1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
Commit Graph

2090 Commits

Author SHA1 Message Date
Zdenek Kabelac
f06dd8725a thin: mark passed args
Keep the flag whether given thin pool argument has been given on command
line or it's been 'estimated'

Call of update_pool_params() must not change cmdline given args and
needs to know this info.

Since there is a need to move this update function into /lib, we cannot
use arg_count().

FIXME: we need some generic mechanism here.
2013-03-13 15:13:54 +01:00
Peter Rajnoha
521a0a3323 dmsetup: fix 'splitname -o' to not fail if used without '-c'
This was a regression introduced with e33fd978a8
(libdm v1.02.68/lvm2 v2.02.89) with the introduction of new output
fields blkdevname and blkdevs_used for ls and deps dmsetup commands.

A new common '_process_options' fn was added with that commit, but the
fn was called prematurely which then broke processing of
'dmsetup splitname -o' which should implicitly use '-c' option
and this was failing after the commit:

  alatyr/~ $ dmsetup splitname -o lv_name /dev/mapper/vg_data-test
  Option not recognised: lv_name
  Couldn't process command line.

The '-c' had to be used for correct operation:

  alatyr/~ $ dmsetup splitname -c -o lv_name /dev/mapper/vg_data-test
  LV
  test

Now fixed to work as it did before:

  alatyr/~ $ dmsetup splitname -o lv_name /dev/mapper/vg_data-test
  LV
  test
2013-03-12 13:01:57 +01:00
Peter Rajnoha
6b777ccbb5 cleanup: get rid of compiler's warning about possible unitialized variable 2013-03-06 12:53:27 +01:00
Peter Rajnoha
7d6991e900 dumpconfig: add --ignoreadvanced and --ignoreunsupported switch
lvm dumpconfig [--ignoreadvanced] [--ignoreunsupported]

--ignoreadvanced causes the advanced configuration options to be left
out on dumpconfig output

--ignoreunsupported causes the options that are not officially supported
to be lef out on dumpconfig output
2013-03-06 10:46:36 +01:00
Peter Rajnoha
088d88cfe2 dumpconfig: add --withcomments and --withversions switch
lvm dumpconfig [--withcomments] [--withversions]

The --withcomments causes the comments to appear on output before each
config node (if they were defined in config_settings.h).

The --withversions causes a one line extra comment to appear on output
before each config node with the version information in which the
configuration setting first appeared.
2013-03-06 10:46:36 +01:00
Peter Rajnoha
34350963d1 dumpconfig: add --type, --atversion and --validate arg
lvm dumpconfig [--type {current|default|missing|new}] [--atversion] [--validate]

This patch adds above-mentioned args to lvm dumpconfig and it maps them
to creation and writing out a configuration tree of a specific type
(see also previous commit):

  - current maps to CFG_TYPE_CURRENT
  - default maps to CFG_TYPE_DEFAULT
  - missing maps to CFG_TYPE_MISSING
  - new maps to CFG_TYPE_NEW

If --type is not defined, dumpconfig defaults to "--type current"
which is the original behaviour of dumpconfig before all these changes.

The --validate option just validates current configuration tree
(lvm.conf/--config) and it writes a simple status message:

  "LVM configuration valid" or "LVM configuration invalid"
2013-03-06 10:46:36 +01:00
Peter Rajnoha
386886f71c config: refer to config nodes using assigned IDs
For example, the old call and reference:

  find_config_tree_str(cmd, "devices/dir", DEFAULT_DEV_DIR)

...now becomes:

  find_config_tree_str(cmd, devices_dir_CFG)

So we're referring to the named configuration ID instead
of passing the configuration path and the default value
is taken from central config definition in config_settings.h
automatically.
2013-03-06 10:14:33 +01:00
Peter Rajnoha
86f65a3f2b tools: add embeddingareasize arg to pvcreate and vgconvert
To create an Embedding Area during PV creation (pvcreate or as part of
the vgconvert operation), we need to define the Embedding Area size.
The Embedding Area start will be calculated automatically by the tools.

This patch adds --embeddingareasize argument to pvcreate and vgconvert.
2013-02-26 14:46:41 +01:00
Peter Rajnoha
b778653f03 pv_header_extension: add support for writing PV header extension (flags & Embedding Area)
The PV header extension information (PV header extension version, flags
and list of Embedding Area locations) is stored just beyond the PV header base.

When calculating the Embedding Area start value (ea_start), the same logic is
used as when calculating the pe_start value for Data Area - the value must
follow exactly the same alignment restrictions for its start value
(the alignment detected automatically or provided via command line using
the --dataalignment and --dataalignmentoffset arguments).

The Embedding Area is placed at the very start of the PV, starting at
ea_start. The Data Area starting at pe_start is placed next. The pe_start is
still properly aligned. Due to the pe_start alignment, it's possible that the
resulting Embedding Area size (ea_size) ends up bigger in size than requested
(but never less than requested).
2013-02-26 11:28:00 +01:00
Peter Rajnoha
9dbe25709e pv_header_extension: add support for reading PV header extension (flags & Embedding Area)
New tools with PV header extension support will read the extension
if it exists and it's not an error if it does not exist (so old PVs
will still work seamlessly with new tools).

Old tools without PV header extension support will just ignore any
extension.

As for the Embedding Area location information (its start and size),
there are actually two places where this is stored:
  - PV header extension
  - VG metadata

The VG metadata contains a copy of what's written in the PV header
extension about the Embedding Area location (NULL value is not copied):

    physical_volumes {
        pv0 {
          id = "AkSSRf-difg-fCCZ-NjAN-qP49-1zzg-S0Fd4T"
          device = "/dev/sda"     # Hint only

          status = ["ALLOCATABLE"]
          flags = []
          dev_size = 262144       # 128 Megabytes
          pe_start = 67584
          pe_count = 23   # 92 Megabytes
          ea_start = 2048
          ea_size = 65536 # 32 Megabytes
        }
    }

The new metadata fields are "ea_start" and "ea_size".
This is mostly useful when restoring the PV by using existing
metadata backups (e.g. pvcreate --restorefile ...).

New tools does not require these two fields to exist in VG metadata,
they're not compulsory. Therefore, reading old VG metadata which doesn't
contain any Embedding Area information will not end up with any kind
of error but only a debug message that the ea_start and ea_size values
were not found.

Old tools just ignore these extra fields in VG metadata.
2013-02-26 11:27:23 +01:00
Peter Rajnoha
6d8de3638c cleanup: use struct pvcreate_restorable_params throughout 2013-02-26 11:25:11 +01:00
Peter Rajnoha
6692b17777 cleanup: add struct pvcreate_restorable_params and move relevant items from pvcreate_params
Extract restorable PV creation parameters from struct pvcreate_params into
a separate struct pvcreate_restorable_params for clarity and also for better
maintainability when adding any new items later.
2013-02-26 11:24:38 +01:00
Zdenek Kabelac
b73de73151 thin: lvconvert support for external origin
Add basic support for converting LV into an external origin volume.

Syntax:

lvconvert --thinpool vg/pool  --originname renamed_origin -T origin

It will convert volume  'origin' into a thin volume, which will
use 'renamed_origin' as an external read-only origin.
All read/write into origin will go via 'pool'.

renamed_origin volume is read-only volume, that could be activated
only in read-only mode, and cannot be modified.
2013-02-23 10:38:20 +01:00
Zdenek Kabelac
386f3d5a5e thin: external origin cannot be changed
Do not allow conversion of external origin into writeable LV,
and prohibit changing the external origin size.

If the snapshot origin is also external origin, merge is prohibited.
2013-02-23 10:37:01 +01:00
Jonathan Brassow
3ab46449f4 vgimport: Allow '--force' to import VGs with missing PVs.
When there are missing PVs in a volume group, most operations that alter
the LVM metadata are disallowed.  It turns out that 'vgimport' is one of
those disallowed operations.  This is bad because it creates a circular
dependency.  'vgimport' will complain that the VG is inconsistent and that
'vgreduce --removemissing' must be run.  However, 'vgreduce' cannot be run
because it has not been imported.  Therefore, 'vgimport' must be one of
the operations allowed to change the metadata when PVs are missing.  The
'--force' option is the way to make 'vgimport' happen in spite of the
missing PVs.
2013-02-20 16:37:41 -06:00
Jonathan Brassow
70f57996b3 RAID: Add new 'raid10_segtype_default' setting in lvm.conf
If '--mirrors/-m' and '--stripes/-i' are used together when creating
a logical volume, mirrors-over-stripes is currently chosen.  The user
can override this by using the '--type raid10' option on creation.
However, we want a place where we can set the default behavior to
'raid10' explicitly - similar to the "mirror" and "raid1" tunable,
mirror_segtype_default.

A follow-on patch should use this new setting to change the default
from "mirror" to "raid10", as this is the preferred segment type.
2013-02-20 15:10:04 -06:00
Jonathan Brassow
845852d6b4 RAID: Make 'vgreduce --removemissing' work with RAID LVs
Currently it is impossible to remove a failed PV which has a RAID LV
on it.  This patch fixes the issue by replacing the failed PV with an
'error' segment within the affected sub-LVs.  Once there is no longer
a RAID LV using the PV, it can be removed.

Most often, it is better to replace a failed RAID device with a spare.
(You can use 'lvconvert --repair <vg>/<LV>' to accomplish that.)
However, if there are no spares in the volume group and none will be
added, it is useful to be able to removed the failed device.

Following patches address the ability to perform 'lvconvert' operations
on RAID LVs that contain sub-LVs composed of 'error' segments.
2013-02-20 14:52:46 -06:00
Jonathan Brassow
0e4ffd9d3b clean-up: Rename lvm.conf setting 'mirror_region_size' to 'raid_region_size'
We have been using 'mirror_region_size' in lvm.conf as the default region
size for RAID logical volumes as well as mirror logical volumes.  Since,
"raid" is more inclusive and representative than "mirror", I have changed
the name of this setting.  We must still check for the old setting and warn
the user if we are overriding it with the new setting if both happen to be
present.
2013-02-20 14:40:17 -06:00
Zdenek Kabelac
7910b6c0ba thin: update pool_is_active
Change it to take LV and move it to exported header - seems
to be a better fit for usability from tools/ directory.
2013-02-05 16:54:11 +01:00
Zdenek Kabelac
a5b9b4bf02 thin: fix forbidden discards checks
Instead of check for lv_is_active() for thin pool LV,
query the whole pool via new  pool_is_active().

Fixes a problem when we cannot change discards settings
for active pool device where the actual layer for pool
device was inactive, but thin volumes using thin pool
have been active.
2013-02-05 14:38:16 +01:00
Zdenek Kabelac
15115b61c0 lvconvert: update error path
Update the error path after problems with suspend_lv or vg_commit.
It's not exactly well defined what should happen, and this
code seems to appear in many different instancies<F2> in the
whole source code tree - we should probably pick the best version.
2013-02-05 14:31:34 +01:00
Zdenek Kabelac
be5ad90703 lvconvert: fix accepting second lv name
Do not allow to accept second LV name on lvconvert --thinpool
command line.
2013-02-05 14:31:17 +01:00
Zdenek Kabelac
7cd25062ac cleanup: avoid overflow warning
Even we do not expect to support chunks bigger then 2GB.
2013-02-05 14:27:25 +01:00
Zdenek Kabelac
d7ea12f222 cleanup: remove extra braces 2013-02-05 14:27:24 +01:00
Alasdair G Kergon
06abb2dd4c logging: classify log_debug messages
Place most log_debug() messages into a class.
2013-01-07 22:30:29 +00:00
Alasdair G Kergon
6d760b2c63 lvmetad: improve client logging when connecting
Rename lvmetad_warning() to lvmetad_connect_or_warn().

Log all connection attempts on the client side, whether successful or not.

Reduce some nesting and remove a redundant assertion.
2013-01-04 23:22:30 +00:00
Alasdair G Kergon
a527a3b8c2 lvmetad: lvm depends on libdaemonclient.a
Rebuild lvm binary if libdaemonclient.a changes.
2013-01-04 23:10:38 +00:00
Peter Rajnoha
ad85b0c526 pvscan: synchronize with udev if pvscan --cache is used.
We need to call sync_local_dev_names directly as pvscan uses
VG_GLOBAL lock and this one *does not* cause the synchronization
(sync_dev_names) to be called on unlock (VG_GLOBAL is not a real VG):

define unlock_vg(cmd, vol)
  do { \
    if (is_real_vg(vol)) \
      sync_dev_names(cmd); \
    (void) lock_vol(cmd, vol, LCK_VG_UNLOCK); \
  } while (0)

Without this fix, we end up without udev synchronization for the
pvscan --cache (mainly for -aay that causes the VGs/LVs to be
autoactivated) and also udev synchronization cookies are then left
in the system since they're not managed properly (code before sets
up udev sync cookies, but we have to call dm_udev_wait at least once
after that to do the wait and cleanup).
2012-12-21 11:15:46 +01:00
Jonathan Brassow
970dfbcd69 RAID: Limit replacement of devices when array is not in-sync.
If a RAID array is not in-sync, replacing devices should not be allowed
as a general rule.  This is because the contents used to populate the
incoming device may be undefined because the devices being read where
not in-sync.  The kernel enforces this rule unless overridden by not
allowing the creation of an array that is not in-sync and includes a
devices that needs to be rebuilt.

Since we cannot know the sync state of an LV if it is inactive, we must
also enforce the rule that an array must be active to replace devices.

That leaves us with the following conditions:
1) never allow replacement or repair of devices if the LV is in-active
2) never allow replacement if the LV is not in-sync
3) allow repair if the LV is not in-sync, but warn that contents may
   not be recoverable.

