Ask for lock the proper LV.
Use the top-most LV to query for locally exclusive lock.
The rest of operations are then using 'lv_info()'
TODO:
Check all devices are reloaded from proper level.
In general any query on lv_is_active is supposed to be running
ona lv_lock_holder() volume.
Instead of segtype->ops->name() introduce lvseg_name().
This also allows us to leave name() function 'empty' for default
return of segtype->name.
TODO: add functions for rest of ops->
--splitcache
Splits only cached LV (also pool could be specified).
Detaches cachepool from cached LV.
--split
Should be univerzal command to split various complex targets.
At this moment it knows cache.
--uncache
Opposite command to --cache. Detaches and DELETES cachepool for
cached LV.
Note: we support thin pool cached metadata device for uncaching.
Also use may specify wither cached LV or association cachepool device
to request split of cache.
The cache mode of a new cache pool is always explicitly
included in the vg metadata. If a cache mode is not
specified on the command line, the cache mode is taken
from lvm.conf allocation/cache_pool_cachemode, which
defaults to "writethrough".
The cache mode can be displayed with lvs -o+cachemode.
We are not using already defined segement type names where we could.
There is a lot of other places in device-mapper and LVM2 we have those
hardcoded so we should better finally have a common interface in
libdevmapper to avoid this.
Use of lv_info() internally in lv_check_not_in_use(),
so it always could use with_open_count properly.
Skip sysfs() testing in open_count == 0 case.
Accept just 'lv' pointer like other functions.
The function has 'built-in' lv_is_active_locally check,
which however is not what we need to check in many place.
For now at least remotely active snapshot merge is
detected and for this case merge on next activation is scheduled.
Move check for snapshot-merge support before archiving.
Split code on 2 paths - with merge_on_activate
using vg_write & vg_commit
and lv_update_reload call for instant merging.
Move printing after backup.
More validations before any thin or cache related conversion begins.
We allow to use and stack:
pool data: cache or raid
pool metadata: raid
pool: linear, striped
cache: linear, striped, raid
thin(extorig): linear, origin, cow, virtual, thin
We use adjusted_mirror_region_size() in two different contexts.
Either on command line -
here we do want to inform user about reduction of size.
Or in pvmove activation context -
here we should only use 'verbose' info.
Failure to copy the 'feature_flags' lvconvert_param to the matching
lv_segment field meant that when a user specified the cachemode argument,
the request was not honored.
Use lv_is_* macros throughout the code base, introducing
lv_is_pvmove, lv_is_locked, lv_is_converting and lv_is_merging.
lv_is_mirror_type no longer includes pvmove.
When testing conversion sanity, we checked lv->status & MIRRORED
which encompasses both old mirrors and raid1 mirrors. But we need to
ban only the old mirrors here hence allow raid1 mirrors.
The lv_type_name function is remnant from old code that reported
only single string for the LV type. LV types are now reported
in a more extended way as keyword list that describe the type
precisely (using lv_layout_and_type fn).
The lv_type_name was used in some error messages to display the
type of the LV so just reinstate the old messages back referencing
the type directly with a string - this is enough for error messages.
They don't need to display the LV type as precisely as it's used
on lvs output (which is optimized for selection anyway).
Fix get_pool_params to only read params.
Add poolmetadataspare option to get_pool_params.
Move all profile code into update_pool_params.
Move recalculate code into pool_manip.c
Revert logic and rename new arg_ functions to:
arg_from_list_is_set()
arg_outside_list_is_set()
When err_found is given, log_error message is automaticaly
printed.
Support --repair and --use-policies with mirrors.
(fixes another regression from lvconvert change for thin and cache).
TODO: the code path for mirror needs update.
Major update of lvconvert code to handle cache and thin.
related targets.
Code tries to unify handling of cache and thin pools.
Better supports lvm2 syntax:
lvconvert --type cache --cachepool vg/pool vg/cache
lvconvert --type thin --thinpool vg/pool vg/extorg
lvconvert --type cache-pool vg/pool
lvconvert --type thin-pool vg/pool
as well as:
lvconvert --cache --cachepool vg/pool vg/cache
lvconvert --thin --thinpool vg/pool vg/extorg
lvconvert --cachepool vg/pool
lvconvert --thinpool vg/pool
While catching much more command line errors.
