IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Current allocation limitation requires to fit metadata/log LV on
a single PV. This is usually not a big problem, but since
thin-pool and cache-pool is using this for allocating extents
for their metadata LVs it might be eventually causing errors
where the remaining free spaces for large metadata size is spread
over several PV.
When passing 'pvmove --name arg' try to automatically move
all associated dependencies with given LV.
i.e. 'pvmove --name thinpool vg vgnew'
moves all thins and data and metadata LV into a new VG vgnew.
Use update_pool_metadata_min_max() which is shared with
thin-pool metadata min-max updating.
Gives improved messages when converting volumes to metadata.
There is not much point to let allocate more then this size
even when i.e. converted LV is bigger then 16GiB (%extent_size)
ATM neither thin-pool nor cache-pool supports bigger metadata.
Initial support for thin-pool used slightly smaller max size 15.81GiB
for thin-pool metadata. However the real limit later settled at 15.88GiB
(difference is ~64MiB - 16448 4K blocks).
lvm2 could not simply increase the size as it has been using hard cropping
of the loaded metadata device to avoid warnings printing warning of kernel
when the size was bigger (i.e. due to bigger extent_size).
This patch adds the new lvm.conf configurable setting:
allocation/thin_pool_crop_metadata
which defaults to 0 -> no crop of metadata beyond 15.81GiB.
Only user with these sizes of metadata will be affected.
Without cropping lvm2 now limits metadata allocation size to 15.88GiB.
Any space beyond is currently not used by thin-pool target.
Even if i.e. bigger LV is used for metadata via lvconvert,
or allocated bigger because of to large extent size.
With cropping enabled (=1) lvm2 preserves the old limitation
15.81GiB and should allow to work in the evironement with
older lvm2 tools (i.e. older distribution).
Thin-pool metadata with size bigger then 15.81G is now using CROP_METADATA
flag within lvm2 metadata, so older lvm2 recognizes an
incompatible thin-pool and cannot activate such pool!
Users should use uncropped version as it is not suffering
from various issues between thin_repair results and allocated
metadata LV as thin_repair limit is 15.88GiB
Users should use cropping only when really needed!
Patch also better handles resize of thin-pool metadata and prevents resize
beoyond usable size 15.88GiB. Resize beyond 15.81GiB automatically
switches pool to no-crop version. Even with existing bigger thin-pool
metadata command 'lvextend -l+1 vg/pool_tmeta' does the change.
Patch gives better controls 'coverted' metadata LV and
reports less confusing message during conversion.
Patch set also moves the code for updating min/max into pool_manip.c
for better sharing with cache_pool code.
When detaching writecache, make the first stage send a message
to dm-writecache to set the cleaner option. This is instead of
reloading the dm table with the cleaner option set. Reloading
the table causes udev to process/probe the dm dev, which gets
stalled because of the writeback activity, and the stalled udev
in turn stalls the lvconvert command when it tries to sync with
udev events.
When getting writecache status we do not need to get
open_count or read_head info, which can cause extra steps.
In case legs of a raid0 LV are removed, the lvdisplay command still
reports 'available' though raid0 is not providing any resilience
compared to the other raid levels.
Also lvdisplay does not display '(partial)' in case of missing raid0
legs as oposed to the lvs command.
Enhance lvdisplay to report "NOT available" for any RaidLV type in case
too many legs are inaccessible hence causing data loss. I.e. any leg
for raid0, all for raid1, more than 1 for raid4/5, more than 2 for raid6
and in case of completely lost mirror groups for raid10.
Add test/shell/lvdisplay-raid.sh.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1872678
Read buffersize - 1 so the last byte is always 0.
Simplify init of 0 buffers.
Check snprintf result for error and report internal error as it could
happen only via bad compile parameters.
New VDO targets v6.2.3 corrects support for online rename of VDO device.
If needed if can be disable via new lvm.conf setting:
vdo_disabled_features = [ "online_rename" ]
When removing pool LV from a stacked LV setup, it's been possible
to leak _pmspare and such hidden LV then required manual
user removal.
Fix it by moving automatic removal into _lv_reduce().
When adding replacement raid+integrity images (lvconvert --repair
after a raid image is lost), various errors can cause the function
to exit with an error. On this exit path, the function attempts
to revert new images that had been created but not yet used. The
cleanup failed to account for the fact that not all images needed
to be reverted.
Since commit 77fdc17d70 always include
log_len size into needed extents - however now we may need sometimes
more extents then necessary - mainly when multiple PVs are involved
into allocation.
Add logs_still_needed into calculation of sufficient_pes_free()
When a writecache sublv or an integrity metadata sublv
are partial (missing a dev), set the partial flag on
the upper level LV also, as is done for other sublvs.
Fix the two-step writecache detach in commit c32d7fed4f.
In the case of uncache, the cachevol is removed after
detaching the writecache. When the detach is finished
in the second step, the remove must wait until then.
When using cache with a cachevol, the cache_check tool was
not being run on the cache metadata during activation.
cache_check clears the needs_check flag in the cache
metadata, so if the flag was set due to an unclean
shutdown, the activation would fail.
When 'fsadm resize vg/lv' is used without size, it should just
resize filesystem to match device - but since we now check
for unbound variable in bash - the previous usage no longer
works and needs explicit check.
Verify that corruption is corrected for raid levels other
than raid1. For other raid levels, attempt to corrupt the
given file pattern on each underlying device, since we don't
know which device contains the file being corrupted.
This ensures that corruption is actually be introduced
when testing the other raid levels.
Verify that corruption is being corrected by checking
the integritymismatches count is non-zero for the raid LV,
which includes the total from all images (since we don't
know which image will have the corruption.)
Each integrity image in a raid LV reports its own number
of integrity mismatches, e.g.
lvs -o integritymismatches vg/lv_rimage_0
lvs -o integritymismatches vg/lv_rimage_1
In addition to this, allow the total number of integrity
mismatches from all images to be displayed for the raid LV.
lvs -o integritymismatches vg/lv
shows the number of mismatches from both lv_rimage_0 and
lv_rimage_1.
Enhance VDO man page with description of memory usage
and space requirements chapter.
Remove some unneeded blank lines in man page.
Use more precise terminology.
Correct examples since cpool and vpool are protected names.