In the case where a user is performing the repair on the command line via
'lvconvert --repair', the warning is printed before the user is prompted
if they would like to replace the device(s).  If the repair is automated
(i.e. via dmeventd and policy is "allocate"), then the device is replaced
if possible and the warning is printed.
2012-12-18 14:40:42 -06:00
Zdenek Kabelac
0396ade38b cleanup: simplify option matching function
Avoid using sprintf and strncmp call, when
we really want to compare just one character.
2012-12-15 14:57:40 +01:00
Zdenek Kabelac
8b8065a870 cleanup: drop unused header
This header does not resolve any symbols here.
2012-12-15 14:57:40 +01:00
Zdenek Kabelac
03be45ac0a cleanup: convert to 32bit
Chunk sizes fits into 4G range, so keep it in 32bit range.
2012-12-15 14:57:39 +01:00
Peter Rajnoha
e8025aa67a lvconvert: also allow --type with --stripes
We can also use this for conversion between different mirror segment
types. Each new segment type converter then needs to check itself
whether the --stripes is applicable.
2012-12-13 11:19:11 +01:00
Petr Rockai
b19f840af8 toollib: Avoid a global lock in process_each_pv if lvmetad is used.
The motivation to grab the global lock is to avoid a scan and metadata parsing
for each PV, but the cost of obtaining metadata is _mostly_ mitigated by having
lvmetad around. Not taking the global lock improves throughput when multiple pvs
or related commands are running in parallel, like in RHEV.
2012-12-12 14:44:03 +01:00
Peter Rajnoha
e5709a32be lvmetad: fix compiler warning and add WHATS_NEW line for previous commit 2012-12-12 13:27:25 +01:00
Petr Rockai
f14f2d4378 lvmetad: Fix autoactivation for MDA-less PVs.
Calling pvscan --cache with -aay on a PV without an MDA would spuriously fail
with an internal error, because of an incorrect assumption that a parsed VG
structure was always available. This is not true and the autoactivation handler
needs to call vg_read to obtain metadata in cases where the PV had no MDAs to
parse. Therefore, we pass vgid into the handler instead of the (possibly NULL)
VG coming from the PV's MDA.
2012-12-12 13:19:04 +01:00
Peter Rajnoha
cad22be394 lvconvert: allow lvconvert --stripes/stripesize only with -mirrors/--repair/--thinpool
Also, update lvconvert man page to reflect this and make clear that
the --stripes/stripesize is applied to newly allocated space only.
2012-12-11 15:50:25 +01:00
Zdenek Kabelac
ed65860861 thin: remove detection for thin discard support
Remove no longer needed warning for unsuppoted discards
for non-power-2 lvcreate commands.

(Missed from the patch for the same update in lvchange made
by commit dde5a6c52b)
2012-12-11 11:24:45 +01:00
Peter Rajnoha
f942ae4a7a lvconvert: do not ignore -f in lvconvert --repair -y -f 2012-12-11 09:52:54 +01:00
Jonathan Brassow
3835755259 pvmove/RAID: Disallow pvmove on RAID LVs until properly handled
Attempting pvmove on RAID LVs replaces the kernel RAID target with
a temporary pvmove target, ultimately destroying the RAID LV.  pvmove
must be prevented on RAID LVs for now.

Use 'lvconvert --replace old_pv vg/lv new_pv' if you want to move
an image of the RAID LV.
2012-12-04 17:47:47 -06:00
Zdenek Kabelac
99018b37ee thin: lvconvert supports swapping metadata device
Support swapping of metadata device if the thin pool already
exists. This way it's easy to i.e. resize metadata or their
repair operation.

User may create some empty LV, replace existing metadata
or dump and restore them into bigger LV.
2012-12-02 18:01:27 +01:00
Zdenek Kabelac
ade2f47829 thin: deactivate subvolumes
Do not leave active thin data and metadata volumes
if activation of thin pool fails.
2012-12-02 17:56:44 +01:00
Zdenek Kabelac
dde5a6c52b thin: lvchange may change discards freely 2012-12-02 17:56:44 +01:00
Zdenek Kabelac
f0da2842cf thin: shuffle code
Reorder code lines for next patch.
2012-12-02 17:56:44 +01:00
Zdenek Kabelac
0be8a9126f thin: lvconvert update messages 2012-12-02 17:56:44 +01:00
Peter Rajnoha
fb8cc7c63f udev: do not verify udev operations for --noudevsync
If udev synchronization is disabled by means of --noudevsync
option, we should disable just the synchronization and nothing else.
The udev fallback (verifying udev operations and fixing the
nodes/symlinks if found incorrect) is orthogonal and controlled
by a separate activation/verify_udev_operations configuration option.
2012-11-29 13:59:12 +01:00
Zdenek Kabelac
09b7ceea95 thin: allow restore with --force
Allow restoring metadata with thin pool volumes.
No validation is done for this case within vgcfgrestore tool -
thus incorrect metadata may lead to destruction of pool content.
2012-11-27 14:08:24 +01:00
Zdenek Kabelac
c7a7fd0a12 thin: fix attrs for unloaded driver
If the driver is not loaded, set all 'features' ON
instead of all of them being OFF.
2012-11-27 11:29:47 +01:00
Zdenek Kabelac
1ef9831018 thin: support configurable thin pool defaults
Configurable settings for thin pool create
if they are not specified on command line.

New supported lvm.conf options are:
  allocation/thin_pool_chunk_size
  allocation/thin_pool_discards
  allocation/thin_pool_zero
2012-11-26 12:16:47 +01:00
Zdenek Kabelac
953080e4fc thin: add more unsupporte options for merge
Hmm, we need some smarter way to detect unsupported command
line options for various commands.
2012-11-26 12:15:32 +01:00
Jonathan Brassow
b3e9a09abe RAID: If no stripes argument is given for RAID10 create, default to 2
Similar to the way the 'mirror', 'raid1' and 'raid10' segment types set
the number of mirrors to 2 ('-m 1') if the argument is not specified,
here we set the number of stripes to 2 if not given on the command line
when creating a RAID10 LV.
2012-11-21 18:46:52 -06:00
Zdenek Kabelac
999952c5b9 thin: update recent patchset
Parse pool params only for creation of thin pools.
2012-11-19 16:28:00 +01:00
Zdenek Kabelac
1794f777f4 thin: lvcreate use common functions
Use common functions from toollib and eliminate code from here.
2012-11-19 14:38:17 +01:00
Zdenek Kabelac
b21d3e3592 thin: lvconvert update
Use common function from toollib and support allocation
of metadata LV with give thin pool data LV.
2012-11-19 14:38:17 +01:00
Zdenek Kabelac
b786096863 thin: add alloc_pool_metadata
Since our api call is not yet powerfull enough,
use this wrapper to preset options.
2012-11-19 14:38:17 +01:00
Zdenek Kabelac
f4137640f6 thin: add common pool functions
Move common functions for lvcreate and lvconvert.

get_pool_params() - read thin pool args.
update_pool_params() - updates/validates some thin args.

It is getting complicated and even few more things will be
implemented, so to avoid reimplementing things differently
in lvcreate and lvconvert  code has been splitted
into 2 common functions that allow some future extension.
2012-11-19 14:38:17 +01:00
Zdenek Kabelac
cf5242a670 lvconvert: store target attributes
Target tells us its version, and we may allow different set of options
to be supported with different version of driver.

Idea is to provide individual feature flags and later be
able to query for them.
2012-11-19 14:17:10 +01:00
Zdenek Kabelac
2c3bbf0a6c cleanup: move setting of parameter zero
Since we may need to use different default value,
move read of zero_ARG prior processing of parameters.
2012-11-19 14:15:43 +01:00
Jonathan Brassow
54c73b7723 mirror: Mirrored log should be fixed before mirror when double fault occurs
This patch is intended to fix bug 825323 - FS turns read-only during a double
fault of a mirror leg and mirrored log's leg at the same time.  It only
affects a 2-way mirror with a mirrored log.  3+-way mirrors and mirrors
without a mirrored log are not affected.

The problem resulted from the fact that the top level mirror was not
using 'noflush' when suspending before its "down-convert".  When a
mirror image fails, the bios are queue until a suspend is recieved.  If
it is a 'noflush' suspend, the bios can be safely requeued in the DM
core.  If 'noflush' is not used, the bios must be pushed through the
target and if a device is failed for a mirror, that means issuing an
error.  When an error is received by a file system, it results in it
turning read-only (depending on the FS).

Part of the problem was is due to the nature of the stacking involved in
using a mirror as a mirror's log.  When an image in each fail, the top
level mirror stalls because it is waiting for a log flush.  The other
stalls waiting for corrective action.  When the repair command is issued,
the entire stacked arrangement is collapsed to a linear LV.  The log
flush then fails (somewhat uncleanly) and the top-level mirror is suspended
without 'noflush' because it is a linear device.

This patch allows the log to be repaired first, which in turn allows the
top-level mirror's log flush to complete cleanly.  The top-level mirror
is then secondarily reduced to a linear device - at which time this mirror
is suspended properly with 'noflush'.
2012-11-14 14:58:47 -06:00
Peter Rajnoha
fc2644ae71 pvscan: exit --cache immediately if locking_type=3 || use_lvmetad=0 2012-11-09 15:56:57 +01:00
Zdenek Kabelac
5f5a5d1f53 lvchange: support --yes option for --persistent
Support using command: lvchange --yes --persistent
to skip y|n prompt.
2012-10-19 15:33:46 +02:00
Zdenek Kabelac
bc7d3b74f1 cleanup: fix typo in error message
yes -> yet
2012-10-19 15:32:27 +02:00
Zdenek Kabelac
c7c53ad41d pvcreate: fix leak on error path
Missing vg release on error path.
Add tests for few more error cases.
2012-10-19 15:32:21 +02:00
Zdenek Kabelac
f260f99d57 cleanup: switch log_error to log_warn
Use log_warn to print non-fatal warning messages.

Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
2012-10-17 15:41:35 +02:00
Zdenek Kabelac
b89963a7c3 cleanup: swap return values
Use lvm standard return code for success/fail  1/0.
2012-10-17 15:37:26 +02:00
Alasdair G Kergon
ea6a8078b4 release: prepare for release 2012-10-15 15:19:32 +01:00
Zdenek Kabelac
4573877186 lvchange: resync returns error on usupported volumes 2012-10-15 14:09:37 +02:00
Zdenek Kabelac
b3899056d9 thin: disable conversion of thin-pool to read-only
This change is not yet supported.
2012-10-15 14:09:11 +02:00
Zdenek Kabelac
2fc1fc3a93 thin: allow to create read-only thin-volumes
Useful for i.e. read-only thin snapshots.
2012-10-15 14:07:03 +02:00
Zdenek Kabelac
9bb210192d cleanup: readable test to check for 32bit overflow
also swap return value 0 - fail, 1 - success.
2012-10-14 23:19:27 +02:00
Zdenek Kabelac
16060b101b thin: lvextend will fail is autoextend is 0%
Since extending by 0% will not increase the size of pool,
return failure.
2012-10-14 23:17:30 +02:00
Zdenek Kabelac
31d8c3ee85 debug: do not play with fds with valgring
When valgrind usage is desired by user (--enable-valgrind-pool)
skip playing/closing/reopenning with descriptors - it makes
valgridng useless.

Make sleep delay for clvmd start longer.
2012-10-12 17:02:30 +02:00
Zdenek Kabelac
3058f662cf thin: prohibit lvcreate --thinpool with mirrors
Disable --thinpool to be used with mirror on lvcreate.
2012-10-12 12:21:45 +02:00
Petr Rockai
28776b9526 lvmetad: Make --sysinit suppress connection failure warnings. 2012-10-12 10:58:04 +02:00
Zdenek Kabelac
ca09c9ab4c thin: support non power of 2 chunk size
Support thin chunk size with multiple of 64KiB if user has
thin-pool target version at least 1.2.
2012-10-10 21:21:00 +02:00
Jonathan Brassow
3501f17fd0 [lv|vg]change: Allow limited metadata changes when PVs are missing
A while back, the behavior of LVM changed from allowing metadata changes
when PVs were missing to not allowing changes.  Until recently, this
change was tolerated by HA-LVM by forcing a 'vgreduce --removemissing'
before trying (again) to add tags to an LV and then activate it.  LVM
mirroring requires that failed devices are removed anyway, so this was
largely harmless.  However, RAID LVs do not require devices to be removed
from the array in order to be activated.  In fact, in an HA-LVM
environment this would be very undesirable.  Device failures in such an
environment can often be transient and it would be much better to restore
the device to the array than synchronize an entirely new device.

There are two methods that can be used to setup an HA-LVM environment:
"clvm" or "tagging".  For RAID LVs, "clvm" is out of the question because
RAID LVs are not supported in clustered VGs - not even in an exclusively
activated manner.  That leaves "tagging".  HA-LVM uses tagging - coupled
with 'volume_list' - to ensure that only one machine can have an LV active
at a time.  If updates are not allowed when a PV is missing, it is
impossible to add or remove tags to allow for activation.  This removes
one of the most basic functionalities of HA-LVM - site redundancy.  If
mirroring or RAID is used to replicate the storage in two data centers
and one of them goes down, a server and a storage device are lost.  When
the service fails-over to the alternate site, the VG will be "partial".
Unable to add a tag to the VG/LV, the RAID device will be unable to
activate.

The solution is to allow vgchange and lvchange to alter the LVM metadata
for a limited set of options - --[add|del]tag included.  The set of
allowable options are ones that do not cause changes to the DM kernel
target (like --resync would) or could alter the structure of the LV
(like allocation or conversion).
2012-10-10 11:33:10 -05:00
Peter Rajnoha
470d1a2f54 dmsetup: also apply 'mangle' command for UUIDs
Compared to names, UUIDs can't be renamed once they are created
for a device. The 'mangle' command will just issue an error message
about a need for manual intervention in this case - reactivating the
device (remove + create) does the job as the defualt mangling mode
used is "auto" and that will assign a correct mangled form the UUID.
2012-10-10 17:16:15 +02:00
Peter Rajnoha
788b7a6a2b dmsetup: add mangled/unmangled_uuid to for info -c
Following the same logic already used for name mangling.
2012-10-10 17:16:15 +02:00
Zdenek Kabelac
cdb7502e54 lvchange: do not start dmevent for resyn
If monitoring is disabled in lvm.conf, avoid its starting and preserve
DMEVENTD_MONITOR_IGNORE settings internally.
2012-10-09 12:22:26 +02:00
Zdenek Kabelac
5b07bd3f91 lvconvert: disable convertion of thin to mirrors
For now this convertions is not supported, thus disabled.
The only supported conversion for now is to create mirrored thin pools
from mirrored devices.
2012-10-08 12:16:53 +02:00
Zdenek Kabelac
a27650cc98 thin: lvconvert
Update code for lvconvert.
Change the lvconvert user interface a bit - now we require 2 specifiers
--thinpool   takes LV name for data device (and makes the name)
--poolmetadata  takes LV name for metadata device.

