IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
If there's an activation volume_filter, it might not be possible
to activate the rmeta LVs to wipe them. At least inherit any
LV tags from the parent LV while attempting this.
pvscan autoactivation has its own VG processing implementation,
so it can't properly handle things like foreign or shared VGs,
so make it ignore those VG types (or errors from them) as best
as possible.
Add a FIXME stating that pvscan autoactivation must really be
moved to the standard VG processing by calling process_each_vg
to do activation once the scanning / cache update is finished.
Checking for devices uses is_missing_pv() to check
if there is a device for the PV. is_missing_pv()
is based on the MISSING_PV flag, which does not
always correspond to !pv->dev. When using lvmetad,
a command like:
pvs --config 'devices/filter=["a|/dev/sdb|", "r|.*|"]'
will cause a number of PVs to have NULL pv->dev, but
not the MISSING_PV flag. So, NULL pv->dev needs to
also be checked.
Before executing modprobe for given module name, just check
if the module is not already present in /sys/module.
Useful when checking dm-cache-policy modules as we do not
having matching interface like for targets.
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
WARNING: Couldn't find device for segment belonging to fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
Probably not worth mentioning "segments" here, just state that devices
for an LV can't be all found during the check - it's less mysterious for
user then:
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find all devices for LV fedora/root while checking used and assumed devices.
WARNING: Couldn't find all devices for LV fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
When checking assumed PVs against real devices used for LVs and if
there's no device assigned for an assumed PV (e.g. due to filters),
do log_warn instead of log_error and continue checking LV segments
and associated assumed PVs further, just like we do log_warn elsewhere
in this situation.
This way user will see the warning for each LV which couldn't be
checked completely against real PVs used. Before, we logged only
the very first occurence of missing device for an LV in a VG and we
returned from the function doing this check for all the LVs in VG
immediately which may be a bit misleading because it didn't tell
user about all the other LVs and whether they could be checked
or not.
For example, we have this setup:
[0] fedora/~ # pvs
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
/dev/vda2 fedora lvm2 a-- 19.49g 0
[0] fedora/~ # lvs -o+devices
LV VG Attr LSize Devices
root fedora -wi-ao---- 19.00g /dev/vda2(0)
swap fedora -wi-ao---- 500.00m /dev/vda2(4864)
Before this patch (only the very first LV in a VG is logged to have a
problem while checking used and assumed devices):
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
With this patch applied (all LVs where we hit problem while checking
used and assumed devices are logged and it's warning, not error):
[0] fedora/~ # pvs --config 'devices/filter=["a|/dev/sda|", "r|.*|"]'
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Device for PV Qcxpcy-XgtP-UD3s-PmG0-qLyE-Z0ho-DYsxoz not found or rejected by a filter.
WARNING: Couldn't find device for segment belonging to fedora/root while checking used and assumed devices.
WARNING: Couldn't find device for segment belonging to fedora/swap while checking used and assumed devices.
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
[unknown] fedora lvm2 a-m 19.49g 0
Check that @stats_list and @stats_print returned data in the
_stats_parse_list() and _stats_parse_region() functions before
attempting to operate on region and area values.
This avoids a coverity warning since fgets() could potentially
return no data from the memory buffer returned by the ioctl.
In both cases the ioctl would return an error, preventing these
functions from running, however it is cleaner to test for the
condition explicitly and fail in those cases.
If lvmetad is running, and a command opts to not use it
(--config global/use_lvmetad=0), and the command changes
metadata, then the metadata change is not visible to
lvmetad. Subsequent commands using lvmetad to change
metadata may cause corruption based on the invalid
lvmetad state.
Eventually we can set the disabled state in lvmetad
to prevent this problem, but for now print a warning
about the possibility.