mirror of
https://github.com/systemd/systemd-stable.git
synced 2025-01-22 22:03:43 +03:00
man: describe the syntax for {Job,}{Running,}TimeoutSec=
Fixes #16644. Also break the text into paragraphs to make it a bit easier to read.
This commit is contained in:
parent
09d9081447
commit
fc070a2574
@ -976,16 +976,24 @@
|
||||
<term><varname>JobTimeoutSec=</varname></term>
|
||||
<term><varname>JobRunningTimeoutSec=</varname></term>
|
||||
|
||||
<listitem><para>When a job for this unit is queued, a timeout <varname>JobTimeoutSec=</varname> may be
|
||||
configured. Similarly, <varname>JobRunningTimeoutSec=</varname> starts counting when the queued job is actually
|
||||
started. If either time limit is reached, the job will be cancelled, the unit however will not change state or
|
||||
even enter the <literal>failed</literal> mode. This value defaults to <literal>infinity</literal> (job timeouts
|
||||
disabled), except for device units (<varname>JobRunningTimeoutSec=</varname> defaults to
|
||||
<varname>DefaultTimeoutStartSec=</varname>). NB: this timeout is independent from any unit-specific timeout
|
||||
(for example, the timeout set with <varname>TimeoutStartSec=</varname> in service units) as the job timeout has
|
||||
no effect on the unit itself, only on the job that might be pending for it. Or in other words: unit-specific
|
||||
timeouts are useful to abort unit state changes, and revert them. The job timeout set with this option however
|
||||
is useful to abort only the job waiting for the unit state to change.</para>
|
||||
<listitem><para><varname>JobTimeoutSec=</varname> specifies a timeout for the whole job that starts
|
||||
running when the job is queued. <varname>JobRunningTimeoutSec=</varname> specifies a timeout that
|
||||
starts running when the queued job is actually started. If either limit is reached, the job will be
|
||||
cancelled, the unit however will not change state or even enter the <literal>failed</literal> mode.
|
||||
</para>
|
||||
|
||||
<para>Both settings take a time span with the default unit of seconds, but other units may be
|
||||
specified, see
|
||||
<citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
The default is <literal>infinity</literal> (job timeouts disabled), except for device units where
|
||||
<varname>JobRunningTimeoutSec=</varname> defaults to <varname>DefaultTimeoutStartSec=</varname>.
|
||||
</para>
|
||||
|
||||
<para>Note: these timeouts are independent from any unit-specific timeouts (for example, the timeout
|
||||
set with <varname>TimeoutStartSec=</varname> in service units). The job timeout has no effect on the
|
||||
unit itself. Or in other words: unit-specific timeouts are useful to abort unit state changes, and
|
||||
revert them. The job timeout set with this option however is useful to abort only the job waiting for
|
||||
the unit state to change.</para>
|
||||
</listitem>
|
||||
</varlistentry>
|
||||
|
||||
@ -993,13 +1001,14 @@
|
||||
<term><varname>JobTimeoutAction=</varname></term>
|
||||
<term><varname>JobTimeoutRebootArgument=</varname></term>
|
||||
|
||||
<listitem><para><varname>JobTimeoutAction=</varname> optionally configures an additional action to take when
|
||||
the timeout is hit, see description of <varname>JobTimeoutSec=</varname> and
|
||||
<listitem><para><varname>JobTimeoutAction=</varname> optionally configures an additional action to
|
||||
take when the timeout is hit, see description of <varname>JobTimeoutSec=</varname> and
|
||||
<varname>JobRunningTimeoutSec=</varname> above. It takes the same values as
|
||||
<varname>StartLimitAction=</varname>. Defaults to <option>none</option>.
|
||||
<varname>JobTimeoutRebootArgument=</varname> configures an optional reboot string to pass to the
|
||||
<citerefentry><refentrytitle>reboot</refentrytitle><manvolnum>2</manvolnum></citerefentry> system call.