Fix type in thin help text -z -> -Z.

Supported is also new flag --discards for thinpools.
2012-10-03 15:13:33 +02:00
Zdenek Kabelac
e9f83147d5 thin: lvchange allows to change perms of thin snap
Thin snapshots are individual thin volumes so they can have its own
control for rw permissions.
2012-10-03 15:13:32 +02:00
Zdenek Kabelac
4648d33d07 cleanup: add proper cast for force_t 2012-10-03 15:06:17 +02:00
Zdenek Kabelac
739092e64a liblvm2cmd: ensure standard descriptors are ready
Check if FDs 0,1,2 are available, and in case they are missing,
use /dev/null for them.
2012-10-03 15:02:26 +02:00
Zdenek Kabelac
1f30e048bd liblvm2cmd: add return code for _close_stray_fds
Close fds via /proc/self/fd parsing
Return error code if _close_stray_fds fails and quit application
if system is in some nonstandard state.
2012-10-03 15:01:23 +02:00
Petr Rockai
3124840185 lvremove: Revert to allowing removal of partial LVs. 2012-09-26 17:26:23 +02:00
Petr Rockai
e7d3553906 lvmetad: Make vgscan --cache an alias to pvscan --cache. 2012-09-26 17:26:23 +02:00
Petr Rockai
ca0c8673b2 lib/cache/lvmetad: s/pvscan_lvmetad/lvmetad_pvscan/ in the API 2012-09-26 17:26:23 +02:00
Petr Rockai
c7b17836ea Implement devices/global_filter.
The global filter is applied first, and is also applied in pvscan --cache (which
is called from udev rules to keep lvmetad updated). Cf. example.conf.
2012-09-26 14:49:15 +02:00
Marian Csontos
17901569da cleanup: remove unused variable 2012-09-20 07:40:11 +02:00
Jonathan Brassow
2e04681248 mirror: 'lvconvert --resync' should reset LV_NOTSYNCED on corelog mirror
When reformatting the 'lvchange_resync' code in commit
05131f5853, a '!' should have been removed
from the condition that checks for the LV_NOTSYNCED flag on a corelog
mirror LV.  The presence of this '!' caused the LV_NOTSYNCED flag to be
cleared when it wasn't present and left when it was present.

It is not allowed to add images to a 'mirror' or 'raid1' LV if the
LV_NOTSYNCED flag is set.  We add some up-convert tests to ensure this
behavior is being enforced and that the LV_NOTSYNCED flag is being
properly cleared by 'lvchange --resync'.

(Not updating WHATS_NEW because this is intrarelease.)
2012-09-19 11:16:45 -05:00
Alasdair G Kergon
b737ff01e4 discards: skip when removing LVs on missing PVs
Don't try to issue discards to a missing PV to avoid segfault.
Prevent lvremove from removing LVs that have any part missing.

https://bugzilla.redhat.com/857554
2012-09-19 12:48:56 +01:00
Peter Rajnoha
3127160626 vgchange: fix -aay to activate proper volumes
Using 'activation/auto_activation_volume_list = [ "vg/lvol1" ]'.

Before this patch:
  3 logical volume(s) in volume group "vg" now active
  LV    VG   Attr     LSize Pool Origin Data%  Move Log Copy%  Convert
  lvol0 vg   -wi----- 4.00m
  lvol1 vg   -wi-a--- 4.00m
  lvol2 vg   -wi-a--- 4.00m
  lvol3 vg   -wi-a--- 4.00m

(vg/lvol1 activated as it passes the list and all subsequent volumes too - wrong!)

With this patch:
  1 logical volume(s) in volume group "vg" now active
  LV    VG   Attr     LSize Pool Origin Data%  Move Log Copy%  Convert
  lvol0 vg   -wi----- 4.00m
  lvol1 vg   -wi-a--- 4.00m
  lvol2 vg   -wi----- 4.00m
  lvol3 vg   -wi----- 4.00m

(only vg/lvol1 activated as it passes the list and no other - correct!)
2012-09-12 09:47:40 +02:00
Jonathan Brassow
4ededc698f RAID: Properly handle resync of RAID LVs
Issuing a 'lvchange --resync <VG>/<RAID_LV>' had no effect.  This is
because the code to handle RAID LVs was not present.  This patch adds
the code that will clear the metadata areas of RAID LVs - causing them
to resync upon activation.
2012-09-11 13:09:35 -05:00
Jonathan Brassow
a2d9b1a7e9 cleanup: Restructure code that handles mirror resyncing
When an LV is to be resynced, the metadata areas are cleared and the
LV is reactivated.  This is true for mirroring and will also be true
for RAID LVs.  We restructure the code in lvchange_resync() so that we
keep all the common steps necessary (validation of ability to resync,
deactivation, activation of meta/log devices, clearing of those devices,
etc) and place the code that will be divergent in separate functions:
	detach_metadata_devices()
	attach_metadata_devices()

The common steps will be processed on lists of metadata devices.  Before
RAID capability is added, this will simply be the mirror log device (if
found).

This patch lays the ground-work for adding resync of RAID LVs.
2012-09-11 13:01:05 -05:00
Jonathan Brassow
05131f5853 cleanup: Reduce indentation by short-circuiting function
By changing the conditional for resyncing mirrors with core-logs a
bit, we can short-circuit the rest of the function for that case
and reduce the amount of indenting in the rest of the function.

This cleanup will simplify future patches aimed at properly handling
the resync of RAID LVs.
2012-09-11 12:55:17 -05:00
Jonathan Brassow
c3eb3a7687 cleanup: Use segtype->ops->name() instead of segtype->name where applicable
When printing a message for the user and the lv_segment pointer is available,
use segtype->ops->name() instead of segtype->name.  This gives a better
user-readable name for the segment.  This is especially true for the
'striped' segment type, which prints "linear" if there is an area_count of
one.
2012-09-05 11:35:54 -05:00
Peter Rajnoha
c68c157573 setvbuf: reopen only valid fd
We should check whether the fd is opened before trying to reopen it.
For example, the stdin is closed in test/lib/harness.c causing the
test suite to fail.
2012-08-27 13:07:07 +02:00
Alasdair G Kergon
438e0050df config: add silent mode
Accept -q as the short form of --quiet.
Suppress non-essential standard output if -q is given twice.
Treat log/silent in lvm.conf as equivalent to -qq.
Review all log_print messages and change some to
log_print_unless_silent.

When silent, the following commands still produce output:
dumpconfig, lvdisplay, lvmdiskscan, lvs, pvck, pvdisplay,
pvs, version, vgcfgrestore -l, vgdisplay, vgs.
[Needs checking.]

Non-essential messages are shifted from log level 4 to log level 5
for syslog and lvm2_log_fn purposes.
2012-08-25 20:35:48 +01:00
Jonathan Brassow
4047e4dfb1 RAID: Add support for RAID10
This patch adds support for RAID10.  It is not the default at this
stage.  The user needs to specify '--type raid10' if they would like
RAID10 instead of stacked mirror over stripe.
2012-08-24 15:34:19 -05:00
Zdenek Kabelac
109b3bb49b thin: discard 2012-08-23 14:38:48 +02:00
Zdenek Kabelac
57c0f72b1d lvconvert: use _reload_lv on more places
Use common subroutine.
2012-08-23 14:38:45 +02:00
Zdenek Kabelac
4698fb0543 lvconvert: move _reload_lv()
Just move in front
2012-08-23 14:37:52 +02:00
Zdenek Kabelac
fd417db274 check: add internal errors for unexpected paths
Adding couple INTERNAL_ERROR reports for unwanted parameters:

Ensure the 'top' metadata node cannot be NULL for lvmetad.

Make obvious vginfo2 cannot be NULL.

Report internal error if handler and vg is undefined.

Check for handle in poll_vg().

Ensure seg is not NULL in dev_manager_transient().

Report missing read_ahead for _lv_read_ahead_single().

Check for report handler in dm_report_object().

Check missing VG in _vgreduce_single().
2012-08-23 14:37:52 +02:00
Zdenek Kabelac
195fe03075 cleanup: use proper activation_change_t 2012-08-23 14:37:38 +02:00
Zdenek Kabelac
90191e6ff2 cleanup: cast to matching type 2012-08-23 14:37:38 +02:00
Zdenek Kabelac
bd67a3151a cleanup: uint64_t casts 2012-08-23 14:37:21 +02:00
Zdenek Kabelac
ff86c6ed00 cleanup: keep MKNOD type cast clean
Setup major already a dev_t type before it gets shifted.
2012-08-23 14:37:21 +02:00
Zdenek Kabelac
286cd2006b cleanup: drop unneeded included header files
This headers were not resolving anything used for compiled .c files.
Remove unused util.c file.
2012-08-23 14:37:20 +02:00
Zdenek Kabelac
b1640df5e6 dmsetup: check if new_name is non NULL 2012-08-23 14:37:18 +02:00
Zdenek Kabelac
b9ae22d758 dmsetup: fix udev warning message
Configure option is --enable-udev_sync.
2012-08-23 14:36:12 +02:00
Zdenek Kabelac
7e318dad42 dmsetup: fix memleak in _get_split_name
Free allocated buffer in _get_split_name error path.
2012-08-23 14:36:10 +02:00
Zdenek Kabelac
54c24193f5 thin: lvcreate --discards 2012-08-09 16:25:52 +02:00
Jonathan Brassow
de3b1c4506 RAID: Improve RAID argument handling.
Disallow '-m' for RAID types that have no mirror component and disallow
'-i' argument for RAID types that have no stripe component.
2012-08-08 12:32:27 -05:00
Alasdair G Kergon
701b4a8363 thin: use discards as plural rather than singular
Global change from --discard to --discards, as that feels more natural.
2012-08-07 21:24:41 +01:00
Alasdair G Kergon
1ca813083f thin: tidy commands.h arg lists
args are listed alphabetically.
lvconvert -T is covered in the second section not the first.
It could be tidied further or split out.
2012-08-07 20:10:06 +01:00
Alasdair G Kergon
b51241a346 thin: mention discard/zero in lvchange errmsg 2012-08-07 20:08:14 +01:00
Peter Rajnoha
6e55201144 args: increase major:minor limit to 4095:1048575
Remove the limit for major and minor number arguments used while specifying
persistent numbers via -My --major <major> --minor <minor> option which
was set to 255 before. Follow the kernel limit instead which is 12 bits
for major and 20 bits for minor number (kernel >= 2.6 and LVM formats
that does not have FMT_RESTRICTED_LVIDS - so still keep the old limit
of 255 for lvm1 format).
2012-08-06 18:01:01 +02:00
Alasdair G Kergon
25ae0b39b7 dmsetup: allow --noflush with status/wait for thin
Allow --noflush with dmsetup status and wait (for thin target 1.3.0 /
ioctl 4.23.0).
2012-07-27 20:03:07 +01:00
Jonathan Brassow
186a2772e8 vgextend: Allow PVs to be added to VGs that have PVs missing
Allowing people to add devices to a VG that has PVs missing helps
people avoid the inability to repair RAID LVs in certain cases.
For example, if a user creates a RAID 4/5/6 LV using all of the
available devices in a VG, there will be no spare devices to
repair the LV with if a device should fail.  Further, because the
VG is missing a device, new devices cannot be added to allow the
repair.  If 'vgreduce --removemissing' were attempted, the
"MISSING" PV could not be removed without also destroying the RAID
LV.

Allowing vgextend to operate solves the circular dependency.

When the PV is added by a vgextend operation, the sequence number is
incremented and the 'MISSING' flag is put on the PVs which are missing.
2012-07-26 17:06:06 -05:00
Zdenek Kabelac
48367c5be9 thin: add lvchange for discard and zero change
Update lvchange to allow change of 'zero' flag for thinpool.
Add support for changing discard handling.

N.B.  from/to  ignore could be only changed for inactive pool.
2012-07-18 14:38:34 +02:00
Zdenek Kabelac
ebbf7d8e68 thin: add discard support for thin pool
Add arg support for discard.
Add discard ignore, nopassdown, passdown (=default) support.
Flags could be set per pool.

lvcreate [--discard {ignore|no_passdown|passdown}]  vg/thinlv
2012-07-18 14:36:57 +02:00
Peter Rajnoha
07e4ac7b00 lvconvert: count % upwards when merging a snapshot
Before:
  # lvconvert --merge -i 1 vg/lvol1
  Merging of volume lvol1 started.
  lvol0: Merged: 36.7%
  lvol0: Merged: 21.3%
  lvol0: Merged: 5.8%
  lvol0: Merged: 0.0%
  Merge of snapshot into logical volume lvol0 has finished.
  Logical volume "lvol1" successfully removed

After:
  # lvconvert --merge -i 1 vg/lvol1
  Merging of volume lvol1 started.
  lvol0: Merged: 61.4%
  lvol0: Merged: 73.0%
  lvol0: Merged: 88.4%
  lvol0: Merged: 100.0%
  Merge of snapshot into logical volume lvol0 has finished.
  Logical volume "lvol1" successfully removed
2012-07-10 15:30:18 +02:00
Peter Rajnoha
cd8ea8b437 activate: skip manual activation for --sysinit -aay
When --sysinit -a ay is used with vg/lvchange and lvmetad is up and running,
we should skip manual activation as that would be a useless step - all volumes
are autoactivated once all the PVs for a VG are present.

If lvmetad is not active at the time of the vgchange --sysinit -a ay
call, the activation proceeds in standard 'manual' way.

This way, we can still have vg/lvchange --sysinit -a ay called
unconditionally in system initialization scripts no matter if lvmetad
is used or not.
2012-07-10 14:01:33 +02:00
Jonathan Brassow
8767435ef8 RAID: Fix extending size of RAID 4/5/6 logical volumes.
Reducing a RAID 4/5/6 LV or extending it with a different number of
stripes is still not implemented.  This patch covers the "simple" case
where the LV is extended with the same number of stripes as the orginal.
2012-06-26 09:44:54 -05:00
Alasdair G Kergon
1d0a2b919f toollib: fix ignored_mdas process_each_pv rescan
In process_each_pv() if we haven't yet scanned and the PV appears
to be an orphan, we must scan the other PVs looking for mdas that
reference it to find out what VG it is in.

