IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Previous fix missed the fact the we do query for 'percent' with
seg value either set or unset (API overload...)
When 'seg' was unset, we still issue flush with status.
Fix it by cheking segtype by target_type.
As we check for segtype - we could also skip whole percentage
if the 'segtype' is unknown by code directly.
Reported-by: Ming-Hung Tsai <mingnus gmail com
It's correct to have a DM device that has no DM UUID assigned
so no need to issue error message in this case. Also, if the
device doesn't have DM UUID, it's also clear it's not an LVM LV
(...when looking for VGID/LVID while creating VGID/LVID indices
in dev cache).
For example:
$ dmsetup create test --table "0 1 linear /dev/sda 0"
And there's no PV in the system.
Before this patch (spurious error message issued):
$ pvs
_get_sysfs_value: /sys/dev/block/253:2/dm/uuid: no value
With this patch applied (no spurious error message):
$ pvs
If we're using persistent .cache file, we're reading this file instead
of traversing the /dev content. Fix missing indexing by VGID and LVID
here - hook this into persistent_filter_load where we populate device
cache from persistent .cache file instead of scanning /dev.
For example, inducing situation in which we warn about different device
actually used than what LVM thinks should be used based on metadata:
$ lsblk -s /dev/vg/lvol0
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
vg-lvol0 253:4 0 124M 0 lvm
`-loop1 7:1 0 128M 0 loop
$ lvmconfig --type diff
global {
use_lvmetad=0
}
devices {
obtain_device_list_from_udev=0
}
(obtain_device_list_from_udev=0 also means the persistent .cache file is used)
Before this patch - pvs is fine as it does the dev scan, but lvs relies
on persistent .cache file and it misses the VGID/LVID indices to check
and warn about incorrect devices used:
$ pvs
Found duplicate PV B9gXTHkIdEIiMVwcOoT2LX3Ywh4YIHgR: using /dev/loop0 not /dev/loop1
Using duplicate PV /dev/loop0 without holders, ignoring /dev/loop1
WARNING: Device mismatch detected for vg/lvol0 which is accessing /dev/loop1 instead of /dev/loop0.
PV VG Fmt Attr PSize PFree
/dev/loop0 vg lvm2 a-- 124.00m 0
$ lvs
Found duplicate PV B9gXTHkIdEIiMVwcOoT2LX3Ywh4YIHgR: using /dev/loop0 not /dev/loop1
Using duplicate PV /dev/loop0 without holders, ignoring /dev/loop1
LV VG Attr LSize
lvol0 vg -wi-a----- 124.00m
With this patch applied - both pvs and lvs is fine - the indices are
always created correctly (lvs just an example here, other LVM commands
that rely on persistent .cache file are fixed with this patch too):
$ pvs
Found duplicate PV B9gXTHkIdEIiMVwcOoT2LX3Ywh4YIHgR: using /dev/loop0 not /dev/loop1
Using duplicate PV /dev/loop0 without holders, ignoring /dev/loop1
WARNING: Device mismatch detected for vg/lvol0 which is accessing /dev/loop1 instead of /dev/loop0.
PV VG Fmt Attr PSize PFree
/dev/loop0 vg lvm2 a-- 124.00m 0
$ lvs
Found duplicate PV B9gXTHkIdEIiMVwcOoT2LX3Ywh4YIHgR: using /dev/loop0 not /dev/loop1
Using duplicate PV /dev/loop0 without holders, ignoring /dev/loop1
WARNING: Device mismatch detected for vg/lvol0 which is accessing /dev/loop1 instead of /dev/loop0.
LV VG Attr LSize
lvol0 vg -wi-a----- 124.00m
It's possible that while a device is already referenced in sysfs, the node
is not yet in /dev directory.
This may happen in some rare cases right after LVs get created - we sync
with udev (or alternatively we create /dev content ourselves) while VG
lock is held. However, dev scan is done without VG lock so devices may
already be in sysfs, but /dev may not be updated yet if we call LVM command
right after LV creation (so the fact that fs_unlock is done within VG
lock is not usable here much). This is not a problem with devtmpfs as
there's at least kernel name for device in /dev as soon as the sysfs
item exists, but we still support environments without devtmpfs or
where different directory for dev nodes is used (e.g. our test suite).
This patch covers these situations by tracking such devices in
_cache.sysfs_only_names helper hash for the vgid/lvid check to work still.
This also resolves commit 6129d2e64d
which was then reverted by commit 109b7e2095
due to performance issues it may have brought (...and it didn't resolve
the problem fully anyway).
dmeventd daemon may call further code itself that looks at /dev, e.g.
via dmeventd_lvm2_command call. We need to have a consistent view of
the /dev content at that time. Therefore, sync /dev content before
calling monitoring hook which contacts dmeventd.
This problem was quite hidden before, but now it has manifested itself
because of recent additions to dev-cache code where we started looking
at device holders as seen in sysfs. What happened here was that the
device was already in sysfs, but not yet under /dev and this triggered
the new error message sometimes:
log_error("%s: failed to find associated device structure for holder %s.", devname, devpath);
This problem has manifested recently in our api/pytest.sh test from
testsuite where we create thin pool LVs and thin LVs and hence it also
causes dmeventd to be used as well and these error messages were
visible there.
