IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Move code for creation of thin volume into a single place
out of lv_extend(). This allows to drop extra pool arg
for alloc_lv_segment() && lv_extend() and makes code
more easier to read and follow.
Ask for lock the proper LV.
Use the top-most LV to query for locally exclusive lock.
The rest of operations are then using 'lv_info()'
TODO:
Check all devices are reloaded from proper level.
In general any query on lv_is_active is supposed to be running
ona lv_lock_holder() volume.
Instead of segtype->ops->name() introduce lvseg_name().
This also allows us to leave name() function 'empty' for default
return of segtype->name.
TODO: add functions for rest of ops->
--splitcache
Splits only cached LV (also pool could be specified).
Detaches cachepool from cached LV.
--split
Should be univerzal command to split various complex targets.
At this moment it knows cache.
--uncache
Opposite command to --cache. Detaches and DELETES cachepool for
cached LV.
Note: we support thin pool cached metadata device for uncaching.
Also use may specify wither cached LV or association cachepool device
to request split of cache.
The cache mode of a new cache pool is always explicitly
included in the vg metadata. If a cache mode is not
specified on the command line, the cache mode is taken
from lvm.conf allocation/cache_pool_cachemode, which
defaults to "writethrough".
The cache mode can be displayed with lvs -o+cachemode.
We are not using already defined segement type names where we could.
There is a lot of other places in device-mapper and LVM2 we have those
hardcoded so we should better finally have a common interface in
libdevmapper to avoid this.
Use of lv_info() internally in lv_check_not_in_use(),
so it always could use with_open_count properly.
Skip sysfs() testing in open_count == 0 case.
Accept just 'lv' pointer like other functions.
The function has 'built-in' lv_is_active_locally check,
which however is not what we need to check in many place.
For now at least remotely active snapshot merge is
detected and for this case merge on next activation is scheduled.
Move check for snapshot-merge support before archiving.
Split code on 2 paths - with merge_on_activate
using vg_write & vg_commit
and lv_update_reload call for instant merging.
Move printing after backup.
More validations before any thin or cache related conversion begins.
We allow to use and stack:
pool data: cache or raid
pool metadata: raid
pool: linear, striped
cache: linear, striped, raid
thin(extorig): linear, origin, cow, virtual, thin
We use adjusted_mirror_region_size() in two different contexts.
Either on command line -
here we do want to inform user about reduction of size.
Or in pvmove activation context -
here we should only use 'verbose' info.
Failure to copy the 'feature_flags' lvconvert_param to the matching
lv_segment field meant that when a user specified the cachemode argument,
the request was not honored.
Use lv_is_* macros throughout the code base, introducing
lv_is_pvmove, lv_is_locked, lv_is_converting and lv_is_merging.
lv_is_mirror_type no longer includes pvmove.
When testing conversion sanity, we checked lv->status & MIRRORED
which encompasses both old mirrors and raid1 mirrors. But we need to
ban only the old mirrors here hence allow raid1 mirrors.
The lv_type_name function is remnant from old code that reported
only single string for the LV type. LV types are now reported
in a more extended way as keyword list that describe the type
precisely (using lv_layout_and_type fn).
The lv_type_name was used in some error messages to display the
type of the LV so just reinstate the old messages back referencing
the type directly with a string - this is enough for error messages.
They don't need to display the LV type as precisely as it's used
on lvs output (which is optimized for selection anyway).
Fix get_pool_params to only read params.
Add poolmetadataspare option to get_pool_params.
Move all profile code into update_pool_params.
Move recalculate code into pool_manip.c
Revert logic and rename new arg_ functions to:
arg_from_list_is_set()
arg_outside_list_is_set()
When err_found is given, log_error message is automaticaly
printed.
Support --repair and --use-policies with mirrors.
(fixes another regression from lvconvert change for thin and cache).
TODO: the code path for mirror needs update.
Major update of lvconvert code to handle cache and thin.
related targets.
Code tries to unify handling of cache and thin pools.
Better supports lvm2 syntax:
lvconvert --type cache --cachepool vg/pool vg/cache
lvconvert --type thin --thinpool vg/pool vg/extorg
lvconvert --type cache-pool vg/pool
lvconvert --type thin-pool vg/pool
as well as:
lvconvert --cache --cachepool vg/pool vg/cache
lvconvert --thin --thinpool vg/pool vg/extorg
lvconvert --cachepool vg/pool
lvconvert --thinpool vg/pool
While catching much more command line errors.
(Yet couple paths still needs more tests)
Detects as much cmdline errors prior opening VG.
Uses single lvconvert_name_params to convert LV names.
Detects as much incompatibilies in VG prior prompting.
Uses single prompt to confirm whole conversion.
TODO: still the code needs fixes...
Since the type passed LV is changed and content of data detroyed,
query user with prompt to confirm this operation.
Also add a proper wiping of header.
Using '--yes' will skip this prompt:
lvconvert -s --yes vg/lv vg/lvcow
mirror_or_raid_type_requested really checks for mirror type.
Convert macros mirror_or_raid_type_requested() and
snapshot_type_requested() into inline functions.
Since vg_name inside /lib function has already been ignored mostly
except for a few debug prints - make it and official internal API
feature.
vg_name is used only in /tools while the VG is not yet openned,
and when lvresize/lvcreate /lib function is called with VG pointer
already being used, then vg_name becomes irrelevant (it's not been
validated anyway).
So any internal user of lvcreate_params and lvresize_params does not
need to set vg_name pointer and may leave it NULL.
Use NAME_LEN constant to simplify creation of device name.
Since the max size should be already tested in validation,
throw INTERNAL_ERROR if the size of vg/lv is bigger then NAME_LEN.
While polling for snapshot, detect first the snapshot still
exits. It's valid to have multiple polling threads watching
for the same thing and just 1 can 'win' the finish part.
All others should nicely 'fail'.
Warn user before converting volume to different type.
WARNING: Converting vg/lvol0 logical volume to pool's meta/data volume.
THIS WILL DESTROY CONTENT OF LOGICAL VOLUME (filesystem etc.)
Since the content of volume is lost we have to query user to confirm
such operation. If user is 100% sure, he may use '--yes' to avoid prompts.
Delay archiving of metadata until we really start to
update metadata when converting volume into a snapshot.
Archive is not necessary when we abort operation early.
Do not allow conversion of too small LV into a COW snapshot device.
Without this patch snapshot target is generating these kernel
messages before creation fails:
attempt to access beyond end of device
dm-9: rw=16, want=8, limit=2
attempt to access beyond end of device
...
device-mapper: table: 253:11: snapshot: Failed to read snapshot metadata
device-mapper: ioctl: error adding target to table
device-mapper: reload ioctl on failed: Input/output error
Usage of origin as a snapshot 'COW' volume is unsupported.
Without this test lvm2 is able to generate this ugly internal error message.
To test this:
lvcreate -L1 -n lv1 vg
lvcreate -L1 -n lv2 -s vg/lv1
lvcreate -L1 -n lv3 vg
lvconvert -s vg/lv3 vg/lv1
Internal error: LVs (5) != visible LVs (1) + snapshots (1) + internal LVs (0) in VG vg