IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
When the device is not a PV print
"No PV found on device ..."
instead of
"Failed to read lvm info for ... PVID ."
an earlier check had been added with a different
message for the same condition.
error reading dev and no pvid on dev were both
returning 0. make it easier for callers to
know which, if they care.
return 1 if the device could be read, regardless
of whether a pvid was found or not.
set has_pvid=1 if a pvid is found and 0 if no
pvid is found.
While we heavily try to spot arrays that are not yet in-sync,
some kernels tends to block our lvm2 command in kernel,
while we resume these smaller raid arrays even for 5 seconds.
But since the result is not really wrong - report these
check failures only as TEST WARNING.
Missed -l option in man page, although users should prefer
lvresize -r when the also want to do a volume management,
as there they can specify i.e. extents for allocation.
Also mention dm-crypt support in command description.
If the 'act' has been already processed by add_client_result()
it could have been possibly release - so avoid accessin 'act->'
afterward and go for next item directly.
This case happens when i.e. we convert LV to another type,
when we change existing LV into a different type - so change
to debug level and avoid confusing users with message about
Device path not match.
We may eventually enhnace caching code to drop cached info
after taking lock and reading VG.
With commit 0b18c25d93 there
was introduced 'zalloc()' for allocation of outdates pvs,
but no matching 'free()' is present.
Switch to use cmd mempool instead of adding free() code into
several places.
If a cmd def implies an LV type without --type
in the required options, then include the implied
type in the cmd def as AUTOTYPE: <type>
instead of including the redundant --type foo
in the OO list of options.
Including an implied --type in the OO list would
often cause multiple cmd defs to potentially be
identical when options were used, and a user
command could match more than one cmd def.
The AUTOTYPE values are listed in man page and
help output as
[ --type foo (implied) ]
If a user command includes --type, it will usually
match a cmd def with --type in the required options.
But, if the user command matches a cmd def with
AUTOTYPE, then the specifed --type and AUTOTYPE must
match.
The man-generator program has a new --check
option that compares cmd defs to find any cmd defs
that are equivalent with the use of options,
and should have their options adjusted.
Compares cmd defs based on two principles for avoiding repeated
commands (where a given command could match more than one cmd def):
. a cmd def should be a unique combination of required
option args and position args
. avoid adding optional options to a cmd def that if
used would make the command match a different cmd def
FIXME: record when repeated cmd defs are found so we can
avoid reporting them twice, e.g. once for A vs B and
second time for B vs A.
Correcting some usage of Bold and Italics (files).
Adding some missing SEE ALSO.
Fixing missed replaceable paths that are configurable.
Be careful about .P in .TP sections - need to use .sp for space line.
Use .UR/.UE for URL references.
Use #DEFAULT_SYS_DIR# replaceable string for devicesfile
so the man pages installation respects configured settings.
Update some missing lvm.conf(5) references.
Add missing VG into description of thin pool creation command.
Remove one duplicated thin-pool creation command.
Remove options --discards and --errorwhenfull from the list when the command describes
only creation of a thin volume - as these options do apply for thin-pool.
Also use here more correct name OO_LVCONVERT_THINPOOL instead of OO_LVCONVERT_THIN.
Reorder extra options for cache & thin-pool before common pool options.
Order consistenly --stripes and --stripesize after --extents option
so the options related to pools are better together.
Remove invalid snapshot creation description - since this case is
handled through our configurable spare volume creation.
Add some missing optional --type parameters for few command instancies.