IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Make the data_alignment variable 64 bits so it
can hold the invalid command line arg used in
pvreate-usage.sh pvcreate --dataalignment 1e.
On 32 bit arches, the smaller variable wouldn't
hold the invalid value so the error would not
trigger as expected by the test.
"pvcreate_each_params" was a temporary name used
to transition from the old "pvcreate_params".
Remove the old pvcreate_params struct and rename the
new pvcreate_each_params struct to pvcreate_params.
Rename various pvcreate_each_params terms to simply
pvcreate_params.
Use the new pvcreate_each_device() function from
toollib, previously added for pvcreate, in place
of the old pvcreate_vol().
This also requires shifting the location where the
lock is acquired for the new VG name. The lock for
the new VG is supposed to be acquired before pvcreate.
This means splitting the vg_lock_newname() out of
vg_create(), and calling vg_lock_newname() directly
before pvcreate, and then calling the remainder of
vg_create() after pvcreate.
The new function vg_lock_and_create() now does
vg_lock_newname() + vg_create(), like the previous
version of vg_create().
The lock on the new VG name is released before the
pvcreate and reacquired after the pvcreate because
pvcreate needs to reset lvmcache, which doesn't work
when locks are held. An exception could likely be
made for the new VG name lock, which would allow
vgcreate to hold the new VG name lock across the
pvcreate step.
This is common code for handling PV create/remove
that can be shared by pvcreate/vgcreate/vgextend/pvremove.
This does not change any commands to use the new code.
- Pull out the hidden equivalent of process_each_pv
into an actual top level process_each_pv.
- Pull the prompts to the top level, and do not
run any prompts while locks are held.
The orphan lock is reacquired after any prompts are
done, and the devices being created are checked for
any change made while the lock was not held.
Previously, pvcreate_vol() was the shared function for
creating a PV for pvcreate, vgcreate, vgextend.
Now, it will be toollib function pvcreate_each_device().
pvcreate_vol() was called effectively as a helper, from
within vgcreate and vgextend code paths.
pvcreate_each_device() will be called at the same level
as other process_each functions.
One of the main problems with pvcreate_vol() is that
it included a hidden equivalent of process_each_pv for
each device being created:
pvcreate_vol() -> _pvcreate_check() ->
find_pv_by_name() -> get_pvs() ->
get_pvs_internal() -> _get_pvs() -> get_vgids() ->
/* equivalent to process_each_pv */
dm_list_iterate_items(vgids)
vg = vg_read_internal()
dm_list_iterate_items(&vg->pvs)
pvcreate_each_device() reorganizes the code so that
each-VG-each-PV loop is done once, and uses the standard
process_each_pv function at the top level of the function.
The vg->pv_write_list contains pv_list structs for which
vg_write() should call pv_write().
The new list will replace vg->pvs_to_write that contains
vg_to_create structs which are used to perform higher-level
pvcreate-related operations. The higher level pvcreate
operations will be moved out of vg_write() to higher levels.
Reshuffle messages during pvremove.
Always print WARNING: when PV is in use so using options
--force --force doesn't make this important user
notification go away.
Simplify variable 'used' usage (so older gcc doesn't warn
about the use of unitilizied variable).
Add some '.' into messages.
When update fails in suspend() (sending of messages
fails because metadata space is full) call resume(),
so the locking sequence works properly for clustering.
Also failing deactivation should unlock memory.
Fix reporting of Fail thin-pool target status
as attr[8] letter 'F'.
Report 'needs_check' status from thin-pool target via
attr field [4] (letter 'c'/'C'), and also via CheckNeeded field.
TODO: think about better name here?
TODO: lots of prop_not_implemented_set
Ask for confirmation when using pvcreate/pvremove on a PV which is
marked as belonging to a VG, just like we do in case of a PV which
belongs to known VG:
$ pvcreate -ff /dev/sda
Really INITIALIZE physical volume "/dev/sda" that is marked as belonging to a VG [y/n]? n
/dev/sda: physical volume not initialized
$ pvremove -ff /dev/sda
Really WIPE LABELS from physical volume "/dev/sda" that is marked as belonging to a VG [y/n]? n
/dev/sda: physical volume label not removed
The host that owns foreign VGs is responsible for fixing up PV_EXT_USED
flag - the same already applies to repairing any inconsistent VG.
