Recognize DM_SUBSYSTEM_UDEV_FLAG0 which for LVM is the "LVM_NOSCAN"
flag that causes the scanning to be skipped (mainly blkid) and
also directs all the foreign rules to be skipped as well.
Important thing here is that the "watch" udev rules is still set
as well as the /dev/disk/by-id content created (which does not
require any scanning to be done). Also, the flag is dropped on
any subsequent event and scanning done...
A common scenario is during new LV creation when we need to wipe the
newly created LV and avoid any udev scanning before this stage otherwise
it could cause the device (the LV) to be claimed by some other subsystem
for which there were stale metadata within LV data.
This patch adds possibility to mark the LV we're just about to wipe with
a flag that gets passed to udev via DM_COOKIE as a subsystem specific
flag - DM_SUBSYSTEM_UDEV_FLAG0 (in this case the subsystem is "LVM")
so LVM udev rules will take care of handling that.
Patch 562ad293fd introduced code regression
when LV was converted to a thin LV with external origin and at the same time,
conversion of LV to a thin pool has been requested.
(RHBZ: #997704)
data_lv needs to be assigned after test for external conversion find pool.
Accept --ignoreskippedcluster with pvs, vgs, lvs, pvdisplay, vgdisplay,
lvdisplay, vgchange and lvchange to avoid the 'Skipping clustered
VG' errors when requesting information about a clustered VG
without using clustered locking and still exit with success.
The messages can still be seen with -v.
Just like we have symbolic names assigned to general DM udev flags
(DM_UDEV_* flags), we have the same for any subsystem flags now
(DM_SUBSYSTEM_UDEV_FLAG*), making it easier to use.
Each subsystem rule that needs to import any of DM_SUBSYSTEM_UDEV_FLAG*
flags is responsible for doing so. This simply moves control of these
flags from general 10-dm.rules to any subsystem rule using these flags
as each subsystem knows better how to handle these flags on its own.
Some code has been added recently which makes it impossible to compile
when "configure --disable-devmapper" is used. This patch just shuffles
the code around so it's under proper #ifdef DEVMAPPER_SUPPORT.
lib/metadata/lv_manip.c:_sufficient_pes_free() was calculating the
required space for RAID allocations incorrectly due to double
accounting. This resulted in failure to allocate when available
space was tight.
When RAID data and metadata areas are allocated together, the total
amount is stored in ah->new_extents and ah->alloc_and_split_meta is
set. '_sufficient_pes_free' was adding the necessary metadata extents
to ah->new_extents without ever checking ah->alloc_and_split_meta.
This often led to double accounting of the metadata extents. This
patch checks 'ah->alloc_and_split_meta' to perform proper calculations
for RAID.
This error is only present in the function that checks for the needed
space, not in the functions that do the actual allocation.
1) When converting from an x-way mirror/raid1 to a y-way mirror/raid1,
the default behaviour should be to stay the same segment type.
2) When converting from linear to mirror or raid1, the default behaviour
should honor the mirror_segtype_default.
3) When converting and the '--type' argument is specified, the '--type'
argument should be honored.
catch such conditions, but errors in the tests caused the issue to go
unnoticed. The code has been fixed to perform #2 properly, the tests
have been corrected to properly test for #2, and a few other tests
were changed to explicitly specify the '--type mirror' when necessary.
If "default" thin pool chunk size calculation method is selected,
use minimum_io_size, otherwise optimal_io_size for "performance"
device hint exposed in sysfs. If there appear to be PVs with
different hints presented, use their least common multiple.
If the hint is less than the default value defined for the
calculation method, use the default value instead.
Add allocation/thin_pool_chunk_size_calculation lvm.conf
option to select a method for calculating thin pool chunk
sizes and define two possible values - "default" and "performance".
A previous commit (b6bfddcd0a) which
was designed to prevent segfaults during lvextend when trying to
extend striped logical volumes forgot to include calculations for
RAID4/5/6 parity devices. This was causing the 'contiguous' and
'cling_by_tags' allocation policies to fail for RAID 4/5/6.
The solution is to remember that while we can compare
ah->area_count == prev_lvseg->area_count
for non-RAID, we should compare
(ah->area_count + ah->parity_count) == prev_lvseg->area_count
for a general solution.
lvmetad is not yet supported in clustered environment so
disable it automatically if using lvmconf --enable-cluster
and reset it to default value if using lvmconf --disable-cluster.
Also, add a few comments in lvm.conf about locking_type vs. use_lvmetad
if setting it for clustered environment.
The corosync cluster interface for clvmd did not correctly
deal with node up/down events so that when a node was removed
from the cluster clvmd would prevent remote operations
from happening, as it thought the node was up but not
running clvmd.
This patch fixes that code by simplifying the case to node
being up or down - which was the original intention
and is supported by pacemaker and CPG in the higher layers.
Signed-off-by: Christine Caulfield <ccaulfie@redhat.com>
When NULL info struct is passed in - function is usable
as a quick query for lv_is_active_locally() - with a bonus
we may query for layered device.
So it could be seen as a more efficient lv_is_active_locally().