1. If the PV has no mdas, we must scan.
2. If the PV has an mda that is not ignored we do not need to scan.
3. If the PV has an mda that is ignored, we do need to scan.

This patch fixes case 3.

> pvs -o +mda_count,vg_mda_count /dev/loop[0123]
  PV         VG   Fmt  Attr PSize  PFree  #PMda #VMda
  /dev/loop0 vg3  lvm2 a-   96.00m 96.00m     0     1
  /dev/loop1 vg3  lvm2 a-   96.00m 96.00m     1     1
  /dev/loop2 vg2  lvm2 a-   96.00m 96.00m     1     2
  /dev/loop3 vg2  lvm2 a-   28.00m 28.00m     1     2

Before:
> pvs /dev/loop2 /dev/loop3 /dev/loop0 /dev/loop1 --unbuffered
  PV         VG   Fmt  Attr PSize   PFree
  /dev/loop2      lvm2 a--  100.00m 100.00m
  /dev/loop3 vg2  lvm2 a--   28.00m  28.00m
  /dev/loop0      lvm2 a--  100.00m 100.00m
  /dev/loop1 vg3  lvm2 a--   96.00m  96.00m

After:
> pvs /dev/loop2 /dev/loop3 /dev/loop0 /dev/loop1 --unbuffered
  PV         VG   Fmt  Attr PSize  PFree
  /dev/loop2 vg2  lvm2 a--  96.00m 96.00m
  /dev/loop3 vg2  lvm2 a--  28.00m 28.00m
  /dev/loop0 vg3  lvm2 a--  96.00m 96.00m
  /dev/loop1 vg3  lvm2 a--  96.00m 96.00m
2012-06-29 21:22:09 +01:00
Peter Rajnoha
a2f4ccd839 lvcreate: add --activate ay (autoactivate)
One can use "lvcreate --aay" to have the newly created volume
activated or not activated based on the activation/auto_activation_volume_list
this way.

Note: -Z/--zero is not compatible with -aay, zeroing is not used in this case!
When using lvcreate -aay, a default warning message is also issued that zeroing
is not done.
2012-06-28 09:44:07 -04:00
Peter Rajnoha
c9b9077b44 lvchange: add --activate ay (autoactivate)
The same as for vgchange...
2012-06-28 09:44:07 -04:00
Peter Rajnoha
d2df8dddc8 pvscan: add --activate ay option (autoactivate)
Define auto_activation_handler that activates VGs/LVs automatically
based on the activation/auto_activation_volume_list (activating all
volumes by default if the list is not defined).

The autoactivation is done within the pvscan call in 69-dm-lvmetad.rules
that watches for udev events (device appearance/removal).

For now, this works for non-clustered and complete VGs only.
2012-06-28 09:44:03 -04:00
Peter Rajnoha
215a314f19 vgchange: add --activate ay option (autoactivate)
Normally, the 'vgchange -ay' activates all volume groups (that pass
the activation/volume_list filter if set).

This call can appear in two scenarios:
 - system boot (so activation within a script in general)
 - manual call on command line (so activaton on user's direct request)

For the former one, we would like to select which VGs should be actually
activated. One can define the list of VGs directly to do that. But that
would require the same list to be provided in all the scripts.

The 'vgchange -aay' will check for the activation/auto_activation_volume_list
in adition and it will activate only those VGs/LVs that pass this
filter (assuming all to be activated if the list is not defined - the
same logic we already have for activation/volume_list).

Init/boot scripts should use this form of activation primarily
(which, anyway, becomes only a fallback now with autoactivation done
on PV appearance in tandem with lvmetad in place).
2012-06-28 09:42:48 -04:00
Peter Rajnoha
95ced7a7be activate: add autoactivation hooks
Define an 'activation_handler' that gets called automatically on
PV appearance/disappearance while processing the lvmetad_pv_found
and lvmetad_pv_gone functions that are supposed to update the
lvmetad state based on PV availability state. For now, the actual
support is for PV appearance only, leaving room for PV disappearance
support as well (which is a more complex problem to solve as this
needs to count with possible device stack).

Add a new activation change mode - CHANGE_AAY exposed as
'--activate ay/-aay' argument ('activate automatically').

Factor out the vgchange activation functionality for use in other
tools (like pvscan...).
2012-06-28 09:42:47 -04:00
Peter Rajnoha
2729720fd3 args: add --activate synonym for --available arg
We're refererring to 'activation' all over the code and we're talking
about 'LVs being activated' all the time so let's use 'activation/activate'
everywhere for clarity and consistency (still providing the old
'available' keyword as a synonym for backward compatibility with
existing environments).
2012-06-28 09:42:44 -04:00
Zdenek Kabelac
6bd3864b41 thin: fix lvconvert error path NULL dereference
For printing the name, use given command line parameter.
2012-06-22 13:50:21 +02:00
Zdenek Kabelac
6f3cd63551 cleanup: replace memset with struct initilization
Simplifies the code, properly detects too long socket paths,
drops unused parameter.
2012-06-22 13:23:03 +02:00
Zdenek Kabelac
ba222c6e35 cleanup: use struct initializers instead of memset
No need to call memset if we the language can do that.
2012-06-20 14:47:54 +02:00
Alasdair G Kergon
a2a37f8fee More .gitignore files for an in-source-tree build.
Tell git to ignore files generated by a build inside the source tree.
2012-06-08 16:34:43 +01:00
Alasdair G Kergon
d644d4e14e Add .gitignore files for an in-source-tree build.
Tell git to ignore files generated by a build inside the source tree.
2012-06-08 16:26:21 +01:00
Peter Rajnoha
06738cac05 Remove unsupported udev_get_dev_path libudev call used for checking udev dir.
With latest changes in the udev, some deprecated functions were removed
from libudev amongst which there was the "udev_get_dev_path" function
we used to compare a device directory used in udev and directore set in
libdevmapper. The "/dev" is hardcoded in udev now (udev version >= 183).

Amongst other changes and from packager's point of view, it's also
important to note that the libudev development library ("libudev-devel")
could now be a part of the systemd development library ("systemd-devel")
because of the udev + systemd merge.
2012-05-29 08:09:10 +00:00
Zdenek Kabelac
0a9f894ff0 Initial support for lvconvert for thin pool volumes.
Support has many limitations and lots of FIXMEs inside,
however it makes initial task when user creates a separate LV for
thin pool data and thin metadata already usable, so let's enable
it for testing.

Easiest API:

lvconvert --chunksize XX --thinpool data_lv  metadata_lv

More functionality extensions will follow up.

TODO: Code needs some rework since a lot of same code is getting copied.
2012-05-09 12:17:06 +00:00
Peter Rajnoha
d13f356bf5 Also rename DevNos header to DevNosUsed in dmsetup info -c output. 2012-04-24 08:24:36 +00:00
Peter Rajnoha
0be6c87a56 Rename (Blk)DevNames header to (Blk)DevNamesUsed in dmsetup info -c output.
Just to make it clearer since there is the "dmsetup info -c -o blkdevname"
as well that shows the "block device name for this mapping", having a
"BlkDevName" header on output.

It's a bit confusing then if the "dmsetup info -c -o devs_used,blkdevs_used"
is named with a plural "DevNames"/"BlkDevNames" but at the same time having
a totally different meaning than the singular form "BlkDevName".

  DevNames --> DevNamesUsed
  BlkDevNames --> BlkDevNamesUsed

...makes it much more comprehensible.
2012-04-24 08:00:55 +00:00
Jonathan Earl Brassow
1a53400723 Fix for bug 807776: invalid lvconvert --merge output should mention raid1 now
s/snapshot/mergeable volume/
2012-04-19 21:50:37 +00:00
Alasdair Kergon
e38e9e588e Remove 'up' from rounding message that sometimes rounds down.
Detect reduction of 0 after rounding for stripes and avoid warning of potential data loss.
2012-04-12 15:11:21 +00:00
Alasdair Kergon
1c1487659e spacing 2012-04-11 12:49:10 +00:00
Zdenek Kabelac
5dc27b75eb Fix lvresize for thin pool
When resizing thin pool - we need to use strip info from  _tdata volume.
In future more generic solution will be necessary once we start to support
lvconvert (resize of stacked devices and stay properly aligned).
For now we just allow striped or linear LV so this code will work.
2012-04-11 12:40:03 +00:00
Zdenek Kabelac
6fc1f948c2 Lvresize rounds upward
When given lvresize new size - round upward for stripes - unless we use % and
we are at the border of free extents.

This patch is not a complete fix and few more cases will need special care.
2012-04-11 12:36:37 +00:00
Zdenek Kabelac
c6f3701a71 Support rounding downward for lvcreate and %
If specifying size with % and we are reaching number
of free extents - round downward with stripes.
2012-04-11 12:33:34 +00:00
Zdenek Kabelac
9bdff1ee5c Move check for min strip size
and remove few asigns that are not needed.
2012-04-11 12:30:48 +00:00
Zdenek Kabelac
6e826bb6a4 Fix unlocking in error path of vgreduce
When vg_read fails, it internally unlocks VG if it's been locked,
so in error path we should skip unlock_vg for this case.
(user would see ugly internal warning)
2012-03-30 14:59:35 +00:00
Peter Rajnoha
543eaed88c Detect VG name being part of the LV name in lvconvert --splitmirrors -n.
Before:
devel/~ # lvconvert --splitmirrors 1 -n vg/splitted_one vg/mirrored_one
  Internal error: LV name vg/splitted_one has invalid form.
  Intermediate VG metadata write failed.

After:
devel/~ # lvconvert --splitmirrors 1 -n vg/splitted_one vg/mirrored_one
  Logical volume mirrored_one converted.

devel/~ # lvconvert --splitmirrors 1 -n abc/splitted_one vg/mirrored_one
  Please use a single volume group name ("vg" or "abc")
  Run `lvconvert --help' for more information.
2012-03-30 08:58:02 +00:00
Milan Broz
be36c0ec49 Fail early if cmirror is not detected and pvmove requires it. 2012-03-27 12:01:22 +00:00
Milan Broz
3d5d5196d0 Also skip pvmove for remotely active LVs. 2012-03-27 11:43:32 +00:00
Peter Rajnoha
3be9089cd3 Add 'vgscan --cache' functionality for consistency with 'pvscan --cache'.
Calling vgscan alone should reuse information from the lvmetad (if running).
The --cache option should initiate direct device scan and update lvmetad
appropriately (if running).

This is mainly for vgscan to behave consistently compared to pvscan.
2012-03-27 11:04:46 +00:00
Milan Broz
ddb31b62e5 Keep exclusive activation in pvmove if LV is already active.
Pvmove should never try to downgrade exclusive lock
for LVs.

This allows pvmove to work again for exclusive activated LVs.
2012-03-26 20:33:40 +00:00
Milan Broz
dcd90bc501 Do not allow pvmove if some affected LVs are activated
locally or on more nodes while others are activated exclusively.

Current pvmove code can either use local mirror (for exclusive
activation) or cmirror (for clustered LVs).

Because the whole intenal pvmove LV is just segmented LV containing
segments of several top-level LVs, code cannot properly handle
situation if some segment need to be activated exclusively.

Previously, it wrongly activated exclusive LV on all nodes
(locing code allowed it) but now this is no lnger possible.

If there is exclusively activated LV, pvmove is only
possible if all affected LVs are aslo activated exclusively.

(Note that in non-exclusive mode pvmove still activates LVs
on other nodes during move.)

# lvchange -aly vg_test/lv1
# lvchange -aey vg_test/lv2
# pvmove -i 1 /dev/sdc
   Error locking on node bar-01: Device or resource busy
   Error locking on node bar-03: Volume is busy on another node
...
   Failed to activate lv2
2012-03-26 20:32:58 +00:00
Milan Broz
3366541aab Use new flag PVMOVE_EXCLUSIVE in update_metatada call.
There is no real functional change in this patch except it
avoids checking cluster cmirror module twice.

(Flag used in following patch.)
2012-03-26 20:31:01 +00:00
Zdenek Kabelac
2caa558e7c Update and fix monitoring of thin pool devices
Code adds better support for monitoring of thin pool devices.
update_pool_lv uses DMEVENTD_MONITOR_IGNORE to not manipulate with monitoring.
vgchange & lvchange are checking real thin pool device for existance
as we are using   _tpool  real device and visible LV pool device might not
be even active (_tpool is activated implicitely for any thin volume).
monitor_dev_for_events is another _lv_postorder like code it might be worth
to think about reusing it here - for now update the code to properly
monitory thin volume deps.
For unmonitoring add extra code to check the usage of thin pool - in case it's in use
unmonitoring of thin volume is skipped.
2012-03-23 09:58:04 +00:00
Petr Rockai
7720ed7037 Fix a regression in handling --major/--minor arguments to lvcreate & lvchange,
by allowing arg_int_value to be used with groupable options.
2012-03-16 10:43:52 +00:00
Alasdair Kergon
bba1e4d11f Fix error message when pvmove LV activation fails with name already in use. 2012-03-13 20:21:26 +00:00
Zdenek Kabelac
f6632c1ef4 Fix error path for create_toolcontext
Never return unfinished toolcontext - since error path is hit on
various stages of initialization we cannot leave it partially uninitialized,
since we would need to spread many more test across the code for config_valid.
Instead return NULL and properly release udev library resources as well.
2012-03-12 14:15:04 +00:00
Zdenek Kabelac
34a45b0029 Fix warn message and update man page
Fix regression in man page. The chunk size is in kilobyte units on command line
input though in the source code we work with sector size unit
so make it clear in the man page.

Update chunksize for thin pool in man page - it's max value is 1024M == 1G.

Fix warning range message to show proper max value.
2012-03-06 09:22:02 +00:00
Alasdair Kergon
fa25bdc3ef close ] 2012-03-06 03:11:13 +00:00
Alasdair Kergon
ea44a7d759 Adjust wording 2012-03-06 02:42:31 +00:00
Alasdair Kergon
b343d75a5a Switch pvscan --cache major:minor to --major --minor. 2012-03-06 02:30:49 +00:00
Zdenek Kabelac
aeaec150c0 Some more missing supposedly 64bit operations.
Avoid use 32bit math for extent_size.
2012-03-05 15:05:24 +00:00
Zdenek Kabelac
90423c1200 Fit thin pool metadata into 128MB
If the lvcreate may decide some automagical values for a user,
try to keep the pool metadata size into 128MB range for optimal
perfomance (as suggested by Joe).

