IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Include info in the temp file to confirm that it should be used.
The temp file is meant to suppress repeated, identical searches
for the same PVIDs on the same set of devices. Write to the file
a count and hash of the missing PVIDs and a count and hash of the
devices to search. A subsequent command will ignore and remove
the temp file if any of these values differ. We don't want to
suppress a search if a change has occured, and a missing PV could
be found by scanning devices.
Problematic scenario:
. the device for a PV has no wwid, so it's identified in system.devices
with IDTYPE=devname IDNAME=/dev/foo
. user adds/enables a wwid for the device
. on reboot, the device name changes, e.g. now /dev/bar
. the code that searches for the new device name includes an
optimization to skip looking on devs that have a wwid, on
the basis that a device with a wwid won't have IDTYPE=devname
. this optimization causes lvm to not look for the PV on /dev/bar
since that device now has a wwid, so the PV is not found
. the optimization is enabled by search_for_devnames="auto"
. change the default to search_for_devnames="all" which does not
use the problematic optimization
- add new comparison between old and new entries, and use this
as the basis for new dedicated output for check and update
- add new --refresh option to search for missing PVIDs on all
devices, and possibly update the device ID
- internally, only use the term "refresh" for cases where a
new device ID may be found and assigned for a missing PVID
Incorrectly matching a dev to a devname id (due to changing devnames)
before matching the dev to a proper device id, can result in the
dev not being matched to the real id.
With commit d7e922480e
lvconvert -m may fail if we try to remove 1st. leg that
is out-of-sync while other leg is in-sync.
Hot fix allows to proceed with such down conversion.
Signed-off-by: Heinz Mauelshagen <heinzm@redhat.com>
Fixes commit 63b469c160
"device_id: fix hints with device ids"
It's not correct for internal filtering to be a factor
in validating the set of devs that are the basis for hints.
Instead, look for inconsistencies between a hint entry and
the corresponding devices file entry.
Apply the same logic for 'lvreduce' which exists for newer
systems (compiled with HAVE_BLKID_SUBLKS_FSINFO)
also for older systems for one very common practical case where
the active LV does not have any blkid known signature/filesystem.
New variant recognized this situation and allowed to proceed
without requesting a prompt, while the older variant always
requested confirmation prompt.
With this patch command now works equily for both variants
for 'active LV' without signature and allows to reduce LV
without prompting.
Before checking seg_type of the first area, check there is
some existing area.
Since we now support error and zero segtypes, these do not have
any PV area present.
Fix some interactions between device IDs and hints. Hints
may limit the scanned devices which should not always trigger
a search for the PVs that were intentionally not scanned.
Hints should also be invalidated if they contain a device
that's become excluded by an internal filter such as the
device_id filter.
Search for a PV on other devices if it's a devname entry
and the name doesn't exist on the system. This restores
code that should not have been removed in commit 1901a47df
"device_id: fix conditions for device_ids_refresh"
Fix commit 847f1dd99c
"device_id: rewrite validation of devname entries"
which began calling device_ids_refresh() in cases where it
was unnecessary, leading to extra PV searches and warnings.
Specifically, a command like "lvs <vg>" would use the hints
file to scan only devices for the named VG. This means that
scanning other PVs would be skipped, and device IDs of those
PVs could not be validated because there are no PVID values
to verify. This missing info would cause messages about
the missing info, and would cause device_ids_refresh to
search for the PVs that had been intentionally skipped.
This is mainly useful in internal testing - but keep sysfs dir also
passed to filter.
Also drop use of static variable within sysfs filter and base whole
config at creation time.
If the system changes, locate PVs that appear on different devices,
and update the device IDs in the devices file. A system change is
detected by saving the DMI product_uuid or hostname in the devices
file, and comparing it to the current system value. If a root PV
is restored or copied to a new system with different devices, then
the product_uuid or hostname should change, and trigger lvm to
locate PVIDs from system.devices on new devices.
Reuse existing report/headings config setting to make it possible to
change the type of headings to display:
0 - no headings
1 - column name abbreviations (default and original functionality)
2 - full column names (column names are equal to exact names that
-o|--options also accepts to set report output)
Also, add '--headings none|abbrev|full|0|1|2' command line option
so we are able to select the heading type for each LVM reporting
command directly.
While create new LV for pool volume, use name from 'pool_metadata%d' naming
sequence. This LV is later on renamed to pool_t/cmeta, but if there
is any error in the middle, we may evenutally leave some 'volume',
With this name it can be slightly more obvious how it got there,
but also when we handle _pmspare name - we get slightly more predictible
name used there for it.
