IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Fixes segfault when 'pvs' encounters two different PVs sharing the same
uuid but one an orphan, the other in a VG.
If VG_GLOBAL is held, there seems no point in doing a full scan more
than once.
If undesirable side-effects show up, we can try restricting this to
VG_GLOBAL READ locks. The original code dates back to 2.02.40.
When pvscan --cache --major --minor command is issued from
udev REMOVE event, it basically resulted into a whole device
scan since the device was missing. So avoid such scan
and first check via /sysfs (when available) if such device actually
exists.
When available use nanosecond stat info.
If commands are running closely enough after config update,
the .cache file from persistent filter could have been ignored.
This happens sometimes during i.e. synthetic test suite run.
There is no reason to support persistent major/minor numbers
for pool volumes - it's only meant to be supported for filesystems
(since i.e. nfs may need to keep volume on a persistent device node.)
Support for pools is now explicitely disabled and documented.
Metadata areas which are marked as ignored should not be scanned
and read during pvscan --cache. Otherwise, this can cause lvmetad
to cache out-of-date metadata in case other PVs with fresh metadata
are missing by chance.
Make this to work like in non-lvmetad case where the behaviour would
be the same as if the PV was orphan (in case we have no other PVs
with valid non-ignored metadata areas).
Simplify the function usage and clean up parameter parsing.
There were 2 significant changes made in the test itself
(they passed before because of incorrect shell string handling)
-pvs_sel 'tags="pv_tag1"' "$dev1 $dev2"
+sel pv 'tags="pv_tag1"' "$dev1" "$dev6"
-lvs_sel '(lv_name=vol1 || lv_name=vol2) || vg_tags=vg_tag1' "vol1 vol2
abc orig snap"
+sel lv '(lv_name=vol1 || lv_name=vol2) || vg_tags=vg_tag1' vol1 vol2
orig snap xyz
The iscsi-shutdown.service is the one responsible for logging out
iscsi sessions so blk-availability.service (running the blkdeactivate
script) should be run before that on shutdown (so we need to use
After=iscsi-shutdown.service because "After" relates to starting
the service and the opposite order is automatically applied on
stopping the service at shutdown).
Avoid busy-looping on CPU while reading socket pipe
and always call read only when select tells there is
something for read.
Change the batch output to old nicer output.
When lvm1 PVs are visible, and lvmetad is used, and the foreign
option was included in the reporting command, the reporting
command would fail after the 'pvscan all devs' function saw
the lvm1 PVs. There is no reason the command should fail
because of the lvm1 PVs; they should just be ignored.
Return 1 on success in pvdisplay_short() and lvdisplay_full()
so commands like vgdisplay are not printinig stracktraces
on successful passes.
As the results of fail/success have been internally ignored for those
calls, it had no other visible side effect - command's return value was
still 0 (success).
Detect an lvm1 system id by looking at the WRITE_LOCKED flag.
Don't copy this lvm1 system id into vg->system_id so that the
restrictions associated with the new system id are not applied
to the old VG with the inherited lvm1 system id.
The string reported by uname -n may include characters
that lvm omits from the system id (like parens, as seen
on a test machine.) Check against the final system id
string that lvm uses.
Since we take a lock inside vg_lock_newname() and we do a full
detection of presence of vgname inside all scanned labels,
there is no point to do this for second time to be sure
there is no such vg.
The only side-effect of such call would be a full validation of
some already exising VG metadata - but that's not the task for
vgcreate when create a new VG.
This call noticable reduces number of scans during 'vgcreate'.
Use similar logic as with text_vg_import_fd() and avoid repeated
parsing of same mda and its config tree for vgname_from_mda().
Remember last parsed vgname, vgid and creation_host in labeller
structure and if the metadata have the same size and checksum,
return this stored info.
TODO: The reuse of labeller struct is not ideal, some lvmcache API for
this functionality would be nicer.
When reading VG mda from multiple PVs - do all the validation only
when mda is seen for the first time and when mda checksum and length
is same just return already existing VG pointer.
(i.e. using 300PVs for a VG would lead to create and destroy 300 config trees....)