So if the pool metadata size and chunk_size were not specified,
try to select such values they would fit into 128MB size.
2012-03-05 14:19:13 +00:00
Peter Rajnoha
ba428469e6 Check for multiple mangled names in auto mangling mode.
Auto mode can't deal with multiple mangled names. We can do that while working
in hex mode, but in auto mode, this would lead to device name ambiguity.
2012-03-05 12:48:12 +00:00
Zdenek Kabelac
98c92abf4e Add FIXMEs
Processing loop needs some thinking
2012-03-04 15:58:31 +00:00
Alasdair Kergon
35216ca66c Scan all devices for lvmetad if 'pvscan --cache' used without device list. 2012-03-03 18:32:53 +00:00
Alasdair Kergon
59a5361fc4 Obtain VG list from lvmetad before relying on get_vgs, otherwise PVs in VGs
don't appear.
2012-03-03 17:12:21 +00:00
Alasdair Kergon
113f2a0113 Reinstate accidentally-deleted line. 2012-03-03 17:03:20 +00:00
Zdenek Kabelac
79c42c6600 Merge metadata size checking
Move the code for poolmetadatasize operation into one place.
Report override for minimum and maximum size.
Drop _read_thin_params function its error reporting is handled elsewhere.
2012-03-02 20:18:25 +00:00
Alasdair Kergon
d742cdf327 Change pvscan --lvmetad to pvscan --cache. 2012-03-02 18:09:46 +00:00
Zdenek Kabelac
1babf24949 Fix estimation of pool metadata device size
If no size was give the later added minimal size check efectively
disable this code. Also the argument for size now must be kept
in sector_size, so adding division by SECTOR_SIZE (moved into
a const expression)
2012-03-02 17:25:21 +00:00
Alasdair Kergon
d06f64dd29 Allow multiple device names with pvscan --lvmetad.
Hold global lock in pvscan --lvmetad.  (This might need refinement.)
Add PV name to "PV gone" messages.
Adjust some log message severities.  (More changes needed.)
2012-03-02 16:58:41 +00:00
Alasdair Kergon
b804340f01 Reinstate error if e.g. daemon comms fails. 2012-03-02 02:55:45 +00:00
Zdenek Kabelac
6ddce3b6a7 Check for error from dup2
Do not take correct fd as error result.
2012-03-01 23:20:45 +00:00
Zdenek Kabelac
d2ebc1dfa0 Add some more pointer validation
Ensure _display_name() and _add_dep() would not deref NULL names.
Switch to use internal dm_basename().
2012-03-01 21:56:44 +00:00
Zdenek Kabelac
52f76a7682 Test alloc fail 2012-03-01 21:49:32 +00:00
Zdenek Kabelac
0ab5e0e280 Replace goto with just log_debug
FIXME: temporal quick hack to make things green
There might be a better reaction.
2012-03-01 21:46:31 +00:00
Zdenek Kabelac
1281a5e3d5 Check for alloc error
Simplify segtype_str usage and check for NULL segtype.
2012-03-01 21:21:54 +00:00
Zdenek Kabelac
bead3fc2c0 Log sys errors 2012-03-01 21:17:29 +00:00
Zdenek Kabelac
de3692152f Backtrace for failing drop_cached_metadata 2012-03-01 21:16:44 +00:00
Zdenek Kabelac
f3c177312f Correct enum type
Using debug_t and some forgetten alloc_policy_t, force_t from past commit.
2012-03-01 21:14:43 +00:00
Zdenek Kabelac
c452307543 Few more close and dev_close trace
Adding (void) where we cannot really report an error.
2012-03-01 21:12:37 +00:00
Alasdair Kergon
7126d8c21b Reflect new file locations, include file updates etc. 2012-02-28 18:35:04 +00:00
Alasdair Kergon
dc9ef7a028 Check return values after calling new lvmetad fns
(Haven't checked error path handling though)
2012-02-28 18:08:08 +00:00
Zdenek Kabelac
fbf6b89a84 Using enum types for enums
alloc_policy_t, dm_string_mangling_t, percent_range_t, sign_t
2012-02-28 14:24:57 +00:00
Zdenek Kabelac
6f8bd07b40 Duplicate standard in/out descriptors for daemon
Addressing somewhat tricky bug here.
Since stdin,stdout,stderr were closed it's been occasionally possible to
see some unexpected messages to be flowing into a clvmd and generating some
randomly sized allocation of many megabytes. Since the message was not
being generated by standard send_message() construction, after some more
testing it apperead to be a debug log message - thus something has flown
to local socket opened on strandard out descriptor.

To fix the issue - use standard file descriptor duplication code for daemons.

For making easier debugging of polling daemon - developer might want to recompile
without modifition of standard file descriptors.
2012-02-28 10:06:53 +00:00
Zdenek Kabelac
8918bf2430 Add some log_sys_errors to close() call 2012-02-27 11:28:47 +00:00
Zdenek Kabelac
6fa41e8a21 Make force_t enum usage obvious 2012-02-27 10:06:58 +00:00
Zdenek Kabelac
24d39aa142 Always check result of _set_vg_name() 2012-02-27 10:00:23 +00:00
Zdenek Kabelac
980cf7959c Keep same sign for 's' counter 2012-02-23 22:36:56 +00:00
Jonathan Earl Brassow
870762d8e3 Require number of stripes to be greater than parity devices in higher RAID.
Also, add some comments to code that I recently added that may be unclear
otherwise.
2012-02-23 17:36:35 +00:00
Petr Rockai
dae0822698 The lvmetad client-side integration. Only active when use_lvmetad = 1 is set in
lvm.conf *and* lvmetad is running.
2012-02-23 13:11:07 +00:00
Jonathan Earl Brassow
e8eb64c878 Allow 'lvconvert --repair' to operate on RAID 4/5/6.
The higher level RAIDs should be allowed for repair along with 'mirror' and
'raid1' segment types.
2012-02-22 17:18:49 +00:00
Jonathan Earl Brassow
7a5a5cb06f Add some messages that indicate completion of RAID device replacement.
There were no messages printed upon completiion of RAID device replacement.
This could cause confusion/concern during automated recovery, because the
user sees the failure messages but no other messages indicating correction.
2012-02-22 16:03:55 +00:00
Jonathan Earl Brassow
972282bfbc Fix a bad return code in 'lvconvert_raid'
Functions at this level do return 0 or 1, not ECMD_* values.
2012-02-22 15:20:50 +00:00
Zdenek Kabelac
d81498a824 Initialize dmeventd monitoring for every command
Read lvm.conf setting for monitoring for each command. So we should not
activate monitoring if the default compilation is set to monitor during
lvconvert commnads.

Patch also removes check for  clustered VG and allows to disable monitoring
for clustered VG with the assumption, the problem with monitoring and dmeventd
flag passing for INGNORE is already fixed.
2012-02-15 15:18:43 +00:00
Zdenek Kabelac
ea7b3d8fd7 Simplify with dm_strdup 2012-02-15 14:27:53 +00:00
Peter Rajnoha
da3a375f7a Fix segfault in dmsetup when using table specification with --table.
Segfault introduced with the patch that added dm_free(_table) at the
end of dmsetup (in this release).
2012-02-15 14:20:59 +00:00
Petr Rockai
616c6208aa Turn a warning to an error in vgreduce --removemissing, since we exit with a
failure status there.
2012-02-15 12:30:46 +00:00
Peter Rajnoha
4491acea0b Add mangle command to dmsetup to provide renaming to correct mangled form. 2012-02-15 12:08:57 +00:00
Peter Rajnoha
d4aa0496fb Add 'mangled_name' and 'unmangled_name' fields to dmsetup info -c -o. 2012-02-15 12:06:17 +00:00
Peter Rajnoha
0f49ede3b1 Add --manglename option to dmsetup to select the name mangling mode. 2012-02-15 12:02:58 +00:00
Jonathan Earl Brassow
96f82296ae Change confusing message that is printed when a RAID device fails.
s/Issue/Use/, otherwise it is easy to misread "Issue" as "Issuing" - causing
the user confusion as to whether the action was performed automatically or
whether they need to issue the command.
2012-02-13 18:38:36 +00:00
Jonathan Earl Brassow
1456c3b298 Fix possible NULL pointer dereferences when updating mirror log.
'_lv_update_log_type' takes a lvconvert_params argument so that it can pass
down the user's preference of 'region_size' and allocation_policy.  When
'mirror_remove_missing' was introduced (commit ID
95986e42a1) it didn't make sense to pass down
user preferences - so NULL was given instead.  While it may never happen in
practice, static analysis reveals that this argument could be dereferenced.
So, if the user preferences were not passed in, glean the necessary fields
from what is already set in the LV.

Reported-by: Zdenek Kabelac <zkabelac@redhat.com>
Signed-off-by: Jonathan Brassow <jbrassow@redhat.com>

(Not updating WHATSNEW for this simple clean-up.)
2012-02-13 18:36:55 +00:00
Zdenek Kabelac
424f6dc4ad Handle all succefull values from open() 2012-02-13 12:07:51 +00:00
Zdenek Kabelac
e66b3e8e3b Ensure allocated device does not leak on error path
For unimplementd canonicalize_file_name set to NULL
2012-02-13 12:06:39 +00:00
Zdenek Kabelac
73e62cdc11 Add internal error for unsupported code paths
Patch mainly helps static analyzers to better work with code paths
lvm code should never trigger.
2012-02-13 11:25:56 +00:00
Zdenek Kabelac
daaea2ef94 Add few missing allocation failures tests 2012-02-13 11:13:44 +00:00
Zdenek Kabelac
52f2f3eae4 Add free_orphan_vg
Move commod code to destroy orphan VG into free_orphan_vg() function.
Use orphan vgmem for creation of PV lists.
Remove some free_pv_fid() calls (FIXME: check all of them)
FIXME: Check whether we could merge release_vg back again for all VGs.
2012-02-13 11:03:59 +00:00
Petr Rockai
8e5f7cf3dc Move lvmcache data structures behind an API (making the structures private to
lvmcache.c). No functional change.
2012-02-10 01:28:27 +00:00
Zdenek Kabelac
462835faa0 Switch to return void
List delete cannot fail, so there is no reason to test for error.
2012-02-08 12:52:58 +00:00
Zdenek Kabelac
eae8784ae2 Remove duplicate test
Tested condition has been already evaluated before
For strlen() code has already excluded <ID_LEN.
For repairing, already tested (!argc && !repairing) before.
2012-02-08 11:41:18 +00:00
Zdenek Kabelac
d75c5f06f0 Replace snprintf with dm_snprintf
snprintf testing for negative is replaced with dm_snprintf where this
test really works.
Add missing test for result of dm_snprintf().
2012-02-08 11:40:02 +00:00
Zdenek Kabelac
a6292f2a6d Remove unneeded assignments
Variables have (or will have) those values set.
2012-02-08 11:36:18 +00:00
Zdenek Kabelac
5dfd775384 Ensure strncpy() function always ends with '\0'
Since last character needs to be \0 for string,
pass buffer size smaller by 1 byte.
2012-02-08 11:05:04 +00:00
Zdenek Kabelac
cd4c26a27f Set status for error path
Do not leave status unitialized, since in some cases, it's tested,
when the function returns error.
2012-02-08 10:56:17 +00:00
Alasdair Kergon
f2e3d659ea lp.pool may be (null) too 2012-02-01 01:54:20 +00:00
Zdenek Kabelac
b39b36eeb5 Cosmetic change use return macro with implicit stack 2012-01-25 22:38:40 +00:00
Zdenek Kabelac
254944d890 Set to a defined value vars used after error path
Static analyzer noticed this vars are used even when error is reported
back thus their state is undefined - set to 0 for this case.
2012-01-25 22:20:11 +00:00
Zdenek Kabelac
1ef10bd81a Limit alignment to 32bit values
to get the same behavior on 32/64 machines.
2012-01-25 21:52:53 +00:00
Mike Snitzer
27e21a4adc Allow removal of an invalid snapshot that was to be merged on next activation.
Don't allow a user to merge an invalid snapshot.
2012-01-20 22:03:48 +00:00
Mike Snitzer
23e34c729b Differentiate between snapshot status of "Invalid" and "Merge failed". 2012-01-20 22:02:04 +00:00
Zdenek Kabelac
9a471aea06 Tiny cleanup
Just remove double braces from conditions when they are not really needed.
(So it doesn't look like an assignment and comparison).
2012-01-20 10:58:17 +00:00
Zdenek Kabelac
6336898318 Thin updated support for thin pool percent
Support to check also for metadata percent
(By checking whether seg pointer is set)
2012-01-19 15:25:37 +00:00
Alasdair Kergon
8a35706cb1 Add dmsetup 'wipe_table' to replace table with one that uses error target. 2012-01-18 18:52:02 +00:00
Peter Rajnoha
e33fd978a8 Support different device name types on output of dmsetup deps, ls and info -c command.
Add 'blkdevname' and 'blkdevs_used' field to dmsetup info -c -o.
Add 'blkdevname' option to dmsetup ls --tree to see block device names.
Add '-o options' to dmsetup deps and ls to select device name type on output.
2012-01-11 12:46:19 +00:00
Zdenek Kabelac
7afa7b079c Check for error code in _adjust_policy_params
If error is detected in _adjust_policy_params, break further command processing.
2012-01-09 12:31:52 +00:00
Zdenek Kabelac
4fbde0143a Support rounding of percentage upward
We want to keep this logic -
when LV is extend - extend the LV by at least given amount,
when LV is reduced - reduce the LV by at most given amount.

So for this the rounding needs to be used.
Current logic which seems to satisfy give rule is to round up all
extent values for LV resize upward except for values with '-' sign
that are round downward.

