IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
We use adjusted_mirror_region_size() in two different contexts.
Either on command line -
here we do want to inform user about reduction of size.
Or in pvmove activation context -
here we should only use 'verbose' info.
When requesting to reload an LV imrove this API to
automatically reload its lock holding LV as in cluster
only top-level LVs are addressable with lock.
When vg_ondisk is NULL we do not need to search
through the whole VG to find out the same LV.
NOTE: as of now - VG locking is not enabled as some code parts
are breaking memory locking rules (lvm2app).
Once we enforce VG locking for read-only commands the effect
will be much better for larger VGs.
Move common code for reading and processing
of --persistent arguments for lvcreate and lvchange
into lvmcmdline.
Reuse validate_major_minor() routine for validation.
Don't blindly activate LVs after change in cluster
and instead only local reactivation is supported.
(we have now many limited targets now).
Dropping 'sigint_caught()' handling, since
prompt() is resolving this case itself.
If we want to support conversion of VG to clustered type,
we currently need to relock active LV to get proper DLM lock.
So add extra loop after change of VG clustered attribute
to exlusively activate all active top level LVs.
When doing change -cy -> -cn we should validate LVs are not
active on other cluster nodes - we could be sure about this only
when with local exclusive activation - for other types
we require user to deactivate volumes first.
As a workaround for this limitation there is always
locking_type = 0 which amongs other skip the detection
of active LVs.
FIXME:
clvmd should handle looks for cluster locking type all the time.
Failure to copy the 'feature_flags' lvconvert_param to the matching
lv_segment field meant that when a user specified the cachemode argument,
the request was not honored.
While we could probably reacquire some type of lock when
going from non-clustered to clustered vg, we don't have any
single road back to drop the lock and keep LV active.
For now keep it safe and prohibit conversion when LV
is active in the VG.
Try to enforce consistent macro usage along these lines:
lv_is_mirror - mirror that uses the original dm-raid1 implementation
(segment type "mirror")
lv_is_mirror_type - also includes internal mirror image and log LVs
lv_is_raid - raid volume that uses the new dm-raid implementation
(segment type "raid")
lv_is_raid_type - also includes internal raid image / log / metadata LVs
lv_is_mirrored - LV is mirrored using either kernel implementation
(excludes non-mirror modes like raid5 etc.)
lv_is_pvmove - internal pvmove volume
Use lv_is_* macros throughout the code base, introducing
lv_is_pvmove, lv_is_locked, lv_is_converting and lv_is_merging.
lv_is_mirror_type no longer includes pvmove.
Fix rename operation for snapshot (cow) LV.
Only the snapshot's origin has the lock and by mistake suspend
and resume has been called for the snapshot LV.
This further made volumes unusable in cluster.
So instead of suspend and resuming list of LVs,
we need to just suspend and resume origin.
As the sequence write/suspend/commit/resume
is widely used in lvm2 code base - move it to
new lv_update_and_reload function.
Fixing problem, when user sets volume_list and excludes thin pools
from activation. In this case pool return 'success' for skipped activation.
We need to really check the volume it is actually active to properly
to remove queued pool messages. Otherwise the lvm2 and kernel
metadata started to go async since lvm2 believed, messages were submitted.
Add also better check for threshold when create a new thin volume.
In this case we require local activation of thin pool so we are able
to check pool fullness.
The 'lv_type' field name was a bit misleading. Better one is 'lv_role'
since this fields describes what's the actual use of the LV currently -
its 'role'.
Sort out the lvresize calculation code to handle size changes
specified as physical extents as well as logical extents
and to process mirror resizing and raid extensions correctly.
The 'approx alloc' option was masking the underlying problem.
When testing conversion sanity, we checked lv->status & MIRRORED
which encompasses both old mirrors and raid1 mirrors. But we need to
ban only the old mirrors here hence allow raid1 mirrors.
The maximum stripe size is equal to the volume group PE size. If that
size falls below the STRIPE_SIZE_MIN, the creation of RAID 4/5/6 volumes
becomes impossible. (The kernel will fail to load a RAID 4/5/6 mapping
table with a stripe size less than STRIPE_SIZE_MIN.) So, we report an
error if it is attempted.
This is very rare because reducing the PE size down that far limits the
size of the PV below that of modern devices.
The lv_layout and lv_type fields together help with LV identification.
We can do basic identification using the lv_attr field which provides
very condensed view. In contrast to that, the new lv_layout and lv_type
fields provide more detialed information on exact layout and type used
for LVs.
For top-level LVs which are pure types not combined with any
other LV types, the lv_layout value is equal to lv_type value.
For non-top-level LVs which may be combined with other types,
the lv_layout describes the underlying layout used, while the
lv_type describes the use/type/usage of the LV.
These two new fields are both string lists so selection (-S/--select)
criteria can be defined using the list operators easily:
[] for strict matching
{} for subset matching.
