Enhance activation of cached devices using cachevol.
Correctly instatiace cachevol -cdata & -cmeta devices with
'-' in name (as they are only layered devices).
Code is also a bit more compacted (although still not ideal,
as the usage of extra UUIDs stored in metadata is troublesome
and will be repaired later).
NOTE: this patch my brink potentially minor incompatiblity for 'runtime' upgrade
Instead of using 'noflush' option, switch cache_mode into WRITETHROUGH
which does not require flushing, when user confirmed he does not
want flushing for WRITEBACK (because of (partially) missing caching PV)
For wiping we activate and clear 'regular' devices,
since in case of whole process interuption (i.e. kill -9)
we leave metadata & DM table and workable state all the time.
Let vgck --updatemetadata repair cases where different mdas
hold indepedently valid but unmatching copies of the metadata,
i.e. different text metadata checksums or text metadata sizes.
vgck --updatemetadata would write the same correct
metadata to good mdas, and then to bad mdas, but the
sequence of vg_write/vg_commit calls betwen good and
bad mdas could cause a different description field to
be generated for good/bad mdas. (The description field
describing the command was recently included in the
ondisk copy of the metadata text.)
If a VG is forcibly changed from lock_type sanlock to
lock_type none, the internal lvmlock LV is left behind.
If that LV is not removed before vgremove is run on the
VG, then an internal check will be triggered by the
hidden lvmlock LV. So, check for and remove a left over
lvmlock LV during vgremove.
Add lots of vdo fields:
vdo_operating_mode - For vdo pools, its current operating mode.
vdo_compression_state - For vdo pools, whether compression is running.
vdo_index_state - For vdo pools, state of index for deduplication.
vdo_used_size - For vdo pools, currently used space.
vdo_saving_percent - For vdo pools, percentage of saved space.
vdo_compression - Set for compressed LV (vdopool).
vdo_deduplication - Set for deduplicated LV (vdopool).
vdo_use_metadata_hints - Use REQ_SYNC for writes (vdopool).
vdo_minimum_io_size - Minimum acceptable IO size (vdopool).
vdo_block_map_cache_size - Allocated caching size (vdopool).
vdo_block_map_era_length - Speed of cache writes (vdopool).
vdo_use_sparse_index - Sparse indexing (vdopool).
vdo_index_memory_size - Allocated indexing memory (vdopool).
vdo_slab_size - Increment size for growing (vdopool).
vdo_ack_threads - Acknowledging threads (vdopool).
vdo_bio_threads - IO submitting threads (vdopool).
vdo_bio_rotation - IO enqueue (vdopool).
vdo_cpu_threads - CPU threads for compression and hashing (vdopool).
vdo_hash_zone_threads - Threads for subdivide parts (vdopool).
vdo_logical_threads - Logical threads for subdivide parts (vdopool).
vdo_physical_threads - Physical threads for subdivide parts (vdopool).
vdo_max_discard - Maximum discard size volume can recieve (vdopool).
vdo_write_policy - Specified write policy (vdopool).
vdo_header_size - Header size at front of vdopool.
Previously only 'lvdisplay -m' was exposing them.
Since we now support activation of 'vdo' volume
without explicit activation of 'vdopool' it's now possible
to have active layer vdopool (-vpool) volume and
having vdopool itself inactive - yet still in this
case we can show available stats for this volume.
But we need to show correct activation status and other
standard info.
Adds support for the DM_GET_TARGET_VERSION to dmsetup.
It introduces a new comman "target-version" that will accept list
of targets and print their version.
Signed-off-by: Mikulas Patocka <mpatocka@redhat.com>
Use /dev/md33 instead of /dev/md0 to reduce chances of
conflicting with an existing name.
Only call 'mdadm --stop /dev/md33' for cleanup and don't
use 'mdadm --stop --scan' to avoid stopping other md devs.
Due to a dm-raid target flaw fixed in target version 1.15.0,
extents of raid sets don't get resynchronized when new MD bitmp
pages have to be allocated due to the extension.
Introduce lvextend-raid.sh to test this flaw.
Related: rhbz1671964
When the PV device names in the VG metadata do not match the
current PV device names seen on the system, do not use the
optimized activation function (that avoids extra device scanning.)
When the device names do not match, it's a clue that there could
be duplicate PVs, in which case we want to scan all devicess to
find any duplicates and stop the activation if found.
This does not prevent autoactivating a VG from the incorrect
duplicate PV, because the incorrect duplicate may appear by itself
first. At that point its duplicate PV does not exist to be seen.
(A future enhancement could use the WWID to strengthen this