This patch also fixes the problem when  lvextend --use-polices tried
to extend LV the by i.e. 20% - but the resulting 20% were smaller
the extent size thus before this patch no extension happened.
2012-01-05 15:38:18 +00:00
Zdenek Kabelac
0e0f706f2e Thin automatic policy based extension 2011-12-21 13:10:52 +00:00
Zdenek Kabelac
f582793f1b Thin rename internal thin pool segment
Use matching name as kernel target - useful when function like
_percent is using this for validation.
2011-12-21 12:54:19 +00:00
Petr Rockai
11e520256b Move dm_config_write out of libdm, back to lib/config, as config_write. 2011-12-11 23:18:20 +00:00
Alasdair Kergon
594753751a Only use built-in stack size in clvmd - ignore lvm.conf. 2011-12-08 21:24:08 +00:00
Alasdair Kergon
7a5b7def16 reinstate !first_time check
(recovery from first_time failure would need different code)
2011-12-08 18:06:33 +00:00
Alasdair Kergon
909bf00ab4 tag uninit var 2011-12-08 18:00:03 +00:00
Jonathan Earl Brassow
d098140177 Add policy based automated repair of RAID logical volumes
The RAID plug-in for dmeventd now calls 'lvconvert --repair' to address failures
of devices in a RAID logical volume.  The action taken can be either to "warn"
or "allocate" a new device from any spares that may be available in the
volume group.  The action is designated by setting 'raid_fault_policy' in
lvm.conf - the default being "warn".
2011-12-06 19:30:15 +00:00
Alasdair Kergon
bc5fe20e33 update old comment 2011-12-01 14:57:30 +00:00
Jonathan Earl Brassow
d34991ed97 Don't allow size change of RAID LV that is tracking changes for a split image
Don't allow size change of RAID sub-LVs independently
2011-12-01 00:13:16 +00:00
Jonathan Earl Brassow
a927e401f1 Do not allow users to change the name of RAID sub-LVs or the name of the
RAID LV if it is tracking changes for a split image.
2011-12-01 00:09:34 +00:00
Jonathan Earl Brassow
73d6bf290e Do not allow users to change permissions on RAID sub-LVs. 2011-12-01 00:04:21 +00:00
Jonathan Earl Brassow
0c506d9a40 Support the ability to replace specific devices in a RAID array.
RAID is not like traditional LVM mirroring.  LVM mirroring required failed
devices to be removed or the logical volume would simply hang.  RAID arrays can
keep on running with failed devices.  In fact, for RAID types other than RAID1,
removing a device would mean substituting an error target or converting to a
lower level RAID (e.g. RAID6 -> RAID5, or RAID4/5 to RAID0).  Therefore, rather
than removing a failed device unconditionally and potentially allocating a
replacement, RAID allows the user to "replace" a device with a new one.  This
approach is a 1-step solution vs the current 2-step solution.

example> lvconvert --replace <dev_to_remove> vg/lv [possible_replacement_PVs]

'--replace' can be specified more than once.

example> lvconvert --replace /dev/sdb1 --replace /dev/sdc1 vg/lv
2011-11-30 02:02:10 +00:00
Zdenek Kabelac
e8a40f6571 Allow to activate snapshot
Add extra code to active and deactivate related
snapshots and origin when user specifies snapshot
logical volume as lvchange parameter.

Before patch:

$> lvs -a
  LV    VG   Attr     LSize  Pool Origin Snap%  Move Log Copy%  Convert
  lvol0 mvg  owi-a-s-  1.00k
  lvol1 mvg  swi-a-s- 16.00k      lvol0    0.00
  lvol2 mvg  swi-a-s- 16.00k      lvol0    0.00

$> lvchange -an mvg/lvol2; echo $?
  Can't change snapshot logical volume "lvol2".
5

After patch:

$> lvchange -an mvg/lvol2
Change of snapshot lvol2 will also change its origin lvol0 and 1 other
snapshot(s). Proceed? [y/n]: n
  Logical volume lvol2 not changed.

$> lvchange -y -an mvg/lvol2; echo $?
0

$> lvs -a
  LV    VG   Attr     LSize  Pool Origin Snap%  Move Log Copy%  Convert
  lvol0 mvg  owi---s-  1.00k
  lvol1 mvg  swi---s- 16.00k      lvol0
  lvol2 mvg  swi---s- 16.00k      lvol0
2011-11-18 19:22:49 +00:00
Zdenek Kabelac
e858ac1546 Skip non-virtual snapshots for availability
Change the behavior of availability change.
With this patch the lvgchange returns success
when VG is properly changed.

It skips non-virtual origins from being changes when
only 'vg' is specified as lvchange -a parameter.

Before this change we had this:

$> lvs -a
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi-a-s- 128.00k
  lvol1 mvg  owi-a-s- 128.00k
  lvol2 mvg  swi-a-s-   1.25m      lvol0
  lvol3 mvg  swi-a-s-   1.25m      lvol1

$> lvchange -an mvg ; echo $?
  Can't change snapshot logical volume "lvol2".
  Can't change snapshot logical volume "lvol3".
5

$> lvs -a
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi---s- 128.00k
  lvol1 mvg  owi---s- 128.00k
  lvol2 mvg  swi---s-   1.25m      lvol0
  lvol3 mvg  swi---s-   1.25m      lvol1

$> lvchange -ay mvg ; echo $?
  Can't change snapshot logical volume "lvol2".
  Can't change snapshot logical volume "lvol3".
5

$> lvs
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi-a-s- 128.00k
  lvol1 mvg  owi-a-s- 128.00k
  lvol2 mvg  swi-a-s-   1.25m      lvol0
  lvol3 mvg  swi-a-s-   1.25m      lvol1

After commit:

$> lvs -a
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi-a-s- 128.00k
  lvol1 mvg  owi-a-s- 128.00k
  lvol2 mvg  swi-a-s-   1.25m      lvol0
  lvol3 mvg  swi-a-s-   1.25m      lvol1

$> lvchange -an mvg ; echo $?
0

$> lvs -a
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi---s- 128.00k
  lvol1 mvg  owi---s- 128.00k
  lvol2 mvg  swi---s-   1.25m      lvol0
  lvol3 mvg  swi---s-   1.25m      lvol1

$> lvchange -ay mvg ; echo $?
0

$> lvs -a
  LV    VG   Attr     LSize   Pool Origin
  lvol0 mvg  owi-a-s- 128.00k
  lvol1 mvg  owi-a-s- 128.00k
  lvol2 mvg  swi-a-s-   1.25m      lvol0
  lvol3 mvg  swi-a-s-   1.25m      lvol1
2011-11-18 19:19:22 +00:00
Alasdair Kergon
bf09a32006 Make dmsetup.static and lvm.static build when dmeventd is disabled.
udev may also need to be disabled if you didn't build it statically too.

dmeventd.static could be fixed with some more work but I don't really see the
point: without dlopen() it's useless, and if you have dlopen(), why not support
normal shared libraries too?
2011-11-14 21:30:35 +00:00
Zdenek Kabelac
6744c143a5 Thin remove unused define
Remove DM_THIN_ERROR_DEVICE_ID from API.
Remove API warning.
Drop code that was using DM_THIN_ERROR_DEVICE_ID (already commented)
Remove debug message which slipped in through some previous commit.
2011-11-12 22:44:10 +00:00
Zdenek Kabelac
6e89eb9a52 Small comment and indent updates 2011-11-10 12:43:05 +00:00
Zdenek Kabelac
a538e369db Thin move _read_activation_params check
Since we finaly recognize thin creation only after
_determine_snapshot_type() - move _read_activation_params()
after it - so we can support  lvcreate -an thin snapshot.
2011-11-10 12:40:29 +00:00
Zdenek Kabelac
95308c5f58 Thin create normal (old) snapshot when size is specified 2011-11-10 12:39:46 +00:00
Zdenek Kabelac
6b58c79603 Thin ensure pool table is update after resize
Always make sure table gets reloaded.
For now activate and deactivate pool volume if it's not active.

FIXME: we could do this only if we are sure some thin volume is alive.
2011-11-08 12:19:53 +00:00
Zdenek Kabelac
97d7e5aedb Thin supports snapshots
Full support for thin snapshots.
Create and remove is supported.

TODO: lvconvert support is not yes available.
2011-11-07 11:03:47 +00:00
Zdenek Kabelac
e903e37d0a Add missing default LVM_VG_NAME
Add support for exported shell variable LVM_VG_NAME also
for thins and snapshots.
2011-11-07 11:01:53 +00:00
Zdenek Kabelac
87371d48cc Thin revert code for exclusive pool activation
There are no limits on thin-pool activation now.
Revert code that is no longer needed.
2011-11-07 10:58:13 +00:00
Zdenek Kabelac
4079a8f298 Avoid lvextend to overflow
Add extra check to extent_count overflow.
Use internal define MAX_EXTENT_COUNT instead UINT32_MAX.
2011-11-04 22:49:53 +00:00
Zdenek Kabelac
b8cac455bd Thin supports poolmetadatasize setting
Add option to set pool metadatasize.
For passing size parameter reuse region_size.
2011-11-04 22:43:10 +00:00
Zdenek Kabelac
267a575768 Thin removing limitation on activation of pool device.
Since activation of pool is now independent on thin activation,
user may do whatever he needs - thought preferable thin should stay alive,
but it it will be found inactivate, update_pool will bring the pool up.
2011-11-03 14:59:20 +00:00
Zdenek Kabelac
f8aee4460a Thin avoids need of having writable VG for activation 2011-11-03 14:41:18 +00:00
Zdenek Kabelac
7654abc26f Thin creation without activation
All thins are created with the next activation and VG is updated
without messages. Only some basic commands works.
(i.e. lvcreate -an  -V10 -T mvg/pool)
There can be some combination to confuse this system.

This functionality for snapshots is going to be interesting.
2011-10-30 22:07:38 +00:00
Zdenek Kabelac
daa10ad0fd Thin pool resize support for data LV
Support for extension of pool data LV.

TODO: figure out thin volume for suspend/resume in cluster.
2011-10-28 20:31:01 +00:00
Zdenek Kabelac
ed32476c67 Thin works only with exclusive activation
Enforce exclusive activation with thin targets.
2011-10-28 20:29:06 +00:00
Zdenek Kabelac
a1d5aaf725 Thin pool activation change
To ensure we properly handle LV cluster locking - explicitely do
not allow to change the availability of the thin pool that is in use
for some thin LV.

As soon as the thin volume is created the only way to activate pool
is via implicit dependency.

Ignore thinpool open count for lv/vgchange operations.
2011-10-28 20:28:00 +00:00
Zdenek Kabelac
c35bcc8bdf Ensure thin LVs take an exclusive activation 2011-10-22 16:47:23 +00:00
Zdenek Kabelac
3bc417488d Thin pool now support chunk size as well
Use chunksize option to specify data_block_size for thin pool target.
Drop low_water_mark to zero.
2011-10-21 09:55:07 +00:00
Petr Rockai
61cf772e70 Keep the LVM-based dmeventd plugins from trying to manipulate the dmeventd
monitoring state of the logical volumes they are currently acting on.

Until now, every time a logical volume has been changed by a dmeventd plugin,
this plugin would have called back to dmeventd through the external FIFO
mechanism. I am fairly sure this was superfluous, inefficient and possibly even
dangerous.
2011-10-19 08:46:26 +00:00
Jonathan Earl Brassow
dc0582ce0a Fix bad lvconvert help output.
The '--merge' option to lvconvert works on snapshots and RAID1.  The man
pages correctly reflect this, but the CLI help output still used the term,
'SnapshotLogicalVolume'.
2011-10-18 16:27:45 +00:00
Zdenek Kabelac
a4c1c0d26f Remove test for first_time with FIXME
Workaround for the current code with big FIXME,
since proper solution for pvmove needs to be developed.

Commiting this only for the purpose to get cluster testing covered.
2011-10-11 08:51:02 +00:00
Jonathan Earl Brassow
f60175c308 Add the ability to convert LVs of "mirror" segtype to "raid1" segtype.
Example:
~> lvconvert --type raid1 vg/mirror_lv

Steps to convert "mirror" to "raid1"
1) Allocate a RAID metadata LV for each mirror image from the same PVs
   on which they are located.
2) Clear the metadata LVs.  This involves writing LVM metadata, so we don't
   change any aspects of the mirror LV before this so that the user can easily
   remove LVs from the failed convert attempt while retaining the original
   mirror.
3) Remove the mirror log, if it exists.
4) Add metadata LVs to mirror LV
5) Rename mirror sub-lvs (s/mimage/rimage/)
6) Change flags and segtype from mirror to raid1
2011-10-07 14:56:01 +00:00
Jonathan Earl Brassow
d3582e0252 Add the ability to convert linear LVs to RAID1
Example:
~> lvconvert --type raid1 -m 1 vg/lv

The following steps are performed to convert linear to RAID1:
1) Allocate a metadata device from the same PV as the linear device
   to provide the metadata/data LV pair required for all RAID components.
2) Allocate the required number of metadata/data LV pairs for the
   remaining additional images.
3) Clear the metadata LVs.  This performs a LVM metadata update.
4) Create the top-level RAID LV and add the component devices.

We want to make any failure easy to unwind.  This is why we don't create the
top-level LV and add the components until the last step.  Should anything
happen before that, the user could simply remove the unnecessary images.  Also,
we want to ensure that the metadata LVs are cleared before forming the array to
prevent stale information from polluting the new array.

A new macro 'seg_is_linear' was added to allow us to distinguish linear LVs
from striped LVs.
2011-10-07 14:52:26 +00:00
Jonathan Earl Brassow
a80192b6a7 Allow 'nosync' extension of mirrors.
This patch allows a mirror to be extended without an initial resync of the
extended portion.  It compliments the existing '--nosync' option to lvcreate.
This action can be done implicitly if the mirror was created with the '--nosync'
option, or explicitly if the '--nosync' option is used when extending the device.

Here are the operational criteria:
1) A mirror created with '--nosync' should extend with 'nosync' implicitly
[EXAMPLE]# lvs vg; lvextend -L +5G vg/lv ; lvs vg
  LV   VG   Attr     LSize Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   Mwi-a-m- 5.00g                         lv_mlog 100.00
  Extending 2 mirror images.
  Extending logical volume lv to 10.00 GiB
  Logical volume lv successfully resized
  LV   VG   Attr     LSize  Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   Mwi-a-m- 10.00g                         lv_mlog 100.00

2) The 'M' attribute ('M' signifies a mirror created with '--nosync', while 'm'
signifies a mirror created w/o '--nosync') must be preserved when extending a
mirror created with '--nosync'.  See #1 for example of 'M' attribute.