For example, let's consider this:
$ lvs -a -o name,vg_name,lv_attr,layout,type
LV VG Attr Layout Type
[lvol1_pmspare] vg ewi------- linear metadata,pool,spare
pool vg twi-a-tz-- pool,thin pool,thin
[pool_tdata] vg rwi-aor--- level10,raid data,pool,thin
[pool_tdata_rimage_0] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_1] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_2] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_3] vg iwi-aor--- linear image,raid
[pool_tdata_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_1] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_2] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_3] vg ewi-aor--- linear metadata,raid
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
[pool_tmeta_rimage_0] vg iwi-aor--- linear image,raid
[pool_tmeta_rimage_1] vg iwi-aor--- linear image,raid
[pool_tmeta_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tmeta_rmeta_1] vg ewi-aor--- linear metadata,raid
thin_snap1 vg Vwi---tz-k thin snapshot,thin
thin_snap2 vg Vwi---tz-k thin snapshot,thin
thin_vol1 vg Vwi-a-tz-- thin thin
thin_vol2 vg Vwi-a-tz-- thin multiple,origin,thin
Which is a situation with thin pool, thin volumes and thin snapshots.
We can see internal 'pool_tdata' volume that makes up thin pool has
actually a level10 raid layout and the internal 'pool_tmeta' has
level1 raid layout. Also, we can see that 'thin_snap1' and 'thin_snap2'
are both thin snapshots while 'thin_vol1' is thin origin (having
multiple snapshots).
Such reporting scheme provides much better base for selection criteria
in addition to providing more detailed information, for example:
$ lvs -a -o name,vg_name,lv_attr,layout,type -S 'type=metadata'
LV VG Attr Layout Type
[lvol1_pmspare] vg ewi------- linear metadata,pool,spare
[pool_tdata_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_1] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_2] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_3] vg ewi-aor--- linear metadata,raid
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
[pool_tmeta_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tmeta_rmeta_1] vg ewi-aor--- linear metadata,raid
(selected all LVs which are related to metadata of any type)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'type={metadata,thin}'
LV VG Attr Layout Type
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs which hold metadata related to thin)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'type={thin,snapshot}'
LV VG Attr Layout Type
thin_snap1 vg Vwi---tz-k thin snapshot,thin
thin_snap2 vg Vwi---tz-k thin snapshot,thin
(selected all LVs which are thin snapshots)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'layout=raid'
LV VG Attr Layout Type
[pool_tdata] vg rwi-aor--- level10,raid data,pool,thin
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs with raid layout, any raid layout)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'layout={raid,level1}'
LV VG Attr Layout Type
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs with raid level1 layout exactly)
And so on...
_pvcreate_check() has two missing requirements:
After refreshing filters there must be a rescan.
(Otherwise the persistent filter may remain empty.)
After wiping a signature, the filters must be refreshed.
(A device that was previously excluded by the filter due to
its signature might now need to be included.)
If several devices are added at once, the repeated scanning isn't
strictly needed, but we can address that later as part of the command
processing restructuring (by grouping the devices).
Replace the new pvcreate code added by commit
54685c20fc "filters: fix regression caused
by commit e80884cd080cad7e10be4588e3493b9000649426"
with this change to _pvcreate_check().
The filter refresh problem dates back to commit
acb4b5e4de "Fix pvcreate device check."
If using persistent filter and we're refreshing filters (just like we
do for pvcreate now after commit 54685c20fc),
we can't rely on getting the primary device of the partition from the cache
as such device could be already filtered by persistent filter and we get
a device cache lookup failure for such device.
For example:
$ lvm dumpconfig --type diff
devices {
obtain_device_list_from_udev=0
}
$lsblk /dev/sda
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:0 0 128M 0 disk
`-sda1 8:1 0 127M 0 part
$cat /etc/lvm/cache/.cache | grep sda
"/dev/sda1",
$pvcreate /dev/sda1
dev_is_mpath: failed to get device for 8:1
Physical volume "/dev/sda1" successfully created
The problematic part of the code called dev_cache_get_by_devt
to get the device for the device number supplied. Then the code
used dev_name(dev) to get the name which is then used in check
whether there's any mpath on top of this dev...
This patch uses sysfs to get the base name for the partition
instead, hence avoiding the device cache which is a correct
approach here.
The message "Cannot deactivate remotely exclusive device locally." makes
sense only for clustered LV. If the LV is non-clustered, then it's
always exclusive by definition and if it's already deactivated, this
message pops up inappropriately as those two conditions are met.
So issue the message only if the conditions are met AND we have clustered VG.
With cmirrord, we can do pvmove of clustered mirror. The code checking
suitability of LVs on the PV being moved issued a message if a mirror
LV was found and the VG was clustered. However, the actual pvmove did
work correctly.
The top-level mirror LV is actually skipped in the code since it's
always layered on top of internal LVs making up the mirror LV and for pvmove
we consider these internal devices only as they're actually layered on
top of concrete PVs then. But we don't need to issue any message here
about skipping the top-level mirror LV - it's misleading here.
Commit e80884cd08 tried to dump filters
for them to be reevaluated when creating a PV to avoid overwriting
any existing signature that may have been created after last
scan/filtering.
However, we need to call refresh_filters instead of
persistent_filter->dump since dump requires proper rescannig to fill
up the persistent filter again. However, this is true only for pvcreate
but not for vgcreate with PV creation where the scanning happens before
this PV creation and hence the next rescan (if not full scan), does not
fill the persistent filter.