This patch also moves the iteration over vg->pvs inside
_check_or_repair_pv_ext fn - it's cleaner this way.
pv->vg is not set yet during pvcreate processing. Use pv->fmt instead to
check for these fake PVs (all normal PVs have format defined, devices
which are not PVs don't have this set).
This fixes commit 0000db7f98.
Some of the PVs are not even orphan PVs - they're fake PVs - this can
happen if we're listing all devices with "pvs -a". Such PV must not
be marked as used.
The same check as we already do for orphan PVs, just the other way
round now: if the PV is surely part of some VG and any PV the VG
contains does not have the PV_EXT_USED flag set, repair it.
For example - /dev/sda here is in VG vg and it's incorrectly not
marked as used by PV_EXT_USED flag:
pvs --binary -o pv_ext_vsn,pv_in_use
WARNING: Volume Group vg is not consistent.
WARNING: Repairing Physical Volume /dev/sda that is in Volume Group vg but not marked as used.
PV VG Fmt Attr PSize PFree ExtVsn PInUse
/dev/sda vg lvm2 a-- 124.00m 124.00m 2 1
PV header extension versions:
0 - the original PV without any extensions
1 - bootloader area support added
2 - PV_EXT_USED flag support added
So do the associated checks related to PV_EXT_USED flag only if
PV header extension found is of version 2 and higher.
If we know that the PV is orphan, meaning there's at least one MDA on
that PV which does not reference any VG and at the same time there's
PV_EXT_USED flag set, we're certainly in an inconsistent state and we
need to fix this.
For example, such situation can happen during vgremove/vgreduce if we
removed/reduced the VG, but we haven't written PV headers yet because
vgremove stopped abruptly for whatever reason just before writing new
PV headers with updated state, including PV extension flags (and so the
PV_EXT_USED flag).
However, in case the PV has no MDAs at all, we can't double-check
whether the PV_EXT_USED is correct or not - if that PV is marked
as used, it's either:
- really used (but other disks with MDAs are missing)
- or the error state as described above is hit
User needs to overwrite the PV header directly if it's really clear
the PV having no MDAs does not belong to any VG and at the same time
it's still marked as being in use (pvcreate -ff <dev_name> will fix this).
For example - /dev/sda here has 1 MDA, orphan and is incorrectly marked
with PV_EXT_USED flag:
$ pvs --binary -o+pv_in_use
WARNING: Found inconsistent standalone Physical Volumes.
WARNING: Repairing flag incorrectly marking Physical Volume /dev/sda as used.
PV VG Fmt Attr PSize PFree InUse
/dev/sda lvm2 --- 128.00m 128.00m 0
Scenario:
$ pvcreate /dev/sda
Physical volume "/dev/sda" successfully created
We're adding the PV to a VG.
Before this patch:
$ vgcreate vg /dev/sda
Physical volume "/dev/sda" successfully created
Volume group "vg" successfully created
With this path applied:
$ vgcreate vg /dev/sda
Volume group "vg" successfully created
...and verbose log containing: "Physical volume "/dev/sda" successfully written"
Make sure we won't use a PV that is already marked as used. Normally,
VG metadata would stop us from doing that, but we can run into a
situation where such metadata is missing because PVs with MDAs
are missing and the PVs left are the ones with 0 MDAs.
(/dev/sda in this example has 0 MDAs and it belongs to a VG,
but other PVs with MDA are missing)
$ pvs -o pv_name,pv_mda_count /dev/sda
PV #PMda
/dev/sda 0
$ pvcreate /dev/sda
PV '/dev/sda' is marked as belonging to a VG but its metadata is missing.
Can't initialize PV '/dev/sda' without -ff.