3) A mirror created without '--nosync' should extend with 'nosync' only when
'--nosync' is explicitly used when extending.
[EXAMPLE]# lvs vg; lvextend -L +5G vg/lv; lvs vg
  LV   VG   Attr     LSize  Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   mwi-a-m- 20.00m                         lv_mlog 100.00
  Extending 2 mirror images.
  Extending logical volume lv to 5.02 GiB
  Logical volume lv successfully resized
  LV   VG   Attr     LSize Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   mwi-a-m- 5.02g                         lv_mlog   0.39
vs.
[EXAMPLE]# lvs vg; lvextend -L +5G vg/lv --nosync; lvs vg
  LV   VG   Attr     LSize  Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   mwi-a-m- 20.00m                         lv_mlog 100.00
  Extending 2 mirror images.
  Extending logical volume lv to 5.02 GiB
  Logical volume lv successfully resized
  LV   VG   Attr     LSize Pool Origin Snap%  Move Log     Copy%  Convert
  lv   vg   Mwi-a-m- 5.02g                         lv_mlog 100.00

4) The 'm' attribute must change to 'M' when extending a mirror created without
'--nosync' is extended with the '--nosync' option.  (See #3 examples above.)

5) An inactive mirror's sync percent cannot be determined definitively, so it
must not be allowed to skip resync.  Instead, the extend should ask the user if
they want to extend while performing a resync.
[EXAMPLE]# lvchange -an vg/lv
[EXAMPLE]# lvextend -L +5G vg/lv
  Extending 2 mirror images.
  Extending logical volume lv to 10.00 GiB
  vg/lv is not active.  Unable to get sync percent.
Do full resync of extended portion of vg/lv?  [y/n]: y
  Logical volume lv successfully resized

6) A mirror that is performing recovery (as opposed to an initial sync) - like
after a failure - is not allowed to extend with either an implicit or
explicit nosync option.  [You can simulate this with a 'corelog' mirror because
when it is reactivated, it must be recovered every time.]
[EXAMPLE]# lvcreate -m1 -L 5G -n lv vg --nosync --corelog
  WARNING: New mirror won't be synchronised. Don't read what you didn't write!
  Logical volume "lv" created
[EXAMPLE]# lvs vg
  LV   VG   Attr     LSize Pool Origin Snap%  Move Log Copy%  Convert
  lv   vg   Mwi-a-m- 5.00g                             100.00
[EXAMPLE]# lvchange -an vg/lv; lvchange -ay vg/lv; lvs vg
  LV   VG   Attr     LSize Pool Origin Snap%  Move Log Copy%  Convert
  lv   vg   Mwi-a-m- 5.00g                               0.08
[EXAMPLE]# lvextend -L +5G vg/lv
  Extending 2 mirror images.
  Extending logical volume lv to 10.00 GiB
  vg/lv cannot be extended while it is recovering.

7) If 'no' is selected in #5 or if the condition in #6 is hit, it should not
result in the mirror being resized or the 'm/M' attribute being changed.


NOTE:  A mirror created with '--nosync' behaves differently than one created
without it when performing an extension.  The former cannot be extended when
the mirror is recovering (unless in-active), while the latter can.  This is
a reasonable thing to do since recovery of a mirror doesn't take long (at
least in the case of an on-disk log) and it would cause far more time in
degraded mode if the extension w/o '--nosync' was allowed.  It might be
reasonable to add the ability to force the operation in the future.  This
should /not/ force a nosync extension, but rather force a sync'ed extension.
IOW, the user would be saying, "Yes, yes... I know recovery won't take long
and that I'll be adding significantly to the time spent in degraded mode, but
I need the extra space right now!".
2011-10-06 15:32:26 +00:00
Jonathan Earl Brassow
a391248427 Fix vgsplit when there are mirrors that have mirrored logs.
The problem as reported by "ben <benscott@nwlink.com>" on lvm-devel:

vgsplit fails with mirrored mirror log

#lvs --all -o lv_name,lv_attr,devices
LV                       Attr   Devices
MyMirror                 mwi--
[MyMirror_mimage_0]      Iwi--- /dev/sdq(0)
[MyMirror_mimage_1]      Iwi--- /dev/sdo(0)
[MyMirror_mimage_2]      Iwi--- /dev/sdi(0)
[MyMirror_mlog]          mwi---
[MyMirror_mlog_mimage_0] Iwi--- /dev/sds(0)
[MyMirror_mlog_mimage_1] Iwi--- /dev/sde(0)

#vgsplit -v "TestA" "TestB" "/dev/sdq" "/dev/sdo" "/dev/sdi" "/dev/sds"
"/dev/sde"
  Checking for volume group "TestA"
  Checking for new volume group "TestB"
  Archiving volume group "TestA" metadata (seqno 213).
Can't split mirror MyMirror between two Volume Groups

AFTER FIX:

[root@bp-01 ~]# lvs -a -o name,vg_name,devices vg new
  Volume group "new" not found
  Skipping volume group new
  LV                 VG   Devices
  lv                 vg   lv_mimage_0(0),lv_mimage_1(0)
  [lv_mimage_0]      vg   /dev/sdb1(0)
  [lv_mimage_1]      vg   /dev/sdc1(0)
  [lv_mlog]          vg   lv_mlog_mimage_0(0),lv_mlog_mimage_1(0)
  [lv_mlog_mimage_0] vg   /dev/sdh1(0)
  [lv_mlog_mimage_1] vg   /dev/sdi1(0)
[root@bp-01 ~]# vgsplit vg new /dev/sd[bchi]1
  New volume group "new" successfully split from "vg"
[root@bp-01 ~]# lvs -a -o name,vg_name,devices vg new
  LV                 VG   Devices
  lv                 new  lv_mimage_0(0),lv_mimage_1(0)
  [lv_mimage_0]      new  /dev/sdb1(0)
  [lv_mimage_1]      new  /dev/sdc1(0)
  [lv_mlog]          new  lv_mlog_mimage_0(0),lv_mlog_mimage_1(0)
  [lv_mlog_mimage_0] new  /dev/sdh1(0)
  [lv_mlog_mimage_1] new  /dev/sdi1(0)
2011-10-06 14:17:45 +00:00
Alasdair Kergon
10d0d9c7c4 Introduce revert_lv for better pvmove cleanup.
(One further fix needed to remove the stray pvmove LVs left behind.)
2011-09-27 22:43:40 +00:00
Alasdair Kergon
74e72bd75d Replace incomplete pvmove activation failure recovery code with a message.
As it stands, the recovery code can make things worse sometimes so it's
better to insist on a proper 'pvmove --abort' cleanup.
2011-09-27 17:29:33 +00:00
Alasdair Kergon
1c26860d82 Abort if _finish_pvmove suspend_lvs fails instead of cleaning up incompletely.
Change suspend_lvs to call vg_revert internally.
Change vg_revert to void and remove superfluous calls after failed vg_commit.
2011-09-27 17:09:42 +00:00
Alasdair Kergon
0ed2af7fb1 better -m0 error message, but there's an internal logic error to fix instead 2011-09-27 12:37:07 +00:00
Zdenek Kabelac
9e5486bb65 Drop cleanup of .exported_symbols_generated in DISTCLEAN_TARGETS
Makefile cosmetics - since .exported_symbols_generated in cleardir:
target via make.tmpl, there is no need to set them in DISTCLEAN_TARGETS.
2011-09-24 21:00:52 +00:00
Peter Rajnoha
047e4cd2f5 Add --retry option for dmsetup remove to retry removal if not successful. 2011-09-22 17:12:28 +00:00
Jonathan Earl Brassow
f989a55539 Disallow the creation of mirrors (mirror or raid1 segtype) with only one leg.
If you specify the segment type (e.g. --type mirror) and the mirrors argument
as zero, it would result in a mirrored LV with only one image.  While the device
may be valid in theory, it should not be allowed in practice.  It also makes it
difficult on the conversion tools, since they react badly to single-image
mirrors.
2011-09-22 15:36:21 +00:00
Alasdair Kergon
a944480b9b FIXMEs to note problems with some error paths. (Perhaps safer to disable
them until they can be fixed completely?)
2011-09-21 16:36:39 +00:00
Zdenek Kabelac
da1350d420 Add missing log_error() to lvresize command when fsadm tool fails
Also add test case
2011-09-21 10:39:47 +00:00
Zdenek Kabelac
bf93b4ddfe Fix command line option decoding
LVM has huge set of options now - it's approaching 60 short-arg less options
and we get interesting case of misdetection for 'merge' option which has been
put into the middle of options with 'short_arg' - thus certainly past 65. (ASCII 'A').

To avoid confusion of short_arg with long_opt number - add  '128' to all such
non-short-arg options.
2011-09-16 12:10:02 +00:00
Petr Rockai
44dfb51f2a When resizing LVs, always round in the safe direction, regardless of whether we
were called as lvresize or lvreduce.
2011-09-15 18:51:11 +00:00
Milan Broz
b18e1fd50e Fix possible overflow of size if %FREE or %VG is used.
https://bugzilla.redhat.com/show_bug.cgi?id=737087
2011-09-15 15:26:40 +00:00
Milan Broz
89880365fc Fix vgchange activation of snapshot with virtual origin. 2011-09-14 18:20:03 +00:00
Alasdair Kergon
ef78ebf35a lvcreate/remove thin_pool and thin volumes (--driverloaded n only) 2011-09-08 16:41:18 +00:00
Zdenek Kabelac
0d505fb408 Check if lp.origin exists
Currently needed for _determine_snapshot_type().
2011-09-07 09:25:51 +00:00
Zdenek Kabelac
4144938350 Support break for vgchange and vgrefresh operation
Allow to break some lengthy vgchange and vgrefresh operation.
2011-09-07 08:41:47 +00:00
Alasdair Kergon
bb6f9b10db pool attach fns & more field renaming 2011-09-06 22:43:56 +00:00
Alasdair Kergon
b88362ff95 add thin_manip.c like the other manip files
move basic lv_is_* to macros
data_lv -> pool_lv - we decided to call it 'pool' everywhere now
2011-09-06 19:25:42 +00:00
Alasdair Kergon
2ef5b7cca6 Start using 64-bit status flags - most of the code already handles them.
tdata -> tpool
remove commented out definitions from metadata.h
formatting clean-ups
2011-09-06 18:49:31 +00:00
Alasdair Kergon
e866a22916 only thin volumes need converting 2011-09-06 15:35:11 +00:00
Alasdair Kergon
9ac61d2ba2 lvcreate parsing for thin provisioning.
The rest is incomplete so this isn't usable yet.
2011-09-06 00:26:42 +00:00
Alasdair Kergon
58366c058e Remove incorrect requirement for -j or -m from lvchange error message. 2011-09-05 12:54:29 +00:00
Alasdair Kergon
c82c2bebed Move cascade inside libdm etc.
Makes dumpconfig whole-section output wrong in a different way from before,
but we should be able to merge cft_cmdline properly into cmd->cft now and
remove cascade.
2011-09-02 01:32:08 +00:00
Petr Rockai
e59e2f7c3c Move the core of the lib/config/config.c functionality into libdevmapper,
leaving behind the LVM-specific parts of the code (convenience wrappers that
handle `struct device` and `struct cmd_context`, basically). A number of
functions have been renamed (in addition to getting a dm_ prefix) -- namely,
all of the config interface now has a dm_config_ prefix.
2011-08-30 14:55:15 +00:00
Jonathan Earl Brassow
a2facf4ad4 Add ability to merge back a RAID1 image that has been split w/ --trackchanges
Argument layout is very similar to the merge command for snapshots.
2011-08-18 19:43:08 +00:00
Jonathan Earl Brassow
6d04311efa Add the ability to split an image from the mirror and track changes.
~> lvconvert --splitmirrors 1 --trackchanges vg/lv
The '--trackchanges' option allows a user the ability to use an image of
a RAID1 array for the purposes of temporary read-only access.  The image
can be merged back into the array at a later time and only the blocks that
have changed in the array since the split will be resync'ed.  This
operation can be thought of as a partial split.  The image is never completely
extracted from the array, in that the array reserves the position the device
occupied and tracks the differences between the array and the split image via
a bitmap.  The image itself is rendered read-only and the name (<LV>_rimage_*)
cannot be changed.  The user can complete the split (permanently splitting the
image from the array) by re-issuing the 'lvconvert' command without the
'--trackchanges' argument and specifying the '--name' argument.
	~> lvconvert --splitmirrors 1 --name my_split vg/lv
Merging the tracked image back into the array is done with the '--merge'
option (included in a follow-on patch).
	~> lvconvert --merge vg/lv_rimage_<n>

The internal mechanics of this are relatively simple.  The 'raid' device-
mapper target allows for the specification of an empty slot in an array
via '- -'.  This is what will be used if a partial activation of an array
is ever required.  (It would also be possible to use 'error' targets in
place of the '- -'.)  If a RAID image is found to be both read-only and
visible, then it is considered separate from the array and '- -' is used
to hold it's position in the array.  So, all that needs to be done to
temporarily split an image from the array /and/ cause the kernel target's
bitmap to track (aka "mark") changes made is to make the specified image
visible and read-only.  To merge the device back into the array, the image
needs to be returned to the read/write state of the top-level LV and made
invisible.
2011-08-18 19:38:26 +00:00
Jonathan Earl Brassow
a324baf6a1 Add --splitmirrors support for RAID1 (1 image only)
Users already have the ability to split an image from an LV of "mirror"
segtype.  This patch extends that ability to LVs of "raid1" segtype.

This patch only allows a single image to be split off, however.  (The
"mirror" segtype allows an arbitrary number of images to be split off.
e.g.  4-way => 3-way/linear, 2-way/2-way, linear,3-way)
2011-08-18 19:34:18 +00:00
Alasdair Kergon
f1c2a5af58 Add -V as short form of --virtualsize in lvcreate. 2011-08-17 15:15:36 +00:00
Alasdair Kergon
d8b1aa198b more pre-release fixes 2011-08-12 02:16:46 +00:00
Alasdair Kergon
40dbaac892 pre-release fixes incl make distclean and configure --with-raid=none/shared 2011-08-11 19:18:17 +00:00
Jonathan Earl Brassow
4aebd52c4c Add ability to down-convert RAID1 arrays.
Also, add some simple RAID tests to testsuite.
2011-08-11 18:24:40 +00:00
Milan Broz
2836eabc9e Remove dev name prefix from dmsetup line output if major and minor is used. 2011-08-11 17:06:24 +00:00
Zdenek Kabelac
077a6755ff Replace free_vg with release_vg
Move the free_vg() to  vg.c  and replace free_vg  with release_vg
and make the _free_vg internal.

