better shell usage
Function simplification
More usage of 'get' functions
Don't use valgrind tracing for check and get function (faster)
Update shell debugging (PS4, better stacktrace)
Support paths with spaces
Export SCRIPTNAME for external usage
Watch for dmeventd unexpectedly started during test
Indent
Add valgrind support:
env LVM_TEST_VALGRIND={0123} (the higher level, more commands tested)
env LVM_TEST_CLVMD=1 runs clvmd within valgrind.
env VALGRIND script name executed for each lvm command (def. is valg).
Smarted teardown - should minimize occurence of left dev entries
(using dmsetup remove -f only as last resort)
sort removed devices by open count before actual removal
Use "" around string that may contain spaces.
Set log/verbose and activation/retry_deactivation to defined value.
Remove debug.log after successful lvm command (easier to check output).
Currently we could not test special prefixes in our test suite.
As teardown will not find such device and basicaly busyloops here,
as at cannot remove such names.
This patch adds possibity to use:
vgcreate V_$vg1 $dev
Note: you still need to use $PREFIX somewhere in the name.
(And of course, it's really bad idea to use $PREFIX (=LVMTEST)
for normally used LVs)
The only purpose of this patch is to allow testing cluster with
special vg names that begins with V_ , P_....
Fix propagation of -e option - pass it via internal shell variable.
Fix parsing of /proc/mounts files (don't check for substrings).
as reported by O.Mangold with suggested patch:
https://www.redhat.com/archives/linux-lvm/2012-February/msg00030.html
Properly pass arguments with spaces ("$@")
Add validation for YES and EXTOFF variable content.
When down-converting a RAID1 device, it is the last device that is extracted
and removed when the user does not specify a particular device. However,
when a device is specified (and it is not the last), the device is removed and
the remaining sub-LVs are "shifted down" to fill the hole. This cause problems
when resuming the LV because if the shifted devices were resumed (and thus
renamed) before the sub-LV being extracted, there would be a name conflict.
The solution is to resume the extracted sub-LVs first so that they can be
properly renamed preventing a possible conflict.
This addresses bug 801967.
Update a way we handle option passing - so we now support path and options
with space inside.
Fix dm name usage for thin pools with '-' in name.
Use new lvm.conf option thin_check_options to pass in options as string array.
LISTEN_PID and LISTEN_FDS environment variables are defined only during systemd
"start" action. But we still need to know whether we're activated during
"reload" action as well - we use the reload action to call "dmeventd -R"/"lvmetad -R"
for statefull daemon restart. We can't use normal "restart" as that is simply
composed of "stop" and "start" and we would lose any state the daemon has.
Save some relocation entries and use directly char[].
Since we do not need yes more then 127 partitions per device, use just int8_t.
Move lvm_type_filter_destroy into local static function.
Support timestamping with harness - using VERBOSE=2
Fix also logging in several situation
(i.e. continue logging multiple test in VERBOSE mode,
do not coredump with empty output).
Never return unfinished toolcontext - since error path is hit on
various stages of initialization we cannot leave it partially uninitialized,
since we would need to spread many more test across the code for config_valid.
Instead return NULL and properly release udev library resources as well.