IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
commit 15da467b was meant to address the case where
use_lvmetad=1 in lvm.conf, and lvmetad is not available,
in which case, pvscan --cache -aay should activate LVs.
But the commit unintentionally also changed the case
where use_lvmetad=0 in lvm.conf, in which case
pvscan --cache -aay should not activate LVs, so fix
that here.
When pvscan --cache -aay fails to connect to lvmetad it will
simply exit and do nothing. Change this so that it will
skip the lvmetad cache step and do the activation step from
disk.
We were initially looking to see if an LV was hidden and if it was we were
creating an instance of a LvCommon object to represent it. Thus if we
had a hidden cache pool for example we were missing the methods and
properties for the cache pool. However, when we create the object path,
any hidden LVs, regardless of type/functionality will be placed in the
hidden path.
The object manager method get_object_by_lvm_id was used in many cases for
the sole reason of getting the object path for the object. Instead of
retrieving the object and then calling 'dbus_object_path' on the object, we
are adding a method which returns the object path.
When we are processing the LVs we need to build up dbus objects from least
dependent to most dependent, so that we have information available when
constructing.
Original code missed to catch all apperances of SIGINT.
Also enhance logging when running in shell without tty.
Accept this regex as valid input:
'^[ ^t]*([Yy]([Ee]([Ss]|)|)|[Nn]([Oo]|))[ ^t]*$'
Some commands scan labels to populate lvmcache multiple
times, i.e. lvmcache_init, scan labels to fill lvmcache,
lvmcache_destroy, then later repeat
Each time labels are scanned, duplicates are detected,
and preferred devices are chosen. Each time this is done
within a single command, we want to choose the same
preferred devices. So, check for existing preferences
when choosing preferred devices.
This also fixes a problem with the list of unused duplicate
devs when run in an lvm shell. The devs had been allocated
from cmd memory, resulting in invalid list entries between
commands.
A number of places are working on a specific dev when they
call lvmcache_info_from_pvid() to look up an info struct
based on a pvid. In those cases, pass the dev being used
to lvmcache_info_from_pvid(). When a dev is specified,
lvmcache_info_from_pvid() will verify that the cached
info it's using matches the dev being processed before
returning the info. Calling code will not mistakenly
get info for the wrong dev when duplicate devs exist.
This confusion was happening when scanning labels when
duplicate devs existed. label_read for the first dev
would add an info struct to lvmcache for that dev/pvid.
label_read for the second dev would see the pvid in
lvmcache from first dev, and mistakenly conclude that
the label_read from the second dev can be skipped
because it's already been done. By verifying that the
dev for the cached pvid matches the dev being read,
this mismatch is avoided and the label is actually read
from the second duplicate.
If a command gets stuck during an lvmetad update, lvmetad
will cancel that update after the timeout. The next command
to check the lvmetad will see that lvmetad needs to be
populated because lvmetad will return token of "none" after
a timed out update (same as when lvmetad is not populated
at all after starting.)
If a command gets an error during an lvmetad update, it
will now just quit and leave its updating token in place.
That update will be cancelled after the timeout.
Commit #5b3a4a9 caused the "name" variable to be cleared if
declaration and assignment is on two lines so put it back
so it's on one line for it to work again.
pvmove began processing tags unintentionally from commit,
6d7dc87cb pvmove: use toollib
pvmove works on a single PV, but tags can match multiple PVs.
If we allowed tags, but processed only the first matching PV,
then the resulting PV would be unpredictable.
Also, the current processing code does not allow us to simply
report an error and do nothing if more than one PV matches the tag,
because the command starts processing PVs as they are found,
so it's too late to do nothing if a second PV matches.
If configuration consists of several sources in config cascade
("config cascade" defined in man lvmconfig(8)), lvmconfig displayed
only difference from defaults of the topmost config in the cascade.
Fix lvmconfig to display complete difference, considering all
the configuration in the cascade.
For example, before this patch:
(use_lvmetad=0 set in lvm.conf which differs from defaults)
$ lvmconfig --type diff
global {
use_lvmetad=0
}
(compact_output=1 set on cmd line)
$ lvmconfig --type diff --config report/compact_output=1
report {
compact_output=1
}
(headings=0 set in profile)
$ lvmconfig --type diff --commandprofile test
report {
headings=0
}
(difference in topmost configuration source is displayed)
$ lvmconfig --type diff --commandprofile test --config report/compact_output=1
report {
compact_output=1
}
With this patch applied (the config cascade is merged before looking for
difference from defaults in configuration):
$ lvmconfig --type diff
global {
use_lvmetad=0
}
$ lvmconfig --type diff --config report/compact_output=1
report {
compact_output=1
}
global {
use_lvmetad=0
}
$ lvmconfig --type diff --profile test
report {
headings=0
}
global {
use_lvmetad=0
}
$ lvmconfig --type diff --profile test --config report/compact_output=1
report {
headings=0
compact_output=1
}
global {
use_lvmetad=0
}
Treat loop device created with 'losetup -P' as regular
partitioned device - so if it has partition table,
prevent its usage in commands like 'pvcreate'.
Before 'pvcreate /dev/loop0' could have erased and formated as PV,
after this patch, device is filtered out and cannot be used.
All the variables for sscanf in lvmlockctl.c and lvmlockd-sanlock.c are
zeroed before sscanf call so the failure is detected by seeing the zero
value instead of proper one in subsequent code - so use (void) for
sscanf calls to ignore return value here.
Before this fix, when reporting 'lvm devtypes', the report was
initialized with incorrect reserved values - the ones used for
pvs/vgs/lvs report were used instead of NULL value (because devtypes
doesn't have any reserved values).
For example, trying to (incorrectly) use lv_name for the -S|--select
with lvm devtypes which doesn't have this field at all:
Before this patch (internal error issued):
$ lvm devtypes -S 'lv_name=lvol0'
Internal error: _check_reserved_values_supported: field-specific reserved value of type 0x0 for field not supported
Internal error: dm_report_init_with_selection: trying to register unsupported reserved value type, skipping report selection
DevType MaxParts Description
aoe 16 ATA over Ethernet
ataraid 16 ATA Raid
bcache 1 bcache block device cache
...
With this patch applied (correct error displayed about
unrecognized selection field):
$ lvm devtypes -S 'lv_name=lvol0'
Device Types Fields
-------------------
devtype_name - Name of Device Type exactly as it appears in /proc/devices. [string]
devtype_max_partitions - Maximum number of partitions. (How many device minor numbers get reserved for each device.) [number]
devtype_description - Description of Device Type. [string]
Special Fields
--------------
selected - Set if item passes selection criteria. [number]
help - Show help. [unselectable number]
? - Show help. [unselectable number]
Unrecognised selection field: lv_name
Selection syntax error at 'lv_name=lvol0'.
Use 'help' for selection to get more help.