Patch is needed for sharing VG in vginfo cache so the release_vg function name
is a better fit here.
2011-08-10 20:25:29 +00:00
Zdenek Kabelac
71c556f785 Add 'empty' command
Using empty command ';' here makes the code look nicer.
2011-08-04 14:54:48 +00:00
Zdenek Kabelac
6fb5fbbabf Remove self assigment which has no effect
Just a tiny code cleanup found by analyzer.
2011-08-04 14:11:28 +00:00
Zdenek Kabelac
5dfa0945cb Minor memory leak fix
Defer the test of the function return value after the string memory is released.
Otherwise in this error path the string would present memory leak.
(Thought in this case we are already out of memory...)
2011-08-04 12:40:24 +00:00
Zdenek Kabelac
33d6fe9bd0 Add missing new line in lvrename help text. 2011-08-04 10:12:44 +00:00
Jonathan Earl Brassow
cac52ca4ce Add basic RAID segment type(s) support.
Implementation described in doc/lvm2-raid.txt.

Basic support includes:
- ability to create RAID 1/4/5/6 arrays
- ability to delete RAID arrays
- ability to display RAID arrays
Notable missing features (not included in this patch):
- ability to clean-up/repair failures
- ability to convert RAID segment types
- ability to monitor RAID segment types
2011-08-02 22:07:20 +00:00
Alasdair Kergon
6585b5a197 remove unnecessary lvconvert.h 2011-07-08 19:42:11 +00:00
Alasdair Kergon
3151e0995a Remove dev name prefix from dmsetup line output if exactly one dev requested. 2011-07-08 17:08:19 +00:00
Alasdair Kergon
2243718fae Add framework for validation of ioctls. Doesn't do any checks yet.
dmsetup --checks
libdevmapper: dm_task_enable_checks()
lvm.conf: activation/checks=1
2011-07-01 14:09:19 +00:00
Alasdair Kergon
f96cf55d36 Add age filter to dmsetup udevcomplete_all to minimise concurrency problems. 2011-06-29 21:56:46 +00:00
Jonathan Earl Brassow
63576b1202 Fix error message - the parameter name is '--mirrorlog' not '--log' 2011-06-29 02:06:26 +00:00
Jonathan Earl Brassow
48c9c491b0 Remove unnecesary conditional.
The conditional is not just unnecessary, it would have been wrong.  The code
is suppose to be checking if the 'splitmirrors_ARG' is negative, but it
instead is checking 'mirrors_ARG'.  Rather than changing the argument being
checked, I've pulled the check entirely because 'splitmirrors_ARG' is already
guarenteed to not be negative by virtue of the fact that it is a 'int_arg'.
Negative values will be caught in _process_command_line().
2011-06-28 21:28:35 +00:00
Alasdair Kergon
55f83c4399 Move _set_lvm_fallback into toolcontext, fix string comparison (/devtest
matched /dev) and note that function should go anyway as it can be
overriding a valid config.
2011-06-27 23:43:04 +00:00
Alasdair Kergon
0437bccc3c Move udev_only logic inside stacked node op code.
(We still need to treat add+readhead+del as a no-op.)
Rename udev_fallback to verify_udev_operations.
Rename --udevfallback to --verifyudev
2011-06-27 21:43:58 +00:00
Peter Rajnoha
b1db4dd13e Disable udev fallback and add --udevfallback option to dmsetup. 2011-06-17 14:55:51 +00:00
Peter Rajnoha
418663b61c Disable udev fallback by default and add activation/udev_fallback to lvm.conf.
We've used udev fallback code till now to check whether udev
created/removed the entries in /dev correctly and if not,
a repair was done (giving a warning messagea about that).

This patch adds a possibility to enable this additional check
and subsequent fallback only when required (debugging purposes
mostly) and trust udev completely.

So let's disable the fallback code by default and add a new
configuration option "activation/udev_fallback".

(The original code for creating the nodes will still be used
in case the device directory that is set in lvm.conf differs
from the one that udev uses and also when activation/udev_rules
is set to 0 - otherwise we would end up with no nodes/symlinks
at all)
2011-06-17 14:50:53 +00:00
Milan Broz
6f14cd22fd Fix lvreduce stripe rounding up from previous commit. 2011-06-15 10:56:52 +00:00
Alasdair Kergon
df390f1799 Major pvmove fix to issue ioctls in the correct order when multiple LVs
are affected by the move.  (Currently it's possible for I/O to become
trapped between suspended devices amongst other problems.

The current fix was selected so as to minimise the testing surface.  I
hope eventually to replace it with a cleaner one that extends the
deptree code.

Some lvconvert scenarios still suffer from related problems.
2011-06-11 00:03:06 +00:00
Milan Broz
f4ba9c5d1e Fix mirrored stripe reduction.
Patch adds check for stripe not only in direct
LV segment but also in mirror image segment.

This prevents bugs like:

# lvcreate -i2 -l10 -n lv vg_test
# lvconvert -m1 -i1 vg_test/lv

# lvreduce -f -l1 vg_test/lv
  WARNING: Reducing active logical volume to 4.00 MiB
  THIS MAY DESTROY YOUR DATA (filesystem etc.)
  Reducing logical volume lv to 4.00 MiB
  Segment extent reduction 9 not divisible by #stripes 2
  Logical volume lv successfully resized

# lvremove -f vg_test
  Segment extent reduction 1 not divisible by #stripes 2
  LV segment lv:0-4294967295 is incorrectly listed as being used by LV lv_mimage_0
  Internal error: LV segments corrupted in lv_mimage_0.
2011-06-09 19:38:56 +00:00
Milan Broz
851b1a9606 Fix extent rounding for striped segments.
We should never remove more extents than requested by user,
so round up to next stripe boundary during lvreduce.

Also this fixes round to zero sized LV bug:

# lvcreate -i2 -I 64k -l10 -n lvs vg_test
# lvreduce -f -l1 vg_test/lvs
  Rounding size (1 extents) down to stripe boundary size for segment (0 extents)
  WARNING: Reducing active logical volume to 0
  THIS MAY DESTROY YOUR DATA (filesystem etc.)
  Reducing logical volume lvs to 0
  Failed to suspend lvs
2011-06-09 19:34:49 +00:00
Alasdair Kergon
3cac20f850 Defer writing PV labels to vg_write.
Store label_sector only in struct physical_volume.
2011-06-01 19:29:31 +00:00
Alasdair Kergon
453cdee51c Permit --available with lvcreate so non-snapshot LVs need not be activated. 2011-06-01 19:21:03 +00:00
Peter Rajnoha
1fd2dac60b Clarify error message when unable to convert an LV into a snapshot of an LV. 2011-06-01 12:24:15 +00:00
Peter Rajnoha
c08c564e21 Use new dev_open_readonly fn to prevent opening devices for read-write when not necessary.
Before, we used vg_write_lock_held call to determnine the way a device is
opened. Unfortunately, this opened many devices in RW mode when it was not
really necessary. With the OPTIONS+="watch" rule used in the udev rules,
this could fire numerous events while closing such devices (and it caused
useless scans from within udev rules in return).

A common bug we hit with this was with the lvremove command which was unable
to remove the LV since it was being opened from within the udev rules. This
patch should minimize such situations (at least with respect to LVM handling
of devices).

Though there's still a possibility someone will open a device 'outside' in
parallel and fire the event based on the watch rule when closing a device
once opened for RW.
2011-05-28 09:48:14 +00:00
Zdenek Kabelac
5ec549ca5a Do not log a superfluous stack message when the lv is properly processed 2011-05-19 13:59:22 +00:00
Petr Rockai
ed6ff5d2b3 Rewrite vgreduce --removemissing --force, using existing primitives:
lv_remove_with_dependencies and mirror_remove_missing (the latter coming from
lvconvert). Remove substantial amount of legacy code.
2011-05-07 15:52:16 +00:00
Petr Rockai
b00711e312 Add a new entry point in the mirror lvconvert code, for removing missing mirror
images and/or logs, without attempting any further actions.
2011-05-07 13:56:13 +00:00
Petr Rockai
eee66d2a80 When glibc needs buffers for line buffering of input and output buffers, it
allocates these buffers in such way it adds memory page for each such buffer
and size of unlock memory check will mismatch by 1 or 2 pages.

This happens when we print or read lines without '\n' so these buffers are
used. To avoid this extra allocation, use setvbuf to set these bufffers ahead.

Signed-off-by: Zdenek Kabelac <zkabelac@redhat.com>
Reviewed-by: Milan Broz <mbroz@redhat.com>
Reviewed-by: Petr Rockai <prockai@redhat.com>
2011-05-07 13:50:11 +00:00
Alasdair Kergon
919ab56b6d pre-release clean-ups 2011-04-29 00:21:13 +00:00
Peter Rajnoha
a1bf82a2df Use common udev_get_dev_dir() to get current device directory managed by udev. 2011-04-22 12:07:35 +00:00
Peter Rajnoha
edcda01a1e Obtain device list from udev by default if LVM2 is compiled with udev support.
Also, add a new 'obtain_device_list_from_udev' setting to lvm.conf with which
we can turn this feature on or off if needed.

If set, the cache of block device nodes with all associated symlinks
will be constructed out of the existing udev database content.
This avoids using and opening any inapplicable non-block devices or
subdirectories found in the device directory. This setting is applied
to udev-managed device directory only, other directories will be scanned
fully. LVM2 needs to be compiled with udev support for this setting to
take effect. N.B. Any device node or symlink not managed by udev in
udev directory will be ignored with this setting on.
2011-04-22 12:05:32 +00:00
Peter Rajnoha
71b29ddcc4 Require libudev >= 143 when compiling with udev support.
Old versions of libudev < 143 were experimental and unstable. Require recent
and stable versions only (version 143 is old enough anyway).
2011-04-22 11:56:41 +00:00
Zdenek Kabelac
c67d2b4dd4 Fix incorrect tests for dm_snprintf() failure
As the memory is preallocated based on arg size in these cases,
the error would be quite hard to trigger here anyway.
2011-04-09 19:05:23 +00:00
Zdenek Kabelac
a1eba521e3 Fix some unmatching sign comparation gcc warnings
Simple replacement for unsigned type - usually in for() loops.
2011-04-08 14:40:18 +00:00
Jonathan Earl Brassow
fe93c99ad9 This patch adds the ability to extend 0 length layered LVs. This
allows us to allocate all images of a mirror (or RAID array) at one
time during create.

The current mirror implementation still requires a separate allocation
for the log, however.
2011-04-06 21:32:20 +00:00
Zdenek Kabelac
91d865cab5 Fix free_vg order
As now the FID management is more complex, the code inside free_vg needs
to access some parts of memory pools which were not needed before.

For this - makes the order of unlock_and_free_vg() unconditional.
Keek using unlock_and_free_vg() API function.

For properly working VG locking mechanism only the alphabeting locking
orderer needs to be preserved.

TODO: there could be few more code parts simplified when we 'officially'
support of referencies between different memory pools.
2011-03-30 14:35:00 +00:00
Zdenek Kabelac
6076185b70 Add attribute printf 2011-03-29 21:56:53 +00:00
Zdenek Kabelac
36089b2236 Const warning fixes
With recent update of dm_report_field_string() API call to accept
completely const objects - we no longer need loose constness here
and keep it forwarding.
2011-03-29 21:49:18 +00:00
Zdenek Kabelac
f77736cab5 Remove double braces
Clang gives notice about possible confusion as commonly double bracces are
used when some assignment is done inside them.
2011-03-29 20:19:03 +00:00
Jonathan Earl Brassow
60c10a45ce s/MIRROR_NOTSYNCED/LV_NOTSYNCED/ - Flag will may refer to more than just mirrors 2011-03-29 12:51:57 +00:00
Jonathan Earl Brassow
09c4fd3f55 cosmetic change - swapping one macro for another
When I see 'seg_is_mirrored', I expect the argument to be an lv_segment.
In this case, it is lvcreate_params.  Both structures, have a 'segtype'
entry which the macro dereferences.  However, it just seems easier to
understand if we do 'segtype_is_mirrored' instead.
2011-03-25 21:56:28 +00:00
Peter Rajnoha
84f48499a3 Add new free_pv_fid fn and use it throughout to free all attached fids.
Since format instances will use own memory pool, it's necessary to properly
deallocate it. For now, only fid is deallocated. The PV structure itself
still uses cmd mempool mostly, but anytime we'd like to add a mempool
in the struct physical_volume, we can just rename this fn to free_pv and
add the code (like we have free_vg fn for VGs).
2011-03-11 14:56:56 +00:00
Alasdair Kergon
2f25c320fb Use empty string instead of /dev// for LV path when there's no VG.
Don't allocate unused VG mempool in _pvsegs_sub_single.
2011-03-09 12:44:42 +00:00
Milan Broz
be3510b204 PE size overflows, on most architectures it is catch by "PE cannot be 0"
but s390x unfortunately return something usable.

Always use unit64 in inital parameter check.
2011-03-02 20:00:09 +00:00
Milan Broz
301c2b8822 Use 64bit unsigned value for maximum stripe size test.
While STRIPE_SIZE_LIMIT * 2 is basically UINT_MAX, 32bit integer
value can already overflow durin arg size parsing.

(This really happens in test where --stripesize 4294967291 is used,
in s390x uint overflow and this test is ineffective.)
2011-03-02 16:56:06 +00:00
Alasdair Kergon
11bffd7d25 Accept multiple mapped device names on many dmsetup command lines. 2011-03-02 02:44:56 +00:00
Alasdair Kergon
d0e3d474d1 Fix dm_udev_wait calls in dmsetup to occur before readahead display not after.
Include an implicit dm_task_update_nodes() within dm_udev_wait().
2011-03-02 00:29:57 +00:00