(Yet couple paths still needs more tests)
Detects as much cmdline errors prior opening VG.
Uses single lvconvert_name_params to convert LV names.
Detects as much incompatibilies in VG prior prompting.
Uses single prompt to confirm whole conversion.
TODO: still the code needs fixes...
Since the type passed LV is changed and content of data detroyed,
query user with prompt to confirm this operation.
Also add a proper wiping of header.
Using '--yes' will skip this prompt:
lvconvert -s --yes vg/lv vg/lvcow
mirror_or_raid_type_requested really checks for mirror type.
Convert macros mirror_or_raid_type_requested() and
snapshot_type_requested() into inline functions.
Since vg_name inside /lib function has already been ignored mostly
except for a few debug prints - make it and official internal API
feature.
vg_name is used only in /tools while the VG is not yet openned,
and when lvresize/lvcreate /lib function is called with VG pointer
already being used, then vg_name becomes irrelevant (it's not been
validated anyway).
So any internal user of lvcreate_params and lvresize_params does not
need to set vg_name pointer and may leave it NULL.
Use NAME_LEN constant to simplify creation of device name.
Since the max size should be already tested in validation,
throw INTERNAL_ERROR if the size of vg/lv is bigger then NAME_LEN.
While polling for snapshot, detect first the snapshot still
exits. It's valid to have multiple polling threads watching
for the same thing and just 1 can 'win' the finish part.
All others should nicely 'fail'.
Warn user before converting volume to different type.
WARNING: Converting vg/lvol0 logical volume to pool's meta/data volume.
THIS WILL DESTROY CONTENT OF LOGICAL VOLUME (filesystem etc.)
Since the content of volume is lost we have to query user to confirm
such operation. If user is 100% sure, he may use '--yes' to avoid prompts.
Delay archiving of metadata until we really start to
update metadata when converting volume into a snapshot.
Archive is not necessary when we abort operation early.
Do not allow conversion of too small LV into a COW snapshot device.
Without this patch snapshot target is generating these kernel
messages before creation fails:
attempt to access beyond end of device
dm-9: rw=16, want=8, limit=2
attempt to access beyond end of device
...
device-mapper: table: 253:11: snapshot: Failed to read snapshot metadata
device-mapper: ioctl: error adding target to table
device-mapper: reload ioctl on failed: Input/output error
Usage of origin as a snapshot 'COW' volume is unsupported.
Without this test lvm2 is able to generate this ugly internal error message.
To test this:
lvcreate -L1 -n lv1 vg
lvcreate -L1 -n lv2 -s vg/lv1
lvcreate -L1 -n lv3 vg
lvconvert -s vg/lv3 vg/lv1
Internal error: LVs (5) != visible LVs (1) + snapshots (1) + internal LVs (0) in VG vg
Users now have the ability to convert their existing logical volumes
into cached logical volumes. A cache pool LV must be specified using
the '--cachepool' argument. The cachepool is the small, fast LV used
to cache the large, slow LV that is being converted.
This patch allows users to convert existing logical volumes into
cache pool LVs. Since cache pool LVs consist of data and metadata
sub-LVs, there is also the '--poolmetadata' (similar to thin_pool)
which allows for the specification of the metadata device.
Avoid use of external origin with size unaligned/incompatible with
thin pool chunk size, since the last chunk is not correctly provisioned
when it is overwritten.
Avoid starting conversion of the LV to the thin pool and thin volume
at the same time. Since this is mostly a user mistake, do not try
to just convert to one of those type, since we cannot assume if the
user wanted LV to become thin volume or thin pool.
Before the fix tool reported pretty strange internal error:
Internal error: Referenced LV lvol1_tdata not listed in VG mvg.
Fixed output:
lvconvert --thinpool lvol0 -T mvg/lvol0
Can't use same LV mvg/lvol0 for thin pool and thin volume.
At the end of lvconvert --snapshot with an active origin, the origin
gets reloaded.
