IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
With 3596558861 it's been introduced
a more fine grained description.
However 'disabled' might be actually more confusing then empty field,
so keep only the info about 'not enabled'aka dmevend is not allowed
to monitor LV which otherwise could be monitored.
Update pool conversion function to handle also conversion of
thick LV to thin LV by moving thick LV into thin pool data LV
and creating fully provissioned thin LV on top of this volume.
Reworking existing conversion to use insert_layer_for_lv co
the uuid is now kept with thin-pool - this should however not
really matter as we are doing full deactivation & activation cycle.
With conversion to thin LV user can use same set of arguments
to set chunk-size.
TODO: add some smart code to decide best values for chunks sizes.
For proper functionality of insert_layer_for_lv we need to
move more bits to layerd LV.
Add some missing new types and correct usage of caller,
so the new LV type is set after the movement.
Validate cache origin in front of the prompt.
Also add some rules to command description file.
TODO:
more validation needed also for lvcreate,
more complex rules with "OR" seems to be needed.
Avoid activation when going to skip zeroing of 'error' segtype
(so it's not erroring out).
Also skip zeroing for 'zero' segtype LV (already being zero).
When lvm2 calculates the maximal usable COW size and crops the user
requested size to this value, don't return the error result from
the 'lvextend' operation.
We already apply the same logic when resizing thin-pool beyond
the supported maximal size.
FIXME: The return code error logic here is somewhat fuzzy.
This vdo parameter existed in the early stage of integration of vdo into lvm2,
but later it's been removed from vdoformat tool - so actually if
there would be any non-zero value it would cause error on lvcreate.
Option was not stored on disk in lvm2 metadata.
Remove this vdo parameter from lvm2 sources.
(Although this vdo parameter will be still accepted on cmdline through
--vdosettings option, but it will be ignored.)
Fix in the code that matches devices to system.devices entries when
the devices have the same serial number. A non-PV device in
system.devices has no pvid value, and the code was segfaulting
when checking the null pvid value.
In previous lvm versions, trailing spaces at the end of a t10 wwid would
be replaced with underscores, so the IDNAME string in system.devices
would look something like "t10.123_". Current versions of lvm ignore
trailing spaces in a t10 wwid, so the IDNAME string used would be
"t10.123". The different values would cause lvm to not recognize a
device in system.devices with the trailing _. Fix this by ignoring
trailing underscores in the IDNAME string from system.devices.
The recent fix 05c2b10c5d ensures that raid LV images are not
using the same devices. This was happening in the lvextend commands
used by this test, so fix the test to use more devices to ensue
redundancy.
In case of e.g. 3 PVs, creating or extending a RaidLV causes SubLV
collocation thus putting segments of diffent rimage (and potentially
larger rmeta) SubLVs onto the same PV. For redundant RaidLVs this'll
compromise redundancy. Fix by detecting such bogus allocation on
lvcreate/lvextend and reject the request.
lvreduce uses _lvseg_get_stripes() which was unable to get raid stripe
info with an integrity layer present. This caused lvreduce on a
raid+integrity LV to fail prematurely when checking stripe parameters.
An unhelpful error message about stripe size would be printed.
When lvmcache info is dropped because it's an md component,
then the lvmcache vginfo can also be dropped, but the list
iterator was still using the list head in vginfo, so break
from the loop earlier to avoid it.
There is no easy way to detect, whether device supports zeroing,
and kernel also zeroes device when it's not directly supported,
but with extra message:
operation not supported error, dev X, sector Y op 0x9:(WRITE_ZEROES)...
So to avoid generating such message with every 'lvcreate', use for
zeroing of upto 8K just standard write of zeroed page.
(maybe we can go with even larger sizes).
Instead of using size of 'empty header' in vdopool use fixed size 4K
for a 'wrappeing' vdo-pool device.
This fixes the issue when user tried to activate vdo-pool after
a conversion from vdo managed device with 'vgchange -ay' - where
this command activated all LVs with 'vdo-pool' wrapping device as well,
but this converted pool uses 0-length header.
This 4k size should usually prevent other tools like 'blkid' recognize
such device as anything - so it shouldn't cause any problems with
duplicate indentification of devices.
Remove old code that became incorrect at some point.
It's probably a fragment of an old condition that was left
behind because it wasn't understood. We don't want to drop
the MISSING_PV flag just because the PV has no mda in use.
The device that was missing may have stale data, so the user
needs to decide if the device should be removed or restored.