IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Rename original lv_error_when_full field to lv_when_full and also
convert it from binary field to string field displaying three
possible values: "error", "queueu" or "" (blank for undefined).
$ lvs vg/pool vg/pool1 vg/linear_lv -o+lv_when_full
LV VG Attr LSize Data% Meta% WhenFull
linear_lv vg -wi-a----- 4.00m
pool vg twi-aotz-- 4.00m 0.00 0.98 queue
pool1 vg twi-a-tz-- 4.00m 0.00 0.88 error
For -S|--select these synonyms are recognized:
"error" -> "error when full", "error if no space"
"queue" -> "queue when full", "queue if no space"
"" -> "undefined"
Support error_if_no_space feature for thin pools.
Report more info about thinpool status:
(out_of_data (D), metadata_read_only (M), failed (F) also as health
attribute.)
An 'lvconvert --repair $RAID_LV" to replace a failed leg of a multi-segment
RAID10/4/5/6 logical volume can lead to allocation of (parts of) the replacement
image component pair on the physical volume of another image component
(e.g. image 0 allocated on the same PV as image 1 silently impeding resilience).
Patch fixes this severe resilince issue by prohibiting allocation on PVs
already holding other legs of the RAID set. It allows to allocate free space
on any operational PV already holding parts of the image component pair.
Normally, if there are partitions defined on top of device-mapper
device, there should be a device-mapper device created for each
partiton on top of the old one and once the underlying DM device
is used by another devices (partition mappings in this case),
it can't be used as a PV anymore.
However, sometimes, it may happen the partition mappings are
missing - either the partitioning tool is not creating them if
it does not contain full support for device-mapper devices or
the mappings were removed.
Better safe than sorry - check for partition header on DM devs
and filter them out as unsuitable for PVs in case the check is
positive. Whatever the user is doing, let's do our best to prevent
unwanted corruption (...by running pvcreate on top of such device
that would corrupt the partition header).
If pvscan is run with device path instead of major:minor pair and this
device still exists in the system and the device is not visible anymore
(due to a filter that is applied), notify lvmetad properly about this.
This makes it more consistent with respect to existing pvscan with
major:minor which already notifies lvmetad about device that is gone
due to filters.
However, if the device is not in the system anymore, we're not able
to translate the original device path into major:minor pair which
lvmetad needs for its action (lvmetad_pv_gone fn). So in this case,
we still need to use major:minor pair only, not device path. But at
least make "pvscan --cache DevicePath" as near as possible to "pvscan
--cahce <major>:<minor>" functionality.
Also add a note to pvscan man page about this difference when using
pvscan --cache with DevicePath and major:minor pair.
No need to use awk now to get appropriate VGs/LVs, use LVM's
own --select - it's quicker, it removes a need for external
dependency on awk and it's also more readable.
When creating/activating clustered mirrors, we should have cmirrord
available and running. If it's not, we ended up with rather cryptic
errors like:
$ lvcreate -l1 -m1 --type mirror vg
Error locking on node 1: device-mapper: reload ioctl on failed: Invalid argument
Failed to activate new LV.
$ vgchange -ay vg
Error locking on node node 1: device-mapper: reload ioctl on failed: Invalid argument
This patch adds check for cmirror availability and it errors out
properly, also giving a more precise error messge so users are able
to identify the source of the problem easily:
$ lvcreate -l1 -m1 --type mirror vg
Shared cluster mirrors are not available.
$ vgchange -ay vg
Error locking on node 1: Shared cluster mirrors are not available.
Exclusively activated cluster mirror LVs are OK even without cmirrord:
$ vgchange -aey vg
1 logical volume(s) in volume group "vg" now active
The {pv,vg,lv}display *do* use reporting in case "-C|--columns" is used.
The man page was correct, the recognition for the --binary was missing
in the code though!
All the LVM commands are run in mode without lvmetad use (since lvmetad
can't handle duplicates). When we're finished with vgimportclone, we
need to notify lvmetad about changes.
Before this patch (/dev/sda and /dev/sdb contains a copy VG called "vg"):
$ vgimportclone --basevgname vg_snap /dev/sdb
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: Activation disabled. No device-mapper interaction will be attempted.