$ pvchange -u /dev/sda
PV '/dev/sda' is marked as belonging to a VG but its metadata is missing.
Can't change PV '/dev/sda' without -ff.
Physical volume /dev/sda not changed
0 physical volumes changed / 1 physical volume not changed
$ pvremove /dev/sda
PV '/dev/sda' is marked as belonging to a VG but its metadata is missing.
(If you are certain you need pvremove, then confirm by using --force twice.)
$ vgcreate vg /dev/sda
Physical volume '/dev/sda' is marked as belonging to a VG but its metadata is missing.
Unable to add physical volume '/dev/sda' to volume group 'vg'.
We'll use this struct in subsequent patches for PVs which should
be rewritten, not just created. So rename struct pv_to_create to
struct pv_to_write for clarity.
Address this gcc warning:
metadata/lv.c:243: warning: initialized field overwritten
metadata/lv.c:243: warning: (near initialization for 'status.seg_status')
Present with e.g.: gcc version 4.3.2 (Debian 4.3.2-1.1)
Simplify calculation of extents rounding needed for
segment size.
Segment size has to divisible by 'extent count' needed to contain
whole stripe. LVM currently does not support stripes across segment.
In case the stripe size is bigger then extent size,
require bigger rounding.
The extent size must fits all blocks in 4294967295 sectors
(in 512b units) this is 1/2 KiB less then 2TiB.
So while previous statement 'suggested' 2TiB is still acceptable value,
make it clear it's not.
As now we support any multiples of 128KB as extent size -
values like 2047G will still 'flow-in' otherwise the largest power-of-2
supported value is 1TiB.
With 1TiB user needs 8388608 extents for 8EiB device.
(FYI such device is already unusable with todays glibc-2.22.90-27)
4GiB extent size is currently the smallest extent size which allows
a user to create 8EiB devices (with 2GiB it's less then 8EiB).
TODO: lvm2 may possibly print amount of 'lost/unused space' on a PV,
since using such ridiculously sized extent size may result in huge
space being left unaccessible.
There are two basic groups of fields for LV segment device reporting:
- related to LV segment's devices: devices and seg_pe_ranges
- related to LV segment's metadata devices: metadata_devices and seg_metadata_le_ranges
The devices and metadata_devices report devices in this format:
"device_name(extent_start)"
The seg_pe_ranges and seg_metadata_le_ranges report devices in
this format:
"device_name:extent_start-extent_end"
This patch reverts partly what commit 7f74a99502
(v 2.02.140) introduced in this area - it added [] for
hidden devices to mark them for all four fields mentioned above.
We won't be marking hidden devices in devices and metadata_devices
fields.
The seg_metadata_le_ranges field will have hidden devices marked -
it's new enough that we don't need to care about compatibility much
yet.
The seg_pe_ranges is old enough that we shouldn't be changing this
one - so we're reverting to not marking hidden devices here.
Instead, there's going to be a new field "seg_le_ranges" which
is going to replace the seg_pe_ranges and it will mark hidden devices -
this is going to be introduced in a patch later.
So in the end we'll end up with:
(LV segment's devices)
devices field with "device_name(extent_start)" format, not marking hidden devices
seg_pe_ranges field with "device_name:extent_start-extent_end" format, not marking hidden devices (deprecated, new seg_le_ranges should be used instead for standardized format)
seg_le_ranges field with "device_name:extent_start-extent_end" format, marking hidden devices
(LV segment's metadata devices)
metadata_devices field with "device_name:extent_start-extent_end" format, not marking hidden devices
seg_metadata_le_ranges field with "device_name:extent_start-extent_end" format, marking hidden devices
Also, both seg_le_ranges and seg_metadata_le_ranges will honour the
report/list_item_separator setting which can be used to configure
the delimiter used for list items.
So, to sum it up, we will recommend using the new seg_le_ranges and
seg_metadata_le_ranges fields because they display devices with
standard extent range format, they can mark hidden devices and they
honour the report/list_item_separator setting.
