IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
When creating LV - in some case we change created segment type
(ATM for cache and snapshot) and we then manipulate with
lv segment according to 'lp' segtype.
Fix this by checking for proper type before accessing segment members.
This makes command like:
lvcreate --type cache-pool -L10 vg/cpool
lvcreate -H -L10 --cachesettings migtation_threshold=10000 vg/cpool
to pass since now tool correctly selects default cache policy.
If there's an activation volume_filter, it might not be possible
to activate the rmeta LVs to wipe them. At least inherit any
LV tags from the parent LV while attempting this.
Checking for devices uses is_missing_pv() to check
if there is a device for the PV. is_missing_pv()
is based on the MISSING_PV flag, which does not
always correspond to !pv->dev. When using lvmetad,
a command like:
pvs --config 'devices/filter=["a|/dev/sdb|", "r|.*|"]'
will cause a number of PVs to have NULL pv->dev, but
not the MISSING_PV flag. So, NULL pv->dev needs to
also be checked.
Before executing modprobe for given module name, just check
if the module is not already present in /sys/module.
Useful when checking dm-cache-policy modules as we do not
having matching interface like for targets.
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
WARNING: Couldn't find device for segment belonging to fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
Probably not worth mentioning "segments" here, just state that devices
for an LV can't be all found during the check - it's less mysterious for
user then:
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find all devices for LV fedora/root while checking used and assumed devices.
WARNING: Couldn't find all devices for LV fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
When checking assumed PVs against real devices used for LVs and if
there's no device assigned for an assumed PV (e.g. due to filters),
do log_warn instead of log_error and continue checking LV segments
and associated assumed PVs further, just like we do log_warn elsewhere
in this situation.
This way user will see the warning for each LV which couldn't be
checked completely against real PVs used. Before, we logged only
the very first occurence of missing device for an LV in a VG and we
returned from the function doing this check for all the LVs in VG
immediately which may be a bit misleading because it didn't tell
user about all the other LVs and whether they could be checked
or not.
For example, we have this setup:
[0] fedora/~ # pvs
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
/dev/vda2 fedora lvm2 a-- 19.49g 0
[0] fedora/~ # lvs -o+devices
LV VG Attr LSize Devices
root fedora -wi-ao---- 19.00g /dev/vda2(0)
swap fedora -wi-ao---- 500.00m /dev/vda2(4864)
Before this patch (only the very first LV in a VG is logged to have a
problem while checking used and assumed devices):
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
With this patch applied (all LVs where we hit problem while checking
used and assumed devices are logged and it's warning, not error):
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
WARNING: Couldn't find device for segment belonging to fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
If lvmetad is running, and a command opts to not use it
(--config global/use_lvmetad=0), and the command changes
metadata, then the metadata change is not visible to
lvmetad. Subsequent commands using lvmetad to change
metadata may cause corruption based on the invalid
lvmetad state.
Eventually we can set the disabled state in lvmetad
to prevent this problem, but for now print a warning
about the possibility.
When command is not using lvmetad because
use_lvmetad=0 in the config, but the lvmetad
pidfile exists, print a warning (previously
this checked for the socket existing instead
of the pidfile existing.)
vg/snapshotN should not appear anywhere.
No code should be showing this, but it was noticed in some logs last
week and we can deal with it in display_lvname().
The lvmetad connection is created within the
init_connections() path during command startup,
rather than via the old lvmetad_active() check.
The old lvmetad_active() checks are replaced
with lvmetad_used() which is a simple check that
tests if the command is using/connected to lvmetad.
The old lvmetad_set_active(cmd, 0) calls, which
stopped the command from using lvmetad (to revert to
disk scanning), are replaced with lvmetad_make_unused(cmd).
After a device rescan that repopulates lvmetad,
if no reason for disabling lvmetad was seen
(lvm1 metadata or duplicate PVs), then clear
the disabled flag in lvmetad. This allows
commands to resume using the lvmetad cache
after the cause for disabling it has been removed.
Commands already check if the lvmetad token is valid,
and if not, they rescan devices to repopulate lvmetad
before running. Now, in addition to checking the
lvmetad token, they also check if the lvmetad disabled
flag is set. If so, they do not use the lvmetad cache
and revert to disk scanning.
A global flag in lvmetad indicates it has been disabled.
Other flags indicate the reason it was disabled.
These flags can be queried using get_global_info.
The lvmetactl debugging utility can set and clear the
disabled flag in lvmetad. Nothing else sets the
disabled flag yet.
Commands will check these flags after connecting to
lvmetad. If the disabled flag is set, the command
will not use the lvmetad cache, but revert to disk
scanning.
To test this feature:
$ lvmetactl get_global_info
response = "OK"
global_invalid = 0
global_disable = 0
disable_reason = "none"
token = "filter:3041577944"
$ vgs
(should report VGs from lvmetad)
$ lvmetactl set_global_disable 1
$ lvmetactl get_global_info
response = "OK"
global_invalid = 0
global_disable = 1
disable_reason = "DIRECT"
token = "filter:3041577944"
$ vgs
WARNING: Not using lvmetad because the disable flag was set directly.
(should report VGs without contacting lvmetad)
$ lvmetactl set_global_disable 0
$ vgs
(should report VGs from lvmetad)
Improve code for snapshot merge for readabilty
and also reduce number of tests needed to decide
if merging can or cannot be started.
(Further improving 9cccf5245a)