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
Physical volume "/tmp/snap.zcJ8LCmj/vgimport0" changed 1 physical volume changed / 0 physical volumes not changed
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: Activation disabled. No device-mapper interaction will be attempted.
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
Volume group "vg" successfully changed
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
Volume group "vg" successfully renamed to "vg_snap"
Reading all physical volumes. This may take a while...
Found volume group "vg" using metadata type lvm2
Found volume group "fedora" using metadata type lvm2
$ vgs
VG #PV #LV #SN Attr VSize VFree
fedora 1 2 0 wz--n- 9.50g 0
vg 1 1 0 wz--n- 124.00m 120.00m
(...lvmetad doesn't see the new "vg_snap"!)
With this patch applied:
$ vgimportclone --basevgname vg_snap /dev/sdb
...
WARNING: lvmetad is running but disabled. Restart lvmetad before enabling it!
Volume group "vg" successfully renamed to "vg_snap"
Notifying lvmetad about changes since it was disabled temporarily.
Reading all physical volumes. This may take a while...
Found volume group "vg_snap" using metadata type lvm2
Found volume group "fedora" using metadata type lvm2
Found volume group "vg" using metadata type lvm2
$ vgs
VG #PV #LV #SN Attr VSize VFree
fedora 1 2 0 wz--n- 9.50g 0
vg 1 1 0 wz--n- 124.00m 120.00m
vg_snap 1 1 0 wz--n- 124.00m 120.00m
The "restart lvmetad before enabling it" message is a bit misleading
here - we should probably suppress this one, but we can't suppress
warning messages selectively at the moment and we don't want to lose
other warning/error messages printed...
With current dumpconfig, we can generate lvm.conf easily - we can merge
current lvm.conf with the config given on cmd line:
lvm dumpconfig --mergedconfig --config "..."
This is a bit simpler than using awk and it also avoids problems when some of
the configuration is missing in existing lvm.conf file and hardcoded defaults
are used instead. The dumpconfig handles this transparently.
Under certain circumstances, the selection code can segfault:
$ vgs --select 'pv_name=~/dev/sda' --unbuffered vg0
VG #PV #LV #SN Attr VSize VFree
vg0 6 3 0 wz--n- 744.00m 588.00m
Segmentation fault (core dumped)
The problem here is the use of --ubuffered together with regex used in
selection criteria. If the report output is not buffered, each row is
discarded as soon as it is reported. The bug is in the use of report
handle's memory - in the example above, what happens is:
1) report handle is initialized together with its memory pool
2) selection tree is initialized from selection criteria string
(using the report handle's memory pool!)
2a) this also means the regex is initialized from report handle's mem pool
3) the object (row) is reported
3a) any memory needed for output is intialized out of report handle's mem pool
3b) selection criteria matching is executed - if the regex is checked the
very first time (for the very first row reported), some more memory
allocation happens as regex allocates internal structures "on-demand",
it's allocating from report handle's mem pool (see also step 2a)
4) the report output is executed
5) the object (row) is discarded, meaning discarding all the mem pool
memory used since step 3.
Now, with step 5) we have discarded the regex internal structures from step 3b.
When we execute reporting for another object (row), we're using the same
selection criteria (step 3b), but tihs is second time we're using the regex
and as such, it's already initialized completely. But the regex is missing the
internal structures now as they got discarded in step 5) from previous
object (row) reporting (because we're using "unbuffered" reporting).
To resolve this issue and to prevent any similar future issues where each
object/row memory is discarded after output (the unbuffered reporting) while
selection tree is global for all the object/rows, use separate memory pool
for report's selection.
This patch replaces "struct selection_node *selection_root" in struct
dm_report with new struct selection which contains both "selection_root"
and "mem" for separate mem pool used for selection.
We can change struct dm_report this way as it is not exposed via libdevmapper.
(This patch will have even more meaning for upcoming patches where selection
is used even for non-reporting commands where "internal" reporting and
selection criteria matching happens and where the internal reporting is
not buffered.)
Fix incorrect test in configure which sets --enable-udev-systemd-background-jobs
automatically if proper systemd version is available.
The UDEV_SYSTEMD_BACKGROUND_JOBS variable was not properly set to "yes" in
case systemd is available and we had "maybe" for this variable before.