We'll be keeping devices,seg_pe_ranges and metadata_devices fields
for compatibility.
The associated devices,metadata_devices,seg_pe_ranges and
seg_metadata_le_ranges are reported as genuine string lists now.
This allows for using the items separately in -S|--select
(so searching for subsets etc.) and also it allows for
configuring the separator using report/list_item_separator
which may be useful in scripts (however, we'll enable this
only for seg_le_metadata_ranges and not for devices,seg_pe_ranges
and seg_metadata_devices for compatibility reasons - see following
patch).
When reporting on LVs, take the end of the range from the size of the
underlying (hidden) LV rather than the logical size of the current
segment (that PVs use).
Fix lvm2app to return either 0 or 1 for lvm_vg_is_{clustered,exported},
including internal functions pvseg_is_allocated and vg_is_resizeable
which are not yet exposed in lvm2app but make them consistent with the
rest.
Thin pool discard mode set in metadata can be different from the one
actually used if any device underneath does not support that mode. Add
kernel_discard report field to make it possible to see this difference.
Internal _alloc_init() is only called from allocate_extents(),
which already does prevent usage of virtual segments.
So mark as internal error early and do not process it any further.
Add new test for lv_is_snapshot().
Also move few other bitchecks into same place as remaining bit tests.
TODO: drop lv_is_merging_origin() and keep using lv_is_merging().
Include brackets for the name if the dev is invisible.
This change applies to all callers of _format_pvsegs fn:
- lvseg_devices (the "lvs -o devices")
- lvseg_metadata_devices (the "lvs -o metadata_devices)
- lvseg_seg_pe_ranges (the "lvs -o seg_pe_ranges")
- lvseg_seg_metadata_le_ranges (the "lvs -o seg_metadata_le_ranges")
The common lv_pool_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
The common lv_metadata_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
The common lv_data_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
The common lv_mirror_log_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
The common lv_origin_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
The common lv_convert_lv fn avoids code duplication and also
the reporting part now uses _lvname_disp and _uuid_disp to display
name and uuid respectively, including brackets for the name if the
dev is invisible.
Have commands send lvmlockd the update message
in vg_write instead of vg_commit, so that it's
not done while LVs are suspended. If the vg_write
is not committed, and the seqno sent to lvmlockd
is not used, then lvmlockd can detect this when
the next update uses the same seqno.
Use process_each_vg() to lock and read the old VG,
and then call the main vgrename code.
When real VG names are used (not a UUID in place of the
old name), the command still pre-locks the new name
(when strcmp wants it locked first), before calling
process_each_vg on the old name.
In the case where the old name is replaced with a UUID,
process_each_vg now translates that UUID into the real
VG name, which it locks and reads. In this case, we
cannot do pre-locking to maintain lock ordering because
the old name is unknown. So, in this case the strcmp
based lock ordering is suppressed and the old name is
always locked first. This opens a remote chance for
lock ordering conflict between racing vgrenames between
two names where one or both commands use the UUID.
Since we mark cache-pool as 'hidden/private' while it is in-use,
we may still allow user to change it's name.
It should not cause any harm and user may prefer better naming
for a cache-pool in use.
After recent changes to process_each, vg_read() is usually
given both the vgname and vgid for the intended VG.
However, in some cases vg_read() is given a vgid with
no vgname, or is given a vgname with no vgid.
When given a vgid with no vgname, vg_read() uses lvmcache
to look up the vgname using the vgid. If the vgname is
not found, vg_read() fails.
When given a vgname with no vgid, vg_read() should also
use lvmcache to look up the vgid using the vgname.
If the vgid is not found, vg_read() fails.
If the lvmcache lookup finds multiple vgids for the
vgname, then the lookup fails, causing vg_read() to fail
because the intended VG is uncertain.
Usually, both vgname and vgid for the intended VG are passed
to vg_read(), which means the lvmcache translations
between vgname and vgid are not done.
Unifying terminology.