UUID for LV is either "LVM-<vg_uuid><lv_uuid>" or "LVM-<vg_uuid><lv_uuid>-<suffix>".
The code before just checked the length of the UUID based on the first
template, not the variant with suffix - so LVs with this suffix were not
processed properly.
For example a thin pool LV (as an example of an LV that contains
sub LVs where UUIDs have suffixes):
[0] fedora/~ # lsblk -s /dev/vg/lvol1
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
vg-lvol1 253:8 0 4M 0 lvm
`-vg-pool-tpool 253:6 0 116M 0 lvm
|-vg-pool_tmeta 253:2 0 4M 0 lvm
| `-sda 8:0 0 128M 0 disk
`-vg-pool_tdata 253:3 0 116M 0 lvm
`-sda 8:0 0 128M 0 disk
Before this patch (spurious warning message about device mismatch):
[0] fedora/~ # pvs
WARNING: Device mismatch detected for vg/lvol1 which is accessing /dev/mapper/vg-pool-tpool instead of (null).
PV VG Fmt Attr PSize PFree
/dev/sda vg lvm2 a-- 124.00m 0
With this patch applied (no spurious warning message about device mismatch):
[0] fedora/~ # pvs
PV VG Fmt Attr PSize PFree
/dev/sda vg lvm2 a-- 124.00m 0
To help out with debug, when an exception is thrown in the dbus service we
will dump all the information we have on the last 16 commands that were
executed along with the stack strace.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
With commit 2d5dc6512e the dbus server
no longer needs to utilize udev to know when to update its internal
state.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
Check if the value we read from sysfs is not blank and replace the '\n'
at the end only when needed ('\n' should usually be there for sysfs values,
but better check this).
It's possible for an LVM LV to use a device during activation which
then differs from device which LVM assumes based on metadata later on.
For example, such device mismatch can occur if LVM doesn't have
complete view of devices during activation or if filters are
misbehaving or they're incorrectly set during activation.
This patch adds code that can detect this mismatch by creating
VG UUID and LV UUID index while scanning devices for device cache.
The VG UUID index maps VG UUID to a device list. Each device in the
list has a device layered above as a holder which is an LVM LV device
and for which we know the VG UUID (and similarly for LV UUID index).
We can acquire VG and LV UUID by reading /sys/block/<dm_dev_name>/dm/uuid.
So these indices represent the actual state of PV device use in
the system by LVs and then we compare that to what LVM assumes
based on metadata.
For example:
[0] fedora/~ # lsblk /dev/sdq /dev/sdr /dev/sds /dev/sdt
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sdq 65:0 0 104M 0 disk
|-vg-lvol0 253:2 0 200M 0 lvm
`-mpath_dev1 253:3 0 104M 0 mpath
sdr 65:16 0 104M 0 disk
`-mpath_dev1 253:3 0 104M 0 mpath
sds 65:32 0 104M 0 disk
|-vg-lvol0 253:2 0 200M 0 lvm
`-mpath_dev2 253:4 0 104M 0 mpath
sdt 65:48 0 104M 0 disk
`-mpath_dev2 253:4 0 104M 0 mpath
In this case the vg-lvol0 is mapped onto sdq and sds becauset this is
what was available and seen during activation. Then later on, sdr and
sdt appeared and mpath devices were created out of sdq+sdr (mpath_dev1)
and sds+sdt (mpath_dev2). Now, LVM assumes (correctly) that mpath_dev1
and mpath_dev2 are the PVs that should be used, not the mpath
components (sdq/sdr, sds/sdt).
[0] fedora/~ # pvs
Found duplicate PV xSUix1GJ2SK82ACFuKzFLAQi8xMfFxnO: using /dev/mapper/mpath_dev1 not /dev/sdq
Using duplicate PV /dev/mapper/mpath_dev1 from subsystem DM, replacing /dev/sdq
Found duplicate PV MvHyMVabtSqr33AbkUrobq1LjP8oiTRm: using /dev/mapper/mpath_dev2 not /dev/sds
Using duplicate PV /dev/mapper/mpath_dev2 from subsystem DM, ignoring /dev/sds
WARNING: Device mismatch detected for vg/lvol0 which is accessing /dev/sdq, /dev/sds instead of /dev/mapper/mpath_dev1, /dev/mapper/mpath_dev2.
PV VG Fmt Attr PSize PFree
/dev/mapper/mpath_dev1 vg lvm2 a-- 100.00m 0
/dev/mapper/mpath_dev2 vg lvm2 a-- 100.00m 0
If we're using non-standard /dev layout so we can't get the dm-X name
easily, we can't also look at the /sys/blocl/dm-X/dev to get the major:minor
pair. Use "stat" in this case even though it triggers automounts
(but there's no better way for now).
The /proc/self/mountinfo is not bound to device names like /proc/mounts
and it uses major:minor pairs instead.
This fixes a situation in which a volume is mounted and then renamed
later on - that makes /proc/mounts unreliable when detecting mounted
volumes.
See also https://bugzilla.redhat.com/show_bug.cgi?id=1196910.
Commit b64703401d cause regression
when handling stacked resize of pool metadata volume that would
be a raid LV.
Fix it by properly setting up size also for layer extension.