When we split leg from raid - we take a proper new lock for a new LV.
However for now activation checks only 'existince' of device UUID,
but it's not validating device has a proper name.
As a quick fix call suspend()/resume() to rename after split mirror.
Free (and clear) h.protocol string on daemon_open() error paths
so it's OK for caller to skip calling daemon_close() if returned
h.socket_fd is -1.
Close h.socket_fd in daemon_close() to avoid possible leak.
https://bugzilla.redhat.com/1164234
When chunk size needs to be estimated, the code missed to round
to proper 64kb boundaries (or power of 2 for older thin pool driver).
So for some data and metadata size (i.e. 10GB and 4MB) it resulted
in incorrect chunk size (not being a multiple of 64KB)
Fix it by adding proper rounding and also use 1 routine for 2 places
where the same calculation is made.
Fix also incorrect printed warning that has used 'ffs()'
(which returns first 'least significant' bit in word)
and it was not really giving any useful size info and replace it
with properly estimated chunk size.
Fix regression introduced with a2c1024f6a
_setup_task(mknodes ? name : NULL...
has been replaced with:
_setup_task(type != MKNODES ? name : NULL....
Use '=='
Commit d2c116058e introduced regression
with CLVMD_PATH.
+ CLVMD_PATH="$clvmd_prefix/sbin/clvmd"
test "$prefix" != NONE && clvmd_prefix=$prefix
It has set CLVMD_PATH before clvmd_prefix got its final value.
Move it one line below.
systemd-run is available in systemd>=205. Also, this fix prevents
systemd-specific udev rules in 69-dm-lvm-metad.rules to appear in
case systemd environment is not available - make configure to check
this automatically and use these systemd specific rules only if it
is applicable.
Rework ignore_vg() API so it properly handles
multiple kind of vg_read_error() states.
Skip processing only otherwise valid VG.
Always return ECMD_FAILED when break is detected.
Check sigint_caught() in front of dm iterator loop.
Add stack for _process failing ret codes.
Failed recovery provides different (NULL) VG then FAILED_INCONSISTENT.
Mark it with different failure bit - since FAILED_INCONSISTENT is
supposed to contain something 'usable' (thought inconsistent).
More efficient spare volume creation. Save 1 extra commit
and properly activate this volume according to our cluster
activation rules (using lv_active_change() for this).
Since we 'layer' for cache origin which and we support dropping
cache layer - we need to restore origin name in case
the origin LV is more complex target - i.e. raid.
Drop _corig from name
Cleanup and rename parent -> parent_lv.
When deactivating origin, we may have possibly left table in broken state,
where origin is not active, but snapshot volume is still present.
Let's ensure deactivation of origin detects also all associated
snapshots are inactive - otherwise do not skip deactivation.
(so i.e. 'vgchange -an' would detect errors)
When responding to DM_EVENT_CMD_GET_REGISTERED_DEVICE no longer
ignore threads that have already been unregistered but which
are still present.
This means the caller can unregister a device and poll dmeventd
to ensure the monitoring thread has gone away before removing
the device. If a device was registered and unregistered in quick
succession and then removed, WAITEVENT could run in parallel with
the REMOVE.
Threads are moved to the _thread_registry_unused list when they
are unregistered.
Call check_new_thin_pool() to detect in-use thin-pool.
Save extra reactivation of thin-pool when thin pool is not active.
(it's now a bit more expensive to invoke thin_check for new pools.)
For new pools:
We now active locally exclusively thin-pool as 'public' LV.
Validate transaction_id is till 0.
Deactive.
Prepare create message for thin-pool and exclusively active pool.
Active new thin LV.
And deactivate thin pool if it used to be inactive.
Show some stats with 'lvs'
Display same info for active cache volume and cache-pool.
data% - #used cache blocks/#total cache blocks
meta% - #used metadata blocks/#total metadata blocks
copy% - #dirty/#used cache blocks
TODO: maybe there is a better mapping
- should be seen as first-try-and-see.
New size_mb_arg_with_percent is able to read size_mb_arg
but also it's able to read % values.
Percent parsing is share with int_arg_with_sign_and_percent.
If root has locales with different decimal point then '.'