Also, move refresh_filters so that it's called sooner and only for
pvcreate, vgcreate already calls lvmcache_label_scan(cmd, 2) which
then calls refresh_filters itself, so no need to reevaluate this again.
This caused the persistent filter (/etc/lvm/cache/.cache file) to be
wrong and contain only the PV just being processed with
vgcreate <vg_name> <pv_name_to_create>.
This regression caused other block devices to be filtered out in case
the vgcreate with PV creation was used and then the persistent filter
is used by any other LVM command afterwards.
Make lvresize -l+%FREE support approximate allocation.
Move existing "Reducing/Extending' message to verbose level
and change it to say 'up to' if approximate allocation is being used.
Replace it with a new message that gives the actual old and new size or
says 'unchanged'.
This is addendum to commit 2e82a070f3
which fixed these spurious messages that appeared after commit
651d5093ed ("avoid pv_read in
find_pv_by_name").
There was one more "not found" message issued in case the device
could not be found in device cache (commit 2e82a07 fixed this only
for PV lookup itself). But if we "allow_unformatted" for
find_pv_by_name, we should not issue this message even in case
the device can't be found in dev cache as we just need to know
whether there's a PV or not for the code to decide on next steps
and we don't want to issue any messages if either device itself
is not found or PV is not found.
For example, when we were creating a new PV (and so allow_unformatted = 1)
and the device had a signature on it which caused it to be filtered
by device filter (e.g. MD signature if md filtering is enabled),
or it was part of some other subsystem (e.g. multipath), this message
was issued on find_pv_by_name call which was misleading.
Also, remove misleading "stack" call in case find_pv_by_name
returns NULL in pvcreate_check - any error state is reported
later by pvcreate_check code so no need to "stack" here.
There's one more and proper check to issue "not found" message if
the device can't be found in device cache within pvcreate_check fn
so this situation is still covered properly later in the code.
Before this patch (/dev/sda contains MD signature and is therefore filtered):
$ pvcreate /dev/sda
Physical volume /dev/sda not found
WARNING: linux_raid_member signature detected on /dev/sda at offset 4096. Wipe it? [y/n]:
With this patch applied:
$ pvcreate /dev/sda
WARNING: linux_raid_member signature detected on /dev/sda at offset 4096. Wipe it? [y/n]:
Non-existent devices are still caught properly:
$ pvcreate /dev/sdx
Device /dev/sdx not found (or ignored by filtering).
2.02.106 added suffixes to some LV uuids in the kernel.
If any of these LVs is activated with 2.02.105 or earlier,
and then a later version is used, the LVs appear invisible and
activation commands fail.
The code now has to check the kernel for both old and new uuids.
Fix get_pool_params to only read params.
Add poolmetadataspare option to get_pool_params.
Move all profile code into update_pool_params.
Move recalculate code into pool_manip.c
Major update of lvconvert code to handle cache and thin.
related targets.
Code tries to unify handling of cache and thin pools.
Better supports lvm2 syntax:
lvconvert --type cache --cachepool vg/pool vg/cache
lvconvert --type thin --thinpool vg/pool vg/extorg
lvconvert --type cache-pool vg/pool
lvconvert --type thin-pool vg/pool
as well as:
lvconvert --cache --cachepool vg/pool vg/cache
lvconvert --thin --thinpool vg/pool vg/extorg
lvconvert --cachepool vg/pool
lvconvert --thinpool vg/pool
While catching much more command line errors.
(Yet couple paths still needs more tests)
Detects as much cmdline errors prior opening VG.
Uses single lvconvert_name_params to convert LV names.
Detects as much incompatibilies in VG prior prompting.
Uses single prompt to confirm whole conversion.
TODO: still the code needs fixes...
Since the type passed LV is changed and content of data detroyed,
query user with prompt to confirm this operation.
Also add a proper wiping of header.
Using '--yes' will skip this prompt:
lvconvert -s --yes vg/lv vg/lvcow
Currently, we have two modes of activation, an unnamed nominal mode
(which I will refer to as "complete") and "partial" mode. The
"complete" mode requires that a volume group be 'complete' - that
is, no missing PVs. If there are any missing PVs, no affected LVs
are allowed to activate - even RAID LVs which might be able to
tolerate a failure. The "partial" mode allows anything to be
activated (or at least attempted). If a non-redundant LV is
missing a portion of its addressable space due to a device failure,
it will be replaced with an error target. RAID LVs will either
activate or fail to activate depending on how badly their
redundancy is compromised.
This patch adds a third option, "degraded" mode. This mode can
be selected via the '--activationmode {complete|degraded|partial}'
option to lvchange/vgchange. It can also be set in lvm.conf.
The "degraded" activation mode allows RAID LVs with a sufficient
level of redundancy to activate (e.g. a RAID5 LV with one device
failure, a RAID6 with two device failures, or RAID1 with n-1
failures). RAID LVs with too many device failures are not allowed
to activate - nor are any non-redundant LVs that may have been
affected. This patch also makes the "degraded" mode the default
activation mode.
