IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
With 3596558861 it's been introduced
a more fine grained description.
However 'disabled' might be actually more confusing then empty field,
so keep only the info about 'not enabled'aka dmevend is not allowed
to monitor LV which otherwise could be monitored.
Update pool conversion function to handle also conversion of
thick LV to thin LV by moving thick LV into thin pool data LV
and creating fully provissioned thin LV on top of this volume.
Reworking existing conversion to use insert_layer_for_lv co
the uuid is now kept with thin-pool - this should however not
really matter as we are doing full deactivation & activation cycle.
With conversion to thin LV user can use same set of arguments
to set chunk-size.
TODO: add some smart code to decide best values for chunks sizes.
For proper functionality of insert_layer_for_lv we need to
move more bits to layerd LV.
Add some missing new types and correct usage of caller,
so the new LV type is set after the movement.
Validate cache origin in front of the prompt.
Also add some rules to command description file.
TODO:
more validation needed also for lvcreate,
more complex rules with "OR" seems to be needed.
Enable support to cache thin/error/zero virtual targets.
Use can now select whether he want to cache whole thin-pool,
or an individual thin volume out of whole thin-pool.
Support using zero and error LVs as data volume for
cachepool is possibly useful for benchmarking, not much
can be expected from such setup.
Avoid activation when going to skip zeroing of 'error' segtype
(so it's not erroring out).
Also skip zeroing for 'zero' segtype LV (already being zero).
When lvm2 calculates the maximal usable COW size and crops the user
requested size to this value, don't return the error result from
the 'lvextend' operation.
We already apply the same logic when resizing thin-pool beyond
the supported maximal size.
FIXME: The return code error logic here is somewhat fuzzy.
Output from vdo manager may actually indent output with spaces,
so trim leading and ending space.
Also add support for verbosity flag for vdo conversion tool.
This vdo parameter existed in the early stage of integration of vdo into lvm2,
but later it's been removed from vdoformat tool - so actually if
there would be any non-zero value it would cause error on lvcreate.
Option was not stored on disk in lvm2 metadata.
Remove this vdo parameter from lvm2 sources.
(Although this vdo parameter will be still accepted on cmdline through
--vdosettings option, but it will be ignored.)
Fix the testing logic.
With raid5 device the layout of files on a filesystem does not define
which leg will actually contain the block we try to damage.
So test will now figure out which device has damaged block.
Use 'check' functionality and also drop unneeded random write as we
now can identify easily in other way.
Compilation may configure it's own /etc path so ensure the test
has a defined location for access to this dir during testing.
Also prepare machine_id filei (with the use of uuidgen tool)
for the test.
Ensure the volume after conversion has the properly aligned size to the
volume group extent size. This would be visible when using virtual size,
that cannot be divided by extent size.
Before the user had to manually adjust the size after conversion to get
access to all data stored on VDO volume.