(i.e. Czech with ',') lets be tolerant and retry with
"C" locales in the case '.' is found during parse of number.
Locales are then restored back.
Support compile type configurable defaults for creation
of sparse volumes.
By default now create 'thin-pools' for sparse volumes.
Use the global/sparse_segtype_default to switch back to old
snapshots if needed.
Apply the same compile logic for newly introduces mirror/raid1 options.
Use segment flags to avoid zeroing of cache, cache pool
snapshot and thin pool segments.
We never want to zero these segment types.
Note:
Snapshot COW and Cache origin are created as stripes
thus are then properly zeroed.
Let the finaly state of zero & wipe_signature to be
resolved later together with all the types.
Don't play with zero assigment and segtype flag
(i.e. thin-pool -Z has different meaning).
Check if the passed options do allow requested zeroing/wiping.
lvcreate without -Z or -W will fallback to warning if the device
cannot be zeroed, however if user requested them explicitely
it will give user error.
Refactor lvcreate code.
Prefer to use arg_outside_list_is_set() so we get automatic 'white-list'
validation of supported options with different segment types.
Drop used lp->cache, lp->cache and use seg_is_cache(), seg_is_thin()
Draw clear border where is the last moment we could change create
segment type.
When segment type is given with --type - do not allow it to be changed
later.
Put together tests related to individual segment types.
Finish cache conversion at proper part of lv_manip code after
the vg_metadata are written - so we could correcly clean-up created
stripe LV for cache volume.
We want to print smarter warning message only when
the zeroing was not provided on the first zeroable segment
of newly created LV.
Put warning within _should_wipe_lv function to avoid reevaluation
of same conditions twice.
Hide creation of temporary LVs and print them only in verbose mode.
e.g. hides confusing message about creation of _pmspare
device during creation of pool.
Ask for lock the proper LV.
Use the top-most LV to query for locally exclusive lock.
The rest of operations are then using 'lv_info()'
TODO:
Check all devices are reloaded from proper level.
In general any query on lv_is_active is supposed to be running
ona lv_lock_holder() volume.
Instead of segtype->ops->name() introduce lvseg_name().
This also allows us to leave name() function 'empty' for default
return of segtype->name.
TODO: add functions for rest of ops->
There was a bug in value and their synonym definition for these two fields
causing selections on these fields to not work correctly - nothing matched
against vg/lv_permissions fields even if selection criteria should have
matched.
Scenario:
$ lvs -o name,lv_permissions vg
LV LPerms
lvol0 read-only
lvol1 writeable
Before this patch:
$ lvs -o name,lv_permissions vg -S 'permissions=read-only'
(blank)
$ lvs -o name,lv_permissions vg -S 'permissions=writeable
(blank)
With this patch applied:
$ lvs -o name,lv_permissions vg -S 'permissions=read-only'
LV LPerms
lvol0 read-only
$ lvs -o name,lv_permissions vg -S 'permissions=writeable'
LV LPerms
lvol1 writeable
Also synonyms match correctly now:
$ lvs -o name,lv_permissions vg -S 'permissions=rw'
LV LPerms
lvol1 writeable
Fix lvm_split that is called when cmd line string is separated into
argv fields to recognize quote chars ('\'" and '"') properly and
when these quotes are used, consider the text within quotes as one
argument, do not separate it based on space characters inside.
The lvm_split is used during processing lvm shell command line or
when calling lvm commands through cmdlib (e.g. dmeventd plugins).
For example, the lvm shell scenario:
Before this patch:
$lvm
lvm> lvs --config 'global{ suffix=0 }'
Parse error at byte 9 (line 1): unexpected token
Failed to set overridden configuration entries.
With this patch applied:
$lvm
lvm> lvs --config 'global{ suffix=0 }'
LV VG Attr LSize Pool Origin Data% Meta% Move Log Cpy%Sync Convert
root fedora -wi-ao---- 9.00g
swap fedora -wi-ao---- 512.00m
(Exactly the same problem is hit when calling LVM commands with
quoted arguments via lvm2cmd lib in dmeventd plugins.)
Bug https://bugzilla.redhat.com/show_bug.cgi?id=843587 is handled better
now - the hang does not occur anymore. There are still error messages
issued though during shutdown if someone stops lvm2-lvmetad.service
manually that lvm2-monitor.service depends on (even during shutdown).