The degraded activation mode does not yet work in a cluster. A
new cluster lock flag (LCK_DEGRADED_MODE) will need to be created
to make that work. Currently, there is limited space for this
extra flag and I am looking for possible solutions. One possible
solution is to usurp LCK_CONVERT, as it is not used. When the
locking_type is 3, the degraded mode flag simply gets dropped and
the old ("complete") behavior is exhibited.
lv_active_{locally,remotely,exclusively} display the original
"lv_active" field in a more separate way so that we can create
selection criteria in a binary-based form (yes/no).
Support remove of thin volumes With --force --force
when thin pools is damaged.
This way it's possible to remove thin pool with
unrepairable metadata without requiring to
manually edit lvm2 metadata.
lvremove -ff vg/pool
removes all thin volumes and pool even when
thin pool cannot be activated (to accept
removal of thin volumes in kernel metadata)
Use builddir not srcdir with make pofile.
Append 'incfile:' lines to %.d files to handle newly-missing dependencies
without 'make clean' after a file is moved or deleted.
Use suffixes for easier detection of private volumes.
This commit makes older volume UUIDs incompatible and
it most probably needs machine reboot after upgrade.
When creating pool's metadata - create initial LV for clearing with some
generic name and after the volume is create & cleared - rename it to
reserved name '_tmeta/_cmeta'.
We should not expose 'reserved' names for public LVs.
When repairing RAID LVs that have multiple PVs per image, allow
replacement images to be reallocated from the PVs that have not
failed in the image if there is sufficient space.
This allows for scenarios where a 2-way RAID1 is spread across 4 PVs,
where each image lives on two PVs but doesn't use the entire space
on any of them. If one PV fails and there is sufficient space on the
remaining PV in the image, the image can be reallocated on just the
remaining PV.
I've changed build_parallel_areas_from_lv to take a new parameter
that allows the caller to build parallel areas by LV vs by segment.
Previously, the function created a list of parallel areas for each
segment in the given LV. When it came time for allocation, the
parallel areas were honored on a segment basis. This was problematic
for RAID because any new RAID image must avoid being placed on any
PVs used by other images in the RAID. For example, if we have a
linear LV that has half its space on one PV and half on another, we
do not want an up-convert to use either of those PVs. It should
especially not wind up with the following, where the first portion
of one LV is paired up with the second portion of the other:
------PV1------- ------PV2-------
[ 2of2 image_1 ] [ 1of2 image_1 ]
[ 1of2 image_0 ] [ 2of2 image_0 ]
---------------- ----------------
Previously, it was possible for this to happen. The change makes
it so that the returned parallel areas list contains one "super"
segment (seg_pvs) with a list of all the PVs from every actual
segment in the given LV and covering the entire logical extent range.
This change allows RAID conversions to function properly when there
are existing images that contain multiple segments that span more
than one PV.
...to avoid using cached value (persistent filter) and therefore
not noticing any change made after last scan/filtering - the state
of the device may have changed, for example new signatures added.
$ lvm dumpconfig --type diff
allocation {
use_blkid_wiping=0
}
devices {
obtain_device_list_from_udev=0
}
$ cat /etc/lvm/cache/.cache | grep sda
$ vgscan
Reading all physical volumes. This may take a while...
Found volume group "fedora" using metadata type lvm2
$ cat /etc/lvm/cache/.cache | grep sda
"/dev/sda",
$ parted /dev/sda mklabel gpt
Information: You may need to update /etc/fstab.
$ parted /dev/sda print
Model: QEMU QEMU HARDDISK (scsi)
Disk /dev/sda: 134MB
Sector size (logical/physical): 512B/512B
Partition Table: gpt
Disk Flags:
Number Start End Size File system Name Flags
$ cat /etc/lvm/cache/.cache | grep sda
"/dev/sda",
====
Before this patch:
$ pvcreate /dev/sda
Physical volume "/dev/sda" successfully created
With this patch applied:
$ pvcreate /dev/sda
Physical volume /dev/sda not found
Device /dev/sda not found (or ignored by filtering).
Take a local file lock to prevent concurrent activation/deactivation of LVs.
Thin/cache types and an extension for cluster support are excluded for
now.
'lvchange -ay $lv' and 'lvchange -an $lv' should no longer cause trouble
if issued concurrently: the new lock should make sure they
activate/deactivate $lv one-after-the-other, instead of overlapping.
(If anyone wants to experiment with the cluster patch, please get in touch.)
pvmove can be used to move single LVs by name or multiple LVs that
lie within the specified PV range (e.g. /dev/sdb1:0-1000). When
moving more than one LV, the portions of those LVs that are in the
range to be moved are added to a new temporary pvmove LV. The LVs
then point to the range in the pvmove LV, rather than the PV
range.
Example 1:
We have two LVs in this example. After they were
created, the first LV was grown, yeilding two segments
in LV1. So, there are two LVs with a total of three
segments.
Before pvmove:
--------- --------- ---------
| LV1s0 | | LV2s0 | | LV1s1 |
--------- --------- ---------
| | |
-------------------------------------
PV | 000 - 255 | 256 - 511 | 512 - 767 |
-------------------------------------
After pvmove inserts the temporary pvmove LV:
--------- --------- ---------
| LV1s0 | | LV2s0 | | LV1s1 |
--------- --------- ---------
| | |
-------------------------------------
pvmove0 | seg 0 | seg 1 | seg 2 |
-------------------------------------
| | |
-------------------------------------
PV | 000 - 255 | 256 - 511 | 512 - 767 |
-------------------------------------
Each of the affected LV segments now point to a
range of blocks in the pvmove LV, which purposefully
corresponds to the segments moved from the original
LVs into the temporary pvmove LV.
