IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
For more advanced support we need to ensure better logic for calling
external much more advanced script for maintanance of thin-pool.
So this new code ensures:
When thin-pool data or metadata is bigger then 50%,
then with each 5% increment, action is called.
This is independent from autoextend_threshold.
This action always happens when thin-pool is over threshold,
(so no action when it's exactly i.e. 60%).
The only exception is 100% full thin-pool - which invokes 'last'
action.
Since thin-pool occupancy may change also downward, code needs
to also handle possibly reduction of occupancy of thin-pool.
So when usage drop from 90% to 50%, thin-pool will start to call
again action when it will pass 55% threshold.
This give external commands lot of option i.e. to call 'fstrim'
before actual resize is needed.
Default internal logic will stop trying to do any 'rescue' action
when executed command fails.
This will be now fully in hands of external script if such
behaviour is needed.
Instead of stopping monitoring after couple failing retries,
keep monitoring forever, just make larger delays between command
retries (ATM upto ~42 minutes).
So syslog is not spammed too often, yet commands have a chance to
be retried and succeed eventually...
When dmeventd configured command does not start with 'lvm ' prefix,
it's going to be an 'external' command.
In this case we split command by spaces to argv strings.
When showing sizes with 'H|human' units we do use standard rounding.
This however is confusing users from time to time,
when the printed number uses some biger units i.e. GiB and there is just
tiny fraction of space missing.
So here is some real-life example with new 'r' unit.
$lvs
LV VG Attr LSize Pool Origin
lvol0 vg -wi-a----- 1.99g
lvol1 vg -wi-a----- <2.00g
lvol2 vg -wi-a----- <2.01g
Meaning is - lvol1 has 'slightly' less then 2.00g - from sign '<' user
can be aware the LV doesn't have full 2.00GiB in size so he
will be less surpriced allocation of 2G volume will not succeed.
$ vgs
VG #PV #LV #SN Attr VSize VFree
vg 2 2 0 wz--n- <6,00g <2,01g
For uses needing 'old' undecorated human unit simply will continue
to use 'H|h' units.
The new R|r may further change when we would recongnize some
other way how to improve readability.
With recent commit d6a74025df using
INTERNAL_ERROR while cheking layer LV - it's been noticed mirror
logic currently doesn't do a correct thing during upconversion and
does a full-try instead of checking only allocator capabilities.
This leads to invalid usage of layer.
To keep existing code running before providing a fix, relax
INTERNAL_ERROR just an error and keep the 'code' running.
Once mirror code is fixed, these all check should be switched
to internal errors.
The blkdeactivate script processes MD devices too so we should unmount
any mount point on top of an MD device if blkdeactivate -u|--umount is
called.
Diagnosed and reported by: Rick Warner <rick@microway.com>
See also https://bugzilla.redhat.com/show_bug.cgi?id=1410585.
Since we still experience occasiaonal test failure - slow
things down even more to avoid race.
Add support for 'quick' table changes between normal & delayed tables.
This was missing piece in 77997c7673.
When merging origin is inactive (while driver is loaded) we
could already report merge in progress values as there is
no way to activate 'old state' now.
Show proper internal error for failing command when there are some
inconsitencies in sizes of LV and its layer instead of rather
meaningless error code 5.
(Could be hit i.e. if user tried to 'resize' cached LV and then
uncache such LV.)
During rework of resize code this validation check
has been lost (in my resize branch). Upstream
is still not supporting resize of any cache type LV
so needs to be prevented.
When we need to clear dirty cache content of cached LV, there
is table reload which usually is shortly followed by next metadata
change. However udev can't (as of now) process udev event
while device is 'suspended'.
So whenever sequence of 'suspend/resume/suspend' is needed,
we need to wait first for finishing of 'resume' processing before
starting next 'suspend'. Otherwise there is 'race' danger of triggering
unwantend umount by systemd as such event will trigger
SYSTEMD_READY=0 state for a moment for such changed device.
Such race is pretty ugly to trace so we may need to review more
sequencies for missing 'sync'.
(Other option is to enhnace 'udev' rules processing to avoid
such dramatic actions to be happening for suspended devices).
Solves: https://bugzilla.redhat.com/1280496
The only reasonable behaviour here is to error on
any number out of accepted range (i.e. now numbers
wrapping around with some hidden logic).
As this is plain bug there is no support for
backward compatibility since noone should
set numbers >UINT32_MAX and expect 0 or error
depending on how big number was used....
TODO: more fields might need to be converted.
Add simple function to wrap usage for only uint32 numbers.
Unlike 'int_arg' which accepts full range of 64bit number
this function will error on numbers out of this range:
<0, UINT32_MAX>
Add to commits 87117c2b25 and 0b8bf73a63 to avoid refreshing two
times altogether, thus avoiding issues related to clustered, remotely
activated RaidLV. Avoid need to repeat "lvchange --refresh RaidLV"
two times as a workaround to refresh a RaidLV. Fix handles removal
of temporary *-missing-* devices created for any missing segments
in RAID SubLVs during activation.
Because the kernel dm-raid target isn't able to handle transiently
failing devices properly we need
"[dm-devel][PATCH] dm raid: fix transient device failure processing"
as well.
test: add lvchange-raid-transient-failures.sh
and enhance lvconvert-raid.sh
Resolves: rhbz1025322
Related: rhbz1265191
Related: rhbz1399844
Related: rhbz1404425
When thin-pool processes event and 'lvextend --use-policies' fails
rather capture up-to-date new info as the fullness percentage may
have jumped noticable. This way we could use 'more' correct numbers
when checking for thresholds.