These errors are correct though and will point to incorrect
configuration (still having use_lvmetad=1 in lvm.conf and stopping
lvm2-lvmetad.service manually).
The workaround to prevent the hang is not needed now. So the
'--config "global{use_lvmetad=0}"' is now removed from the
lvm2-monitor.service's ExecStop line.
Introduce pool function for validation of chunk size.
It's good idea to be able to reject invalid chunk size
when entered on command line before we open VG.
Move code to better locations.
Improve test and remove invalid ones
(i.e. no reason to require cache size to be >= then origin).
Correctly comment where the code is doing actual conversion
of other existing volume - we do already a similar thing with
external origins.
Lots of new command line options and combinations is now supported.
Hopefully older syntax still works as well.
lvcreate --cache --cachepool vg/pool -l1
lvcreate --type cache --cachepool vg/pool -l1
lvcreate --type cache-pool vg/pool -l1
lvcreate --type cache-pool --name pool vg -l1
... and many many more ...
Since _pmspare is internal volume move it to
lv_remove_single - so it's automatically removed with
last remove thin-pool.
lv_remove_with_dependencies() is not always used for pool removal.
--splitcache
Splits only cached LV (also pool could be specified).
Detaches cachepool from cached LV.
--split
Should be univerzal command to split various complex targets.
At this moment it knows cache.
--uncache
Opposite command to --cache. Detaches and DELETES cachepool for
cached LV.
Note: we support thin pool cached metadata device for uncaching.
Also use may specify wither cached LV or association cachepool device
to request split of cache.
Over the time lvcreate code has accumulated various hacks.
So try to move that code in right places.
Detect all types early in _lvcreate_params() so functions like
_read_size_params() do not need to change volume types.
Also ultimately respect give volume --type, that its shortcut
(-T, H, -m, -s) and after that options which do type estimation.
(i.e. --cachepool, --thinpool)
Avoid repeative tests - if we know all types are decode at once
place we can 'optimize' number of validations.
Split VG argument collection from processing.
This allows the two different loops through VGs to
be replaced by a single loop.
Replace unused struct cmd_vg and cmd_vg_read() replicator
code with struct vg and vg_read() directly.
[Committed by agk with cosmetic changes and tweaks.]
We use adjusted_mirror_region_size() in two different contexts.
Either on command line -
here we do want to inform user about reduction of size.
Or in pvmove activation context -
here we should only use 'verbose' info.
When requesting to reload an LV imrove this API to
automatically reload its lock holding LV as in cluster
only top-level LVs are addressable with lock.
When vg_ondisk is NULL we do not need to search
through the whole VG to find out the same LV.
NOTE: as of now - VG locking is not enabled as some code parts
are breaking memory locking rules (lvm2app).
Once we enforce VG locking for read-only commands the effect
will be much better for larger VGs.
Move common code for reading and processing
of --persistent arguments for lvcreate and lvchange
into lvmcmdline.
Reuse validate_major_minor() routine for validation.
Don't blindly activate LVs after change in cluster
and instead only local reactivation is supported.
(we have now many limited targets now).
Dropping 'sigint_caught()' handling, since
prompt() is resolving this case itself.
If we want to support conversion of VG to clustered type,
we currently need to relock active LV to get proper DLM lock.
So add extra loop after change of VG clustered attribute
to exlusively activate all active top level LVs.
When doing change -cy -> -cn we should validate LVs are not
active on other cluster nodes - we could be sure about this only
when with local exclusive activation - for other types
we require user to deactivate volumes first.
As a workaround for this limitation there is always
locking_type = 0 which amongs other skip the detection
of active LVs.
FIXME:
clvmd should handle looks for cluster locking type all the time.
Failure to copy the 'feature_flags' lvconvert_param to the matching
lv_segment field meant that when a user specified the cachemode argument,
the request was not honored.
While we could probably reacquire some type of lock when
going from non-clustered to clustered vg, we don't have any
single road back to drop the lock and keep LV active.
For now keep it safe and prohibit conversion when LV
is active in the VG.