The current implementation goes on from here to mirror the temporary
pvmove LV by segment. Further, as the pvmove LV is activated, only
one of its segments is actually mirrored (i.e. "moving") at a time.
The rest are either complete or not addressed yet. If the pvmove
is aborted, those segments that are completed will remain on the
destination and those that are not yet addressed or in the process
of moving will stay on the source PV. Thus, it is possible to have
a partially completed move - some LVs (or certain segments of LVs)
on the source PV and some on the destination.
Example 2:
What 'example 1' might look if it was half-way
through the move.
--------- --------- ---------
| LV1s0 | | LV2s0 | | LV1s1 |
--------- --------- ---------
| | |
-------------------------------------
pvmove0 | seg 0 | seg 1 | seg 2 |
-------------------------------------
| | |
| -------------------------
source PV | | 256 - 511 | 512 - 767 |
| -------------------------
| ||
-------------------------
dest PV | 000 - 255 | 256 - 511 |
-------------------------
This update allows the user to specify that they would like the
pvmove mirror created "by LV" rather than "by segment". That is,
the pvmove LV becomes an image in an encapsulating mirror along
with the allocated copy image.
Example 3:
A pvmove that is performed "by LV" rather than "by segment".
--------- ---------
| LV1s0 | | LV2s0 |
--------- ---------
| |
-------------------------
pvmove0 | * LV-level mirror * |
-------------------------
/ \
pvmove_mimage0 / pvmove_mimage1
------------------------- -------------------------
| seg 0 | seg 1 | | seg 0 | seg 1 |
------------------------- -------------------------
| | | |
------------------------- -------------------------
| 000 - 255 | 256 - 511 | | 000 - 255 | 256 - 511 |
------------------------- -------------------------
source PV dest PV
The thing that differentiates a pvmove done in this way and a simple
"up-convert" from linear to mirror is the preservation of the
distinct segments. A normal up-convert would simply allocate the
necessary space with no regard for segment boundaries. The pvmove
operation must preserve the segments because they are the critical
boundary between the segments of the LVs being moved. So, when the
pvmove copy image is allocated, all corresponding segments must be
allocated. The code that merges ajoining segments that are part of
the same LV when the metadata is written must also be avoided in
this case. This method of mirroring is unique enough to warrant its
own definitional macro, MIRROR_BY_SEGMENTED_LV. This joins the two
existing macros: MIRROR_BY_SEG (for original pvmove) and MIRROR_BY_LV
(for user created mirrors).
The advantages of performing pvmove in this way is that all of the
LVs affected can be moved together. It is an all-or-nothing approach
that leaves all LV segments on the source PV if the move is aborted.
Additionally, a mirror log can be used (in the future) to provide tracking
of progress; allowing the copy to continue where it left off in the event
there is a deactivation.
Let's use the size of origin as the real base for percenta calculation,
and 'silenly' add needed metadata space for snapshot.
So now command 'lvcreate -s -l100%ORIGIN vg/lv' should always create a
snapshot to handle full device overwrite.
When creating a cache LV with a RAID origin, we need to ensure that
the sub-LVs of that origin properly change their names to include
the "_corig" extention of the top-level LV. We do this by first
performing a 'lv_rename_update' before making the call to
'insert_layer_for_lv'.
The thin-generic.profile contains settings for thin/thin pool volumes
suitable for generic environment/use containing default settings.
This allows users to change the global lvm.conf settings at will
and still keep the original settings for volumes that have this
thin profile assigned already.
Internal reporting function cannot handle NULL reporting value,
so ensure there is at least dummy label.
So move dummy_lable from tools/reporter.c and use it for all
report_object() calls in lib/report/report.c.
(Fixes RHBZ 1108394)
Simlify lvm_report_object initialization.
Enable 'retry' deactivation also in 'cleanup' phase.
It shouldn't be mostly needed - however udev now produces
more and more completelny non-synchronizable device opens,
so even for orphan devices we can't easily predict where
udevd opens devices.
So it's more preferable here to log error about device being open
and retry clean, but let the command proceed.
LVM has restricter character set that is allowed for VG-LV names
and the dm names constructed do not contain any blacklisted characters
that would require name mangling.
Also, when any other device-mapper device is scanned that could
possibly contain such blacklisted characters, we reference the
device by its major:minor instead of dm name (e.g. _device_is_usable fn).
The "default.profile" name was misleading. It's actually a helper
*template* that can be used for copying and further editing to create
a new profile.
Also, we have separate command and metadata profiles now so the templates
are separated as well - we can't mix profile settings from one group with
another - such profile is rejected by lvm tools.
Warn user before converting volume to different type.
WARNING: Converting vg/lvol0 logical volume to pool's meta/data volume.
THIS WILL DESTROY CONTENT OF LOGICAL VOLUME (filesystem etc.)
