If we have to force the logging to close the journal fd, then we can open
any fallback log target. E.g. kmsg, if the target was the default
JOURNAL_OR_KMSG.
This is the behaviour I would expect from the documentation. I couldn't
find any justification in the code, for why we would want to start dropping
log messages instead of sending them to the fallback target.
This means we will match the behaviour of processes which we fork and which
set `open_when_needed`, and with generators - which use
log_set_prohibit_ipc(true) - which we fork+exec during a reload.
IMO this illustrates that the log_open/log_close interface is too clunky.
So with the behaviour settled, I will refactor the interface in the next
commit :).
Previously, we'd explicitly use "GetUnit()" on the server side to
convert a unit name into a bus path, as that function will return an
error if the unit is not currently loaded. If we'd convert the path on
the client side, and access the unit this way directly the unit would be
loaded automatically in the background.
The old logic was done in order to minimize the effect of "is-active" on
the system, i.e. that a monoitoring command does not itself alter the
state of the system.
however, this is problematic as this can lead to confusing results if
the queried unit name is an alias that currently is not loaded: we'd
claim the unit wasn't active even though this isn't strictly true: the
unit the name is an alias for might be.
Hence, let's simplify the code, and accept that we might end up loading
a unit briefly here, and let's make "systemctl is-active" skip the
GetUnit() thing and calculate the unit path right away.
Fixes: #7875
Before this, `systemctl show` for calendar type timer unit outputs
something like below.
```
NextElapseUSecRealtime=48y 3w 3d 15h
NextElapseUSecMonotonic=0
LastTriggerUSec=48y 3w 3d 3h 41min 44.093095s
LastTriggerUSecMonotonic=0
```
As both NextElapseUSecRealtime= and LastTriggerUSec= are not timespan
but timestamp, this makes format these values by `format_timestamp()`.
/dev/mmcblk0boot0 is a partition found in eMMC
This is not relevant for mounting
This complement the previous fix as reported in
https://github.com/systemd/systemd/issues/5806
Signed-off-by: Nicolas Chauvet <kwizart@gmail.com>
Let's add a per-unit boolean that tells us whether our unit is currently
counted or not. This way it's unlikely we get out of sync again and
things are generally more robust.
This also allows us to remove the counting logic specific to service
units (which was in fact mostly a copy from the generic implementation),
in favour of fully generic code.
Replaces: #7824
This call determines whether a specific unit currently needs access to
the console. It's a fancy wrapper around
exec_context_may_touch_console() ultimately, however for service units
we'll explicitly exclude the SERVICE_EXITED state from when we report
true.
Since the the whole function ultimately is just a fancy getter for the
show_status field, let's actually return it as last step literally
without an extra needless "if".
This removes LOG_TARGET_SAFE. It's made redundant by the new
"prohibit-ipc" logging flag, as it used to have a similar effect: avoid
logging to the journal/syslog, i.e. any local services in order to avoid
deadlocks when we lock from PID 1 or its utility processes (such as
generators).
All previous users of LOG_TARGET_SAFE are switched over to the new
setting. This makes things a bit safer for all, as not even the
SYSTEMD_LOG_TARGET env var can be used to accidentally log to the
journal anymore in these programs.
If set, we'll avoid logging to any IPC log targets, i.e. syslog or the
journal, but allow stderr, kmsg, console logging.
This is useful as PID 1 wants to turn this off explicitly as long as the
journal is not up.
Previously we'd open/close the log stream to these services whenever
needed but this is incompatible with the "open_when_needed" logic
introduced in #6915, which might open the log streams whenever it likes,
including possibly inside of the child process we fork off that'll
become journald later on. Hence, let's make this all explicit, and
instead of managing when we open/close log streams add a boolean that
clearly prohibits the IPC targets when needed, so that opening can be
done at any time, but will honour this.
See: #7985
This doesn't matter much, and we don't rely on it, but I think it's much
nicer if we log_set_target() and log_set_upgrade_syslog_to_journal() can
be called in either order and have the same effect.
It is often the case that a file descriptor and its corresponding IO
sd_event_source share a life span. When this is the case, developers will
have to unref the event source and close the file descriptor. Instead, we
can just have the event source take ownership of the file descriptor and
close it when the event source is freed. This is especially useful when
combined with cleanup attributes and sd_event_source_unrefp().
