dmeventd daemon may call further code itself that looks at /dev, e.g.
via dmeventd_lvm2_command call. We need to have a consistent view of
the /dev content at that time. Therefore, sync /dev content before
calling monitoring hook which contacts dmeventd.
This problem was quite hidden before, but now it has manifested itself
because of recent additions to dev-cache code where we started looking
at device holders as seen in sysfs. What happened here was that the
device was already in sysfs, but not yet under /dev and this triggered
the new error message sometimes:
log_error("%s: failed to find associated device structure for holder %s.", devname, devpath);
This problem has manifested recently in our api/pytest.sh test from
testsuite where we create thin pool LVs and thin LVs and hence it also
causes dmeventd to be used as well and these error messages were
visible there.
UUID for LV is either "LVM-<vg_uuid><lv_uuid>" or "LVM-<vg_uuid><lv_uuid>-<suffix>".
The code before just checked the length of the UUID based on the first
template, not the variant with suffix - so LVs with this suffix were not
processed properly.
For example a thin pool LV (as an example of an LV that contains
sub LVs where UUIDs have suffixes):
[0] fedora/~ # lsblk -s /dev/vg/lvol1
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
vg-lvol1 253:8 0 4M 0 lvm
`-vg-pool-tpool 253:6 0 116M 0 lvm
|-vg-pool_tmeta 253:2 0 4M 0 lvm
| `-sda 8:0 0 128M 0 disk
`-vg-pool_tdata 253:3 0 116M 0 lvm
`-sda 8:0 0 128M 0 disk
Before this patch (spurious warning message about device mismatch):
[0] fedora/~ # pvs
WARNING: Device mismatch detected for vg/lvol1 which is accessing /dev/mapper/vg-pool-tpool instead of (null).
PV VG Fmt Attr PSize PFree
/dev/sda vg lvm2 a-- 124.00m 0
With this patch applied (no spurious warning message about device mismatch):
[0] fedora/~ # pvs
PV VG Fmt Attr PSize PFree
/dev/sda vg lvm2 a-- 124.00m 0
To help out with debug, when an exception is thrown in the dbus service we
will dump all the information we have on the last 16 commands that were
executed along with the stack strace.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
With commit 2d5dc6512e the dbus server
no longer needs to utilize udev to know when to update its internal
state.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
Check if the value we read from sysfs is not blank and replace the '\n'
at the end only when needed ('\n' should usually be there for sysfs values,
but better check this).
It's possible for an LVM LV to use a device during activation which
then differs from device which LVM assumes based on metadata later on.
For example, such device mismatch can occur if LVM doesn't have
complete view of devices during activation or if filters are
misbehaving or they're incorrectly set during activation.
This patch adds code that can detect this mismatch by creating
VG UUID and LV UUID index while scanning devices for device cache.
The VG UUID index maps VG UUID to a device list. Each device in the
list has a device layered above as a holder which is an LVM LV device
and for which we know the VG UUID (and similarly for LV UUID index).
We can acquire VG and LV UUID by reading /sys/block/<dm_dev_name>/dm/uuid.
So these indices represent the actual state of PV device use in
the system by LVs and then we compare that to what LVM assumes
based on metadata.
For example:
[0] fedora/~ # lsblk /dev/sdq /dev/sdr /dev/sds /dev/sdt
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sdq 65:0 0 104M 0 disk
|-vg-lvol0 253:2 0 200M 0 lvm
`-mpath_dev1 253:3 0 104M 0 mpath
sdr 65:16 0 104M 0 disk
`-mpath_dev1 253:3 0 104M 0 mpath
sds 65:32 0 104M 0 disk
|-vg-lvol0 253:2 0 200M 0 lvm
`-mpath_dev2 253:4 0 104M 0 mpath
sdt 65:48 0 104M 0 disk
`-mpath_dev2 253:4 0 104M 0 mpath
In this case the vg-lvol0 is mapped onto sdq and sds becauset this is
what was available and seen during activation. Then later on, sdr and
sdt appeared and mpath devices were created out of sdq+sdr (mpath_dev1)
and sds+sdt (mpath_dev2). Now, LVM assumes (correctly) that mpath_dev1
and mpath_dev2 are the PVs that should be used, not the mpath
components (sdq/sdr, sds/sdt).
[0] fedora/~ # pvs
Found duplicate PV xSUix1GJ2SK82ACFuKzFLAQi8xMfFxnO: using /dev/mapper/mpath_dev1 not /dev/sdq
Using duplicate PV /dev/mapper/mpath_dev1 from subsystem DM, replacing /dev/sdq
Found duplicate PV MvHyMVabtSqr33AbkUrobq1LjP8oiTRm: using /dev/mapper/mpath_dev2 not /dev/sds
Using duplicate PV /dev/mapper/mpath_dev2 from subsystem DM, ignoring /dev/sds
WARNING: Device mismatch detected for vg/lvol0 which is accessing /dev/sdq, /dev/sds instead of /dev/mapper/mpath_dev1, /dev/mapper/mpath_dev2.
PV VG Fmt Attr PSize PFree
/dev/mapper/mpath_dev1 vg lvm2 a-- 100.00m 0
/dev/mapper/mpath_dev2 vg lvm2 a-- 100.00m 0
If we're using non-standard /dev layout so we can't get the dm-X name
easily, we can't also look at the /sys/blocl/dm-X/dev to get the major:minor
pair. Use "stat" in this case even though it triggers automounts
(but there's no better way for now).
The /proc/self/mountinfo is not bound to device names like /proc/mounts
and it uses major:minor pairs instead.
This fixes a situation in which a volume is mounted and then renamed
later on - that makes /proc/mounts unreliable when detecting mounted
volumes.
See also https://bugzilla.redhat.com/show_bug.cgi?id=1196910.
Commit b64703401d cause regression
when handling stacked resize of pool metadata volume that would
be a raid LV.
Fix it by properly setting up size also for layer extension.
Allow pvchange and pvresize to process exported VGs,
and have them check for the exported state in their
single function.
Previously, the exported VG state would trigger a
failure in vg_read()/ignore_vg() because the VGs are
being read with READ_FOR_UPDATE. Because these commands
read all VGs to search for the intended PVs, any
exported VG would trigger a failure, even if it was
not related to the intended PV.
Use <> around user entered option parameters to make it visually
different (just like we use Italic style in man page).
TODO:
In the future we should consistently provide such notation and
possibly generate it automagically from some internal data structures.
Preferably for man pages as well so we report actual set of supported