Since the content of volume is lost we have to query user to confirm
such operation. If user is 100% sure, he may use '--yes' to avoid prompts.
The dumpconfig now understands --commandprofile/--profile/--metadataprofile
The --commandprofile and --profile functionality is almost the same
with only one difference and that is that the --profile is just used
for dumping the content, it's not applied for the command itself
(while the --commandprofile profile is applied like it is done for
any other LVM command).
We also allow --metadataprofile for dumpconfig - dumpconfig *does not*
touch VG/LV and metadata in any way so it's OK to use it here (just for
dumping the content, checking the profile validity etc.).
The validity of the profile can be checked with:
dumpconfig --commandprofile/--profile/--metadataprofile --validate
...depending on the profile type.
Also, mention --config in the dumpconfig help string so users know
that dumpconfig handles this too (it did even before, but it was not
documented in the help string).
- When defining configuration source, the code now uses separate
CONFIG_PROFILE_COMMAND and CONFIG_PROFILE_METADATA markers
(before, it was just CONFIG_PROFILE that did not make the
difference between the two). This helps when checking the
configuration if it contains correct set of options which
are all in either command-profilable or metadata-profilable
group without mixing these groups together - so it's a firm
distinction. The "command profile" can't contain
"metadata profile" and vice versa! This is strictly checked
and if the settings are mixed, such profile is rejected and
it's not used. So in the end, the CONFIG_PROFILE_COMMAND
set of options and CONFIG_PROFILE_METADATA are mutually exclusive
sets.
- Marking configuration with one or the other marker will also
determine the way these configuration sources are positioned
in the configuration cascade which is now:
CONFIG_STRING -> CONFIG_PROFILE_COMMAND -> CONFIG_PROFILE_METADATA -> CONFIG_FILE/CONFIG_MERGED_FILES
- Marking configuration with one or the other marker will also make
it possible to issue a command context refresh (will be probably
a part of a future patch) if needed for settings in global profile
set. For settings in metadata profile set this is impossible since
we can't refresh cmd context in the middle of reading VG/LV metadata
and for each VG/LV separately because each VG/LV can have a different
metadata profile assinged and it's not possible to change these
settings at this level.
- When command profile is incorrect, it's rejected *and also* the
command exits immediately - the profile *must* be correct for the
command that was run with a profile to be executed. Before this
patch, when the profile was found incorrect, there was just the
warning message and the command continued without profile applied.
But it's more correct to exit immediately in this case.
- When metadata profile is incorrect, we reject it during command
runtime (as we know the profile name from metadata and not early
from command line as it is in case of command profiles) and we
*do continue* with the command as we're in the middle of operation.
Also, the metadata profile is applied directly and on the fly on
find_config_tree_* fn call and even if the metadata profile is
found incorrect, we still need to return the non-profiled value
as found in the other configuration provided or default value.
To exit immediately even in this case, we'd need to refactor
existing find_config_tree_* fns so they can return error. Currently,
these fns return only config values (which end up with default
values in the end if the config is not found).
- To check the profile validity before use to be sure it's correct,
one can use :
lvm dumpconfig --commandprofile/--metadataprofile ProfileName --validate
(the --commandprofile/--metadataprofile for dumpconfig will come
as part of the subsequent patch)
- This patch also adds a reference to --commandprofile and
--metadataprofile in the cmd help string (which was missing before
for the --profile for some commands). We do not mention --profile
now as people should use --commandprofile or --metadataprofile
directly. However, the --profile is still supported for backward
compatibility and it's translated as:
--profile == --metadataprofile for lvcreate, vgcreate, lvchange and vgchange
(as these commands are able to attach profile to metadata)
--profile == --commandprofile for all the other commands
(--metadataprofile is not allowed there as it makes no sense)
- This patch also contains some cleanups to make the code handling
the profiles more readable...
The dumpconfig reuses existing config_def_check results in case
the check is done during general lvm command context initialization
(when enabled by config/checks=1) so dumpconfig does not need to run
the same check again during its execution, hence saving some time.
However, we don't check for differences from defaults during general
lvm command initialization as it's useless at that time. It makes
sense only in case when such a check is directly requested (like in
the case of lvm dumpconfig --type diff). We need to take care that
the reused information was already produced with this "diff" checking
before and if not, we need to force the check so the check status also
gathers the new "diff" info now.
Also, do not do diff checking for any other dumpconfig command that
is run after dumpconfig --type diff.
When cmd refresh is called, we need to move any already loaded profiles
to profiles_to_load list which will cause their reload on subsequent
use. In addition to that, we need to take into account any change
in config/profile configuration setting on cmd context refresh
since this setting could be overriden with --config.
Also, when running commands in the shell, we need to remove the
global profile used from the configuration cascade so the profile
is not incorrectly reused next time when the --profile option is
not specified anymore for the next command in the shell.
This bug only affected profile specified by --profile cmd line
arg, not profiles referenced from LVM metadata.
Since decisions in the silent mode may not be always obvious,
print skipped prompt with answer 'n'.
Also document '-qq' behaviour (single -q only shuts
logging, while -qq sets silent mode).