This patch adds two new public functions:
sd_event_source_get_io_fd_own()
sd_event_source_set_io_fd_own()
The time-related functions in sd-event.h take as inputs constants (CLOCK_*)
defined in time.h. By including time.h in sd-event.h, we free the developer
from having to do this manually.
When there is a change in mac address we are not currently not changing
the MAC address and resulting v6 connectivity is gone.
When kernel reports a change in mac address change the MAC of ndisc
client too.
Closes # 7806
Apparently O_NONBLOCK is the modern name used in most documentation and
for most cases in our sources. Let's hence replace the old alias
O_NDELAY and stick to O_NONBLOCK everywhere.
CHANGE OF BEHAVIOUR — with this commit "f" line's behaviour is altered
to match what the documentation says: if an "argument" string is
specified it is written to the file only when the file didn't exist
before. Previously, it would be appended to the file each time
systemd-tmpfiles was invoked — which is not a particularly useful
behaviour as the tool is not idempotent then and the indicated files
grow without bounds each time the tool is invoked.
I did some spelunking whether this change in behaviour would break
things, but afaics nothing relies on the previous O_APPEND behaviour of
this line type, hence I think it's relatively safe to make "f" lines
work the way the docs say, rather than adding a new modifier for it or
so.
Triggered by:
https://lists.freedesktop.org/archives/systemd-devel/2018-January/040171.html
The left side of the || expression is conditionalized on SERVICE_START,
but SERVICE_START is blanket listed on the right side anyway, hence we
can drop the left side entirely without any change in behaviour.
Moreover, if main_pid is initialized, it should be watched, hence this
is even the safe and right thing to do.
Previously, we'd maintain two hashmaps keyed by PIDs, pointing to Unit
interested in SIGCHLD events for them. This scheme allowed a specific
PID to be watched by exactly 0, 1 or 2 units.
With this rework this is replaced by a single hashmap which is primarily
keyed by the PID and points to a Unit interested in it. However, it
optionally also keyed by the negated PID, in which case it points to a
NULL terminated array of additional Unit objects also interested. This
scheme means arbitrary numbers of Units may now watch the same PID.
Runtime and memory behaviour should not be impact by this change, as for
the common case (i.e. each PID only watched by a single unit) behaviour
stays the same, but for the uncommon case (a PID watched by more than
one unit) we only pay with a single additional memory allocation for the
array.
Why this all? Primarily, because allowing exactly two units to watch a
specific PID is not sufficient for some niche cases, as processes can
belong to more than one unit these days:
1. sd_notify() with MAINPID= can be used to attach a process from a
different cgroup to multiple units.
2. Similar, the PIDFile= setting in unit files can be used for similar
setups,
3. By creating a scope unit a main process of a service may join a
different unit, too.
4. On cgroupsv1 we frequently end up watching all processes remaining in
a scope, and if a process opens lots of scopes one after the other it
might thus end up being watch by many of them.
This patch hence removes the 2-unit-per-PID limit. It also makes a
couple of other changes, some of them quite relevant:
- manager_get_unit_by_pid() (and the bus call wrapping it) when there's
ambiguity will prefer returning the Unit the process belongs to based on
cgroup membership, and only check the watch-pids hashmap if that
fails. This change in logic is probably more in line with what people
expect and makes things more stable as each process can belong to
exactly one cgroup only.
- Every SIGCHLD event is now dispatched to all units interested in its
PID. Previously, there was some magic conditionalization: the SIGCHLD
would only be dispatched to the unit if it was only interested in a
single PID only, or the PID belonged to the control or main PID or we
didn't dispatch a signle SIGCHLD to the unit in the current event loop
iteration yet. These rules were quite arbitrary and also redundant as
the the per-unit handlers would filter the PIDs anyway a second time.
With this change we'll hence relax the rules: all we do now is
dispatch every SIGCHLD event exactly once to each unit interested in
it, and it's up to the unit to then use or ignore this. We use a
generation counter in the unit to ensure that we only invoke the unit
handler once for each event, protecting us from confusion if a unit is
both associated with a specific PID through cgroup membership and
through the "watch_pids" logic. It also protects us from being
confused if the "watch_pids" hashmap is altered while we are
dispatching to it (which is a very likely case).
- sd_notify() message dispatching has been reworked to be very similar
to SIGCHLD handling now. A generation counter is used for dispatching
as well.
This also adds a new test that validates that "watch_pid" registration