|
||||
</para></listitem>
|
||||
<varname>StartLimitAction=</varname>. Defaults to <option>none</option>.</para>
|
||||
|
||||
<para><varname>JobTimeoutRebootArgument=</varname> configures an optional reboot string to pass to
|
||||
the <citerefentry><refentrytitle>reboot</refentrytitle><manvolnum>2</manvolnum></citerefentry> system
|
||||
call.</para></listitem>
|
||||
</varlistentry>
|
||||
|
||||
<varlistentry>
|
||||
@ -1007,28 +1016,39 @@
|
||||
<term><varname>StartLimitBurst=<replaceable>burst</replaceable></varname></term>
|
||||
|
||||
<listitem><para>Configure unit start rate limiting. Units which are started more than
|
||||
<replaceable>burst</replaceable> times within an <replaceable>interval</replaceable> time interval are not
|
||||
permitted to start any more. Use <varname>StartLimitIntervalSec=</varname> to configure the checking interval
|
||||
(defaults to <varname>DefaultStartLimitIntervalSec=</varname> in manager configuration file, set it to 0 to
|
||||
disable any kind of rate limiting). Use <varname>StartLimitBurst=</varname> to configure how many starts per
|
||||
interval are allowed (defaults to <varname>DefaultStartLimitBurst=</varname> in manager configuration
|
||||
file). These configuration options are particularly useful in conjunction with the service setting
|
||||
<varname>Restart=</varname> (see
|
||||
<citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry>); however,
|
||||
they apply to all kinds of starts (including manual), not just those triggered by the
|
||||
<varname>Restart=</varname> logic. Note that units which are configured for <varname>Restart=</varname> and
|
||||
which reach the start limit are not attempted to be restarted anymore; however, they may still be restarted
|
||||
manually at a later point, after the <replaceable>interval</replaceable> has passed. From this point on, the
|
||||
restart logic is activated again. Note that <command>systemctl reset-failed</command> will cause the restart
|
||||
rate counter for a service to be flushed, which is useful if the administrator wants to manually start a unit
|
||||
and the start limit interferes with that. Note that this rate-limiting is enforced after any unit condition
|
||||
checks are executed, and hence unit activations with failing conditions do not count towards this rate
|
||||
limit. This setting does not apply to slice, target, device, and scope units, since they are unit types whose
|
||||
activation may either never fail, or may succeed only a single time.</para>
|
||||
<replaceable>burst</replaceable> times within an <replaceable>interval</replaceable> time span are
|
||||
not permitted to start any more. Use <varname>StartLimitIntervalSec=</varname> to configure the
|
||||
checking interval and <varname>StartLimitBurst=</varname> to configure how many starts per interval
|
||||
are allowed.</para>
|
||||
|
||||
<para>When a unit is unloaded due to the garbage collection logic (see above) its rate limit counters are
|
||||
flushed out too. This means that configuring start rate limiting for a unit that is not referenced continuously
|
||||
has no effect.</para></listitem>
|
||||
<para><replaceable>interval</replaceable> is a time span with the default unit of seconds, but other
|
||||
units may be specified, see
|
||||
<citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
Defaults to <varname>DefaultStartLimitIntervalSec=</varname> in manager configuration file, and may
|
||||
be set to 0 to disable any kind of rate limiting. <replaceable>burst</replaceable> is a number and
|
||||
defaults to <varname>DefaultStartLimitBurst=</varname> in manager configuration file.</para>
|
||||
|
||||
<para>These configuration options are particularly useful in conjunction with the service setting
|
||||
<varname>Restart=</varname> (see
|
||||
<citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry>);
|
||||
however, they apply to all kinds of starts (including manual), not just those triggered by the
|
||||
<varname>Restart=</varname> logic.</para>
|
||||
|
||||
<para>Note that units which are configured for <varname>Restart=</varname>, and which reach the start
|
||||
limit are not attempted to be restarted anymore; however, they may still be restarted manually at a
|
||||
later point, after the <replaceable>interval</replaceable> has passed. From that point on, the
|
||||
restart logic is activated again. <command>systemctl reset-failed</command> will cause the restart
|
||||
rate counter for a service to be flushed, which is useful if the administrator wants to manually
|
||||
start a unit and the start limit interferes with that. Rate-limiting is enforced after any unit
|
||||
condition checks are executed, and hence unit activations with failing conditions do not count
|
||||
towards the rate limit.</para>
|
||||
|
||||
<para>When a unit is unloaded due to the garbage collection logic (see above) its rate limit counters
|
||||
are flushed out too. This means that configuring start rate limiting for a unit that is not
|
||||
referenced continuously has no effect.</para>
|
||||
|
||||
<para>This setting does not apply to slice, target, device, and scope units, since they are unit
|
||||
types whose activation may either never fail, or may succeed only a single time.</para></listitem>
|
||||
</varlistentry>
|
||||
|
||||
<varlistentry>
|
||||
|
@ -73,7 +73,7 @@
|
||||
the current server does not satisfy this limit, <command>systemd-timesyncd</command> will switch
|
||||
to a different server.</para>
|
||||
|
||||
<para>Takes a time value. The default unit is seconds, but other units may be specified, see
|
||||
<para>Takes a time span value. The default unit is seconds, but other units may be specified, see
|
||||
<citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
Defaults to 5 seconds.</para></listitem>
|
||||
</varlistentry>
|
||||
@ -85,8 +85,9 @@
|
||||
minimum poll interval, and is adjusted within the specified limits in response to received packets.
|
||||
</para>
|
||||
|
||||
<para>Each setting takes a time value. The default unit is seconds, but other units may be specified,
|
||||
see <citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
<para>Each setting takes a time span value. The default unit is seconds, but other units may be
|
||||
specified, see
|
||||
<citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
<varname>PollIntervalMinSec=</varname> defaults to 32 seconds and must not be smaller than
|
||||
16 seconds. <varname>PollIntervalMaxSec=</varname> defaults to 34 min 8 s (2048 seconds) and must be
|
||||
larger than <varname>PollIntervalMinSec=</varname>.</para></listitem>
|
||||
@ -97,7 +98,7 @@
|
||||
<listitem><para>Specifies the minimum delay before subsequent attempts to contact a new NTP server
|
||||
are made.</para>
|
||||
|
||||
<para>Takes a time value. The default unit is seconds, but other units may be specified, see
|
||||
<para>Takes a time span value. The default unit is seconds, but other units may be specified, see
|
||||
<citerefentry><refentrytitle>systemd.time</refentrytitle><manvolnum>5</manvolnum></citerefentry>.
|
||||
Defaults to 30 seconds and must not be smaller than 1 second.</para></listitem>
|
||||
</varlistentry>
|
||||
|
Loading…