Share DM_REPORT_FIELD_RESERVED_NAME_{HELP,HELP_ALT} between libdm and
any libdm user to handle reserved field names, in this case the virtual
field name to show help instead of failing on unrecognized field.
The libdm user also needs to check the field name so it can fire
proper code in this case (cleanup, exit etc.).
Support upto 3 levels os nesting signal blocking.
As of today - code blocks signals immediatelly when it opens
VG in read-write mode - this however makes current prompt usage
then partially unusable since user may not 'break' command
during prompt (something most user would expect).
Until a better fix for prompting is implemented, put in support
for signal nesting - thus when prompt enables signal acceptance,
make it possible to really break command at this point.
When quering for dmeventd monitoring status, check first
if lvm2 is configured to monitor to avoid unwanted start
of dmeventd process for answering monitoring status.
When showing ACTIVE status for snapshot's origin,
avoid testing all its snapshot - it's not useful
to tell user origin is inactivate, while it's clearly
available and running - just one of its snapshot leg
is invalid...
Relocate info from thin pool and thin volume segments
to proper code section for segments.
Add discards and thin count status info.
Info is shown with 'lvdisplay --maps' (like for other segments).
For percentage display we need -tpool - so check for layered
device presence here instead of plain pool device.
Also update 'info' - so when pool is 'available' we
display open count for -tpool device instead of mostly
irrelevant pool.
TODO: Maybe we should actually display this open info always?
(even when just -tpool is available, but pool is not)
Emphesize virtual extents for virtual LVs and for
those use 'Virtual extents' instead of 'Logical extents',
so it's immeditatelly visible, which extents do have
straighforward physical backend.
While the 'raid1/10' segment types were being handled inadvertently
by '_move_mirrors()', the parity RAIDs were not being properly checked
to ensure that the user had specified all necessary PVs when moving
them. Thus, internal errors were being triggered when only part of
a RAID LV was moved to the new VG. I've added a new function,
'_move_raid()', which properly checks over any affected RAID LVs and
ensures that all the necessary PVs are being moved.
ignore_suspended_devices=0 is already used in lvm.conf we distribute,
but it was still "1" in the code (so it was used when lvm.conf value
was not defined). It should be "0" too.
Config variables that are processed during setup prior to calling into
particular tools must not be accessed directly afterwards in case the
values already got overridden.
_process_config() already used the tests I'm removing here to call
lvmetad_set_active() and set up lvmetad_used().
This should be the preferred way of configuring lvm2 for udev/systemd
since otherwise one can end up with the processes run from udev (the
pvscan we run for lvmetad update on events) to be killed prematurely
and this can end up with LVM volumes not activated in the end.
This is sort of info we always ask people to retrieve when
inspecting problems in systemd environment so let's have this
as part of lvmdump directly.
The -s option does not need to be bound to systemd only. We could
add support for initscripts or any other system-wide/service tracking
info that can help us with debugging problems.
Set A_POSITIONAL_FILL if the array of areas is being filled
positionally (with a slot corresponding to each 'leg') rather
than sequentially (with all suitable areas found, to be sorted
and selected from).
Prior adding new reply to the list, check
if the reply thread is not already finished.
In that case discard adding message
(which would otherwise be leaked).
Use mutex to access localsock values, so check
num_replies when the thread is not yet finished.
Check for threadid prior the mutex taking
(though this check is probably not really needed)
Added complexity with extra reply mutex is not worth the troubles.
The only place which may slightly benefit from this mutex is timeout
and since this is rather error case - let's convert it to
localsock.mutex and keep it simple.
Move the pthread mutex and condition creation and destroy
to correct place right after client memory is allocatedd
or is going to be released.
In the original place it's been in race with lvm thread
which could have still unlock mutex while it's been already
destroyed.
When TEST_MODE flag is passed around the cluster,
it's been use in thread unprotected way, so it may have
influenced behaviour of other running parallel lvm commands
(activation/deactivation/suspend/resume).
Fix it by set/query function only under lvm mutex.
For hold_un/lock function calls check lock_flags bits directly.
When pvmove0 is finished, it replaces temporarily pvmove0
with error segment, however in this case, pvmove0 remains
unremovable in case pvmove --abort is interrupted in this
moment - since it's not a pvmove anymore and normal
lvremove can't be used to remove LOCKED lv.
There were two bugs before when using pvcreate --restorefile together
with data alignment and its offset specified:
- the --dataalignment was always ignored due to missing braces in the
code when validating the divisibility of supplied --dataalignment
argument with pe_start which we're just restoring:
if (pp->rp.pe_start % pp->data_alignment)
log_warn("WARNING: Ignoring data alignment %" PRIu64
" incompatible with --restorefile value (%"
PRIu64").", pp->data_alignment, pp->rp.pe_start);
pp->data_alignment = 0
The pp->data_alignment should be zeroed only if the pe_start is not
divisible with data_alignment.
- the check for compatibility of restored pe_start was incorrect too
since it did not properly count with the dataalignmentoffset that
could be supplied together with dataalignment
The proper formula is:
X * dataalignment + dataalignmentoffset == pe_start
So it should be:
if ((pp->rp.pe_start % pp->data_alignment) != pp->data_alignment_offset) {
...ignore supplied dataalignment and dataalignment offset...