Try to enforce consistent macro usage along these lines:
lv_is_mirror - mirror that uses the original dm-raid1 implementation
(segment type "mirror")
lv_is_mirror_type - also includes internal mirror image and log LVs
lv_is_raid - raid volume that uses the new dm-raid implementation
(segment type "raid")
lv_is_raid_type - also includes internal raid image / log / metadata LVs
lv_is_mirrored - LV is mirrored using either kernel implementation
(excludes non-mirror modes like raid5 etc.)
lv_is_pvmove - internal pvmove volume
Use lv_is_* macros throughout the code base, introducing
lv_is_pvmove, lv_is_locked, lv_is_converting and lv_is_merging.
lv_is_mirror_type no longer includes pvmove.
Fix rename operation for snapshot (cow) LV.
Only the snapshot's origin has the lock and by mistake suspend
and resume has been called for the snapshot LV.
This further made volumes unusable in cluster.
So instead of suspend and resuming list of LVs,
we need to just suspend and resume origin.
As the sequence write/suspend/commit/resume
is widely used in lvm2 code base - move it to
new lv_update_and_reload function.
Fixing problem, when user sets volume_list and excludes thin pools
from activation. In this case pool return 'success' for skipped activation.
We need to really check the volume it is actually active to properly
to remove queued pool messages. Otherwise the lvm2 and kernel
metadata started to go async since lvm2 believed, messages were submitted.
Add also better check for threshold when create a new thin volume.
In this case we require local activation of thin pool so we are able
to check pool fullness.
The 'lv_type' field name was a bit misleading. Better one is 'lv_role'
since this fields describes what's the actual use of the LV currently -
its 'role'.
Sort out the lvresize calculation code to handle size changes
specified as physical extents as well as logical extents
and to process mirror resizing and raid extensions correctly.
The 'approx alloc' option was masking the underlying problem.
When testing conversion sanity, we checked lv->status & MIRRORED
which encompasses both old mirrors and raid1 mirrors. But we need to
ban only the old mirrors here hence allow raid1 mirrors.
The maximum stripe size is equal to the volume group PE size. If that
size falls below the STRIPE_SIZE_MIN, the creation of RAID 4/5/6 volumes
becomes impossible. (The kernel will fail to load a RAID 4/5/6 mapping
table with a stripe size less than STRIPE_SIZE_MIN.) So, we report an
error if it is attempted.
This is very rare because reducing the PE size down that far limits the
size of the PV below that of modern devices.
The lv_layout and lv_type fields together help with LV identification.
We can do basic identification using the lv_attr field which provides
very condensed view. In contrast to that, the new lv_layout and lv_type
fields provide more detialed information on exact layout and type used
for LVs.
For top-level LVs which are pure types not combined with any
other LV types, the lv_layout value is equal to lv_type value.
For non-top-level LVs which may be combined with other types,
the lv_layout describes the underlying layout used, while the
lv_type describes the use/type/usage of the LV.
These two new fields are both string lists so selection (-S/--select)
criteria can be defined using the list operators easily:
[] for strict matching
{} for subset matching.
For example, let's consider this:
$ lvs -a -o name,vg_name,lv_attr,layout,type
LV VG Attr Layout Type
[lvol1_pmspare] vg ewi------- linear metadata,pool,spare
pool vg twi-a-tz-- pool,thin pool,thin
[pool_tdata] vg rwi-aor--- level10,raid data,pool,thin
[pool_tdata_rimage_0] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_1] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_2] vg iwi-aor--- linear image,raid
[pool_tdata_rimage_3] vg iwi-aor--- linear image,raid
[pool_tdata_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_1] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_2] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_3] vg ewi-aor--- linear metadata,raid
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
[pool_tmeta_rimage_0] vg iwi-aor--- linear image,raid
[pool_tmeta_rimage_1] vg iwi-aor--- linear image,raid
[pool_tmeta_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tmeta_rmeta_1] vg ewi-aor--- linear metadata,raid
thin_snap1 vg Vwi---tz-k thin snapshot,thin
thin_snap2 vg Vwi---tz-k thin snapshot,thin
thin_vol1 vg Vwi-a-tz-- thin thin
thin_vol2 vg Vwi-a-tz-- thin multiple,origin,thin
Which is a situation with thin pool, thin volumes and thin snapshots.