However for a standard usage this commit shall no visible impact as the
name is used temporarily just for cleaning LV.
Set the lock_args string in addition to doing initialization.
lvconvert calls lockd_init_lv_args() directly, skipping
the normal lockd_init_lv() which usually sets lock_args.
We incorrectly marked pv_major and pv_minor fields as being of string
type, even though the values were already correctly handled as integers
internally. This confused -S|--select that tried to compare string
values instead of integers.
Reported here: https://github.com/lvmteam/lvm2/issues/122
Replace the use of internal /dev/mapper names with the use of
public LV names /dev/vg/lv for use with repair tools.
For this make the activation of _pmspare LV to be handled as
a component activation with public name.
Metadata is already atomatically activated this way (as readonly).
So if there is any 'error' happening, we leave public LVs in
system.
Last commit c38b668fc3 was pushed
with type 'scanf' instead of 'sscanf' needed for buffer reading.
Interestingly this caused scanning from 'stdin' descriptor and
thus failures in lvm shell usage.
The code in init_log_file relies on the process name (COMM) to not
contain whitespaces. This change fixes it by looking up the right-most
parenthesis to safely jump past COMM.
For more context see:
https://www.openwall.com/lists/oss-security/2022/12/21/6
Code is only used with testing, so it should have no impact on regular
users.
Reported-by: Hugues Evrard <hevrard@google.com>
mm
With 3596558861 it's been introduced
a more fine grained description.
However 'disabled' might be actually more confusing then empty field,
so keep only the info about 'not enabled'aka dmevend is not allowed
to monitor LV which otherwise could be monitored.
Update pool conversion function to handle also conversion of
thick LV to thin LV by moving thick LV into thin pool data LV
and creating fully provissioned thin LV on top of this volume.
Reworking existing conversion to use insert_layer_for_lv co
the uuid is now kept with thin-pool - this should however not
really matter as we are doing full deactivation & activation cycle.
With conversion to thin LV user can use same set of arguments
to set chunk-size.
TODO: add some smart code to decide best values for chunks sizes.
For proper functionality of insert_layer_for_lv we need to
move more bits to layerd LV.
Add some missing new types and correct usage of caller,
so the new LV type is set after the movement.
Validate cache origin in front of the prompt.
Also add some rules to command description file.
TODO:
more validation needed also for lvcreate,
more complex rules with "OR" seems to be needed.
Avoid activation when going to skip zeroing of 'error' segtype
(so it's not erroring out).
Also skip zeroing for 'zero' segtype LV (already being zero).
When lvm2 calculates the maximal usable COW size and crops the user
requested size to this value, don't return the error result from
the 'lvextend' operation.
We already apply the same logic when resizing thin-pool beyond
the supported maximal size.
FIXME: The return code error logic here is somewhat fuzzy.
This vdo parameter existed in the early stage of integration of vdo into lvm2,
but later it's been removed from vdoformat tool - so actually if
there would be any non-zero value it would cause error on lvcreate.
Option was not stored on disk in lvm2 metadata.
Remove this vdo parameter from lvm2 sources.
(Although this vdo parameter will be still accepted on cmdline through
--vdosettings option, but it will be ignored.)
Fix in the code that matches devices to system.devices entries when
the devices have the same serial number. A non-PV device in
system.devices has no pvid value, and the code was segfaulting
when checking the null pvid value.
In previous lvm versions, trailing spaces at the end of a t10 wwid would
be replaced with underscores, so the IDNAME string in system.devices
would look something like "t10.123_". Current versions of lvm ignore
trailing spaces in a t10 wwid, so the IDNAME string used would be
"t10.123". The different values would cause lvm to not recognize a
device in system.devices with the trailing _. Fix this by ignoring
trailing underscores in the IDNAME string from system.devices.
The recent fix 05c2b10c5d ensures that raid LV images are not
using the same devices. This was happening in the lvextend commands
used by this test, so fix the test to use more devices to ensue
redundancy.
In case of e.g. 3 PVs, creating or extending a RaidLV causes SubLV
collocation thus putting segments of diffent rimage (and potentially
larger rmeta) SubLVs onto the same PV. For redundant RaidLVs this'll
compromise redundancy. Fix by detecting such bogus allocation on
lvcreate/lvextend and reject the request.