Commit 57c0f72b1d ("lvconvert: use
_reload_lv on more places") accidentally replaced this with a snapshot
LV reload (which does nothing because only the origin is active).
Optimize and cleanup recently introduced new function wipe_lv.
Use compound literals to get nicely initialized wipe_params struct.
Pass in lv as explicit argument for wipe_lv.
Use cmd from lv structure.
Initialize only non-null members so it's easy to see what
is the special arg.
Drop find_merging_snapshot() function. Use find_snapshot()
called after check for lv_is_merging_origin() which
is the commonly used code path - so we avoid duplicated
tests and potential risk of derefering NULL point
in unhandled error path.
Use common wipe_lv (former set_lv) fn to do zeroing as well as signature
wiping if needed. Provide new struct wipe_lv_params to define the
functionality.
Bind "lvcreate -W/--wipesignatures y" with proper wipe_lv call.
Also, add "yes" and "force" to lvcreate_params so it's possible
to apply them for the prompt: "WARNING: %s detected on %s. Wipe it? [y/n]".
Revert 4777eb6872 which put
target_present check into init_snapshot_merge(). However
this function is also used when parsing metadata. So we would
get this present test performed even when target is not really
needed. So move this target_present test directly into lvconvert.
This is an addition to original patch for lvcreate - commit 039bdad.
The same principle applies to lvconvert where there are several steps
during which we need to wipe the existing LV that's being converted
to thin pool, making sure there's no other interference from outside (udev).
Prohibit conversion of pool device with active thin volumes.
Properly restore active states only for active thin pool volume.
Use new LV_NOSCAN when converting volume into thin pool's metadata.
Patch 562ad293fd introduced code regression
when LV was converted to a thin LV with external origin and at the same time,
conversion of LV to a thin pool has been requested.
(RHBZ: #997704)
data_lv needs to be assigned after test for external conversion find pool.
1) When converting from an x-way mirror/raid1 to a y-way mirror/raid1,
the default behaviour should be to stay the same segment type.
2) When converting from linear to mirror or raid1, the default behaviour
should honor the mirror_segtype_default.
3) When converting and the '--type' argument is specified, the '--type'
argument should be honored.
catch such conditions, but errors in the tests caused the issue to go
unnoticed. The code has been fixed to perform #2 properly, the tests
have been corrected to properly test for #2, and a few other tests
were changed to explicitly specify the '--type mirror' when necessary.
The same corner cases that exist for snapshots on mirrors exist for
any logical volume layered on top of mirror. (One example is when
a mirror image fails and a non-repair LVM command is the first to
detect it via label reading. In this case, the LVM command will hang
and prevent the necessary LVM repair command from running.) When
a better alternative exists, it makes no sense to allow a new target
to stack on mirrors as a new feature. Since, RAID is now capable of
running EX in a cluster and thin is not active-active aware, it makes
sense to pair these two rather than mirror+thinpool.
As further background, here are some additional comments that I made
when addressing a bug related to mirror+thinpool:
(https://bugzilla.redhat.com/show_bug.cgi?id=919604#c9)
I am going to disallow thin* on top of mirror logical volumes.
Users will have to use the "raid1" segment type if they want this.
This bug has come down to a choice between:
1) Disallowing thin-LVs from being used as PVs.
2) Disallowing thinpools on top of mirrors.
The problem is that the code in dev_manager.c:device_is_usable() is unable
to tell whether there is a mirror device lower in the stack from the device
being checked. Pretty much anything layered on top of a mirror will suffer
from this problem. (Snapshots are a good example of this; and option #1
above has been chosen to deal with them. This can also be seen in
dev_manager.c:device_is_usable().) When a mirror failure occurs, the
kernel blocks all I/O to it. If there is an LVM command that comes along
to do the repair (or a different operation that requires label reading), it
would normally avoid the mirror when it sees that it is blocked. However,
if there is a snapshot or a thin-LV that is on a mirror, the above code
will not detect the mirror underneath and will issue label reading I/O.
This causes the command to hang.
Choosing #1 would mean that thin-LVs could never be used as PVs - even if
they are stacked on something other than mirrors.
