IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Free (and clear) h.protocol string on daemon_open() error paths
so it's OK for caller to skip calling daemon_close() if returned
h.socket_fd is -1.
Close h.socket_fd in daemon_close() to avoid possible leak.
https://bugzilla.redhat.com/1164234
- closer to the recommendation of man-pages (7) if possible
- Add crossrefs
- Sort options and crossrefs
- Fix default timeout (60 secs) of -t
- Documents -I[auto]
Signed-off-by: Stéphane Aulery <saulery@free.fr>
LVM2.2.02.112/daemons/clvmd/clvmd.c:1131: warning[arrayIndexOutOfBoundsCond]: Array 'row[8]' accessed at index 8, which is out of bounds. Otherwise condition 'j==8' is redundant.
This code:
int i,j = 0;
...
for (i = 0; i < len; ++i) {
...
if ((j == 8) || (i + 1 == len)) {
for (;j < 8; ++j) {
...
}
...
j = 0;
}
}
Indeed - j is 0 at the beginning, then iterating till j < 8,
then always zeroed at the end of the outer loop - so "j" never
reaching value of 8 - the j == 8 condition is redundant.
When responding to DM_EVENT_CMD_GET_REGISTERED_DEVICE no longer
ignore threads that have already been unregistered but which
are still present.
This means the caller can unregister a device and poll dmeventd
to ensure the monitoring thread has gone away before removing
the device. If a device was registered and unregistered in quick
succession and then removed, WAITEVENT could run in parallel with
the REMOVE.
Threads are moved to the _thread_registry_unused list when they
are unregistered.
The warnings arg was used to enable logging of warnings
when reading a PV. This arg is turned into a set of flags
with the WARN_PV_READ flag matching the existing behavior.
A new flag WARN_INCONSISTENT is added that will cause
vg_read_internal() to log the "VG is not consistent"
warning so the various callers do not need to log
this warning themselves.
A new vg_read flag READ_WARN_INCONSISTENT is used from
reporting to enable the WARN_INCONSISTENT flag in
vg_read_internal.
[Committed by agk with cosmetic changes and tweaks.]
Cmirrord has endian bugs, which cause failure to lvcreate a mirrored lv
on s390.
- data_size is uint32, should not use xlate64 to convert, which will
cause data_size 0 after xlate.
- request_type and data_size still used by local(v5_data_switch),
should convert later. If request_type xlate too early, it will
cause request_type judge error; if data_size xlate too early, it
will cause coredump in case DM_ULOG_CLEAR_REGION.
- when receiving package in clog_request_from_network. vp[0] will always
be little endian. We could use xlate64(vp[0]) == vp[0] to decide if
the local node is little endian or not.
Signed-off-by: Lidong Zhong<lzhong@suse.com> & Liuhua Wang <lwang@suse.com>
Signed-off-by: Jonathan Brassow <jbrassow@redhat.com>
The list of strings is used quite frequently and we'd like to reuse
this simple structure for report selection support too. Make it part
of libdevmapper for general reuse throughout the code.
This also simplifies the LVM code a bit since we don't need to
include and manage lvm-types.h anymore (the string list was the
only structure defined there).
Switch to allocate buffer from heap, since it might be potentially
bigger when extremaly large set of volumes would be monitored.
In case of allocation failure send ENOMEM message.
Also implicitelly ignore msg->size when msg->data is NULL.
Prior adding new reply to the list, check
if the reply thread is not already finished.
In that case discard adding message
(which would otherwise be leaked).
Use mutex to access localsock values, so check
num_replies when the thread is not yet finished.
Check for threadid prior the mutex taking
(though this check is probably not really needed)
Added complexity with extra reply mutex is not worth the troubles.
The only place which may slightly benefit from this mutex is timeout
and since this is rather error case - let's convert it to
localsock.mutex and keep it simple.
Move the pthread mutex and condition creation and destroy
to correct place right after client memory is allocatedd
or is going to be released.
In the original place it's been in race with lvm thread
which could have still unlock mutex while it's been already
destroyed.