}
This test for LV name restriction check name of device is below 128
chars (which is enforced by dm target).
Thus it should not count with device name.
(Though the test for PATH_MAX size should be probably also added,
but this is runtime test, since theoretically devpath might differ in cluster)
It's unclear why we should prohibit use of -v output.
So reenable (like with other 'display' tools)
But -c -m is really unsupported - return invalid cmd.
Sort order for -C|--columns as with other options,
and use short capital name as the first (as with other options).
Also drop multiple reference for pvs/lvs/vgs, since now
the text for -C is really close to referrence of lvm anyway.
Drop unused passed cmd pointer from function.
TODO:
We have two similar functions (though not identical)
lv_manip.c: for_each_sub_lv()
metadata.c: _lv_each_dependency()
They seem to not always match - we should probably convert
to use only a single function.
Use proper vgmem memory pool for allocation of LV name in the vg
and check if new renamed LV is a valid name.
TODO: validation should really use also VG name, othewise we are not
able to tell "vgname-lvname" will be valid.
Commit 1a832398a7 moved
some code from _pvchange_single() to main pvchange() and
introduced exit code regression as return codes have not
been properly changed, thus pvchange command exited
with '0' exit code, even though it has reported error.
Also there is a missing vg unlock in error path.
Fix it by counting the total number of expected calls before
checking for pvname and also unlock and relase vg when
pv is not found.
For a quick overview of config when debugging and to quickly check
which values are different from defaults and which are not defined
in the config and for which defaults are used.
When lvm2 command works with clvmd and uses locking in wrong way,
it may 'leak' certain file descriptors in opened (incorrect) state.
dev_cache_exit then destroys memory pool of cached devices, while
_open_devices list in dev-io.c was still referencing them if they
were still opened.
Patch properly calls _close() function to 'self-heal' from this
invalid state, but it will report internal error (so execution
with abort_on_internal_error causes immediate death). On the
normal 'execution', error is only reported, but memory state is
corrected, and linked list is not referencing devices from
released mempool.
For crash see: https://bugzilla.redhat.com/show_bug.cgi?id=1073886
Smallest supported size for swap device is 40KB, however current
test skipped devices smaller then 4096 sectors (2MB).
Since page is in bytes, convert it to sectors before comparing
with device size (in sectors).
pvscan --uuid was broken since it was using only 128 char buffers
without checking any write size, so any longer device path leads to
crash.
Also ansure format is properly aligned into columns with this option.
The PV size is displayed in sectors, not kilobytes
for 'pvdisplay -c'
Signed-off-by: Thomas Fehr <fehr@suse.de>
Acked-by: Hannes Reinecke <hare@suse.de>
Instead of sending repeatedly LOCAL_SYNC commands to clvmds
like 'lvs', rememeber the last sent commmand, and if there was no other
clvmd command, drop this redundant SYNC call message.
The problem has started with commit:
56cab8cc03
This introduced correct synchronisation of name, when user requests to know
open_count (needs to wait for udev), however it is also executed for
read-only cases like 'lvs' command.
For now implement very simple solution, which is only monitoring
outgoing clvmd command, and when sequence of LOCAL sync names are
recognized, they are skipped automatically.
TODO:
Future solution might move this variable info 'cmd_context' and
use 'needs_sync' flag also i.e. in file locking code.
When the backup is disabled, avoid testing backup presence.
This only leads to errors being logged in debug trace and the missing
backup can't be fixed, since it's disabled.
Check whether lvm dumpconfig --mergedconfig is used only
with --type current (where we're merging current config and
the config supplied on command line). With other types
the config was merged, but it was thrown away since we're
generating other type of config anyway. This lead to a memleak.
Error out if --mergedconfig is used with anything else than
--type current (or without specifying --type in which case
the --type current is used by default).
Do not allow conversion of too small LV into a COW snapshot device.
Without this patch snapshot target is generating these kernel
messages before creation fails:
attempt to access beyond end of device
dm-9: rw=16, want=8, limit=2
attempt to access beyond end of device
...
device-mapper: table: 253:11: snapshot: Failed to read snapshot metadata
device-mapper: ioctl: error adding target to table
device-mapper: reload ioctl on failed: Input/output error
Usage of origin as a snapshot 'COW' volume is unsupported.
Without this test lvm2 is able to generate this ugly internal error message.
To test this:
lvcreate -L1 -n lv1 vg
lvcreate -L1 -n lv2 -s vg/lv1
lvcreate -L1 -n lv3 vg
lvconvert -s vg/lv3 vg/lv1
Internal error: LVs (5) != visible LVs (1) + snapshots (1) + internal LVs (0) in VG vg
Users can create several profiles for how the tools report
the output very easily and then just use
<lvm reporting command> --profile <report_profile_name>
This prevents numerous VG refreshes on each "pvscan --cache -aay" call
if the VG is found complete. We need to issue the refresh only if the PV:
- is new
- was gone before and now it reappears (device "unplug/plug back" scenario)
- the metadata has changed
Let's do this the other way round - this makes more logic than commit b995f06.
So let's allow empty values for global/thin_disabled_features where
such an empty value now means "none of this features are disabled".