Choosing #2 means that thinpools can never be placed on mirrors. This is
probably better than we think, since it is preferred that people use the
"raid1" segment type in the first place. However, RAID* cannot currently
be used in a cluster volume group - even in EX-only mode. Thus, a complete
solution for option #2 must include the ability to activate RAID logical
volumes (and perform RAID operations) in a cluster volume group. I've
already begun working on this.
Creation, deletion, [de]activation, repair, conversion, scrubbing
and changing operations are all now available for RAID LVs in a
cluster - provided that they are activated exclusively.
The code has been changed to ensure that no LV or sub-LV activation
is attempted cluster-wide. This includes the often overlooked
operations of activating metadata areas for the brief time it takes
to clear them. Additionally, some 'resume_lv' operations were
replaced with 'activate_lv_excl_local' when sub-LVs were promoted
to top-level LVs for removal, clearing or extraction. This was
necessary because it forces the appropriate renaming actions the
occur via resume in the single-machine case, but won't happen in
a cluster due to the necessity of acquiring a lock first.
The *raid* tests have been updated to allow testing in a cluster.
For the most part, this meant creating devices with '-aey' if they
were to be converted to RAID. (RAID requires the converting LV to
be EX because it is a condition of activation for the RAID LV in
a cluster.)
If there is no RAID support in the kernel but the default mirror
segtype is "raid1", converting legacy mirrors can be problematic.
For example, changing the log type or converting a mirror to a linear
LV does not require the RAID modules to be present. However, because
lp->segtype is set to be RAID1 by the configuration file, the command
fails.
We should only be setting lp->segtype when converting mirrors if it is
going to change (e.g. to linear or between mirror types).
When creating a new thin pool and there's no profile requested
via "lvcreate --profile ...", inherit any VG profile if it's attached.
Currently this applies to these settings:
allocation/thin_pool_chunk_size
allocation/thin_pool_discards
allocation/thin_pool_zero
Initial basic support for repair.
It currently takes pool metadata spare volume, which
is used for recovery. New spare is created if the volume
is successfuly repaired.
After the operation the previous _tmeta volume is moved
into _tmeta%d volume and if everything is ok, this volume
could be removed.
New _tmeta needs to be pvmoved to proper place and also
converted to i.e. mirror if it should be mirrored.
Later version will try to automate some steps here.
Suggest to use _tdata and _tmeta devices for that.
This fixes regression from too relaxed change in
f1d5f6ae81
Without this patch there are some empty LVs created before
mirror code recognizes it cannot continue.
(in release fix)
The --type mirror requires -m/--mirrrors:
lvconvert --type mirror vg/lvol0
--type mirror requires -m/--mirrors
Run `lvconvert --help' for more information.
The --type raid* is allowed (the checks already existed):
lvconvert --type raid10 vg/lvol0
Converting the segment type for vg/lvol0 from linear to raid10 is not yet supported.
The --type snapshot is a synonym to -s/--snapshot:
lvconvert -s vg/lvol0 vg/lvol1
Logical volume lvol1 converted to snapshot.
lvconvert --type snapshot vg/lvol0 vg/lvol1
Logical volume lvol1 converted to snapshot.
All the other segment types are not supported, e.g.:
lvconvert --type zero vg/lvol0
Conversion using --type zero is not supported.
Run `lvconvert --help' for more information.
Condition needs to check for passed in pool_metadata_lv_name
which needs to be renamed to _tmeta, for !pool_metadata_lv_name
it's already created with correct _tmeta name.
These settins are customizable by profiles:
allocation/thin_pool_zero
allocation/thin_pool_discards
allocation/thin_pool_chunk_size
activation/thin_pool_autoextend_threshold
activation/thin_pool_autoextend_percent
If the user would upconvert a linear LV to a mirror without specifying
the segment type ("--type mirror" vs "--type raid1"), the "mirror"
segment type would be chosen without consulting the 'default_mirror_segtype'
setting in lvm.conf. This is now used as the basis for determining
which should be used if left unspecified.
Previously, we have relied on UUIDs alone, and on lvmcache to make getting a
"new copy" of VG metadata fast. If the code which triggers the activation has
the correct VG metadata at hand (the version which is currently on disk), it can
now hand it to the activation code directly.