Since all the metadata in-use are ALWAYS on disk - switch
to terminology committed and precommitted.
Patch has no functional change inside.
We do not won't to 'expose' internals of VG struct.
ATM we use lists to keep all LVs - we may want to switch
to better struct for quicker 'search'.
Since we do not need 'lists' but always actual LV,
switch find_lv_in_vg_by_lvid() to return LV,
and replaces some use case of find_lv_in_vg()
with 'better' working find_lv() which already
returns LV.
Coverity here is a bit 'blind' here and cannot resolve which
code paths are actually able to hit this code path.
(It's using 'statistic' to resolve all possible paths,
and it's not scanning 'individual' code paths.)
This just cleans warns and add 'cheap' tests.
Skip testing target_pvs for NULL, we already
dereference it in many other places.
If check would ever be needed - it needs to be
in front of _raid_extract_images().
Currently the code creates the log separately after allocating space for
the data and as no data allocation is needed this second time,
total_extents ends up holding zero so use new_extents directly instead.
When reading a foreign VG we cannot write it, since
it belongs to another host. When reading a shared VG
we cannot write it because we may not have an ex lock.
(Or we may be reading the shared VG while not using
lvmlockd in which case it's like reading a foreign VG.)
Add the same checks for wiping outdated PVs. We may
read a foreign or shared VG, or see the PVs, while
another host is part way through writing a new version
of the VG to the PVs. This might cause us to think
some of the PVs are outdated. We do not want to
write another host's PVs, especially when we may
wrongly conclude they are outdated.
This option could never have been printed in lvm2 metadata, so it could
be safely removed as it could have been set only as 0.
These configurable setting is supported via metadata profile.
Use single code to evaluate if the percentage value has
crossed threshold.
Recalculate amount value to always fit bellow
threshold so there are not need any extra reiterations
to reach this state in case policy amount is too small.
Since plugin's percentage compare has been fixed,
it's now revealed wrong compare here.
The logic for threshold is - to allow to go as high
as given value e.g. 80% - so if pool is exactlu 80%
full it's still allowed to use it (dmeventd will not
resize it).
Running "vgremove -f VG & pvs" results in the pvs
command reporting that the VG is not found or is
inconsistent. If the VG is gone or being removed,
the pvs command should just skip it and not print
errors about it.
"Not found" is because the pvs command created the
list of VGs to process, including VG, then vgremove
removed the VG, then the pvs command came to to read
the VG to process it and did not find it.
An "inconsistent" error could be reported if vgremove
had only partially completed removing VG when pvs did
vg_read on the VG to process it, causing pvs to find
the VG in a partially-removed state.
This fix adds a flag that pvs uses to ignore a VG
that can't be read or is inconsistent.
The lvmcache info might be resued, most notably in lvm shell.
We need to be sure that even lvmcache_info marked as invalid
is removed from the lvmcache so it does not confuse any subsequent
code/commands executed later on.
Problematic example with the lvm shell:
lvm> pvs
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
Before this patch (/dev/sda still displayed in a way):
======================================================
lvm> pvremove /dev/sda
Labels on physical volume "/dev/sda" successfully wiped
(without lvmetad)
lvm> pvs
No physical volume label read from /dev/sda
(with lvmetad)
lvm> pvs
PV VG Fmt Attr PSize PFree
/dev/sda lvm2 --- 128.00m 128.00m
With this patch applied:
========================
lvm> pvremove /dev/sda
Labels on physical volume "/dev/sda" successfully wiped
(without lvmetad)
lvm> pvs
(with lvmetad)
lvm> pvs
Before this patch:
$ lvs -a -o name,layout,role test/lvmlock
LV Layout Role
[lvmlock] linear public
With this patch applied:
$ lvs -a -o name,layout,role test/lvmlock
LV Layout Role
[lvmlock] linear private,lockd,sanlock
Add metadata_devices and seg_metadata_le_ranges report fields.
Currently only defined for raid, but should probably be extended
to all other segment types that don't report all their device
usage in the 'devices' field.