We can see internal 'pool_tdata' volume that makes up thin pool has
actually a level10 raid layout and the internal 'pool_tmeta' has
level1 raid layout. Also, we can see that 'thin_snap1' and 'thin_snap2'
are both thin snapshots while 'thin_vol1' is thin origin (having
multiple snapshots).
Such reporting scheme provides much better base for selection criteria
in addition to providing more detailed information, for example:
$ lvs -a -o name,vg_name,lv_attr,layout,type -S 'type=metadata'
LV VG Attr Layout Type
[lvol1_pmspare] vg ewi------- linear metadata,pool,spare
[pool_tdata_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_1] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_2] vg ewi-aor--- linear metadata,raid
[pool_tdata_rmeta_3] vg ewi-aor--- linear metadata,raid
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
[pool_tmeta_rmeta_0] vg ewi-aor--- linear metadata,raid
[pool_tmeta_rmeta_1] vg ewi-aor--- linear metadata,raid
(selected all LVs which are related to metadata of any type)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'type={metadata,thin}'
LV VG Attr Layout Type
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs which hold metadata related to thin)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'type={thin,snapshot}'
LV VG Attr Layout Type
thin_snap1 vg Vwi---tz-k thin snapshot,thin
thin_snap2 vg Vwi---tz-k thin snapshot,thin
(selected all LVs which are thin snapshots)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'layout=raid'
LV VG Attr Layout Type
[pool_tdata] vg rwi-aor--- level10,raid data,pool,thin
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs with raid layout, any raid layout)
lvs -a -o name,vg_name,lv_attr,layout,type -S 'layout={raid,level1}'
LV VG Attr Layout Type
[pool_tmeta] vg ewi-aor--- level1,raid metadata,pool,thin
(selected all LVs with raid level1 layout exactly)
And so on...
_pvcreate_check() has two missing requirements:
After refreshing filters there must be a rescan.
(Otherwise the persistent filter may remain empty.)
After wiping a signature, the filters must be refreshed.
(A device that was previously excluded by the filter due to
its signature might now need to be included.)
If several devices are added at once, the repeated scanning isn't
strictly needed, but we can address that later as part of the command
processing restructuring (by grouping the devices).
Replace the new pvcreate code added by commit
54685c20fc "filters: fix regression caused
by commit e80884cd080cad7e10be4588e3493b9000649426"
with this change to _pvcreate_check().
The filter refresh problem dates back to commit
acb4b5e4de "Fix pvcreate device check."
If using persistent filter and we're refreshing filters (just like we
do for pvcreate now after commit 54685c20fc),
we can't rely on getting the primary device of the partition from the cache
as such device could be already filtered by persistent filter and we get
a device cache lookup failure for such device.
For example:
$ lvm dumpconfig --type diff
devices {
obtain_device_list_from_udev=0
}
$lsblk /dev/sda
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:0 0 128M 0 disk
`-sda1 8:1 0 127M 0 part
$cat /etc/lvm/cache/.cache | grep sda
"/dev/sda1",
$pvcreate /dev/sda1
dev_is_mpath: failed to get device for 8:1
Physical volume "/dev/sda1" successfully created
The problematic part of the code called dev_cache_get_by_devt
to get the device for the device number supplied. Then the code
used dev_name(dev) to get the name which is then used in check
whether there's any mpath on top of this dev...
This patch uses sysfs to get the base name for the partition
instead, hence avoiding the device cache which is a correct
approach here.
The message "Cannot deactivate remotely exclusive device locally." makes
sense only for clustered LV. If the LV is non-clustered, then it's
always exclusive by definition and if it's already deactivated, this
message pops up inappropriately as those two conditions are met.
So issue the message only if the conditions are met AND we have clustered VG.
With cmirrord, we can do pvmove of clustered mirror. The code checking
suitability of LVs on the PV being moved issued a message if a mirror
LV was found and the VG was clustered. However, the actual pvmove did
work correctly.
The top-level mirror LV is actually skipped in the code since it's
always layered on top of internal LVs making up the mirror LV and for pvmove
we consider these internal devices only as they're actually layered on
top of concrete PVs then. But we don't need to issue any message here
about skipping the top-level mirror LV - it's misleading here.